|
Tender for Earthwork In Excavation Of Foundation In Hard Soil Including Dressing & Levelling Of Bed Within Initial Lead Of 50Mt. & Lift Of 1.5Mtr Etc Complete As Per The Direction Of The Engineer-Incharge. , Excavation In Hard Soil Such As Hard Stiff Clay, Stiff Black Cotton, Hard Red Earth, Shales, Moorum Ordinary Gravels, Within 50M. Initial Lead And 1.5M. Initial Lift Including Rough Dressing And Breaking Clods And Stacking Rubble Or Spreading And Leveling Within The Site As The Case May Be Etc; Complete.Asper Direction Of The Engineer-In-Charge.(Mechanical 60% & Mannual 40%) , Filling In Foundation & Plinth With Sand Including Watering & Ramming Etc Complete As Per The Direction Of The Engineer-Incharge. , Cement Concrete (1:4:8) With 4Cm Size H.G.B. Hand Broken Metal Of Approved Quality From Approved Quarry With Ramming Watering And Curring Etc. Complete Including Cost, Taxes, Royalty Convence Charge Of All Material To Worksite, Supply Of Cement T&P Required Etc. Complete As Per The Direction Of The Engineer-Incharge. , Pcc/Rcc Cement Concrete (1:2:4) With 12Mm Size Black C.B. Hand Broken Chips Of Approved Quality From Approved Quarry With Ramming Watering And Curring Etc. Complete Including Cost, Taxes, Royalty Conveyance Charge Of All Material To Worksite, Supply Of Cement T&P Required Etc Complete As Per The Direction Of The Engineer-Incharge. , Fly Ash Brick Work 25Cm X 12Cm X 8Cm Size Having Crushing Strength Not Less Than 75Kg / Cm2 With Dimensional Tolerrance + 8% In Cement Mortar (1:6) In Foundation & Plinth Etc. Complete As Per The Engineer-Incharge. , Fly Ash Brick Work 25Cm X 12Cm X 8Cm Size Having Crushing Strength Not Less Than 75Kg / Cm2 With Dimensional Tolerrance + 8% In Cement Mortar (1:6) In Super Structure Etc. Complete As Per The Engineer-Incharge. , 12Mm Thick Plaster In Cement Mortar (1:6) Finished Smooth To Brick Massonary After Racking Out Joints Including Waterring And Curring With Cost, Taxes, Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&P Required For The Work Etc Complete As Directed By The Engineer-Incharge. , Rigd Smooth Centering And Suttering For Reinforced Cement Concrete Works Including Reinforced Cement Concrete Lintel Data (For 9.00 Sqms.) , Rigd Smooth Centering And Suttering For Reinforced Cement Concrete Works Including Roof Slab, Reinforced Cement Concrete Floor, Landing Balcony, Projection Sun Shed & Chajja, Sheles Data (For 9.00 Sqms.) , Labour Charge For M.S. Reinforcement For Reinforced Cement Concrete Work Including Cutting, Bending & Typing The Grills & Placing In Position Including Cost Of Binding Wire 18 To 20 Guage Per Qntl. Including Cost Of Hysd Steel Bar (Fe 415/ Fe 500) , Cement Punning Over Plastering Including Waterring And Curring With Cost, Taxes, Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&P Required For The Work Etc Complete As Directed By The Engineer-Incharge. , 2.5 Cm (1) Thick Artificial Stone Flooring With Cement Concrete(1:2:4) Including Punning Using 12 Mm Size Hard , Cost Of M.S. Fabricated Door & Window Including Fitting And Fixing Charges Etc. Complete. (Size Door 3Ft X 6Ft) (W- 2Ft X 3Ft) , 2.5 Cm Thick Grading Concrete (1:2:2) On Roof Slab With 6Mm Size H.G (C.B) Chips On New Work Including All Cost Etc. Complete. , White Washing Two Coats With Shell Lime , Distempering Two Coats To Wall , Wiring Of Pump Chamber , Cost Of Out Let Of Tee Tank , Cost Of 300 Mm Dia Reinforced Cement Concrete Hum Pipe( Np 3 ) As Per Specifications Including Laying & Fitting With Collars As Required. , Filling The Foundation And Plinth With Excavated Material As Directed By The Engineer-Incharge. , Filling In F&P With Excavated Materials Including Well Watered And Rammed.In Hard Soil Such As Hard Stiff Clay, Stiff Black Cotton, Hard Red Earth, Shales, Moorum Ordinary Gravels, Within 50M. Initial Lead And 1.5M. Initial Lift Including Rough Dressing And Breaking Clods And Stacking Rubble Or Spreading And Leveling Within The Site As The Case May Be Etc; Complete.Asper Direction Of The Engineer-In-Charge.