Bids Are Invited For Acquisition Of A Digital X-Ray Device For General Radiology Of Adult And Pediatric Pati ... in Brazil
Tender Notice
TenderID
110068236
Tender Brief
Bids Are Invited For Acquisition Of A Digital X-Ray Device For General Radiology Of Adult And Pediatric Patients, In Accordance With The Specifications Contained In The Attached Terms Of Reference, To Be Used In The Municipal Medical Specialties Outpatient Clinic (Amme) Of Jaboticabal To Care For Specialized Care Patients.
Digital X-Ray Device For General Radiology Minimum Composition And Required Technical Characteristics X-Ray Generator (High Frequency) • Microprocessed, High Frequency Type. • Voltage (Kv): 40 To 150 Kv, In Steps Of 1 Kv. • Current (Ma): 10 To 630 Ma In 32 Steps Or More. • Time: From 0.001 S To 5 S In 48 Steps Or More. • Mas Adjustment Range: 0.5 To 500 Mas Or Greater. • Nominal Output Power: 55 Kw (100Kv @ 550Ma) Or Higher. • Anatomical Programmer With 380 Protocols Or More, Configurable By The User. • Built-In Generator Under The Exam Table. • Overload Protection Device And Automatic Network Compensation. • Control Panel With Visualization Of Errors, Kv, Ma, Time And Radiation Dose. • Pair Of High-Voltage Cables. • Electrical Supply: Three-Phase 380V, 50/60Hz. Exam Table (Fixed With Floating Top) • Minimum Width: 80 Cm. • Minimum Length: 230 Cm. • Transverse Displacement: Minimum ±12 Cm (24 Cm). • Longitudinal Displacement: Minimum ±50 Cm (100 Cm). • Electromagnetic Brakes With Pedal Release. • Oscillating Anti-Diffusion Grid: I. Minimum Ratio: 10:1 Ii. Density: 40 Lines Per Cm Iii. Focal Distance: 100 Cm • Removable Grid For Pediatric Examinations, As Per In No. 90/2021. • Supports Patients Weighing Up To 315Kg Or More. Tube Holder Stand • 180º Rotation Of The Spine Or Arm, Allowing Examinations On A Stretcher Next To The Table. • Tube/Collimator Assembly Rotation: ±120 For Bucky Mural Examinations. • Telescopic Arm Displacement: 20 Cm. • Longitudinal Displacement Of The Stand: Minimum 180Cm. Bucky Mural • Anti-Diffusion Grid With: I. Minimum Ratio: 10:1. Ii. Density: 40 Lines Per Cm Or More. Iii. Focal Distance: 100 To 180 Cm Or Greater. • Removable Grid For Pediatric Exams, According To In No. 90/2021. • Support For 35X43 Cm Detector In Portrait And Landscape Positions, With Centralization
Contact Information
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 110068236
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.