|
Reagent For Transportation And Storage Of Clinical Material, With Mucolytic, Packaged In 0.5 Ml. For Transportation And Storage Of Scraping Material From The Urogenital Tract, Oropharynx, Rectum, Conjunctiva Of The Eyes, As Well As Erosive And Ulcerative Elements Of Human Mucous Membranes And Skin Ability To Transport/Storage Clinical Material From Men And Women Possibility Of Transporting/Storing Clinical Material At Room Temperature (From +18 To +25 °C) For Up To 28 Days, At A Temperature From + 2 To +8 °C For Up To 3 Months The Transport Medium Must Contain A Pink Buffered Saline Solution, A Mucolytic, A Preservative And A Stabilizer The Transport Medium Should Prevent Premature Lysis Of Cells In The Smear The Transport Environment Must Prevent The Growth Of Foreign Microflora The Transport Medium Must Have The Ability To Dissolve Mucus The Number Of Test Tubes Is At Least 100 Pcs. 0.5 Ml Each. Gost R 51088-97, A Set Of Reagents For Detecting The Dna Of Fungi That Cause Mycoses. For Pcr Amplification Of Fungal Dna With Hybridization-Fluorescence Detection Of Amplification Products In Real Time Possibility Of Qualitative Dna Determination Of Trichophyton Rubrum, Trichophyton Mentagrophytes Complex, Trichophyton Tonsurans, Epidermophyton Floccosum, Microsporum Canis All Components Of The Kit Are Ready For Use And Do Not Require Restoration Availability Of Reagents For Dna Extraction Availability Of Solution For Pre-Treatment Of Material Availability Of Lysis Solution Availability Of Solution For Washing And Elution Presence Of Magnetized Silica The Pcr Mixture Is Not Divided Into Test Tubes Availability Of Internal Control Sample (Icc), Negative Isolation Control Sample (Icc) And Negative Pcr Control Sample (K-) Presence Of At Least Two Positive Control Samples (Pcs) The Expiration Date Of The Reagents After Opening Must Be Equal To The Declared Expiration Date Of The Reagent Kit Availability Of A Protection System Against Contamination By Amplicons Possibility Of Simultaneous Analysis Of Different Infections By Using One Amplification Program For Kits From The Same Manufacturer Possibility Of Use In Conjunction With Automatic Stations For The Isolation Of Nucleic Acids And Stations For The Preparation And Dosing Of Reaction Mixtures Number Of Tests At Least 100 The Kits Are Stored At 2 - 8 °C And Do Not Require Freezing. Gost R 51088-97, Reagent Kit For Dna Detection Of Leishmania Spp. In Biological Material By Pcr With Hybridization-Fluorescent Detection. Possibility Of Pcr Amplification Of Dna Of Leishmania Spp. Possibility Of Hybridization-Fluorescence Detection By “End Point” And In “Real Time”. Pcr Mixture-1-Fep/Frt Should Not Be Poured Into Test Tubes. Presence Of Taqf Polymerase For Organizing A Hot Start Availability Of Pcr Mixture-2, Dna Buffer, Mineral Oil Availability Of Pko Dna Leishmania / Sti, Control Extraction Samples: Oko, Vko. Gost R 51088-97, A Set Of Reagents For The Amplification Of Trichomonas Vaginalis Dna Using The Polymerase Chain Reaction Method With Hybridization-Fluorescent Detection In Real Time. For Pcr Amplification Of Trichomonas Vaginalis Dna With Hybridization-Fluorescent Detection Of Amplification Products In Real Time Possibility Of Quantitative Determination Of Trichomonas Vaginalis Dna All Components Of The Kit Are Ready For Use And Do Not Require Restoration The Pcr Mixture Should Be Placed Under Paraffin Into 0.2 Ml Tubes To Ensure A “Hot Start” Availability Of A Ready-Made Pcr Buffer That Does Not Require Mixing Additional Components Presence Of A Negative Control Sample For Isolation (Ncs) And A Negative Control Sample For Pcr (K-) Availability Of A Set Of Dna Calibrators Availability Of A Protection System Against Contamination By Amplicons Adapted To Work Using The Frt Manager Automatic Results Analysis Program Available To The Customer The Number Of Tests Is At Least 100. Gost R 51088-97, A Set Of Reagents For Detecting The Dna Of Microorganisms Of The Genus Ureaplasma (Ureaplasma Spp.) In Clinical Material Using The Polymerase Chain Reaction (Pcr) Method With Hybridization-Fluorescence Detection In Real Time. For Pcr Amplification Of Dna Of Microorganisms Of The Genus Ureaplasma (U.Parvum And U.Urealyticum In Total) With Hybridization-Fluorescent Detection Of Amplification Products In “Real Time” All Components Of The Kit Are Ready For Use And Do Not Require Restoration Pcr Mixture-1 Should Be Dripped Under Wax Into 0.2 Ml Test Tubes To Ensure A “Hot Start” Availability Of A Ready-Made Pcr Mixture-2, Which Does Not Require Mixing Additional Components Availability Of A Complex Positive Control Sample (Cpo) Of Dna Of Microorganisms Of The Genus Ureaplasma (U.Parvum And U.Urealyticum), Dna Buffer Ready-Made Pcr Mixtures Must Have A Shelf Life Equal To The Shelf Life Of The Test System The Number Of Tests Is At Least 110. Gost R 51088-97, A Set Of Reagents For Amplification Of Toxoplasma Gondii Dna Using The Polymerase Chain Reaction Method With Hybridization-Fluorescence Detection In Real Time. To Carry Out Pcr Amplification Of Toxoplasma Gondii Dna With Hybridization-Fluorescence Detection In Real Time Pcr Mixture-1 Should Not Be Divided Into Test Tubes Sensitivity Not Lower Than 400 Copies/Ml