Tender for Earth Work Excavation For Foundation By Mechanical Means For Isolated & Combined Footing Etc In All Soils And Sub-Soils And To Full Depth As May Be Directed Except In Rock Requiring Blasting Inclusive Of Shoring Shuttering, Bailing Out Water Wherever Necessary And Depositing The Surplus Earth Within The Compound In Places Shown By The Departmental Officers With An Initial Lead Of 100 Mts And Clearing And Levelling Including Dressing Of Sides And Raming Of Bottoms Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers.- Upto 2.40M Footing Depth. Data Worked Out For 48 M3 Per Day/8 Hrs. , Earth Work Excavation For Foundation By Mechanical Means For Isolated & Combined Footing Etc In All Soils And Sub-Soils And To Full Depth As May Be Directed Except In Rock Requiring Blasting Inclusive Of Bailing Out Water Wherever Necessary And Depositing The Surplus Earth Within The Compound In Places Shown By The Departmental Officers With An Initial Lead Of 100 Mts And Clearing And Levelling Including Dressing Of Sites And Raming Of Bottoms At The Site, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. A. For Footing Depth 2.40M To 3.3M Data Worked Out For 54 M3 Per Day/8 Hrs.-A. For Footing Depth 2.40M To 3.3M , Earth Work Open Excavation By Mechanical Means For Open Earthwork In All Soils And Sub-Soils And To Full Depth As May Be Directed Except In Rock Requiring Blasting Inclusive Of Shoring Shuttering, Bailing Out Water Wherever Necessary And Depositing The Surplus Earth Within The Compound In Places Shown By The Departmental Officers With An Initial Lead Of 100 Mts And Clearing And Levelling Including Dressing Of Sides And Raming Of Bottoms Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. A). Upto 2.40M Depth. Data Worked Out For 64 M3 Per Day/8 Hrs. , Cement Concrete 1:5:10 (One Cement, Five Crushed Stone Sand And Ten Hard Broken Stone Jelly) Using 40 Mm Gauge Hard Broken Granite Stone Jelly For Foundation Including Dewatering Wherever Necessary And Laid In Layers Of Not More Than 15 Cm Thick Well Rammed, Consolidated And Including Curing Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. -Mixing By Manual Means , Supplying And Filling In Foundation, Basement, Etc With Filling Crushed Stone Sand In Layers Of Not More Than 15 Cm Thick Well Watered, Rammed And Consolidated Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Supply And Filling In Foundation And Basement With Gravel In Layers Of Not More Than 15Cm.Thick Well Rammed Watered And Compacted With Surface Vibrator, Watered And Consolidated Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Supplying And Filling In Foundation, Basement, Etc With Conveyed Earth In Layers Of Not More Than 150Mm Thick Layers Well Watered, Rammed With Surface Vibrator And Consolidated Including Conveyance Charges Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Refilling With Excavated Earth Other Than Sand With An Initial Head Load Of 100 Mts. And Depositing The Earth As Shown By The Departmental Officers In Layers Of Not More Than 15Cm Thick Well Rammed With Surface Vibrator, Watered And Consolidated Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Cement Concrete 1:5:10 (One Cement, Five Crushed Stone Sand And Ten Hard Broken Stone Jelly) Using 40 Mm Gauge Hard Broken Jelly For Flooring Including Laying, Consolidating, Finishing, Rendering The Top Surface Rough To Receive The Floor, Curing, Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. (The Rate Is Inclusive Of Necessary Planking For Panelling Wherever Necessary And As Directed By The Departmental Officers -Mixing By Manual Means , Brick Work In Cement Mortar 1:3 Using Best Quality Fly Ash Brick Of Size 230X110x70mm With Class Designation Of 7.5 Conforming To Is 13757-1993 Or Is 12894-2002 Including Cost Of Mortar Plasticizer, Curing, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. Brickwork Shall Be Done As Per Is 2212-1991 Adopting English Bond Generally. Other Type Of Bond Shall Be Done As Directed By The Executive Engineer In Charge.