Tender For Provision Of Amenities For Drivers And Visitors To Office Complex Astride Parade Road Under Ge (P) Br Thal Sena Bhawan Delhi Cantt - Surface Excavation Not Exceeding 30Cm Deep And Averaging 15Cm Deep And Getting Out In Soft / Loose Soil Complete All As Specified And Directed By Engineer-In-Charge. M&L For Excavating In Trenches, N.Exc 1.5 M Wide And N.Exc 1.5 M In Depth For Foundation Etc Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. N.Exc 10 Sqm On Plan And Getting Out In Soft/Loose Soil Complete All As Specified And Directed By Engineer-In-Charge. Returning, Filling In. Including Spreading, Leveling, Watering And Well Ramming In Layers N.Exc 25Cm In Soft / Loose Soil Complete All As Specified And Directed By Engineer-In-Charge. Removing Excavated Material (Soils) At A Distance N.Exc. 50 M Where Directed And Depositing At A Level N.Exc 1.5M Above The Starting Point Complete All As Specified And Directed By Engineer-In-Charge. M&L For Sand Filling Under Floors Or In Foundations, Cushioning To Interlocking Pavers /Tiles /Ug Cables Including, Leveling, Watering And Consolidation As Required Complete All As Specified And Directed By Engineer-In-Charge. M&L For Moorum /Red Bajri Filling In Floors Or Paving, Laid In Layers N.Exc 15Cm Thick, Spread, Levelled And Rammed Including Watering Complete All As Specified And Directed By Engineer-In-Charge. M&L For Plain Cement Concrete (1:4:8) Type D2 (Using 40 Mm Graded Stone Aggregate) As In Foundation, Filling And Mass Concrete Complete All As Specified And Directed By Engineer-In-Charge. M&L For Rcc M-30, Design Mix (Using 20 Mm Graded Crushed Stone Aggregate) As In Foundation Including Rafts, Footings, Foundation Beams, Plinth Beams, Bases For Columns Etc, Basement Slabs, Under-Reamed Piles And Mass Concrete Complete All As Specified And Directed By Engineer-In-Charge. M&L For Rcc M-30, Design Mix (Using 20 Mm Graded Crushed Stone Aggregate) As In Columns, Pillars, Posts And The Like Complete All As Specified And Directed By Engineer-In-Charge. M&L For Rcc M-30, Design Mix (Using 20 Mm Graded Crushed Stone Aggregate) As In Chajjas, Roof Projections Etc Complete All As Specified And Directed By Engineer-In-Charge. M&L For Rcc M-30, Design Mix (Using 20 Mm Graded Crushed Stone Aggregate) As In Beams, Cantilever, Bressumer, Lintles Over 1.5 M Span Complete All As Specified And Directed By Engineer-In-Charge. M&L For Rcc M-30, Design Mix (Using 20 Mm Graded Crushed Stone Aggregate) As In Slab Supported On Walls, Beams And Columns In Floors, Roof, Landings, Balconies, Canopies, Deck Slabs, Shelves And The Like Complete All As Specified And Directed By Engineer-In-Charge. M&L For Cleaning Concrete Surfaces Of Any Description And In Any Position And Applying Two Coats Of Blown Grade Hot Bitumen At The Rate Of 1.50 Kg/Sqm Each Coat Complete All As Specified And Directed By Engineer-In-Charge. M&L For Mild Steel Tmt Bars 10 Mm Dia And Over, Cut To Length, Bent To Shape Required Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With & Including Mild Steel Wire (Annealed) Not Less Than 0.90 Mm Dia Or Securing With Clips Complete All As Specified And Directed By Engineer-In-Charge. M&L For Mild Steel Tmt Bars 5 Mm Dia And Over, Cut To Length, Bent To Shape Required Including Cranking Bending Spirally For Hooping For Columns, Hooking Ends And Binding With & Including Mild Steel Wire (Annealed) Not Less Than 0.90 Mm Dia Or Securing With Clips Complete All As Specified And Directed By Engineer-In-Charge. Use & Waste Formwork To Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits (If Any) Of Foundation, Plinth Beams And Similar Work, Vertical Or To Batter For Rough Finished Flat Concrete Surfaces Complete All As Specified And Directed By Engineer-In-Charge. Use & Waste Formwork To Sides Of Columns, Pillars, Posts, Stanchions And The Like For Rough Finished Flat Concrete Surfaces Complete All As Specified And Directed By Engineer-In-Charge. Use & Waste Formwork To Soffit Of Suspended Slab Such As Roof Slabs, Floor Slabs, Landings And Similar Works (Sides Of Beam, Lintels), N.Exc 200Mm Thick (Horizontal Or Sloping) For Rough Finished Flat Concrete Surfaces Complete All As Specified And Directed By Engineer-In-Charge. Use & Waste Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc Also Splays Between Floors And Beam, Etc For Fair Finished Flat Concrete Surfaces Complete All As Specified And Directed By Engineer-In-Charge. Use & Waste Formwork To Chullah Hoods, Chajjas, Troughs And Similar Items Including Edges For Fair Finished Flat Concrete Surfaces Complete All As Specified And Directed By Engineer-In-Charge. Use & Waste Formwork To Edges Of Concrete Flats, Treads, Breaks In Floors, Window Cills, Concrete Railings, Openings In Concrete Walls, Floor And Roofs N.Exc 20 Cm Wide And Sides Of Rcc/Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exc 10Cm But N.Exc 20Cm Wide For Rough Finished Flat Concrete Surfaces Complete All As Specified And Directed By Engineer-In-Charge. M&L For Brick Work With Old Size Sub Class ‘B’ Bricks, Built In Cement Mortar (1:6), Straight Or Curved On Plan Exc 6M Mean Radius Complete All As Specified And Directed By Engineer-In-Charge. M&L For Hardcore Of Broken Stone Or Boulders Gauge