Tender For Provision Of Certain Sanction Works In The Area Of Age B/R-Ii And Age E/M Under Ge (Central) Delhi Cantt-10-1 Excavation in trenches n exc 1.5 m wide and not exc 1.5 m depth for foundation shafts wells cesspits manholes etc n exc. 10 Sqm on plan and n.exc 1.5 m in depth and getting out in soft and loose soil.2 M&L Cement concrete (l:4:8) type D2 using 40mm graded aggregate in foundations.3 Reinforced cement concrete type B-1(1: 1 1/2 :3) with 20 mm graded aggregate as in foundation including rafters footings foundation beam plinth beam bases for column etc basment slab under reamed piles and mass concrete 4 Reinforced cement concrete type B-1(1: 1 1/2 :3) with 20 mm graded aggregate in column pillars piers posts and struts .5 S&F TMT bars above 10 mm dia cut out length bent to shape including cranking, bending and binding with 0.9mm dia mild steel wire or securing with clip.6 S&F TMT bars 5 mm dia and over up to and including 10mm dia cut out length bent to shape including cranking, bending and binding with 0.9mm dia mild steel wire or securing with clip for striups.7 S&F Form work to sides of concrete foundations, footing bases of sides and soffits if any of foundation and plinth beams and similar work vertical or to better.8 S&F Form work to sides of pillars piers posts and struts piers columns and stanchions. 9 Providing and fixing 6mm thick Suede Finish Greenlam, or equivalent exterior grade Clad (High Pressure Laminates) made up of 1300mm x 3050mm in size and conforming to EN 438-6:2016 standard, EDF Grade. Exterior CLAD HPL should be made under high pressure, using thermosetting Phenolic resin treated kraft layers, Amino plastic resin treated Exclusive & UV conforming Exterior Grade Decorative paper on both sides and UV protection layer above the décor papers on both sides. Clad should be resistant to wet conditions and meets permissible increase on mass, have density >1.35 gm /cm3, UV resistance of a minimum of 4 on a grey scale rating after 1500 hours, Resistance to artificial weathering including light fastness of a minimum rating of 4 (after 650 MJ/m2 radiant exposure). The product must conform to European Fire-Retardant norms of Bs1d0 when classified in accordance with EN 13501-1. The Fire-Retardant Additive must be Halogen free to protect the environment. HPL must be a green product conforming to GRIHA, GreenPro and Green Guard Gold certification and meet Anti-bacterial and Anti-termite property under JIS Z2801 (The manufacturer should provide 12 years warranty on manufacturing related defects). Finish and colour of compact laminates should be finalized under direction of Engineer –in-charge.Clad should be installed on Aluminium tubular substructure in the size of 50mm x 25/50mm or as per site requirement fixed at a maximum centre-to-centre distance of 400mm to 600mm with the help of 5mm dia colour matching rivets with sliding holes and fixed holes on the HPL. The aluminium tubular substructure should be fixed on wall with the help of dead load bearing brackets and wind load bracket by 10mm fastener. Wind load bracket will have vertical slot & dead load bracket will have in horizontal slot & maintain 6mm both horizontal and vertical gap between two installed clad panels. Shade/design of clad should be finalized under direction of Engineer –in-charge.10 Providing and fixing of Stainless steel grade 304 golden letters in English with Main letter of name of institute (MANDIR MARG) of minimize size 225 mm with 275 mm raising. The rest of letters shall also be of Stainless steel grade 304 in golden with minimum size of 250 mm, 300 mm raising. The letters shall be fixed with the help of stainless steel studs on existing granite/HPL Sheet/ACP sheet which shall not be visible from the front. The stainless-steel studs shall be properly grouted with suitable sealant. The letters of name of institute in logo shall be engraved/etched in black letters over golden stainlesssteel sheet with heating process. The design of wall is mentioned in the tender drawing. The work shall have warranty/defect liability period of 36 months as per NIT.Test report for conformality of material wrt pecifications shall be provided.The work shall be executed to the satisfaction of Engineer- in-charge. After award of work,contractor shall provide a Design of signage with logo for approval of engineer -in - charge before implementation at site.11 Returning ,filling in including spreading levelling watering and well ramming in layers not exc 25cm thick in soil in any depth complete all as specified and directed by Engr-in-Charge12 Removing excavated soil/ materials to a distance not exc 50 mtr and depositing where directed at a level not exceeding 1.50 m above the starting point complete all as directed by Engr-in-Charge13 Demolition of reinforced cement concrete as in ground floor beams, chajjas shelves and other similar work, complete all as specified and directed.14 M&L for