|
Medical Consumables - Delivery Of Specific Medical Devices And Consumables For A Hemodynamic Station For The Clinic Of Anesthesiology And Intensive Care At St. Anna Umbal - Sofia Ad. Swan Ganz Monitoring Catheter - 7Fr, 3 Lumens, Length 110Cm, Proximal Lumen 30Cm From Tip.,Swan Ganz Thermodilution Monitoring Catheter For Rapid Determination Of Cardiac Output And Hemodynamic Indicators - 7.5Fr, 5 Or 6 Lumens, Vip (Venous Infusion Port) Port, Length 110Cm.,Swan Ganz Thermodilution Monitoring Catheter For Rapid Determination Of Cardiac Output And Hemodynamic Parameters, With Thermal Thread. Thermodilation Catheter For Continuous Cardiac Output (Cco), Stroke Volume (Sv), Mixed Venous Oxygen Saturation (Sv02), Systemic Vascular Resistance (Svr), Right Ventricular End-Diastolic Volume (Rvedv), Right Ventricular Ejection Fraction (Rvef),Monitoring Thermodilation Catheter, Applying An Intelligent Algorithm For Right Ventricular Pressure (Rvp) Waveform Analysis And Providing Continuous Right Ventricular Cardiac Output (Corv) That Is Updated Every 10 Seconds, Has A Global Hypoperfusion Index (Ghi) Parameter That Predicts Mixed Venous Desaturations Up To 15 Minutes In Advance.,Minimally Invasive Arterial Line Sensor For Hemodynamic Monitoring That Automatically Calculates Key Flow Parameters Every 20 Seconds. Monitor Cardiac Output (Co), Cardiac Index (Ci), Mean Arterial Pressure (Map), Stroke Volume (Sv), Stroke Volume Variations (Svv), Systemic Vascular Resistance (Svr),A Minimally Invasive Arterial Line Hemodynamic Sensor With Hypotension Prediction (Hpi) Software That Uses Machine Learning To Analyze The Patients Arterial Pressure Waveform And Predict Future Hypotensive Events.,Non-Invasive Sensor For Continuous Monitoring Of Blood Pressure And Cardiac Output From Finger Cuff, Cardiac Output (Co), Stroke Volume (Sv), Stroke Volume Variation (Svv), Systemic Vascular Resistance (Svr), Mean Arterial Pressure (Map),,Non-Invasive Sensor For Measuring Tissue And Brain Oximetry With An Optical Penetration Depth Of Up To 2.5 Cm, Including 5 Wavelengths Close To The Infrared Spectrum - 685, 730, 770, 810, 870 Nm.,Non-Invasive Sensor For Measuring Tissue And Brain Oximetry With An Optical Penetration Depth Of Up To 2.5 Cm, Including 5 Wavelengths Close To The Infrared Spectrum - 685, 730, 770, 810, 870 Nm. Unlocks The Cerebral Autoregulatory Index (Cai) Algorithm, Which Quantifies The Relationship Between Mean Arterial Pressure (Map) And Tissue Oxygen Saturation (Sto2),A Sterile, Single-Use Pressure Monitoring Kit That Transmits Blood Pressure Information From A Pressure Monitoring Catheter/Sensor To A Hemodynamic Station - Hemosphere Or, Via A Suitable Adapter, Another Monitoring System.,Introducer For Placement Of A Swan-Ganz Catheter, 8 Or 9Fr, With Hemostatic Valve, Length Of The Disc 10Cm, Dilator, With A Sleeve Preserving A Sterile Environment, Puncture Needle 17G, 70Mm, J Guide 46Cm Long;,Smart Pressure Cable Compatible With Hemosphere Alta
|