N.Exc 63Mm, Deposited, Spread, Levelled In Layers N.Exc 15 Cm Thick, Watered And Rammed To A True Surface Complete All As Specified And Directed By Engineer-In-Charge. M&L For 75 Mm Thick Plain Cement Concrete (1:3:6), Type C2 (Using 40Mm Graded Stone Aggregate) As In Sub Base In Floor And The Like Complete All As Specified And Directed By Engineer-In-Charge. M&L For Vitrified Light Shade Ceramic Tiles 10Mm Thick (Square/Rectangular), Area Of Each Tile N.Exc 0.36 Sqm, Laid In Vertical Surfaces Such As Skirting & Dados Over & Including 10Mm Thick Rendering Coat In Cement Mortar (1:3), Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Surface Complete All As Specified And Directed By Engineer-In-Charge. M&L For Vitrified Light Shade Ceramic Tiles 10Mm Thick (Square/Rectangular), Area Of Each Tile N.Exc 0.36 Sqm, Laid In Flooring Over & Including 15Mm Thick Screed Bed Or Bedding Layer In Cement Mortar (1:6), Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Complete All As Specified And Directed By Engineer-In-Charge. M&L For Non-Skid Ceramic Coloured Tiles 7 To 8Mm Thick (Square/Rectangular), Area Of Each Tile Exc 0.11 But N.Exc 0.18 Sqm, Laid In Flooring Over & Including 15Mm Thick Screed Bed Or Bedding Layer In Cement Mortar (1:6), Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Complete All As Specified And Directed By Engineer-In-Charge. M&L For Glazed Ceramic Tiles Of Size 350X250X7Mm / 450X350X7Mm Thick, Laid In Vertical Surfaces Such As Skirting & Dados Over & Including 10Mm Thick Rendering Coat In Cement Mortar (1:3), Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Surface Complete All As Specified And Directed By Engineer-In-Charge. M&L For Granite (Of Any Type) Tiles 20Mm Thick, Machine Cut, Laid In Any Situation Over & Including 15Mm Thick Screed Bed Or Bedding Layer In Cement Mortar (1:4), Set And Jointed With Grey Cement Slurry And Pointed With White Cement With Admixture Of Pigment To Match The Shade Of Granite Stone Including Grinding And Polishing Complete All As Specified And Directed By Engineer-In-Charge. M&L For Rounding Of Exposed Edges Of Stone Slabs / Tiles As In Steps, Cooking Platforms And Other Similar Situations Complete All As Specified And Directed By Engineer-In-Charge. M&L For 50Mm Thick Plain Cement Concrete (1:2:4) Type B-2 (Using 40Mm Graded Stone Aggregate) As In Sub Base, Floor, Coping, Paving Plinth Protection, Finished Even And Fair Without Using Extra Cement Complete All As Specified And Directed By Engineer-In-Charge. S&F Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Door/ Window/ Ceosetory Windows & Other Frames/ Chowkhat Of Size 45 X 70 Mm Comprising Of Virgin Pvc Polymer Of K Value 58-60 (Suspension Grade), Calcium Carbonate And Natural Fibers (Wood Powder/ Rice Husk/ Wheat Husk) And Non Toxic, Fixed In Position With Ms Hold Fast / Lugs / Ss Dash Fasteners Of Required Dia And Length Complete As Per Direction Of Engineer-In-Charge. Note: For Wpc Solid Door/Window Frames, Minus 5Mm Tolerance In Dimension I.E. Depth And Width Of Profile Shall Be Acceptable. Variation In Profile Dimensions On Plus Side Shall Be Acceptable But No Extra Payment On This Account. Frame Shall Be Made Of Non-Toxic Additives (Maximum Toxicity Index Of 12 For 100 Gms) Fabricated With Miter Joints After Applying Pvc Solvent Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg/ Cum, Screw Withdrawal Strength Of 2200 N (Face) & 1100 N (Edge), Minimum Compressive Strength Of 58 N/Mm2, Modules Of Elasticity 900 N/Mm2 And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite/Borer Proof, Water/ Moisture Proof And Fire Retardant. S&F Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Decorative Type Flush Door Shutter Of Size 30Mm Thick, Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade), Calcium Carbonate And Natural Fibers (Wood Powder/ Rice Husk/ Wheat Husk) And Non-Toxic Additives (Maximum Toxicity Index Of 12 For 100 Gms) Having Minimum Density Of 650 Kg/Cum And Screw Withdrawal Strength Of 1800 N (Face) & 900 N (Edge), Minimum Compressive Strength 50 N/Mm2, Modulus Of Elasticity 850 N/Mm2 And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite/Borer Proof, Water/Moisture Proof And Fire Retardant. Wpc To Be Laminated With Pvc Foil Of Minimum 14 Microns Thick Of Approved Design Pasted With Hot Melt Adhesive On Both Faces Of Shutter And Fixing With Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk Ss Screws, Complete All As Specified And Directed By Engineer-In-Charge. Note: Stainless Steel Butt Hinges Shall Be Paid Separately Under Respective Item Of Schedule A / Boq S&F Aluminium Sections Powder Coated (Minimum Thickness Of Powder Coating 50 Micron) As In Frames For Doors, Windows, Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc Complete All As Specified And Directed By Engineer-In-Charge. S&F Aluminium Powder Coated Of Any Colour (Thickness Of Powder Coating Not Less Than 50 Micron) Window And Ventilator Glazed Shutters Without Sash Bars, Having Stile And Rails Of Size 44.60X30.00X3.18 Mm Thick With Triangular Aluminium Beading Of 15 Mm Size, Aluminium Sections Weighing 0.55 Kg/M, Side Hung Type, With & Including 4Mm Thick Plain Glass With Necessary Joining Cleats, Glazing Clips, Rubber Packing, Anodised Aluminium