formwork soffits of suspended slabs such as roof slabs, roof beams ,beams hauanchings,griders, landings and similar works not exceeding 200mm thick (Horizontal or slopping with rough finished surface of concrete all as specified and directed.15 M&L Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats plats etc confirming to fe- 410 -Wgde, E-250- quality A 16 M&L for Preparation of new steel and iron surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of redoxide primer, complete all as specified.17 Material & Labour for providing and fixing stainless steel (Grade 304) grill made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the grill with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangementcomplete all as specified and directed. 18 M & L for brickwork with old size subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:619 M&L for 10 mm thick in CM 1:4 on new surfaces of concrete or brick surfaces of walls or chajjas or pillars finished even and smooth without using extra cement including scaffolding and necessary formwork if required complete all as specified and directed.20 M & L for preparation of new plastered surface of wall and applying two coat of cement based paint over one coat of primer from the same manufacturer including scaffolding if required complete all as specified and directed. 21 S&F Powder Coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including aluminium alloy Powder coated standard 10mm section window grill as per approved sample and as per IS specifications joining cleat for fixing etc. complete all as specified22 M&L anodised aluminium window/door and ventilator shutters, sliding or side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.),hinges type B-21 100mm long (2no.) suitable handle ,(01 no.) including 4mm thick glass panes or stainless steel wire mesh complete all as specified and directed. Note : The rate quoted by the contractor is inclusive of all fixture/fittings/glass/wire mesh etc.23 M&L for 10mm thick rendering in cement mortar 1:6 finished even and smoothe surface without using extra cement on wall and apply two coats of OBD complete all as specified and directed by Engineer-in-Charge 24 M& L for rubber moulded Chequered cement concrete colour tiles 30 cm x 30 cm x 25mm thick with mixture of grey cement & pigment set jointed and pointed in neat cement slurry in floors including 15mm thick screed bed in C M 1:6 complete all as specified and as directed. 25 M & L Machine pressed precast concrete interlocking dark coloured paver block any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 Grade all as specified and disposing to debries etc all as directed by Engr-in-Charge.26 M & L for Sand filling under floors or in foundations including watering and consolidation 27 S&F in Soft closing ball bearing telescopic channel of size 22 inch long fixed with screws in cupboards incl all fittings complete all as spd and directed by Engr in charge.Note : Runner/ Channel should be SS 304 grade and load capacity should not be less than 45 kgs 28 “S&F Modular Cabinet Kitchen accessories of Stainless Steel grade-304,6mm size rod thickness including :- (i) Perforated Cutlery basket, (ii) Grain trolley, (iii) Thali basket, (iv) Cup & saucer basket, (v) Glass basket, (vi) Plate basket, (vii) Premium magic corner (viii) Oil Pull out Tray ( Triple basket layer) of size as per site requirement all spd and directed by Engr in charge 29 S&F 40mm dia and 75mm long, extrruded fancy type SS handle for kitchen cup boards shutters, cabinets, crocery shelf drawers fixed with nuts, screw and washer of mild steel bright finished, complete all as specified.30 S&F ball catches with 8mm dia steel ball and brass body and striking plate including letting in and fixed, complete all as specified.31 S&F 75mm long SS L-Bihai hinges for kitchen cup boards shutters, cabinets, crocery shelf drawers fixed with nuts, screw and washer of mild steel bright finished, complete all as specified.32 S&F 18/19mm thick factory made PVC moulded solid board one side pre-laminated for cabinet boxes, crockery almirahs, books shelves etc with self and shutter full size fitted under/above the kitchen cooking platform and other rooms directed incl provn of fixing arrangement etc, complete all as specified and directed.33 Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as directed.34 M & L for cement concrete 1:3:6 (20mm graded aggregate) Cement concrete in foundations, filling and mass concrete complete all as specified and directed.35 S&F in Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 ® comple all as specified and directed.36 S&F Chain link MS galvanisd fencing, any size or type complete all as specified and directed.37 S&F Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire incl provission of binding wire any size or type complete all as specified and directed.38 S&F Mild steel screw bolts (machine made) any dia size with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5 cm long complete all as specified and directed.39 M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1 : 4 mixed finished even and fair complete all as specified. 