(Mechanical Plus Mannual I.E. Of Item No. 5 Above) , Writing Charge Of Required Information And Data On Both Side Of The Transperancy Pillar Including Supplying Of Approved Paints And Required Material For Writing Etc. Complete As Per The Direction Of The Engineer-Incharge. , 100Mm Dia Nominal Bore G.I.Pipe Having Wall Thickness 4.5Mm Electrical Resistance Welded Of Medium Class Confirming To Is- 1239(Part-1/2004) With Latest Ammendments, Screwed At Both Ends As Per Is-554 With Socketed At One End And The Other End Protected With Plastic Threaded Protector Including Its Transportation And Unloading At L.I.P. Site. The Socket Confirming To Isi 1239(Part Ii/1992) With Latest Ammendments In Random Length Of 4 To 7 Mtr.Each Pipe Should Bear Is Certification And Manufacturers Name/Trade Mark. (As Per special repair 2022) , 100Mm Dia G.I.Bend ( Medium Duty) Conforming To Is No-1239 (Part Ii/1992) With Isi Mark Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , 100Mm Dia G.I.Flange (Medium Duty) Conforming To Is No-6392/1971 With Isi Mark Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , 100Mm Dia C.I. Screw Boss Foot Valve Of Swing Type Friction Less With Single Disc Conforming To Is-4038/1979 Of Reputed Brand With Isi Mark Of Reputed Company Having Wide Dealership Network Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst (Kirlosker Make) , Cost, Supplying Of Isi Marked High Density Polythelene (Hdpe) Pipes For Water Supply As Per Is 4984/2016 In The Following Nominal Diameter, Grades Of Materials, Pressure Rating Including The Rates Of Ex-Factory, Pre & Post Inspection, Cess Etc Complete But Excluding The Cost Of Gst Cost Of 200Mmdia Hdpe Pipe Pe 80-Pn4 , Cost, Supplying Of Isi Marked High Density Polythelene (Hdpe) Pipes For Water Supply As Per Is 4984/2016 In The Following Nominal Diameter, Grades Of Materials, Pressure Rating Including The Rates Of Ex-Factory, Pre & Post Inspection, Cess Etc Complete But Excluding The Cost Of Gst Cost Of 160 Mmdia Hdpe Pipe Pe 80-Pn4 , Transportation Of 200 Mm Dia Hdpe Pipe From Nearest Approved Manufacturing Units As Listed In Epm Rate Contract To Village Site Of The Project , Transportation Of 160 Mm Dia Hdpe Pipe From Nearest Approved Manufacturing Units As Listed In Epm Rate Contract To Village Site Of The Project , 100Mm Dia C.I.Sluice Valve Flanged Type Pn-1.0 As Per (Is-14846-2000 Standard) With Isi Mark Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst (As Per special repair 2022) , 100Mm Dia C.I.Double Flanged Non Return Valve Swing Type Pn-1.0 (Is-5312(Part-I-2004) With Bypass Arrangement With Isi Mark Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst (As Per special repair 2022) , Cost, Supplying Of 25Mm Dia Kirloskar Make C.I Single Air Release Valve (Standard) Pn 1.6 With Saddle And Raiser Pipe Conforming To Is 14845 (Si) With Isi Mark Including All Cost, Conveyance, Cess Etc Complete , Cost Of 200 X 200 X 100 Dia Weldless G.I. Tee (3.6Mm Thickness With Bend Closing And Opening Arragement Of Reputed Company , Cost Of 160 Mm X 160 Mm X 110 Mm Ø Dia Weldless G.I. Tee (3.6Mm Thickness With Bend Closing And Opening Arragement Of Reputed Company , Cost Of 100X100x25mm G.I. Tee With