Snap Beading, Screws, Anodised Aluminium Fittings To Each Leaf Such As Peg Stays 150Mm Long (1 No.). Hinges Type B-21 100Mm Long (2 Nos), Suitable Handle (1 No.) Complete All As Specified And Directed By Engineer-In-Charge. S&F Anodised Aluminium Snap Grid Frame Work Of Size 605X605 Mm For False Ceiling With & Including 12 Mm Thick Perforated Particle Board Or Tiles For Insulation And Acoustic Porposes Of Size 595X595Mm Including Hangers 6 Mm Dia G.I. (Upto 1200Mm Length) Adjusting Level Fixed To Roof Slabs By Means Of Ceilling Cleats Made Out Of G.I. Flat 40 X 3 Mm Size 60Mm Long And Expansion Hold Fasteners 12.5Mm Dia 40Mm Long Complete All As Specified And Directed By Engineer-In-Charge. S&F 250Mm Long Mild Steel Sliding Door Bolts, Clip Type, Stove Enamelled Black With Bright Bolt Not Less Than 12Mm Dia With And Including A Minimum Of 6 Bolts And Nuts, Four On Bolt Plate And Two On Staple Plate And Fixed Complete All As Specified And Directed By Engineer-In-Charge. S&F 200 Mm Long Mild Steel Barrel Tower Bolts, Stove Enamelled Black With Bright Bolt Complete All As Specified And Directed By Engineer-In-Charge. S&F 100 Mm Long Mild Steel Cold Rolled Butt Hinges, Medium Weight, Fixed To Frame Complete All As Specified And Directed By Engineer-In-Charge. S&F Door Closer Hydraulically Regulated, Designation No. 2, Universal Type, Suitable For Door Shutters Of 701 To 850 Mm In Width And Of Weight Between 36 To 60 Kg And Fixed In Position Complete All As Specified And Directed By Engineer-In-Charge. S&F 150Mm Size Mild Steel Pressed Handle, Oval Type, Stove Enamelled Black Complete All As Specified And Directed By Engineer-In-Charge. S&F 20 Mm Outer Dia Of Cpvc Pipe Sdr 11 & Plain Cpvc Sdr 11 Fittings On Walls / Ceiling Or Laying In Floors Including Brass Cpvc Fitting (Elbow, Tee, Mta/Mbta, Fta/Fbta, Tank Adaptor, Union, Etc Sutable For 15Mm Bore Bath Fitting) Complete All As Specified And Directed By Engineer-In-Charge. Note:- Length Of Pipe Shall Be Measured With & Including All Fittings For Payment Purpose, Nothing Extra To Be Made For Fittings. S&F 500 Ltrs Capacity Rotational Moulded Polyethylene Water Storage Tank (Cylindrical Vertical With Closed Top), Isi Marked, Double Layered, Horisted And Fixed In Position Complete All As Specified And Directed By Engineer-In-Charge. S&F 20Mm Gun-Metal, Globe Or Gate Valve With Iron Wheel Head, Screwed Both Ends For Iron Pipe And Fixed Complete All As Specified And Directed By Engineer-In-Charge. S&F 20Mm Dia Bore Ball Valve, High Pressure Of Ptmt With Epoxy Coated Aluminium Rod & High Density Plastic Ball, Screwed For Iron Pipe And Fixed. (Minimum Weight 15Mm-142Gms/ 20Mm-210Gms./ 25Mm-455Gms/ 40Mm - 690 Gms) Complete All As Specified And Directed By Engineer-In-Charge. S&F 150X100 Mm Size Salt-Glazed Stoneware Gully Trap, Square Or Round Mouthed, Tvpe P With Ci Grating Including Jointing With Solvent Cement, Set In Cement Concrete (1:2:4) Type B1 (Using 20 Mm Graded Stone Aggregate) Complete All As Specified And Directed By Engineer-In-Charge. S&F 75 Mm Dia Bore Pvc (Swr) Pipes, Single Socketed, Fixed In Any Length With Rubber Ring Joints, Laid In Trenches Or In Floors Complete All As Specified And Directed By Engineer-In-Charge. S&F 75Mm Dia Bore Pvc (Swr) Bend, Any Radius Complete All As Specified And Directed By Engineer-In-Charge. S&F 75Mm Pvc (Swr) Vent Cowl Complete All As Specified And Directed By Engineer-In-Charge. S&F Beveled Edge Looking Mirror Of Size 600Mmx450Mm Of Selected Quality Glass, Mounted On 6Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers Complete All As Specified And Directed By Engineer-In-Charge. S&F Stainless Steel Soap Dish Of Any Type, Fixed To Wall With Plug & Chromium Plated Brass Screws Complete All As Specified And Directed By Engineer-In-Charge. S&F Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long Complete All As Specified And Directed By Engineer-In-Charge. S&F 75 Mm Size Pvc (Swr) Floor Trap, Plain With Grating Including Jointing With Solvent Cement, Set In Cement Concrete (1:2:4) Type B1 (Using 20 Mm Graded Stone Aggregete) Complete All As Specified And Directed By Engineer-In-Charge. S&F Tubular Towel Rail, 20Mm Dia, D Type, 60Cm Long Between Flange, Fixed To Wall With Plugs And Chromium Plated Brass Screws Complete All As Specified And Directed By Engineer-In-Charge. S&F 15Mm Dia Bore Stop Valve, Cast Copper Alloy, Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Fancy Type, Chromium Plated With Long Shank And Cup (Concealed Type), Screwed Both Ends For Iron Pipe Or For Unions Complete All As Specified And Directed By Engineer-In-Charge. S&F 15Mm Dia Bore Bib Tap, Cast Copper Alloy, Chromium Plated With Crutch Or Butterfly Handle, Fency Type, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Complete All As Specified And Directed By Engineer-In-Charge. S&F 10 Litres Pvc Valveless, Syphonic Action Type, Flushing Cistern, Low Level, White, With Inlet, Ball Valve, Float And Handle Including Brackets And 32Mm Dia Flush Pipe Of Polyethylene Of Low Or High Density Or Pvc For Low Level Cistern Complete All As Specified And Directed By Engineer-In-Charge. S&F 15Mm Size 450Mm Long Pvc Connection With Ptmt Nuts At Both Ends With Rubber Washer Complete All As Specified And