-For Foundation & Basement , Brick Work In Cement Mortar 1:5 Using Best Quality Fly Ash Brick Of Size 230X110x70mm With Class Designation Of 7.5 Conforming To Is 13757-1993 Or Is 12894-2002 Including Cost Of Mortar Plasticizer, Curing, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. Brickwork Shall Be Done As Per Is 2212-1991 Adopting English Bond Generally. Other Type Of Bond Shall Be Done As Directed By The Executive Engineer In Charge. , For Foundation & Basement , In Ground Floor , Brick Partition Walls Of 11.50Cm Thickness Using Best Quality Fly Ash Brick Of Size 230X110x70mm With Class Designation Of 7.5 Conforming To Is 13757-1993 Or Is 12894-2002 In Cement Mortar 1:3 (One Cement And Three Cs Sand) Using Hoop Iron Reinforcement If Found Necessary Including Cost Of Mortar Plasticizer, Curing Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. (Hoop Iron Reinforcement Will Be Measured And Paid For Separately)-In Ground Floor , Damp Proof Course As Per Is 3067:1988 With Cement Mortar 1:4 (One Cement And Four Crushed Stone Sand) 12Mm Thick Mixed With Best Approved Quality Integral Liquid Water Proofing Compound Conforming To Indian Standard Specification As Specified By The Departmental Officers At 2% By Weight Of Cement Used , Finishing And Curing Etc. Complete Complying With Standard Specification - Manual Mixing , Supplying And Erecting Steel Centering Including Necessary Supports For Plane Surfaces For Reinforced Cement Concrete Works Such As Column Footings, Column Pedestals, Plinth Beams, Grade Beams, Staircase Steps, Sill Slabs Etc. Which Require Only Nominal Strutting Using Mild Steel Sheets Of Size 90Cm X 60Cm And 10 Bg Stiffened With Welded Mild Steel Angles Of Size 25Mm X 25Mm X 3 Mm For Boarding, Laid With Silver Oak Joists Of Size 10Cm X 5Cm & 7.5Cm X 5Cm As Support Runner , Vertical Stiffener , Side Support And Top Horizontal Stiffener Spaced At About 60Cm To 90Cm Centre To Centre Or At Suitable Intervals Etc. Complete In All Floors Complying With Standard Specifcation. (Payment For Centering Shall Be Given After The Concrete Is Laid). , Supplying And Erecting Centering For Plane Surfaces Such As Reinforced Cement Concrete Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks Etc.. With Necessary Supports And Strutting Upto 3.60M Height In All Floors With All Cross Bracings Using Ms Sheets Made Of 10 Gauge Thick Welded With Ms Angle Of Size 25Mm X 25Mm X 3Mm For Boarding Laid Over Steel Adjustable Span Of Size 2M X 2M(Expandable Upto 3.60M) And Silver Oak Joists Of Size 10 X 5 Cm Spaced At 50Cm To 60Cm C/C And Supported By Steel Adjustable Telescopic Props Of Size 2M X 2M (Expandable Upto 3.60M) Made With Outer Steel Pipe With Dia 50Mm (3.60Mm Thick) And Inner Steel Pipe With Dia 40Mm (2.90Mm Thick) Spaced At Not More Than 50 To 60Cm C/C , Etc Complete Complying With Standard Specifications. Steel Adjustable Span And Steel Adjustable Telescopic Props Shall Be Provided As Directed By The Departmental Officers. (Payment For Centering Shall Be Given After The Concrete Is Laid). , Supplying And Erecting Steel Centering Including Necessary Supports For Plane Surfaces Such As Rectangular Or Square Reinforced Cement Concrete Columns Etc. Which Require Only Nominal Strutting Using Mild Steel Sheets Made Of 10 Gauge Thick Welded With Ms Angle Size 40Mm X 40Mm X 5 Mm And Supported By Steel Adjustable Telescopic Props Of Size 2M X 2M (Expandable Upto 3.60M) Made With Outer Steel Pipe With Dia 50Mm (3.60Mm Thick) And Inner Steel Pipe With Dia 40Mm (2.90Mm Thick).Etc..Complete In All Floors Complying With Standard Specifcation. Steel Adjustable Telescopic Props Shall Be Provided As Directed By The Departmental Officers. (Payment For Centering Shall Be Given After The Concrete Is Laid). , Supplying And Erecting Centering For Sides And Soffits Including Necessary Supports And Strutting Upto 2.10 M Height For Plane Surfaces As Detailed Below In All Floors With All Cross Bracings Using Mild Steel Sheets Of Size 90 X 60 Cm And 10 Bg Stiffened With Welded Mild Steel Angle Of Size 25Mm X 25Mm X 3 Mm For Boarding Laid Over Silver Oak Joists Of Size 10Cm X 6.50 Cm Spaced At Abote 90 Cm Centre To Centre And Supported By Casurina Props Of 10Cm To 13 Cm Dia Spaced At Not More Than 75 Cm Centre To Centre Etc. Complete Complying With The Standard Specificaiton And As Directed By The Departmental Officers(Payment For Centering Shall Be Given After The Concrete Is Laid) , Centering For Curved All Reinforced Cement Concrete Surfaces Upto 2.10 M Height , Providing And Laying In Position, Standardised Concrete Mix M-20 Grade By Insitu Machine Mix Concrete Adopting Weighing Batch Method In Accordance With Is 456 Using 20Mm And Down Graded Hard Broken Granite Stone Jelly For All Reinforced Cement Concrete Items Of Works With Minimum Cement Content Of 325 Kg/M3 And Maximum Water Cement Ratio Of 0.55, Including Admixture (Plasticiser / Super Plasticiser) In Recommended Proportions As Per Is:9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability With About (5 Cu.M.) 7730 Kg. Of 20Mm Machine Crushed Stone Jelly And With About (3.3 Cu.M.) 5156 Kg. Of 10-12Mm Machine Crushed Stone Jelly And With About (4.79 Cu.M) 7670 Kg. Of Crushed Stone Sand, But Excluding Cost Of Reinforcement Grill And Fabricating Charges, Centering