40 S & F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified41 S & F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates42 M & L 600 mm x 600 mm for vitrified tiles 10 mm thick (square) polished in floors / dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm screed bed in CM 1:6 including demolition of existing old tiles complete all as specified and as directed43 M & L for 75 mm thick cement concrete type C-2, 1:3:6 (40 mm graded stone aggregate) as in sub base all as specified.44 S&F 2mm thick fibre glass translucent corrugated sheeting of any colour with two corrugations side lap fixed with coah screw and washer in roof, wall etc complete all as specified and directed45 M & L for 100 mm thick cement concrete type D-2, 1:4:8 (40 mm graded stone aggregate) as in sub base all as specified.46 Taking up or down 15 mm dia GI tubing and connections complete all as specified.47 S&F 15mm dia GI tubing medium grade with all fittings and fixed to wall and ceiling or laid in floors etc complete all as specified and directed48 S&F bib tap with crutch or butterfly handle, screwed down, screwed for iron pipe, 15mm dia, fancy type, cast copper alloy, chromium plated long body with flange complete all as specified.49 S&F CP brass shower rose 250mm size suitable for 15mm bore pipe with C P arms complete all as specified.50 Supply and fix PVC connection pipe of 15mm size with PTMT check nuts with washers of length 450mm, complete all as specified. 51 S & F 15 mm dia Brass CP WHB Mixer for mixing hot & Cold water screwed down for iron pipe and fixed complete all as specified.52 S & F in repairs 15 mm dia Brass CP mixer Swan Neck for sink mixing hot & Cold water screwed down for iron pipe and fixed complete all as specified53 S&F 1000 ltr capacity rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position with 20mm Ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule Minimum wt 20mm-210grm and s&f in repair 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed including of dismantling pvc water tank complete all as specified and directed.54 M& L for non skid coloured rectified ceramic tiles (400x400x)7 to 8mm thick in floors, etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed for laying floor in CM 1:6 including dismantling the existing tiles with screed and removal of debries out of MOD Land complete all as specified and directed by Engineer in Charge. 55 M&L for coloured ceramic tiles (300x600mm)/300x450x7mm thick on vertical surfaces on skirting /dados and risers to steps etc including rendering 10mm thick cement mortar in CM 1:4 ,including dismantling the existing tiles with screed and removal of debries out of MOD Land complete all as specified and directed by Engr-in-Charge. 56 S&F in repair vitreous China coloured European type WC with (single piece) wall / floor mounted including Vitreous china coloured 10 ltrs capacity cistern connection to drain,P trap or S trap and fixing bolts ,plastic water closet seat cover complete all as specified. 57 S & F Brass CP health faucet hand shower type with 8mm dia 1.2 Meter long Flexible Tube and Wall Hook screwed for iron pipe fancy type long body all as specified and directed.58 Supply & fix in repair CP connection pipe of 15mm x 600mm long with 2 Nos brass check nuts with washers, complete all as specified.59 S&F in repairs vitreous chinaware coloured wall hung wash hand basin with full pedestal of size 550mm x 480mm complete including , CP Waste coupling ,waste pipe ,complete fixing arrangement and cutting for and pinning in walls & making good complete all as specifed and directed by Eng in charge60 S&F in repair fancy type brass chromium plated toilet paper holder, complete all as specified.61 S&F in repair fancy type brass chromium plated soap dish, complete all as specified.62 S&F in repair CP grating 125mm dia, complete all as specified.63 S&F in repair aluminium peg set of 6 peg, 45 centimeter long, complete all as specified.64 S&F in repair chromium plated quarter turn brass 2 way bib cock (two in one) suitable for 15mm bore pipe complete all as specified and directed. 65 S&F in repair 15mm dia chromium plated quarter turn wall mixer hot & cold L bend 3 in 1 pattern fixing and connection to pipes, complete all as specified and directed. 