Directed By Engineer-In-Charge. S&F Vitreous China Wash Down Water Closet Pan Pedestal Pattern, White (Excluding Fixing Bolt, Flushing Cistern And Flush Pipe) Complete All As Specified And Directed By Engineer-In-Charge. S&F Vitreous China Wash Down Water Closet Pan Pedestal Pattern, White (Excluding Fixing Bolts,Flushing Cistern And Flush Pipe) With & Including Health Faucet (Abs Body) With 15Mm Dia 1.20M Long Mild Steel Chromium Plated Flexible Tube And Abs Wall Hook, Making All Connections And Fixed In Position Complete All As Specified And Directed By Engineer-In-Charge. S&F Stainless Steel Toilet Paper Holder With Flat Recessed Type Complete All As Specified And Directed By Engineer-In-Charge. S&F Vitreous China Wash Basins, White, Angle Back Type Of Size 550X400Mm Including Brackets And Pedestal, Cutting For And Pinning The Ends Of Brackets Or Erecting Stands Including 32Mm Dia Bore Waste Coupling Of Ptmt (Half Or Full Threaded) With 32 Mm High Density Polyethylene Waste Pipe (Hdpe) Of Pressure Rating 6Kgf/Cm², Fixed To Walls Complete All As Specified And Directed By Engineer-In-Charge. S&F 15Mm Dia Bore Pillar Tap, Fany Type, Cast Copper Alloy With Capstan Head, Chromium Plated, Screwed Down, High Pressure With Or Without Lettered Hot Or Cold With Long Screwed Shank & Fly-Nut, Screwed For Iron Pipe And Fixed Complete All As Specified And Directed By Engineer-In-Charge. S&F Vitreous China Urinal Half Stall Bowl, Flat Back Large Of Size 420X395X635Mm, White With Grating And Union For Discharge Pipe Complete Including Providing And Fixing Plugs, Bedding Urinal Against Wall In Cement Mortar (1:2), Securing Urinal To Plugs With And Including 60 Mm Long Brass Screws, Pointing Around Urinal Back In Cement Complete All As Specified And Directed By Engineer-In-Charge. M&L For 15 Mm Thick Rendering On Other Than Fair Face Of Brick-Work Or On One Side Of Lathing, Applied In Two Layers, 1St Layer 10 Mm Thick In Cement Mortar (1:6) And 2Nd (Top) Layer 5 Mm In Cement Mortar (1:4) Mixed With Water Proofing Compound (Wpc) As Per ManufacturerS Instructions, Finished Even And Fair Complete All As Specified And Directed By Engineer-In-Charge. Note:- Wpc Shall Be Measured And Paid For Separately At Supply Only Rates. M&L For 10 Mm Thick Rendering On Fair Faces Of Concrete Surfaces Of Celing In Cement Mortar (1:4), Finished Even & Smooth Without Using Extra Cement Complete All As Specified And Directed By Engineer-In-Charge. M&L For 15 Mm Thick Rendering On Fair Faces Of Brick Work Or Concrete Surfaces Of Internal Wall In Cement Mortar (1:4), Finished Even & Smooth Without Using Extra Cement Complete All As Specified And Directed By Engineer-In-Charge. M&L For Preparation Of Newly Plastered Surfaces Of Walls And Finishing With Acrylic Smooth Exterior Paint Of Required Shade: New Work (Two Or More Coats Applied @ 1.67 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm Complete All As Specified And Directed By Engineer-In-Charge. M&L For Preparation Of Newly Plastered Surfaces Of Walls And Applying Two Coats Of Distemper Oil Emulsion Over A Coat Of Priming Chalk Whiting Complete All As Specified And Directed By Engineer-In-Charge. M&L For Preparation Of Newly Plastered Surfaces Of Ceiling And Applying Two Coats Of Distemper Oil Emulsion Over A Coat Of Priming Chalk Whiting Complete All As Specified And Directed By Engineer-In-Charge. M&L For Water Proofing Treatment To Rcc Roof Slab, Walls, Chhajjas Etc Complete All As Specified Here-In-Below And As Directed By Engineer-In-Charge:- (A) Providing 15Mm Thick Plaster Screed Bed Layer In Cement Mortar (1:3) Mixed With Water Proofing Compound As Per ManufacturerS Instructions On Concrete Surfaces, Finished Even And Fair Complete All As Specified. (B) Preparing Plastered Surfaces Of Roof Slab, Walls, Chhajjas Etc By Brooming With Broom, Sweeping Free From Dirt, Dust Etc And Evenly Applying A Coat Of Approved Water Based Bituminous Primer @ 0.30 Kg/Sqm Of Area Complete All As Specified. (C) Supply And Laying App Polymer Modified Approved Membrane, Non-Woven, Polyester, Weighing Not Less Than 3.0 Kg/Sqm With Side / End Overlaps As Specified And Joints Sealed By Torch Application Method All As Specified. (D) Carrying Out Test For Leakage / Seepage By Flooding Water For 24 Hrs And Rectifying The Defects, If Any Observed During Flooding Test To The Entire Satisfaction Of Ge. (E) Finally Applying A Coat Of Solar Reflective Bituminous Aluminium Paint @ 0.15 Ltr/Sqm On The Top Of Membrane Surfaces Complete All As Specified And Directed By Engr-In-Charge. Notes Applicable To Srl Item No. 71 : (I) Wpc Shall Be Measured An Paid For Separately At Supply Only Rates. (Ii) A Template Of Size 450 X 450 Mm To Each Bldg Where Roof Treatment Is Carried Out With Neatly Engraved Ca No, Date Of Completion Of Wpt, Expiry Date Of Wpt, Etc To Provided And The Cost Of The Same To Be Treated As Included In The Quoted Rate. (Iii) The Work Of Wpt Shall Be Carried Out By Authorised Manufacturer / Applicator M&L For 100 Mm Thick M-50 Grade Factory Made Rubber Moulded Coloured Machine Pressed Precast Concrete Interlocking Paver Block In Approved Design And Colour Confirming To Is 15658-2006 With Grey Cement And Pigment As Approved, Laid Over 40 Mm Thick Sand Cushion