Presence Of Pko Dna Toxoplasma Gondii, Vko, Oko Availability Of Pcr Buffer-Frt And Dna Buffer Presence Of Taqf Polymerase The Number Of Tests Is At Least 60. Gost R 51088-97, A Set Of Reagents For Amplification Of Neisseria Gonorrhoeae Dna Using The Polymerase Chain Reaction (Pcr) Method With Hybridization-Fluorescent Detection In Real Time. For Pcr Amplification Of Neisseria Gonorrhoeae Dna With Hybridization-Fluorescent Detection Of Amplification Products In Real Time Possibility Of Quantitative Determination Of Neisseria Gonorrhoeae Dna All Components Of The Kit Are Ready For Use And Do Not Require Restoration The Pcr Mixture Should Be Placed Under Paraffin Into 0.2 Ml Tubes To Ensure A “Hot Start” Availability Of A Ready-Made Pcr Buffer That Does Not Require Mixing Additional Components Presence Of A Negative Control Sample For Isolation (Ncs) And A Negative Control Sample For Pcr (K-) Availability Of A Set Of Dna Calibrators Availability Of A Protection System Against Contamination By Amplicons Adapted To Work Using The Frt Manager Automatic Results Analysis Program Available To The Customer Number Of Tests At Least 100 All Components Of The Kit Must Be Stored Under The Same Temperature Conditions Without Freezing Gost R 51088-97, Set Of Reagents For Dna Extraction From Biological Material (Magno Prime Fast). Possibility Of Dna Extraction From Clinical Material (Scraping Material And Discharge Of The Mucous Membranes Of The Urogenital Tract, Vagina, Cervical Canal, Urethra, Oropharynx, Rectum, Conjunctiva, Vesicular Rashes And Erosive And Ulcerative Lesions Of The Skin And Mucous Membranes, Urine, Prostate Secretions) Using Magnetized Silica Possibility Of Dna Extraction Both Using A Magnetic Stand And Using The Centrifugation Method Without Using A Magnetic Stand Can Be Used With Automatic Nucleic Acid Extraction Stations Possibility Of Using An Internal Control Sample At The Stage Of Nucleic Acid Isolation Presence Of Magnetized Silica Availability Of Lysis Solution, Solution For Washing And Elution Of Dna Availability Of Internal Control Sample Must Be Designed For A Number Of Samples Of At Least 96. Gost R 51088-97, A Set Of Reagents For Amplification Of Chlamydia Trachomatis Dna Using The Polymerase Chain Reaction Method With Hybridization-Fluorescence Detection In Real Time. For Pcr Amplification Of Chlamydia Trachomatis Dna With Hybridization-Fluorescent Detection Of Amplification Products In Real Time Possibility Of Quantitative Determination Of Chlamydia Trachomatis Dna All Components Of The Kit Are Ready For Use And Do Not Require Restoration The Pcr Mixture Should Be Placed Under Paraffin Into 0.2 Ml Tubes To Ensure A “Hot Start” Availability Of A Ready-Made Pcr Buffer That Does Not Require Mixing Additional Components Presence Of A Negative Control Sample For Isolation (Ncs) And A Negative Control Sample For Pcr (K-) Availability Of A Set Of Dna Calibrators Availability Of A Protection System Against Contamination By Amplicons Adapted To Work Using The Frt Manager Automatic Results Analysis Program Available To The Customer Number Of Tests At Least 100 All Components Of The Kit Must Be Stored At The Same Temperature Conditions Without Freezing. Gost R 51088-97, A Set Of Reagents For The Amplification Of Mycoplasma Hominis Dna Using The Polymerase Chain Reaction Method With Hybridization-Fluorescence Detection In Real Time. For Pcr Amplification Of Mycoplasma Hominis Dna With Hybridization-Fluorescent Detection Of Amplification Products In Real Time All Components Of The Kit Are Ready For Use And Do Not Require Restoration The Pcr Mixture Should Not Be Poured Into Test Tubes Availability Of A Ready-Made Pcr Buffer That Does Not Require Mixing Additional Components Presence Of A Positive Control Sample (Pcs), A Negative Isolation Control Sample (Nks) And A Negative Pcr Control Sample (K-) Availability Of A Protection System Against Contamination By Amplicons Number Of Tests At Least 100 All Components Of The Kit Must Be Stored At The Same Temperature Conditions Without Freezing. Gost R 51088-97, A Set Of Reagents For The Qualitative And Quantitative Determination Of Dna Of Herpes Simplex Virus (Hsv) And Cytomegalovirus (Cmv) Using The Polymerase Chain Reaction (Pcr) Method With Hybridization-Fluorescent Detection In Real Time. For Qualitative And Quantitative Dna Determination Of Herpes Simplex Virus (Hsv) And Cytomegalovirus (Cmv) Possibility Of Hybridization-Fluorescence Detection Of Amplification Products In Real Time The Pcr Mixture Should Be Poured Under The Wax Into Separate 0.2 Ml Tubes To Ensure A “Hot Start” Availability Of Pcr Buffer, Negative Control Availability Of At Least Two Dna Calibrators The Number Of Tests Is At Least 110. Gost R 51088-97, A Set Of Reagents For Simultaneous Dna Amplification Of N. Gonorrhoeae / C. Trachomatis / M. Genitalium / T. Vaginalis With Hybridization-Fluorescent Detection In Real Time. For Simultaneous Dna Amplification Of Neisseria Gonorrhoeae, Chlamydia Trachomatis, Mycoplasma Genitalium And Trichomonas Vaginalis Possibility Of Hybridization-Fluorescence Detection Of Amplification Products In Real Time Availability Of Control Samples The Number Of Tests Is At Least 110. Gost R 51088-97
|