And Shuttering And Also Including Laying, Vibrating With Mechanical Vibrators, Finishing, Curing, Etc. And Providing Fixtures Like Fan Clamps In The Reinforced Cement Concrete Floor/ Roof Slabs Wherever Necessary Without Claiming Extra, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. The Coarse And Fine Aggregates To Be Used Should Comply With The Requirements Of Is Standards. (No Separate Payment Will Be Made By The Department For The Excess Usage Of Materials). , In Foundation And Basement , In Ground Floor , Manufacturing, Supplying And Fixing Precast Reinforced Cement Concrete Slabs Of 50Mm Thickness In Reinforced Cement Concrete 1:2:4 (One Cement, Two Crushed Stone Sand And Four Aggregates), Using 20Mm Hbgs Jelly Excluding Cost Of Reinforcement Steel In Position But Including Cost Of Moulding Charges, Casting Of Slab, Finishing, Curing And Fixing In Position In All Floors Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers.50Mm Thick Precast Slab , Supplying, Fabricating And Placing In Position Mild Steel / Ribbed Tor Steel Reinforcement Grills Of All Variety Like Hysd/Ctd/Tmtand All Grade Like Fe 500, Fe550d, Fe 500 D Etc., For All Reinforced Cement Concrete Works As Per Design Given Including Cost Of Steel Reinforcement And G.I. Binding Wire, Wastage Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers.(Contractor Has To Make His Own Arrangements For The Supply Of Steel Reinforcement And Binding Wire) , For Foundation And Basement , In Ground Floor , Plain Cement Concrete 1:2:4 (One Cement, Two Crushed Stone Sand And Four Hard Broken Stone Jelly) Using 20Mm Jelly For Wearing Coat Including Laying, Compacting, Finishing And Curing, Etc., Complete As Per Standard Specificatins And As Directed By The Departmental Officers.- Mixing By Manual Means -In Foundation And Basement , Weathering Course In Brick Jelly Lime Concrete Using Broken Brick Jelly Of Size 20Mm Uniform Gauge In Pure Slaked Lime (No Crushed Stone Sand To Be Used) To The Proportion Of Brick Jelly To Lime Being 32:12.5 By Volume And Laid Over The Reinforced Cement Concrete Roof Slab In A Single Layer Of Required Slope And Finished By Beating The Concrete With Wooden Beaters Of Approved Pattern, Keeping The Surface Constantly Wet By Sprinkling Lime Jaggery Water, Etc., Complete As Per Standard Specification And As Directed By The Deparmental Officers.-In Ground Floor , Finishing The Top Of Slopped Roof, Sun-Shade With Machine Pressed Ornamental / Decorative Tiles Of Approved Quality Laid In Cement Mortar 1:3, 20Mm Thick Mixed With Wpc At 2% By Weight Of Cement Used And Top Pointed With The Same Red Oxide Mixed Mortar Etc Complete, Complying With Standard Specifications And As Directed By The Departmental Officers. , Paving The Floor With Best Quality Double Charged Vertified Tiles 1200X 600 X 10Mm Of Approved Colour, Shade And Quality Laid In Cement Mortar 1:3 (One Cement And Three Sand) 20Mm Thick In All Floors With 3Mm Spacer And The Top Pointed With The White Cement Mixed Same Colour Pigments Etc., Complete Complying With Standard Specification. (The Make And Brand Of The Tiles Should Be Got Approved By Executive Engineer Before Use On Works) , Flooring With Italian Marble Slab Of Size 1200 X 600 Of 16 / 18Mm Thick And Above Free From All Defects In All Floors Over A Base Layer Of Cm 1:3, 20Mm Thick. The Marble Slab Shall Be Laid Over The Cement Mortar By Applying White Cement Slurry In Between Base Mortar And Marble Slab And Pointed With White Cement Neatly Including Polishing With Polishing Stone And Oxalic Acid, To Get Perfectly Smooth And Glossy Finish. Including Hire Charges For Polishing Machine And Power Consumption Charges Etc. The Marble Slabs And Other Materials To Be Used Shall Be Got Approved By The Executive Engineer Concerned Before Use On Work, Etc., Complete. , Paving The Floor With Best Approved Quality Leather Finished Granite Slab Jet Black Of 18-20Mm Thick With Machine Cut Edges Laid Over A Cement Mortar Bed Of 20Mm Thick Using Cement Mortar 1:3 (One Cement And Three Crushed Stone Sand) Fixing The Slabs With Required Cement Slurry And Laid In True Right Angles With Minimum Possible Width Of Joints And Pointing The Joints With White Cement Mixed With Mathcing Colouring Pigments Etc., The Granite Stone Slabs And Other Materials To Be Used Shall Be Got Approved By The Executive Engineer Concerned Before Use On Work, Etc., Complete As Per Standard Speicification. , Providing Full Nosing To The Steps Or Platforms To The Granite Slab Of 20Mm Thick Including Neat Finishing, Polishing, Cost Of Powder, Tools Etc As Directed By The Departmental Officers , Flooring With Self Designed