And Joints Filled With Sand Complete All As Specified And Directed By Engineer-In-Charge. Note:- Sand For Cushioning Shall Be Measured And Paid Under Respective Item Of Schedule A / Boq M&L For Mild Steel, Plain, Black Sheet In Wall Cladding, Steel Gates And Similar Work, Cut To Size, Holes Punched; Including Round Headed Screws, Clout Nails Or Rivets And Fixed To Wood Or Steel Framing With Plain 40 Mm Lap Joints With Riveted Or Welded Seams Including Bending Or Turning Up, Mitred Angles, Etc As Required Complete All As Specified And Directed By Engineer-In-Charge. M&L For Mild Stee Framed Work As In Doors Or Gates Of Angle Or Other Section With Gusset Plates, Rails, Braces, Etc Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering. Doors, Etc To Be Prepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings (Exclusive Of Steel Sheeting Or Other Covering, Running Rails And Guides) And Hanging; Also Fastening And Fixing Complete Confirming To Grade Fe-410 W (Gde-E-250) Quality-B Complete All As Specified And Directed By Engineer-In-Charge. M&L For Mild Steel Stairs (Framed) Including Stringers, Treades, Landings, Balusters, Hand Rails Etc Including Cleats, Brackets, Etc Complete, Confirming To Grade Fe-410 W (Gde-E-250) Quality-B.Complete All As Specified And Directed By Engineer-In-Charge. M&L For Preparation Of New Steel & Iron Surfaces Of Any Description Over 10 Cm In Width Or Grith, Not Otherwise Described And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Complete All As Specified And Directed By Engineer-In-Charge. M&L For Reinforcement Concrete Pipes, 300Mm Dia Class Np4, Laid And Jointed Complete With Collars Complete All As Specified And Directed. M&L For Cement Concrete Aggregate Bed To Drain Pipe 300 Mm Dia Including Packing Under And Haunching Against The Sides Of Pipe After They Are Laid And Tested In Cement Concrete 1:4:8 Type D-2 Using 40 Mm Graded Stone Aggregate Complete All As Specified And Directed. M&L For 15 Mm Thick Rendering On Fiar Faces Of Brick Work Or Concrete Surfaces Of Walls In Cement Mortar (1:4), Mixed With Water Proofing Compound, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed By Engineer-In-Charge. Note:- Wpc Shall Be Measured And Paid For Separately At Supply Only Rates. Supply Only Integral Water Proofing Compound Complete All As Specified And Directed. M&L For Cutting Into Existing Manholes For Connecting 150 Mm Dia Of Pipe To New Drain, Making Good To Pipe And Rendering, Cutting Out Existing Benching For And Forming Branch Channel (1/2 Round Or 3/4 Section) In Cement (1:2:4) Type B-1 (Using 20Mm Graded Stone Aggregate), Smooth Finished And Reforming Benching As Required Complete All As Specified And Directed By Engineer-In-Charge. S&F Sfrc Manhole Covers With And Including Frame Medium Duty Of Required Size Factory Made And Test Load 10 Tonnes (Md-10), Strength As Per Is-12592 (2002), Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. M&L For Plain Cement Concrete (1:2:4) Type B (Using 20 Mm Graded Stone Aggregate) As In Lintels Upto 1.5M Clear Span, Cills, Coping, Steps, Seismic And Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets And Railings Upto 60 Cm In Height, Kneelers, Apex Stones, Bed Plates, Kerbs Not Provided For, Water Troughs And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating, Complete All As Specified And Directed By Engineer-In-Charge. M&L For Point Wiring With 1.5 Sqmm Nominal Cross Sectional Area, Single Core, 1100 Volts Grade, Multi-Stranded, Pvc Insulated, Unsheathed Frls Copper Conductor Cable With And Including Continuous Earth Wire Of Size 1.5 Sqmm Nominal Cross Sectional Area, Single Core, 1100 Volts Grade, Multi-Stranded, Pvc Insulated, Unsheathed, Frls Copper Conductor Cable And Connected To Common Earth And Earth Dolly With Suitable Copper Lugs And Drawing Into And Including Rigid Non-Metallic Pvc Conduit Of 20Mm Dia Or Higher, Medium Grade With And Including All Pvc Conduit Accessories Concealed Into Wall By Cutting Chases And Modular Metal Flush Box, Modular White Cover Plate With Frame, Blanking Plate Etc Suitable For Mylinc / Coral / Sleek Model Accessories Etc And Making Good To Disturbed Surfaces To Match The Existing Complete All As Specified And Directed For The Following:- One Light Point Controlled By One, One-Way Switch 06 Amps. One Ceiling / Exhaust Fan Point Controlled By One, One Way Switch 06 Amps. One 3 Pin, 06 Amps Socket Outlet Point On Independent Board Controlled By One, One Way 06 Amps Switch. One 3 Pin, 06 Amps Socket Outlet Point On Same Board Controlled By One, One Way 06 Amps Switch. All As Per Srl Item Item No. 84.00 Above But Point Wiring With 2.5 Sqmm Single Core Frls Cables And Earth Continuity Wire Of 1.5 Sqmm Single Core Frls Cable For One 3 Pin 15 Amps Socket Out Let Point Controlled By One, One Way Switch On Independent Board Complete All As Specified And Directed By Engineer-In-Charge. S&F Modular Switch, 06 Amps, Single Pole, One Way, 230 Volts, One Module And Ip 20 Protection Complete All As Specified And Directed By Engineer-In-Charge. S&F Modular Switch, With Indicator, 16 Amps, Single Pole, One Way, 230 Volts, One Module Complete All As Specified And Directed By Engineer-In-Charge. S&F Modular Socket Outlet 05 Pin, 06 Amps, 