|
Tender For 2.6.1Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Upto 50M And Lift Upto 1.5M, Disposed Earth To Be Levelled And Neatly Dressed. All Kind Of Soil. , 15.6Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved. , 2.28.1Surface Dressing Of The Ground Including Removing Vegetation And Inequalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Up To 50 M And Lift Up To 1.5 M. , 2.8.1Earth Work In Excavation By Mechanical Means By Hydraulicexcavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or10 Sqm On Plan Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , 2.13.1.2Earth Work In Excavation By Mechanical Means By Hydraulicexcavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or10 Sqm On Plan Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , 2.25Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth,Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5M. , 4.1.8Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). All Works Upto Plinth Level. , 7.1.1Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level With :Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , 7.2.1Random Rubble Masonry With Hard Stone In Superstructure Above Plinth Level And Upto Floor Five Level, Including Leveling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size) At Window Sills, Ceiling Level And The Like.Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , 4.4.1Providing And Laying Cement Concrete In Kerbs, Steps And The Like At Or Near Ground Level Excluding The Cost Of Centering, Shuttering And Finishing.1:1½:3 (1 Cement: 1½ Coarse Sand(Zone-Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size) , 16.68Providing And Laying 60Mm Thick Faciory Made Cement Concrete Interlocking Paver Block Of M -30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Line Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. , 16.1Making Bajri Path Including Preparation Of Subgrade, Supplying And Laying Brick Aggregate Of 50 Mm Nominal Size 7.5 Cm Deep With Blinding Material Consisting Of 12 Mm Moorum And 12 Mm Red Bajri Consolidated With Road Roller. , 16.69Providing And Laying At Or Near Ground Level Factory Made Kerb Stone Of M-25 Grade Cement Concrete In Position To The Required Line, Level And Curvature, Jointed With Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Including Making Joints With Or Without Grooves (Thickness Of Joints Except At Sharp Curve Shall Not To More Than 5Mm), Including Making Drainage Opening Wherever Required Complete Etc. As Per Direction Of Engineer-In-Charge (Length Of Finished Kerb Edging Shall Be Measured For Payment). (Precast Cement Concrete Kerb Stone Shall Be Approved By Engineer-In-Charge). , 5.1.2Providing And Laying In Position Specified Grade Of Reinforceed Cement Cocrete Excluding The Cost Of Centering, Shuttring, Finishing And Reinforcment - All Work Upto Plinth Level.1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20Mm Nominal Size) , 5.2.2Reinforced Cement Concrete Work In Walls (Any Thickness),Including Attached Pilasters, Buttresses, Plinth And String Courses,Fillets, Columns, Pillars, Piers,Abutments, Posts Concrete Work In Walls (Any Thickness),Including Attached Pilasters, Buttresses, Plinth And String Courses,Fillets, Columns, Pillars, Piers,Abutments, Posts And Struts Etc. Upto Floor Five Level Excluding Cost Of Centring,Shuttering, Finishing And Reinforcement.1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20Mm Nominal Size) , 5.3Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size). , 5.9.1Centering And Shuttering Including Strutting, Propping Etc. And Removal Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , 5.9.3Centering And Shuttering Including Strutting, Propping Etc. And Removal Suspended Floors, Roofs, Landings, Balconies And Access Platform , 5.9.6Centering And Shuttering Including Strutting, Propping Etc. And Removal Columns, Pillars, Piers, Abutments, Posts And Struts , 5.9.5Centering And Shuttering Including Strutting, Propping Etc. And Removal Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , 5.9.7Centering And Shuttering Including Strutting, Propping Etc. And Removal Stairs, (Excluding Landings) Except Spiral-Staircases , 5.22.1Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. , 10.25.2Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works , 10.2Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , 6.1.1Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , 6.4.2Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In :Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , 6.13.2Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. , 9.147A1.1Providing And Fixing Factory Made Upvc Glazed/Wire Mesh Windows/ Doors Comprising Of Lead Free Upvc Multi-Chambered Frame, Sash And Mullion/Coupler (Where Ever Required) Extruded Profiles Having Minimum Wall Thickness Of 1.70 Mm For Series R1 And R2 Profiles And 2.10 Mm For Series R3 And R4 Profiles Conforming To En: 12608 In Any Shape, Colour And Design Duly Reinforced With Galvanized Mild Steel Section Made Of Required Shape & Size As Per Cpwd Specification, Upvc Extruded Glazing Beads, Interlocks And Inline Sash Adaptor (Where Ever Required) Of Appropriate Dimension, Epdm Gasket, Hardware, Ss 304 