Plug For Priming , 219Mm Dia M.S.Pipe (6.30Mm Thickness) Is 3589:2001 With Isi Mark Of Reputed Company Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst (As Per special repair 2022) , Cost Of 12Mm Thick Ms Plate Flange 200Mm Dia Isi Mark Of Reputed Company , 200 Mm Hdpe Tail Piece 160 Mm Long , 200 Mm Slipon Flange , 160 Mm Hdpe Tail Piece 160 Mm Long , 160 Mm Slipon Flange , Cost Of Welding & Laying Fitting 200Mm M.S. Pipe , Labour Charges For Transporting Of Pipe Stockyard To Work Site,Laying ,Jointing, Fitting & Testing Of 200Mm Hdpe Pipe , Labour Charges For Transporting Of Pipe Stockyard To Work Site,Laying ,Jointing, Fitting & Testing Of 160Mm Hdpe Pipe , Labour Charges For Delivery And Fitting Including Fitting Of Priming Tee, Sluice Valve, Nr Valve, Air Release Valve And Riser Tee Etc And Installation , Cost Of Rubber Insertion 3Mm Thick , Cost Of Nut Bolt , 150Mm Dia C.I. Butter Fly Valve Bs:5155/15: Kirloskar Or Equivalent Make 13095-Ci Moc Lever Operated Pn-1.0 With Isi Mark Of Reputed Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst (As Per special repair 2022 , 200 Mm Hdpe Elbow Spigot Design 6 Kg , 160 Mm Hdpe Elbow Spigot Design 6 Kg , Cost Of 200Mmx100mm M S Reducer , 200X200x200 Mm Hdpe Tee Spigot Design 6 Kg , 200X200x160 Mm Spigot Moulded Reducing Hdpe Tee 10 Kg , 160X160x160 Mm Hdpe Tee Spigot Design 6 Kg , 200 Mm Hdpe End Cap , 160 Mm Hdpe End Cap , 12.5 Hp/9.375 Kw Energy Efficiency Monoblock Pump Set Of Total Head 24 Mtrs Having Discharge 1700 Lpm With Squirrel Cage Induction Motor Fitted With Bronze Impeller Tb-2 Of Is 318/1981, Companion Flanges & Class FInsulation Suitable For Operation 415 Volt +6%-15% 3 Phase, 50Hz Ac Poweer Supply Suction/Deliveery= 100Mmx100mm With Bee 3 Star Rated Energy Efficiency Pump & As Per Is-9079/2002 With Overall Efficiency 62 To 65% Of Reputed Brand Having Wide Dealership Net Work For Easy Availability Of Spares Confirming To Is Specification (A) Casing: Fc 200 As Per Is 210/1978 (B) Impeller: Bronze Grade Ltb-2 Of Is 318/1981 Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , Automatic Star Delta Starter Sheet Steel Enclosure Suitable For Operation Of Squirrel Cage Induction Motor Upto 15 Hp (13-20) With 16. annual periodical maintenance (Ac-3) Contactor At 415 Volt +6%-15%, 3 Phase, 50 Hz, Ac Supply With Suitable Overload Relay & No Volt Coil With Electric Pnemutic Timer Suitable For Operation At Voltage Range Of 300-440 Volt Including Cost Of Transportation To Site The Starter Should Provide Dependable Protection Against Overload And Single Phasing & Should Be Of Reputed Brand Having Wide Dealership Network For Easy Availability Of Spares Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , 63 annual periodical maintenance Triple Pole Mainswith Confirming To Is No.4064(Part I & Ii) With Isi Marking Of Reputed Company Having Utilisation Capacity Cagegory Ac- 22 Reputed Brand Of Isi Specification Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , Empty Outdoor Irrigation Pannel Board Size (0.45Mtx0.25Mtx1.20M Of 18 Swg Cold Rolled M.S Sheet With 4 Legs Of 300 Size With One Coat Of Red Oxide Primer And Two Coats Of Smoke Grey /Navy Blue Two Coats Of Powder Coated Paint Of Approved Quality On Both Side (Inside & Outside) Suitable To Mount 3Phase Starter, Main Switch And Capacitor Inside The Panel Board Vertically Over 18 Swg M.S.Sheet And The Danger Board Fixed On The Top Of The Panel Doorreputed Brand Of Isi Specification Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , Motor Hood Size (0.45Mx0.45Mx0.60M) Made With 18 Swg (Cold Rolled M.S.Sheet With One Coat Of Red Axide Primer And