66 S&F in repair fancy type 600mmx450mm bevelled edge mirror of selected quality glass mounted on 4mm thick and rectangular shape and fixed to wooden plugs with chromium plated brass screw and cupwashers, all as specified.67 S&F in repair fancy type chromium plated quarter turn brass angle valve type suitable for 15mm bore pipe complete all as specified68 S & F in repair fancy type sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with CP brackrt gaurd and railling 60 cm long complete all as specified.69 S&F in repair fancy type glass corner 300mm radius of 10mm thick toughned glass with CP railing fixed with screws fancy type complete all as specified 70 M & L for 18-20 mm thick Black Granite stone work (table rubbed and polished) over and including15mm thick Screed bed or bedding layer in CM 1:4, as in steps, jambs, pillars, window cills, cooking platforms and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite,front and side of slab moulded and polished including dismantling the existing stone slab with screed/ backing , complete all as specified and as directed by the Engineer-in-Charge.Note- The cost of making hole for Gas pipe in cooking plateform is included in unit cost of item and nothing extra shall be paid on this account. 71 Supplying and laying of CPVC 25 mm OD pipes SDR 11 & Plain/ Brass CPVC SDR 11 fittings as required on walls/ceiling or laying in floors upto G+5 storey bldg complete, all as specified.72 Dismantling boarding , any description, fixed in any position with screws complete all as specified 73 Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar, all as specified.74 S&F factory made uPVC any colour fixed glazed window/ventilator/partition made of ( small series) frame 47 x 50mm mullion 47 x 68mm both having wall thickness of 1.9 + 0.20mm and single glazing bead of appropriate dimension ( Area upto 0.75 sqmtr) comprising of uPVC multichambered frame and mullion (wherevr required) extruded profile duly reinforced with 1.60 +0.20mm thick galvanised mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropraiate dimension, EPDM gasket, G.I. fasteners 100 x 8mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless screw etc.Profile of frame shall be miterd cut and fusion welded at all corners, mullion (if reqd) shall be also fusion welded including 5mm thick toughened glass drilling holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of reqd size and approval quality, all complete as per approved drg and direction of Engr in charge. Note: For uPVC frame, sash and mullion extruded profiles ,minus 5% tolerance in dimension i.e depth and width of profile dimension in higher side shall be acceptable but no extra payment on this account shall be made75 Supply and fixing factory made uPVC white colour Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.(Area of door upto 2.00 sqm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete all as specified and directed by Engineer-in-Charge. (Glass shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.76 S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as directed.77 S & F 5.5 mm thick sheet glass selected quality and glazing with oil putty in squareds exc 0.50 sqm in each pane complete all as specified and directed.78 S & F stainless steel wire cloth (SS304 grade) 0.36 mm nominal dia of wire and average with of aperture 1.40 mm and fixed with stainless steel wire staples with wooden/aluminium beads/screws to window/door complete79 M&L 100mm thick Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface with broken stone 80 Reinforced cement concrete Design mix M-25 using 20 mm graded stone aggregate as in Slab supported on walls ,beams and columns in floor ,roof, landing, balconies, conpies, deck slabs and in sleves complete all as specified and directed.81 M&L form work to sides of slabs for rough finished surfaces of concrete flat, etc. complete all as specified and directed.82 Brick work with old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified.83 M&L for brick work with subclass B bricks, straight or curved on plan to any radius in half brick thick walls with old size bricks, built in cement mortar 1:4, complete all as specified.84 M & L for 10 mm thick rendering cement plaster in cement mortar 1:3 on concrete surfaces of ceiling, chajja and like surface finished even and smooth without using extra cement and applying three coats of white lime wash on newly plastered ceiling surfaces on ceiling complete all as specified and directed by Engineer-in-Charge.85 M&L for applying of wall care putty on newly plastered walls of 2-3mm thick including preparing the surface with even and smooth complete all as specified and directed. 86 M&L Preparation of newly plastered surfaces of walls and applying two coats of Oil bound distember on walls complete all as specified and directed. 87 M&L Preparation of newly plastered surfaces of walls and applying three coats of weather coat/apex paint on walls/ceilings complete all as specified and directed. 