02 Module With Shutter Complete All As Specified And Directed By Engineer-In-Charge. S&F Modular Socket Outlet 02 In 01, 03 Pin, 06 Amps & 16 Amps, 02 Module With Shutter Complete All As Specified And Directed By Engineer-In-Charge. S&F Ceiling Rose, 6 Amps, 3 Terminal Including Connection Complete All As Specified And Directed By Engineer-In-Charge. S&F Modular Ceiling Fan Regulator, 02 Module, Ac, 230 Volts, 120 Watts, Duly Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. S&F 10 / 12 Watt Led Tube Light Fitting (2 Ft) Attractive Wall Mounted Type Suitable For Mirror Fittings, All Accessories Pre-Wired Including Fixing On Wall / Ceiling And Connecting Up With Twin Core Flat Flexible Copper Conductor Cable Of Suitable Size Complete All As Specified And Directed By Engineer-In-Charge. S&F Led Batten Lighting Fixture 20 Watts Led 5700K (4), With Extruded Aluminium Heat Sink, Integrated Electronic Driver And All Accessories Pre-Wired Including Fixing On Wall / Ceiling And Connecting Up With Twin Core Flat Flexible Copper Conductor Cable Of Suitable Size With Connector Block Complete All As Specified And Directed By Engineer-In-Charge. S&F Led Luminaire 600 Mm X 600 Mm, 35/36 Watt, 220 V Ac Recessed Type With High Efficiency Pmma Diffuser Soft Glare Free Light Complete With Driver, Holders & Led Lamp Suitable For Roof Ceiling Including Fixing In Position And Connecting Up With Driver Three Core Flexible Copper Conductor Cases Of Suitable Size Complete All As Specified And Directed By Engineer-In-Charge. S&F Exhaust Fan, Steel Body Ac Single Phase, 230Volt Of Size 300M Sweep With Blades, Frame And Louvers Including Cutting Hole In Wall, Making Of Wooden Frame For Mounting Of Fan And Making Good The Disturbed Surfaces Etc Complete All As Specified And Directed By Engineer-In-Charge. S&F Electric Water Heater, Storage Type 25 Ltrs Capacity, Bee Star Rated, Vertical Type With Suitable Size Of Fastner And Provision & Connecting Up Of Ss Braided Pipe With Adapter For Inlet And Outlet Water Connection Alongwith Nrv Cast Copper Alloy And 15Mm Dia Bore Stop Valve, Copper Element Corrosion Resistance Anti-Scaling Magnesium Anode Having Adjustable Knobe For Temperature Control And Inner Tank Material Of Superior Glass Lined Tank And Outer Body Material Abs With High Pressure With Standing Capacity Upto 8 Bar Pressure Having Heating Element 2 Kw And Minimum Two Year Warranty On Product & Minimum Three Years On Heating Element Complete All As Specified And Directed By Engr-In-Charge. M&L For Sub Main Wiring With 4 Sqmm Nominal Cross Sectional Area, Two Single-Core, 1100 Volts Grade, Multi-Stranded, Pvc Insulated, Unsheathed, Frlsh Copper Conductor Cable With And Including Continuous Earth Wire Of Size 2.5 Sqmm Nominal Cross Sectional Area, Single Core, 1100 Volts Grade, Multi-Stranded, Pvc Insulated, Unsheathed, Frlsh Copper Conductor Cable Drawing Into And Including Rigid Non-Metallic Pvc Concealed Conduit Of 25 Mm Dia, Medium Grade With All Conduit Accessories And Connected To Common Earth Dolly With Suitable Copper Lugs Including All Cutting / Chases Etc In Walls And Making Good To The Disturbed Surfaces To Match The Existing Complete All As Specified And Directed By Engr-In-Charge. All As Per Srl Item No. 97.00 Here-In-Before But Sub Main Wiring With 6 Sqmm Nominal Cross Sectional Area Frlsh Copper Conductor Cable With And Including Continuous Earth Wire Of Size 6 Sqmm Nominal Cross Sectional Area Frlsh Copper Conductor Cable. All As Per Srl Item No. 97.00 Here-In-Before But Sub Main Wiring With 10 Sqmm Nominal Cross Sectional Area Frlsh Copper Conductor Cable With And Including Continuous Earth Wire Of Size 6 Sqmm Nominal Cross Sectional Area Frlsh Copper Conductor Cable. S&F Industrial Type Spn Enclosure With A Two Pin And Earth Plug And Socket Complete With And Including Mcb, Sp, 20 Amps, Ac, 230 Volts C Curve, 10 Ka Breaking Capacity And Flush To Wall Including All Cuttings & Chases Etc In Wall And Making Good To The Disturbed Surfaces To Match The Existing Complete All As Specified And Directed By Engr-In-Charge. S&F Led Street Light Fitting 35 Watt 230 Volts, Ac Outdoor Type With High Pressure Die Cast Aluminum Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Including Thermal Management In Multiple Optics Complete With Ip 65/66 Protection Complete All As Specified And Directed By Engr-In-Charge. M&L For Street Light Bracket Made Out Of Gi Pipe Light Grade 32 Mm Dia Bore 1.20 M Long, Bent To Shape And Reduced To Required Size At Top Upto 1.00 M Length By Cutting, Welding And Well Finishing Including 2 Nos Ms Clamps Of Flat Iron Of Size 25X5Mm Of Suitable Length With Drilling Hole, Fixing With Nuts, Bolts & Washters Including Painting With Two Coats Of Aluminium Paint Over A Coat Of Red Oxide Primer Complete All As Specified And Directed By Engr-In-Charge. S&F Sheet Metal Enclosure Distribution Board Triple Pole And Neutral (Vtpn), Ac, 415 Volts, 04 Ways With 200 Amps Rated Copper Bus Bar And Metal Double Door Suitable For Mccb 125 Amps As Incomer And Mcb Sp As Outgoing Along With Cable End Box For Above Db And Flush To Wall Including All Cutting Etc In Wall And Making Good To The Disturbed Surfaces To Match The Existing Complete All As Specified And Directed By