Grade Fasteners Of Minimum 8 Mm Dia With Countersunk Head, Comprising Of Matching Polyamide Pa6 Grade Sleeve For Fixing Frame To Finished Wall As Per Is 1367 : Part 1 To 14, Plastic Packers, Plastic Caps And Necessary Stainless Steel Screws Etc. Profile Of Frame, Sash & Mullion (If Required) Shall Be Mitred Cut And Fusion Welded/Mechanically Jointed Duly Sealed At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealant Over Backer Rod Of Approved Size And Quality, All Complete As Per Approved Drawing Conforming To Cpwd Specification & Direction Of Engineer-In-Charge. Section Of Steel Reinforcement And Cross Sections Of Upvc Profiles To Be As Per Design Approved By Engineer-In-Chargetwo Track Two Panels Sliding Window With Aluminium Channel For Roller Track, Wool Pile, Nylon Rollers With Ss 304 Body. Using R2 Series With Frame (40 Mm & Above) X (40 Mm & Above) & Sash (25 Mm & Above) X (50 Mm & Above) With Zinc Alloy (Zamak) Powder Coated Touch Locks With Hook (Height Upto 1.2 Metre). , 9.147.C1.2Providing And Fixing Factory Made Upvc Glazed/Wire Mesh Windows/ Doors Comprising Of Lead Free Upvc Multi-Chambered Frame, Sash And Mullion/Coupler (Where Ever Required) Extruded Profiles Having Minimum Wall Thickness Of 1.70 Mm For Series R1 And R2 Profiles And 2.10 Mm For Series R3 And R4 Profiles Conforming To En: 12608 In Any Shape, Colour And Design Duly Reinforced With Galvanized Mild Steel Section Made Of Required Shape & Size As Per Cpwd Specification, Upvc Extruded Glazing Beads, Interlocks And Inline Sash Adaptor (Where Ever Required) Of Appropriate Dimension, Epdm Gasket, Hardware, Ss 304 Grade Fasteners Of Minimum 8 Mm Dia With Countersunk Head, Comprising Of Matching Polyamide Pa6 Grade Sleeve For Fixing Frame To Finished Wall As Per Is 1367 : Part 1 To 14, Plastic Packers, Plastic Caps And Necessary Stainless Steel Screws Etc. Profile Of Frame, Sash & Mullion (If Required) Shall Be Mitred Cut And Fusion Welded/Mechanically Jointed Duly Sealed At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealant Over Backer Rod Of Approved Size And Quality, All Complete As Per Approved Drawing Conforming To Cpwd Specification & Direction Of Engineer-In-Charge. Section Of Steel Reinforcement And Cross Sections Of Upvc Profiles To Be As Per Design Approved By Engineer-In-Chargetwo Track Two Panels Sliding Window With Aluminium Channel For Roller Track, Wool Pile, Nylon Rollers With Ss 304 Body. Using R2 Series With Frame (40 Mm & Above) X (40 Mm & Above) & Sash (25 Mm & Above) X (50 Mm & Above) With Zinc Alloy (Zamak) Powder Coated Touch Locks With Hook (Height Upto 1.2 Metre). , 147.F1.1Casement Door Single Panel With Zinc Alloy (Zamak) 3D Hinges, Multi-Point Locking System With Cylinder, Zinc Alloy (Zamak) Powder Coated Handles On Both Sides.Using R3 Series With Frame (55 Mm & Above) X (50 Mm & Above) & Sash (55 Mm & Above) X (85 Mm & Above) (Height Upto 2.5 Metre).) , 11.27Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. , 11.41.4Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3Kg/Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 1000X1000 Mm , 11.46.4Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3Kg/Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 1000X1000 Mm , 8.31Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 8.2.2.2Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. , 13.4.212 Mm Cement Plaster Of Mix :1:6 (1 Cement: 6 Coarse Sand) , 13.6.120 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Coarse Sand) , 13.41.1Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade :New Work (Two Or More Coats) Over And Including Water Tinnable Priming Coat With Cement Primer , 13.45.1Finishing Walls With Textured Exterior Paint Of Required Shade : New Work (Two Or More Coats Applied @ 3.28 Ltr/10 Sqm) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20Kg/10 Sqm , 13.26Providing & Applying White Cement Based Putty Of 2 Mm Thick Of Approved Brand Over Plastered Wall Surface For Even & Smooth Wall Fiinsh Applying Primer Coat , 13.50.3Applying Primer Coat With Ready Mix Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacturer On Steel Works And Gi , 13.52.1Finishing With Epoxy Paint Two Coats On All Location Prepared And Applied , 12.1.1Providing Corrugated G.S. Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces), Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required.1.00 Mm Thick With Zinc Coating Not Less Than 275 Gm/M² , 12.51.1Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete:Ridges Plain (500 - 600Mm) , 12.51.4Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete:Brage Board (Upto 300Mm) , 12.51.6Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete:Gutter (600 Mm Over All Girth) , 12.41.2Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, (I) Single Socketed Pipes.110 Mm Diameter , 12.45.1Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms/Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10X0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15X0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And12.5 Mm Thick Tapered Edge Gypsum Plain Board Conforming To Is: 2095- (Part I) : 2011 (Board With Bis Certification Marks) Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With
|