88 M & L Cement concrete type B-2 1:3:6 (40 mm graded stone aggregate) as in plinth protection, 75 mm thick finished even and smooth without using extra cement complete all as specified and directed.89 M&L Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick rendering in CM 1:4 .90 S&F Factory made solid panel pvc door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement. The door frame shall be fixed to wall using 8/100mm long M.S Screwsthrough the frame by using PVC fasteners. A minimum of 4 nos. of screws to provided for each vertical member & minimum 2 nos. for horizontal member etc 91 S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, 92 S&F MS butt hinges medium weight 100 mm size fixed with SS screws.93 S&F aluminium anodised barrel tower bolt extruded section 200 mm long and fixed with MS screws.94 S&F 150 mm extruded aluminium alloy handle anodised fabricated type and fixed with MS screws.95 Supplying and laying of CPVC 20mm OD pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified complete with fitting as required.96 Supplying and laying of CPVC 16mm OD pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified complete with fitting as required.97 S & F 110 mm dia (bore of pipe) cast iron (sand cast) soil, waste, vent pipe in any length with or without ears with cement joint fixed to walls, complete all as specified.98 S&F110mm dia (bore of pipe) cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with cement joints, complete all as specified.99 S&F Salt Glazed Stone Ware (SGSW) P traps square or round mouthed type size 150x150mm including excavation/earth work, bed concrete, surrounding concrete and CI grating, complete all as specified.100 S&F 500 ltr capacity rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position with 20mm Ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule Minimum wt 20mm-210grm and s&f in repair 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.101 S & F vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete including making good to floor102 S&F 10 ltrs capacity PVC colour low level flushing cistern with PVC flush pipe 32mm dia complete all as specified103 S&F Chromium plated bib tap fancy type with flange 15mm dia screwed for iron pipe or for brass ferrule complete all as specified.104 S&F Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified.105 S&F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe omplete all as specified.106 S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.107 M&L for PCC 1 : 2 : 4 type B2 using 20mm graded aggregates as in surfaces channels and drains complete all as specified. 108 Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement incl forms, moulds, mitred/stoped ends etc complete all as specified. 109 S&F DWCPE(SN8) 150mm dia (Internal Dia) pipes,snap fit coupler and rubber ring incl testing and laid and properly jointed laid in trenches to a level on concrete bed complete all as specified.110 Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 100mm internal dia pipe, complete all as specified.111 M&L for PCC 1:2:4 (using 20mm aggregate) type B-1 as in coping with plain fare faces finished even and smooth without using extra cement.112 S&F for Precast plastic fibre RCC Manhole cover with frame medium duty of overall ize 450 x 450 x 50mm factory made Make Poly crete. 113 M & L for Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade with multi stranded copper conductor drawn through in and including non metallic medium grade rigid PVC conduit, ISI marked not less than 20 mm dia including all accessories surface of wall/iron angle and including provision of 1.5 sqmm PVC insulated unsheathed copper cable FRLS as earth continuty conductor including fabricated branded PVC box duly make embossed, surface of walls and with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc, complete all as specified and as directed for the followings:- 113.01 One light point controlled by one, one way switch .113.02 One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board. 113.03 One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board114 All as per item No.113 herein before but with 4 Sqmm cable for one 3 pin 15 Amp switch socket outlet and using 4 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified and directed. Note for Item 6 & 7 : (i) In case the wiring is encountered with any beam/column, then the wiring will run on PVC casing&caping/Existing conduit to avoid any damage to the RCC portion. (ii) No cutting shall be done in the roof for laying PVC conduit for ceiling fan point wiring, in this specified portion wires shall run through the surface new conduit shall be provided as mentioned in note (i) above. (iii) Proper colour code will be used for wiring as per the electrical rule and as directed by EIC. 115 All as per item No.113 here in before but with 2.5 Sqmm cable for one 3 pin 15 Amp switch socket outlet and using 2.5 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified and directed. Note for Item 3 & 4 : (i) In case the wiring is encountered with any beam/column, then the wiring will run on PVC casing&caping/Existing conduit to avoid any damage to the RCC portion. (ii) No cutting shall be done in the roof for laying PVC conduit for ceiling fan point wiring, in this specified portion wires shall run through the surface new conduit shall be provided as mentioned in note (i) above. (iii) Proper colour code will be used for wiring as per the electrical rule and as directed by EIC. 116 M&L switch Modular type 6 Amps 230V AC complete all as specified.117 M&L switch Modular type 16 Amps 230V AC complete all as specified.118 M&L Modular socket outlet 5 pin 6 Amp socket 2 module complete all as specified.119 S&F ceiling rose surface PVC/Polycarbonate type with three terminals. 