Colour Ceramic Tiles Of Size 305 X 305 X 6Mm Of Following Size And Variety Conforming To Is 15622 Laid Over Cement Mortar Bed Of 20 Mm Thick In Cement Mortar 1:3 (One Cement And Three Crushed Stone Sand) With Required Cement Slurry And Mortar Plasticizer Including Cutting The Tiles To The Required Size With Special Cutter Wherever Necessary, Laying In Position And Pointing With Water Resistant Tile Epoxy Grout At The Rate Of 0.27 Kg. / Sq.M. Etc., Complete Complying With Standard Speci?cation And As Directed By The Departmental Of?cers. (The Make And Brand Of The Tiles Should Be Got Approved By Executive Engineer Before Use On Works) , Dadooing Ceramic Tiles Of Size 300Mm X 600Mm X10mm Best Approved Quality, White / Colour Glazed Tiles Set In Cement Mortar 1:2 (One Cement And Two Sand) 10Mm Thick And Pointing The Joints With White Cement Mixed With Colouring Pigments At The Rate Of 0.40 Kg. /Sq.Mneatly In All Floors, Curing, Etc., Complying With Standard Specification And As Directed By The Departmental Officers. , Dadooing With Granite Tiles Of Jet Black Of Suitable Sizes Of Granite Tiles - (Superfine Polished With Machine Cut Edges) Of Size 20 X 10 Or 10 X 10 Or 10 X 06 Of 10 Mm Thick With Machine Cut Edges Laid Over A Cement Mortar Bed Of 20Mm Thick Using Cement Mortar 1:3 (One Cement And Three Sand) Fixing The Slabs With Required Cement Slurry And Laid In True Right Angles With Minimum Possible Width Of Joints And Pointing The Joints With White Cement Mixed With Mathcing Colouring Pigments Etc., The Granite Stone Slabs And Other Materials To Be Used Shall Be Got Approved By The Executive Engineer Concerned Before Use On Work, Etc., Complete As Per Standard Speicification. , Supply And Fixing Of Natural Granite Stone Piller Of 300 Mm Dia With Base Size 550X550x900mm Thick At Bottom With Curving To Be Laid As Per Design Or Directed By Departmental Officers. The Granite Stone Piller And Other Materials To Be Used Shall Be Got Approved By The Executive Engineer Concerned Before Use On Work, Etc., Complete As Per Standard Speicification. , Paving The Floor With Pre-Polished Concrete Anti-Skid Tiles (Required Shape And Design) Of 20Mm Thick Of Approved Quality And Colour Laid In Cement Mortar 1:3 (One Cement And Three Sand) 20Mm Thick And Pointed With White Cement Mixed With Colouring Pigment At The Rate Of 0.40 Kg. / Sq.M., Curing, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Supply And Fixing The Paving Dry Stone Floor With Sadharhali Stone Slab Of Size 1200X300 And 300X300x70mm Thick To Be Laid As Per Design Or Directed By Departmental Officers In Flamed Finish Including Cutting And Levelling The Earth For Landscapping Area Etc., All Completed Complying With Standard Specification. , Providing Granolithic Floor Finish Of The 25Mm Thickness With Plain Cement Concrete 1:2:4 (One Cement, Two Sand And Four Aggregate) Using 10 To 12Mm Gauge Hard Broken Stone Jelly Including Laying, Finishing And The Top Rubbed Smooth With Power Trawl, Thread Lining, Curing Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. (The Rate Is Inclusive Of Necessary Planking For Panelling Wherever Necessary And As Directed By The Departmental Officers)-For 25Mm Thick , Supplying And Fixing In Position Best Approved Of Bis Quality 160Mm Dia Pvc Rain Water Down Fall Pipes Various Dia Having A Pressure Of 4 Kg. / Sq.Cm Including Cost Of Necessry Pvc Shoe, Pvc Bend, Cast Iron Gratings Of Required Diameter And Special Clamps, Brass Screws, Nails, Etc., And Fixing Of Cast Iron Gratings At Junction Of Parapet And The Reinforced Cement Concrete Roof Slab Including Finishing Neatly Etc., Complete. The Rate Shall Be Inclusive Of Cast Of Removable Cast Iron Grating. The Pvc Pipe Shall Be Fixed In Wall With Special Type Of U Clamp At The Centre Of The Pipe Line In Addition To Those For More Than 3.0 Metre Pipe Length, Etc., Complete Complying With Standard Specification. , Supplying & Fixing Of Wpc (Wood Polymer Composite) Door, Frame Extruded With Size 75Mm X 50Mm. The Single Core Door Made Of Rigid Wpc Compound With Minimum Bulk Density Of 900 Kg/ Cub.Mt. & Shore Hardness Of 55. Supplying & Fixing Of Wpc Door Shutter, Extruded As A Single Core Board With Rigid Wpc Compound With The Thickness Of 25Mm (+/- 1Mm) & Minimum Bulk Density Of 550 Kg/ Cub.Mt. & Shore Hardness Of 55. For The Aesthetic Appearance, The Door Shall Be A Printed Digitally On One Side Of The Shutter. The Wpc Door Shall Be Fixed Onto The Wpc Frame With 3 Nos Of 5 Ss Hinges And The Door Shall Have 2 Towerbolt On One Side And 1 Towerbolt Or Aldrop On Other Side For Locking System And 2 Numbers Of Handle On The Either Side Of The Door Shutter, All Made Of Aluminium.The Rate Is Inclusive Of All Materials, Labours, Conveyance And Fixing In Position With All Other Incidential Charges Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officer.