Engr-In-Charge. Note : Mccb & Mcb Shall Be Measured Separately S&F Mccb 100 Amps, 4 Pole, 415 Volt, Ac, Fixed Type With Breaking Capacity 16 Ka Suitable For Load Line / Vtpn Db Including Connecting By Using Suitable Copper Lugs, Testing And Commissioning Complete All As Specified And Directed By Engineer-In-Charge. S&F Mcb Single Pole (Sp) 6 To 32 Amps Rating 240V, 10 Ka C Curve, Fixed In Mcb Db Including Connecting By Using Suitable Copper Lugs, Testing And Commissioning Complete All As Specified And Directed By Engineer-In-Charge. S&F Mcb Single Pole & Neutral (Spn) 40 To 63 Amps Rating 240V, 10 Ka C Curve, Fixed In Mcb Db Including Connecting By Using Suitable Copper Lugs, Testing And Commissioning Complete All As Specified And Directed By Engineer-In-Charge. S&F Mcb Sp 40 Amps Rating, 240 Volt, B Curve, 10 Ka Rupturing Capacity Including Necessary Connection In Mcb Db Using Suitable Copper Lugs, Testing And Commissioning Complete All As Specified And Directed By Engr-In-Charge. S&F Sheet Metal Enclosure For 8 Way Distribution Boards (DbS), Double Door, Single Pole & Neutral With 200 Amps Rated Bus Bar, Ip-20 Protection Suitable For Fixing McbS/Isolators And Fixed In Position Complete All As Specified And Directed By Engr-In-Charge. Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep. Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc) Motor, Class Of Insulation: B, 3 Nos Blades, 30 Cm Long Down Rod, 2 Nos Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cmm/W) Minimum 6.85, Air Delivery Minimum 220 Cmm, 350 Rpm (Tolerance As Per Is: 374-2019), Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut & Bolts, Washers, Temperature Rise ˜75 Degree C (Max.), Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 Volts, 50 Hz, Single Phase Ac Supply, Earthing Etc Complete As Required Including Connecting Up With Twin Core Flat Flexible Copper Conductor Cable Of Suitable Size With Connector Block To Ceiling Rose Complete All As Specified And Directed By Engr-In-Charge. S&F Desert Cooler Of Steel Body Size 25X25X32, Made Out Of Corrosion Resistant, 18 Swg Gi Sheet Duly Powder Coated Paint With 500 Mm Sweep Copper Wound Fan Motor Kit Of Not Less Than 180 Watt With Metallic Blade, Isi Marked, 1400 Rpm, 230 Volts, Ac, Having Nominal Air Flow Capacity 4000 Cum Per Hour (Or Nearest Size), Water Tank Capacity Not Less Than 100 Ltr, Including Plastic Submersible Pumps, Electronic Fan Regulator With Piano Type Switch, Cooler Stand Of Suitable Size As Directed And Fixing The Desert Cooler To Existing Window Including Covering The Remaining Window Portion With 6 Mm Thick Plywood As Required Size At Site Complete All As Specified And Directed By Engr-In-Charge. Supply, Installation, Testing And Commissioning Of Water Cooler Fully Stainless Steel, Electric Driven Single Phase Having Approx Storage Capacity 40 Ltr And Nominal Cooling Capacity 40 Ltr Complete All As Specified And Directed By Engr-In-Charge. Supply, Installation, Testing & Commissioning Of Ro Plant 50 Ltr/Per Hr, Wall Mounted, Having Capacity To Treat The Raw Water Having Tds 1200 Ppm. The Treated Water Should Have Tds Less Than 60 Ppm And Hardness Less Than 10 Ppm Or As Per Who Standards. The Operating Voltage To 230 Volt, Ac + 10%, Alongwith Required Capacity High Pressure Pump And Solenoid Valves, Dry Run Protection Of Pump, Automatic Tank Level Control, Inbuilt Auto Flush Timer For Periodic Flushing Of Membranes, Over Voltage And Over Current Protection With Switch Mode Power Supply System Complete In All Respects Including Installation Fittings. Potable Water System Components Shall Comply With Safe Drinking Water Act Amendments, The 1988 Lead Contamination Control Act And Shall Conform To Ansi/Nsf 61 Section 9. Contractor Will Submit Required Test Report Post Installation Of Ro Plant And Cost Shall Be Inclusive Of 01 Day Training To User Staff Complete All As Specified And Directed By Engr-In-Charge. M&L For Earthing With Galvanized Steel Earth Plate Electrode Of Size 60Cmx60Cmx6Mm Thick, Buried Directly In Ground Vertically At A Depth Not Less Than 2.25 M Below Normal Ground Level (Ngl) With Top Edge Of Earth Plate At A Depth Not Less Than 1.5 M Below Normal Ground Level, Earth Plate Surrounded From All Sides By 15Cm Thick Packed Layer Of Charcoal Dust And Common Salt Filling In Alternate Layers And Electrode Connections By Using Gi Wire Of Size 4Mm Dia As Earthing Lead (Upto The Body Of The Equipment) By Means Of Gi Bolts, Nuts, Check Nuts, Washers And Thimbles And Protected By Light Grade 40Mm Dia Gi Pipe Connected To Main Switch Board Or Main Control Board And Gi Pipe Medium Grade 20Mm Bore For Watering Including Funnel, Wire Mesh, Rcc Pit Cover And Pcc Chamber Pit With Pcc (1:3:6) Type C-2 (Using 40Mm Graded Stone Aggregate), Including Excavation And Earth Work In Any Type Of Soil, Returning, Filling In Approved Soil And Disposal Of Surplus Soil To A Distance N.Exc 50M All As Specified And Shown In Electrical Plate No. 5 Of Ssr (Part-I) Complete All As Specified And Directed By Engr-In-Charge. All As Per Srl Item No. 113.00 Here-In-Before But Using Galvanized Iron Strip 25 X 4 Mm As Earthing Lead . S&F Garden Light Fitting 10 Watts, Ip65 Rated Led Bollard Light Including Necessary Brick/Pcc Work Complete