Two Coats Of Powder Coated Paint Of Approved Quality On Both Side (Inside & Outside) Suitable To Cover Centrifugal Monoblock Pump Set From 10 Hp To 15 Hp And Having Provision For Attachement With The Groves On Rear Side Of The Pannel Board Of Approved Brand Including All Cost, Conveyance, Cess Etc Complete As Per The Direction Of The Engineer-In-Charge But Excluding Cost Of Gst , Motor Base Plate Made With M.S Angle With One Coat Of Red Axide Primer And Two Coats Of Powder Coated Paint Suitable To Cover Centrifugal Monoblock Pump Set From 10 Hp To 15 Hp And Having Provision For Hole For Fixing Nut & Bolt Of Approved Brand Including All Cost, Conveyance, Cess Etc Complete As Per The Direction Of The Engineer-In-Charge But Excluding Cost Of Gst , 4Kvar Power Shunt Capacitor With Isi Mark Of Of Reputed Approved Brand Of Isi Marked Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst , Cost Of 3/16Mm2 T.D Cabel , Cost Of Other Petty Materials Like Connection Wire And Cabel Laying In Trench & Energisation , Electrical Installation , Tranporation, Energisation & Including By Party Agreement. , Kit Bag Including Plyer, Tester, Slide Range, Screw Driver, Hand Gloves All Are In Taparia Make To Be Hahded Over To The Panipanchayat , Cost Of Electrical Earthing , Construction And Erection Of 11/0.416 Kv 25 Kva Star Rated Dp Sub-Stationconfirming To Re Rule 1956. Mounted On 2.44 Mt Long Structure, Supported On 10 Mt Long Psc Pole, Transformer Hard Channel & Top Channel Made Of 2.8 Mtr Long 100X50x6 Mm Size Ms Channel, Transformer Belting On 2.80 Mtr Long 50X50x5mm Size M.S. Angle, (All Recspn. Std. F-3), With All Accessories Like, 3 Pole 11 Kv H.G. Fuse (F-5) Abd Ab Swithces (F-9) Both Mounted On 2.8 Mtr Long 75X40x6 Mm Size M.S. Channel And Supported By 1.0 Mtr Long 50X50x5 Mm M.S. Angle, With 3 Nos. 11 Kv Lightening Arrestor & Distribution Box For 25 Kva S/S Mounted On Box ( 75X40x6 Mm) To 2.5 Mtr Long Pipe Earthing (F-2) Including Cost Of 50 Sq Mm 3.5 Core Lt Cable Connecting The Supply Line With 55 Sq Mm Aaa Conductor, Providing G.I. Ht Stay As Required Carping & Padding Of Poles, Danger Board At Each Pole. ., Complete As Per The Direction Of The Site Engineer Incharge. , Construction Of 3 Phase 11 Kv Line As Per Rec Stanard Confirming To Re Rules 1956 With 10 Mt Long Psc Pole Support In 50 Mtr Span, 55 Sq Mm Aaa Conductor, 11 Kv V Cross Arm, With Required No Of 11 Kv T & C Disc. Insulators & 11 Kv Pin Insulators, Carping & Padding Of Poles, Danger Board At Each Pole, Anti Climbing Devices, Stay Set At Bending Point And Double Stay At End Point With 18 Mm G.I. H.T Stay, Concreting Of Stay With Anchor Plate Guarding At Road Crossing Etc., Marking Olic In Every Psc Pole In Enamale Paint Including Cost Of All Materials. With Ab Switch & Interposing Pole, Labour Trasportation, Inspection And Commissioning With Cut Point Etc., Complete As Per The Direction Of The Site Engineer Incharge. , Construction Of 3-Phase, 4-Wire Lt Line As Per Rec Standard Confirming To Re Rules 1956, With 9 Meter Long Psc Pole Support In 50 Meter Span, 3X35+1X25 Sqmm Ab Cable, Required Numbers Of 16 Mm Lt Gi Stay-Set At Bending Point And Double Stay At End Point With Required Numbers Of Suspension Clamp,Dead End Clamp And Lt Stay Insulator, Providing Coil Earthing At Each Pole ,Carping And Padding Of Poles, Danger Board At Each Pole With Anti-Climbing Device Etc. Including Cost Of All Other Fittings, Petty Materials, All Labours, With Liaison For Inspection And Commissioning& Writing On The Pole As Per Prescribed Colour Code, Etc, Complete As Per The Direction Of The Site Engineer In Charge .
|