( The Materials Quality,Brand, Colour, Shade Should Be Approved By The Executive Engineer Before Use On Works). , Upvc Window Specification: Supplying And Fixing Upvc (Un-Plasticized Polyvinyl Chloride) Windows Of Casement Type (Open) From The Profile The Size Of Outer Frame 60Mm X 58Mm And Shutter Profile Are Reinforcement With Gi/1Mm 125Gsm And 100% Corrosion Free, The Profiles Are Multi Chambered Sections With Wall Thick Of 2Mm. The Epdm Rubber (Black Colour) Covered With Over All The Edges Of Frame And Shutter The Shutter Will Be Provided With Espag Multi Power Point Locks And Also It Operates As Handle. The Corners And Joints Should Be Welded And Cleaned. Radiations Free Pin Headed Plain Or Brown Colour Glass 4Mm Thick Should Be Provided To The Shutter And It Should Not Allow Leakage Of Water Even At Most Ranging Storms And Should Have Key Lockable Action, Security Protective Hinges, Strong Locking Systems And As Per Size For Arresting Noise And Energy Loss. The Connecting Mechanism Between Sash And Outer Frame That Enables Opening Of The Window. The Window Should Be Fixed To The Wall With 100% Packing With Screws And Silicon Packing All Round The Frames. The Window Should Be Got Approved From The Executive Engineer Before Use On Work , Upvc Ventilator Specification: Supplying And Fixing Upvc (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators Of From The Profile The Size Of Outer Frame 60Mm X 58Mm And Shutter Profile Size Of 60 X 78Mm Both Profiles Are Reinforced With Gi/1Mm 125Gsm And 100% Corrosion Free, The Profile Are Multi Chambered Sections With Wall Thick Of 2Mm. The Epdm Rubber (Black Colour) Covered With All Over The Edges Of Frame And Shutter. The Corners And Joints Should Be Welded And Cleaned. Radiations Pin Headed Glass 4Mm Thick Should Be Provided In The Louvers. The Window Should Be Fixed To The Wall With 100% Packing With Screws And Silicon Packing All Round The Frames. The Ventilator Should Be Got Approved From The Executive Engineer Before Use On Work , Manufacturing Supplying And Fixing Of Steel Door Single Leaf With The Following Specification Ms Angels Of Size 40X40x6mm Are Used For The Outer Frames And M.S. Angles Of Size 35X35x5mm For The Shutter Frames Stiffeners With 32 X 6Mm M.S Flat Is Provided At Required Intervals In The Shutter Frame. 18-Gauge C.R. Sheet Laid As Panel In The Shutter And Welded Intact. M.S. Flat 18X5mm Is Welded Over The 32 X 6Mm M.S. Flat Sandwitching The C.R. Sheet In Between Additional Stiffeners With 18X5mm M.S. Flat Is Provided Diagonally At The Rear Side Of The Shutter, 3Nos. Of Hinges In Case Of Single Leaf And 6Nos. Of Hinges In Double Leaves Shutter To Be Provided 6Nos. Of Holdfasts 120 Mm In Length Made Of Angle Section Spliced At The Ends Are Welded To The Outer Frames Of The Door. Tower Bolts 2Nos. One At The Top And The Other At The Bottom Are Provided 1No. Aldrop Is Provided Incase Of Double Leaf Door At Lock Rail Section In The Door In Single Leaf Door, One More Aldrop Is Provided In The Inner Lock Rail Section Of The Door One Rotaing Locking Arrangements For The Inner Side Of The Door And Additional Provision For Locking Arrangements For Lock Is Provided On The Rear Side Of The Door At An Appropriate Place. Incase Of Double Leaf Door M.S.Flat 32 X 3Mm At 1.1Kg/M Is Provided On The One Shutter T Conceal The Gap Between The Two Shutters.At An Appropriate Place In The Door. , A Tie Bar Is Provided At The Bottom Of The Frame To Prevent Twisting Of Frame During Transportation And Fixing. All Members Are Given A Coat Of Red Oxide Primer As Directed By The Departmental Officers. The Rate Includes Cost Of All Materials, Labour Charges, Transportation To Site Of Work, Loading, Un Loading And All Other Incidental Charges Etc., Complete.-Single Leaf , Supplying And Fixing Of M.S.Grill Of Approved Design For Grill Gate, Grill Work To Doors And Windows Openings Ramp Etc., Using Necessary Mild Steel Flats For Inner And Outer Members Which Should Be Fixed On Edges Including Priming Coat Of Best Approved Quality Red Oxide Primer Etc., Complete Complying With Standard Specification. , Supplying And Laying Rubber Moulded Hydraulic Pressed Paver Block Of 83Mm Thick Approved Design Made Out Of 6 - 10Mm Thick Hbgs Chips In Cm 1:2:4 Properly Occurred To Attain The Required Strength Laying The Rubber Moulded Paver Block Over A Sand Cushion Of 10Cm Thick And Well Compacted Using 1-3 Tonne Capacity Of Manufacturing The Inter Locking Blocks , Loading, Transportation , Unloading And Other Incidential Charges Etc. Complete Complying With Standard Specification , Plastering With Cement Mortar 1:5 (One Cement And Five Sand), 12Mm Thick In All Floors Including Curing Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Special Ceiling Plastering And Finishing The Exposed Surface Of All Reinforced Cement Concrete Items Of Work Such As Slabs, Beams, Sunshades, Facia, Canopy Slab, Staircase Waist Slab, Landing Slab Etc., With Cement Mortar 1:3 (One Cement And Three Sand) 10Mm Thick Used Finishing Including Hacking The Surfaces, Providing Cement Mortar Nosing, Beading For Sunshades, Staircases, Steps, Landing Slabs And Curing, Etc., In All Floors Complying With Standard Specification And As Directed By The Departmental Officers , Plastering The Surface Of Walls With Cement Mortar 1:3 (One Cement And Three Sand), 12Mm Thick Used Finishing In All Floors Including Curing Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Painting Two Coats Of Newly Plastered Wall Surface With Ready Mixed Plastic Emulsion Paint Of First Class Quality And Of Approved Colour Over A Priming Coat Including Thorough Scrapping, Clean Removal Of Dirt, And Including Necessary Plaster Of Paris Putty, Wherever Required Etc., Complete Complying With Standard Specification. , Painting The Wall Two Coats With Approved Weather Proof Exterior Emulsion Paint Over One Primer Coat Of Over Cement Plastered Wall Surface Ect., Complete Complying With Standard Specification. , Painting New Iron Works Such As Steel Doors, Windows, Ventilators, Window Bars, Balustrades Etc., With Two Coats Of Best Approved First Quality And Colour Of Synthetic Enamel Paint Over The Existing Red Oxide Priming Coat In All Floors Excluding Cost Of Priming Coat Etc., Complete Complying With Standard Specification. , Supplying, Laying And Jointing Cpvc Pipes Of Standard Dimension Ratio 11 (Pressure Class 1) Conforming To Is:15778 - 2007 Of Approved Quality And Best Variety Of The Following Dia Including Cutting And Fixing Cpvc Specials Using Cpvc Adhesives (Solvent Cement) (But Excluding Cost Of Such Specials) And Fixing Into Wall With Teak Wood Plugs, Cpvc Clamps And Screws Making Holes On The Wall (Or) Drilling Holes In The Roof And Making Good The Dismantled Portion To Original Condition With Necessary Brick Work / Cement Concrete And Plastering Neatly Wherever Necessary With Necessary Scaffolding Charges, Etc., Complete Complying With Standard Specifications And As Directed By The Departmental Officers. (The Cpvc Pipes Shall Be Got Approved By Executive Engineer Before Use On Works) - Internal Water Supply Above Ground Level.25 Mm Dia Cpvc Pipe , Supplying Cpvc Specials Of Sdr 11 Conforming To Is 17546-2021 In Water Supply Arrangements (Both In Internal And External Water Supply Arrangements , 25 Mm Dia Cpvc Elbow , 25 Mm Dia Cpvc Tee , 25 Mm Dia Cpvc Union , 25 Mm Dia Upvc Nipple , Supplying, Laying And Jointing Upvc Pipes Of Class 6 (Having Working Pressure Of 10 Kg/Sq.Cm) Conforming To Is 4985- 2000 Of Approved Quality And Best Variety Of The Followingdia Including Cutting And Fixing Upvc Specials Using Upvc Adhesives (But Excluding Cost Of Such Specials) In Accordance With Is 7634-3 (2003) And Fixing Into Wall With Teak Wood Plugs, Pvc Clamps And Screws Making Holes On The Wall (Or) Drilling Holes In The Roof And Making Good The Ismantled Portion To Original Condition With Necessary Brick Work / Cement Concrete And Plastering Neatly Wherever Necessary With Necessary Scaffolding Charges Upto 4 Metre Height Above Ground Level, Etc., Complete Complying With Standard Specifications. The Pvc Pipes Shall Be Got Approved By Executive Engineer Before Use On Works - External Water Supply Above Ground Level , 25 Mm Dia Upvc Pipe , 32 Mm Dia Upvc Pipe , 40 Mm Dia Upvc Pipe , 50 Mm Dia Upvc Pipe , Supplying Upvc Specials (With Working Pressure 10 Kg. / Sq.Cm.) In Water Supply Arrangements (Both In Internal And External Water Supply Arrangements , 25 Mm Dia Union , 32 Mm Dia Union , 40 Mm Dia Union , 50 Mm Dia Union , 25 Mm Dia Elbow , 32 Mm Dia Elbow , 40 Mm Dia Elbow , 50 Mm Dia Elbow , 25 Mm Dia Tee , 32 Mm Dia Tee , 40 Mm Dia Tee , 50 Mm Dia Tee , 32 X 25 Mm Dia Reducer , 25 X 20 Mm Dia Reducer , 20 X 15 Mm Dia Reducer , Supplying And Fixing In Position First Quality And Approved Variety Of Gun Metal Gate Valve / Wheel Valve With Bis Make Of The Following Dia Including Cost Of Shellac, Thread Balls, Etc., Complete Complying With Standard Specifications (For Both Internal And External Water Supply Arrangements). The Valves To Be Used On Work Shall Be Got Approved By The Executive Engineer Before