All As Specified And Directed By Engr-In-Charge. Supply, Laying And Testing 35 Sqmm 3.5 Core Cable Xlpe Lnsulated, Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables (Heavy Duty) 1100 Volts Grade With Stranded Aluminium Conductor Of Following Sizes And All Fixing & Connecting Accessories Such As Cable Lugs, Cable Glands, Nut, Bolts, Complete Complete All As Specified And Directed By Engr-In-Charge. All As Per Srl Item No. 116 Above But 10 Sqmm 4 Core Cable All As Per Srl Item No. 116 Above But 10 Sqmm 2 Core Cable Supply & Laying Well Burnt Old Size Sub Class B Bricks Of Nominal Size 230X115X75 Mm Abutting Each Other For Mechanical Protection Of Cable With Width Equal To Lenght Of Brick Complete All As Specified And Directed By Engr-In-Charge. Supply & Laying 40Mm Dia Bore Gi Tubing, Light Grade With All Necessary Fittings, Laid In Trenches/Under Road Crossing/Fixed On Pole/Wall Of Laid Under Flooring Including Suitable Mild Steel Fi Clamps Of Required Size Complete All As Specified And Directed By Engr-In-Charge. S&F Steel Tabular Swaged Poles, Type 410 Sp-31 (9 Meters Long) With Ci Base Plate, Bolts, Nuts & Screws Including The Following Works Complete All As Specified And Directed By Engineer-In -Charge :- (A) Excavation In Post Hole / Trenches Not Exc 1.5 M Wide & 2 M Deep For Pole Foundation & Getting Out In Soil Loose Soil, Returning, Filling In With Excavated Soil After Fixing The Pole In Foundation, Ramming Earth Around In Layers N.Exc 25 Cm Thick And Disposal Of Surplus Soil To A Distance N.Exc 50 M. (B) M&L For Pcc (1:3:6) Type C2 (Using 40 Mm Graded Stone Aggregate) For Plinth Block/Collar Above Gl, 300 Mm High And 450 Mm Dia (C) M&L For Painting Of Pole Externally With One Coat Of Black Bituminous Paint (Upto Planting Depth) And Above Plinth Block / Concrete Collar With Two Coats Of Aluminium Paint Over A Coat Of Red Oxide Primer Including Preparation Of Surfaces And Painting 30 Cm Wide Black Bands/Strips 3 Nos With Synthetic Enamel Paint In Alternate Layers Upto The Height Of 1.5 M Above Coping Level Complete All As Specified And Directed By Engr-In-Charge. M&L For Circuit/Submain Wiring Alongwith Earth Wire With Fr Pvc Insulated Copper Conductor, Single Core Cable With 2 X 1.5 Sqmm Earth Wire In Steel Conduit Surface/Recessed As Required For Street Light Poles Complete All As Specified And Directed By Engr-In-Charge. S&F Street Light Pole Junction Box Of Size 200 X 160 X 98Mm, Made Of High Quality Thermosetting Plastic Polyasterene, Dust And Jet Water Proof, Chemical / Acid Corrosion Resistant Impact And Shock Proof Ip 65 With Internally Imbedded Gasket (Pur) Including 1 No. Sp Mcb 6 Amps Alongwith Door Arrangement And Pre-Mouthed Knock Out All The Sides Including Back Of The Base. The Box Must Be Fitted With 10 Sqmm Stud Type Terminal 04 Nos Including Elmex Stud Type Tb 04 Nos Including Connection Using Cable Lugs / Glands Complete All As Specified And Directed By Engr-In-Charge. Note: - Cost Of Incoming And Outgoing Cable Lugs & Glands Of Suitable Size Deemed To Be Included In The Quoted Rate Fabrication And Supply, Errection, Testing Complete Lt Panel Board Outdoor Type Made Out Of 3.15 Mm Thick Ms Sheet Vermin Proof And Water Proof With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer. Lt Panel Shall Be Fixed To Angle Iron Frame Of Size 40 X 40X 6 Mm (Length Of Angle Iron Legs 60 Cm From Lt Panel Including All Pcc Works For Fixing The Frame Complete) And Suitable Size Of Cable Glands Chromium Plated Complete, Including Bus Bar Chamber With Bus Bar Capacity Of 200 Amps And Phase Indication Colour Sleeving Bus Bar Strips With 3 Phase And Natural Voltmeter And Amp Meter, Ct And Consisting Of The Following : - (A) Volt Meter With Selector Switch 0 To 500 Volts –01 No. (B) Amp Meter With Ct 0 To 200 Amps – 01 No. (C) Phase Indicator Lamp Red Green & Yellow (Rgy) - 03 Nos (D) Mccb 160 Amps Three Pole, 50 Hz, 415 Volts With Rupturing Capacity 35 Ka- 01 No. (Incoming) (E) Mccb 63 Amps Three Pole, 50 Hz, 415 Volts With Rupturing Capacity 25 Ka - 03 Nos Supply & Laying 40Mm Dia Bore Gi Tubing, Medium Grade, Isi Marked Including All Fittings, Laid In Trenches / Fixed To Walls Or Laid In Floors Including Making Good The Disturbed Surfaces Complete All As Specified And Directed By Engr-In-Charge. Note: Excavation & Earth Work Shall Be Measured And Paid For Separately. All As Per Srl Item No. 125.00 Above But 25Mm Dia Bore Gi Pipe S&F 40Mm Dia Bore Gun Metal Globe Or Gate Valve With Iron Wheel Head, Screwed Both Ends For Iron Pipe And Fixed Complete All As Specified And Directed By Engr-In-Charge. S&&F 25Mm Dia Bore Stop Valve, Cast Copper Alloy, Screwed Down, High Pressure With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or Union And Fixed Complete All As Specified And Directed By Engr-In-Charge. Cutting The Existing Ci / Gi Water Supply Pipeline Up To 200 Mm Dia For Inserting Suitable Size Gi Tee And Socket Of Size Upto 40Mm Dia For Taking Branch Connection For Potable Water Including Necessary Excavation And Making Good The Disturbed Area Complete All As Specified And Directed By Engr-In-Charge. Boring Holes Upto 80Mm Bore Under Road Pavement By Bocky Manually In Any Type Of Soil Complete All As Specified And Directed By Engr-In-Charge.
|