120 Supply and fix LED batten luminaire surface mounted , 4 feet system wattage of 20 Watts with lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>70, Power Factor > 0.9, , colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications,, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed. 121 S&F 35 W High efficient LED Flood light fitting with pressure die cast Aluminum housing and has lenses specially designed for Flood Lighting with polycarbonate cover. System level efficacy of the Luminarie should more than 100lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:65 protected. It has an electronic driver complaint to IEC safety standards with a power factor>.0.90, voltage variation range 140-270V, THD<20%, High and low voltage protection along with a surge protection of 4 KV internal including provision of Diffrent colour and shape and necessary clamps etc for fixing the light fittings on wall/ iron/steel angle fixed complete as specified and directed by engr-in-charge. 122 S&F MCB DB SPN 4 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar, neutral link earth link complete. Note:-(i) MCB shall be measured & paid separately (ii) make of DBs & MCB should be same123 S&F MCB SPN 40 to 63 Amps 240 volts 10 KA 50 HZ C curve complete. 124 S&F MCB SP 6-32 Amps 240 volts 10 KA 50 HZ C curve complete. 125 Supply,laying PVC under ground XLPE insulated heavy duty electric cables armoured with aluminium conductor, 1100 volts grade, cross sectional area 6 sqmm 2 core laying in trenches, fixed along wall, through GI pipe under floor complete.126 S&F for HDPE double wall corrugated pipes conforming to IS-14930 Part-II with IP Protection of IP-67 having outer dia 50 mm and inner dia of 32 mm with necessary couplers, bends etc for protection of LT cable all as specified and directed. 127 Excavation in trenches n.exc 0.45 m wide and n.exc 0.60 m depth for laying of LT cables etc. and getting out in hard/dense soil soil soil complete all as specified 128 M&L earthing complete with GI electrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earth plate not less than 1.50 mtr below normal ground level connected to GI wire 4.0 mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze drilled and screwed all as specified including excavation and earth work and disposal of surplus soil incl 15 mm GI tubing light grade and necessary fitting for protection of GI wire incl laying of alternate layer of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MS angle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia GI pipe Medium grade for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed. Note:- Galvanised wire and protection light grade GI pipe upto 7.5 mtr shall be deemed to be in the rates.129 Taking down carefully copper/aluminium point wiring (light/fan/ socket/power) complete from the wall by cutting/ chasing including fittings and fixtures such as switches, ceiling roses, pendants holder, regulators,sockets,light fittings etc for credit and making good the disturbed surfaces of wall, floor etc complete all as specified and directed.130 Taking down carefully sub main wiring of any description.131 S&F Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge. 132 S&F wall mounted angular Electric chimney black colour of suction power not less than 1050 Cum/Hr,Al casette with stainless steel outer layer ,touch control panel,3 speed motor with 250 watt with decorative smart cooker hood SS and glass ,energy efficent Led light with digital display , including ducting it can open upto at least 20 feet as per site required complete all as specified and as directed by Engr-in-Charge. Note:- In case if any slab/RCC portion obstructs the installation of chimney, then all the work from removing / breaking it properly to plastering the wall and white wasing it will be done in the rate of this job.133 S&F of modular AC Box consisting of 20 Amp multipower socket including MCB of capacity 25 Amp mini MCB, ‘C’ curve, single phase 240 V, AC including modular box, frame, cover plate including plug top with indicator complete all as specified and directed by Engr-in-Charge 134 M & L for Point wiring (concealed) for Instant geyser control with switch complete with 4 sqmm single core PVC insulated FRLS unsheathed cable 1100 volts grade with multi stranded copper conductor drawn through in and including non metallic medium grade rigid PVC conduit, ISI marked not less than 20 mm dia including all accessories concealed in wall