Use On Work. , 25 Mm Dia G.M. Gate Valve , 32 Mm Dia G.M. Gate Valve , 40 Mm Dia G.M. Gate Valve , 50 Mm Dia G.M. Gate Valve , Supplying And Fixing In Position White Glazed European Water Closet 10 Litre Capacity Pvc Flushing Tank Fixed On To Wall Of Best Quality And Approved Make With 100 Mm P Or S Trap Connecting With Pvc Pipe Of 110Mm Dia, Double Flapped Rigid Pvc Black Seat And Seat Cover With Cp Brass Hinges Including Cost Of White Cement, Cement For Packing, Spun Yarn, Teak Wood Plugs, Brass Screws, Etc., Including Supplying And Fixing 10 Litres Capacity Pvc / 12.5 Litres Capacity Porcelin Low Level Flushing Tank With A Pair Of Ci Brackets, Etc., Complete With All Fittings Such As 15Mm Brass Ball Valve With Polythene Float With Brass Handle, Union, Coupling Connected By Means Of 40Mm White Pvc Flush Hand Using Indian Adopter Joint Including All Internal Fittings Such As 15Mm Brass Connections, 15Mm Gm Wheel Valve, 15Mm Brass Nipple (2 Nos.), 15Mm Nylon Connection, Tw Plugs, Screws And Also Giving Necessary Connection To The Pvc Pipe Including Cost Of 600Mm Length Of 110Mm Dia Pvc Pipe And Painting The Ci Brackets With 2 Coats Of Approved Paint Over One Coat Of Red Oxide Primer, Dismantling The Masonry And Re-Doing The Dismantled Masonry To Original Condition Etc. Complete Complying With Standard Specifications. Colour Glazed European Water Closet With 10 Litre Capacity Pvc Flushing Tank Fixed With Ci Brackets , Supplying And Fixing In Position Best Quality And Approved Make Indian Made White / Colour Glazed Earthernware Wash Hand Basin Of Size 550 X 400Mm (With Pedestal / Without Pedestal) With A Pair Of Cast Iron Brackets, Including Cost 15Mm Dia Brass Cp Pillar Tap, 32Mm Dia B Class Gi Waste Pipe With Rubber Plug And Chain, 15Mm Dia Gm Wheel Valve, 15Mm Brass Nipple, 15Mm Dia Nylone Connection, 32Mm Dia Cp Brass Waste Coupling Including Fixing Of Wash Basin Using Ci Brackets On To The Wall In Position With Tw Plugs And Screws, Rubber Washers, White Lead And Giving Necessary Water Supply Connection And Painting The Brackets With Two Coat Of Painting Over A Priming Coat Of Anti-Corrosive Paint Including Testing For Leakages Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. (The Wash Hand Basin And Specials Should Be Got Approved By The Executive Engineer Before Use On Works).-Colour Glazed Wash Hand Basin A) Without Pedestal , Supplying And Fixing In Position Indian Make Bevelled Edge Mirror Of Approved Quality And Brand Pvc / Fibre Glass Framed 600 X 450 X 5.5Mm Thick Mirror, Shelf Type With Hard Board Backing Of Approved Colour Fixed With Brass Screws, Rawl Plug, Etc., Complete Complying With Standard Specification , Supplying And Fixing Best Approved Best Quality Brass Cp Soap Tray Of Size 150 X 100Mm Including Cost Of Teak Wood Plugs, Brass Screws, Etc., Complete Complying With Standard Specifications. , Supplying And Fixing Approved Best Quality Brass Cp Towel Rail 600Mm Long And 20Mm Dia With Brackets Of Same Materials Including Cost Of Teak Wood Plugs And Cp Screws, Etc., Complete Complying With Standard Specifications. , Supplying And Fixing In Position 15Mm Dia Brass Cp Screw Down Tap (Heavy Duty) Of Approved Make Conforming To Bis Specifications And Quality Including Cost Of Shellac, Thread, Etc., Complete Complying With Standard Specification And Including Cutting And Threading Wherever Necessary , Supplying And Fixing In Position Best Quality Pvc Soil / Waste Pipes Of Various Dia Having 6 Kg / Sq.Cm. Pressure Bis Mark And Providing Leak Proof Joints Using Pvc Adhesives Including Fixing To The Wall With Special Pvc / Ms Clamp, Teak Wood Plugs, Brass Screws, Etc., And Making Connection To All Sanitary Fittings, Dismantling Masonry / Reinforced Cement Concrete Works Wherever Found Necessary And Making The Good Dismantled Portion To The Original Condition, Including Testing For Any Leakages, Etc., Complete Complying With Standard Specifications. (The Pvc Pipes Should Be Got Approved By The Executive Engineer Before Use On Works). The Rate For Earth Work Excavation Will Be Measured And Paid Separately In The Cases Where The Pipe Lines Are Proposed To Laid Below Ground Level , 75Mm Dia Pvc Soil / Waste Pipe , 110Mm Dia Pvc Soil / Waste Pipe , Supplying And Fixing In Position Pvc Specials Of The Following Dia And Types Of Approved Quality Confirming To Bis And Providing Leak Proof Joints Including Fixing To The Walls And Giving Connection To The Pvc Soil Stacks, Dismantling The Masonry Or Reinforced Cement Concrete Works And Re-Doing The Dismantled Portion To Original Condition Etc., Complete Complying With Standard Specifications. , 75Mm Dia Pvc Elbow , 75Mm Dia Pvc Tee , 75Mm Dia Pvc Tee With Single Door , 75Mm Dia Pvc Bend , 110Mm Dia Pvc Elbow , 110Mm Dia Pvc Tee , 110Mm Dia Pvc Tee With Single Door , 110Mm Dia Pvc Bend , Supplying And Fixing Position Pvc Nahani Trap / Floor Trap Of The 100 X 75Mm With Pvc Gratings Sizes With Best Stainless Steel Gratings Of Approved Brand And Quality, Fixed Over A Bed Of Brick Jelly Lime Concrete 1:2:5 (One Part Of Lime, Two Part Of Sand And Five Part Of 40Mm Gauge Brick Jelly) And Finished With Cement Mortar 1:3 (One Cement, Three Sand) Including Dismantling Masonry Works Wherever Found Necessary And Making Good The Dismantled Portions To The Original Condition And Giving Connection To The Pvc Pipes, Etc., Complete Complying With Standard Specification. , Supplying And Fixing Pvc Ventilating Shaft Of 110Mm Dia (Having Working Pressure 4 Kg. / Sq.Cm) With 3 Metre Height Including Cost Of Pvc Cylindrical Cowl Of Best Approved Quality Etc., Complete Complying With Standard Specifications And As Directed By The Departmental Officers , Supplying And Fixing In Position Ci Manhole Covers With Ci Frames (Heavy Duty) Of Size 60Cm X 60Cm Of Best Approved Quality As Per Standard Specification Etc., Complete Compying With Standard Specifications , Supplying And Filling 20Mm Guauge Hbgs Stone Jelly For Dispersion Trench Including Loading Conveying And Unloading And As Directed By The Departmental Officers Etc. Complete Complying With Standard Specification. , Supplying And Filling 40Mm Guauge Hbgs Stone Jelly For Dispersion Trench Including Loading Conveying And Unloading And As Directed By The Departmental Officers Etc. Complete Complying With Standard Specification. , Drilling 150Mm Dia Vertical Bore Using Power Drill In Hard Rock To Any Required Depth As Directed By The Departmental Officers Including Labour Charges For Inserting Casing Pipes To The Require Depth Assembly In Drilled Hole Including Welding The Joint If Necessary, Grouting The Casing Pipe Etc., And Including Transportation Charges For The Rig And Support Vehicle. , Up To 150M Below Ground Level , From 151M Up To 180M , From 181M Up To 210M , From 211M Up To 240M , Supplying And Fixing Of Pvc Casing Pipe 160Mm Dia Suitable For 6 Borewell Conforming To I.S. 12818 - 1992 With Screwed And Socked And Centering Guides For Every 15M Interval Etc., As Directed By The Departmental Officers. [With / Without Slot] , Supply Suitable Pvc End Cap (6Kg/Sqcm) Of Best For Casing Pipe Of 6 Dia Borewell Quality With Isi Mark, The Pvc Should Got Approved By The Departmental Officers. , Supply And Run Off Water Proof 3 Core 4 Sq.Mm Flat Pvc Insulated Copper Cable For Submersible Pumpset In The Borewell Including Fixing And Tying With Copper Wire And Clamping Water Pipe Etc., Complete As Directed By The Departmental Officers. , Supplying And Fixing 40 Mm Dia Upvc Pipe Of Best Quality For Delivery Cum Support Pipe For Submersible Motor Inside Borewell Etc., Complete As Directed By The Departmental Officers. A) 40 Mm Dia Pipe , Supplying And Fixing Of Nylon Rope For Submersible Motor Of Approved Quality In Etc,Complete Complying With Standard Specifications. , Supplying And Erecting Isi Make Submersible Pump Of 7.5 Hp/ 5.0 Kw Model Csm-9 With Outer Dia 50Mm Of Is 14220 Specification With Submersible S/D Starter Of 8.9 - 13.50 A Rekat Range With 13.5 A Rating And 380-415 V Ac Coil Voltage As Per Specification. Providing Necessary Panel Board With Dol Bush Button Starter With Over Load Relay Three Phase Preventer Indicating Lamps On/Off Switches-1 No Automanual Selection Switch Complete As Directed Etc, Complete. Including Panel Board. , Supplying And Fixing Wall Mounting Of Panel Board With Following Accessories A.Suitable Dol Type Push Botton Automatic Starter Etc., Complete. , Supplying And Erecting 2H.P Monoblock With Isi Mark With Necessary Accessories (Motor Should Be Got Approved By Executive Engineer Before Use Onworks) Complete Complying With Standard Specification. , Supplying And Fixing Of Pvc Readymade Water Tank (1000Lit) Of Best And Approved Quality With Isi Specification Labour For Fixing Etc., Complete.Should Be Got Approved By The Executive Engineer Before Use On Works , Providing Anti-Termite Treatment To Soil Adjecent And Under Building Foundation, Plinth Periphery Of The Building By Application Of Chemicals Of Is 63613 Part I To Iv In Stages To Suit The Progress Of Work Consist As Per The Detailed Specification As Below. Including Breaking Of Termite Mounds, Making Holes With Crow Bar, Closing The Holes After The Treatment And Including Cost Of Chemicals, Labour Charges, Transport And Storing Etc., Complete And As Directed By The Departmental Officers. , Gst
|