by cutting chases and including provision of 4 sqmm PVC insulated copper cable FRLS unsheathed as earth continuty conductor including fabricated branded modular metal flush box duly make embossed, concealed in walls and with suitable modular inner and outer plate for housing switches etc, including 25 amp Modular switch complete all as specified and as directed Note :- S&F switch modular type 25 Amps, 1 module 230 V, AC complete all as specified are deemed to be quoted rate.135 M&L for Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls all as specified and as directed. Note:- (1) Two runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as unit length. (2) The damaged surfaces to be made good with plastering will be carried out by contractor and cost of the same deem to be included in the quoted rates. Nothing extra in this account will be admissible.136 S&F Instant Hot Water Geyser 3 Ltrs capacity,3 KW with corrosion proof thermoplastic external body ,ISI approved with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection complete all as specifiedand directed by Engineer -in-charge.137 S & F water heater storage type (Geyser) vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection, having adjustable knob for temperature control and inner tank should be glass line coated complete all as specified of capacity 25 ltr having heating element 1.5 KW and not less than 5 star rating. 138 S&F Ventilating Fan 200 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm complete all as specified and as directed.139 M&L for heavy duty exhuast Fan 230 mm sweep, 1400 RPM, metallic body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm complete all as specified and as directed.140 M&L Modular socket outlet 5 pin 6 Amp socket 2 module ISI marked complete all as specified.141 S&F Wall mounted fans AC single phase 230/240 V, of size 400 mm sweep, speed RPM 1400, Sturdy and shock proof body for fixing of wall fan complete all as specified & directed.142 S&F Padestral fan stand mounting AC single phase 230/240 V, of size 500 mm sweep, speed RPM 1400,Sturdy and shock proof body for fixing of fan complete all as specified & directed.143 M&L for breaking the old existing wall and making provn of a round hole for fixing of 450 mm sweep exhaust fan including making good to the disturbed wall/ portion and matching with existing colour.all as specified and directed.144 M & L for Point wiring complete with 2.5 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade with multi stranded copper conductor drawn through Existing PVC conduit/cassing capping , including provision of 2.5 sqmm PVC insulated unsheathed copper cable FRLS as earth continuty and fabricated branded modular metal flush box / M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:- complete all as specified and directed by Engineer in charge. Note for Item 2 : (i) In case the wiring is encountered with any beam/column, then the wiring will run on PVC casing & caping/Existing conduit to avoid any damage to the RCC portion. (ii) No cutting shall be done in the roof for laying PVC conduit for ceiling fan point wiring, in this specified portion wires shall run through the surface new conduit shall be provided as mentioned in note (i) above. (iii) Proper colour code will be used for wiring as per the electrical rule and as directed by EIC. 145 M&L switch piano flush type 5 Amp SP one way ISI marked complete all as specified.146 Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete.147 M&L MCB SPN 40 Amp B curve all as specified.148 M&L MCB SP 6 to 32 Amp B curve all as specified.149 Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 900 lm system lumen output with life time of 25000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.90, THD < 10%, color temperature > 6500 K , system efficacy at luminarie level > 110 Lumens/watt surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, short circuit and over circuit protection, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete.150 S&f fresh air fan PVC body, air delivery > 800 CMH , 5 number of blades, AC single phase 230/240 V of size 250 mm sweep with louvre fixed complete with suitable size ply by cutting into suitable size as required complete.151 Supply and fix 35 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete152 Material & labour for installation, testing & commissioning XLPE insulated PVC sheathed armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade, cross sectional area 16 Sqmm 2.0 core complete all as specified and directed.153 S&F in repair GI tubing light grade in trenches/fixed to wall/ceiling including required GI fitting of size 32 mm dia complete all as specified and directed. 154 Material & Labour of DWC ( double wall corrogated ) pipe of size 50 x63 mm dia ( innner & outer dia ) laying of XLPE cable all as as specified & directed 155 Schedule of CreditTotal in Figures Quoted Rate in Figures Quoted Rate in Words
|