|
Long Burning Boiler. Basic Technical Requirements Parameter Required Value Type Of Fuel Solid Fuel (Coal, Firewood) Nominal Heating Capacity, Not Less Than 30 Kw Heated Area, Not Less Than 300 M² Efficiency, %, Not Less Than 84 Maximum Operating Pressure, Bar Not Less Than 1.0 Maximum Outlet Water Temperature, °C Not Less Than 95 Single Fuel Load, L 188 Metal Thickness Not Less Than 5 Mm. Boiler Weight: Not Less Than 482 Kg. Dimensions (H×W×D), No More Than 1700 × 640× 1060 Mm The Diameter Of The Connection To The Heating Network Is At Least 32 Mm. Chimney Diameter, No More Than 159 Mm 2. Delivery Set - Water Heating Boiler, At Least - 1 Pc. - Controller (Control Panel) At Least - 1 Pc. - Boost Fan At Least - 1 Pc. - Thermal Manometer At Least - 1 Pc. - Safety Valve - 1 Piece - Product Passport - Operating Instructions In Kazakh And Russian Languages - Factory Test Report - Warranty Card (At Least 12 Months). Gost 20548-93. Delivery And Installation In Emeltau Village, Long Burning Boiler. Parameter Required Value Type Of Fuel Solid Fuel (Coal, Firewood) Nominal Heating Capacity, Not Less Than 60 Kw Heated Area, Not Less Than 600 M² Efficiency, %, Not Less Than 84 Maximum Operating Pressure, Bar Not Less Than 1.0 Maximum Outlet Water Temperature, °C Not Less Than 95 One-Time Fuel Load, Not Less Than 340 L Metal Thickness, Mm Not Less Than 5 Boiler Weight, Not Less Than 750 Kg Dimensions (H×W×D), No More Than 2050 × 760× 1220 Mm Diameter Of Connection To The Heating Network, Not Less Than 40 Mm Chimney Diameter, Mm No More Than 219 2. Delivery Set - Water Heating Boiler - 1 Piece - Controller (Control Panel) - At Least 1 Piece - Boost Fan - At Least 1 Pc. - Thermal Manometer - At Least 1 Pc. - Safety Valve - At Least 1 Piece - Product Passport - Operating Instructions In Kazakh And Russian Languages - Factory Test Report - Warranty Card (At Least 12 Months) -Manufactured In Accordance With The Requirements Of Gost And Tr Ts. Gost 20548-93. Delivery And Installation Of A Long-Burning Boiler In Saryarka, Long Burning Boiler. Basic Technical Requirements Parameter Required Value Type Of Fuel Solid Fuel (Coal, Firewood) Nominal Heating Output, Not Less Than 15 Kw Heated Area, Not Less Than 150 M². Efficiency, %, Not Less Than 84 Maximum Operating Pressure, Bar Not Less Than 1.0 Maximum Outlet Water Temperature, °C Not Less Than 95 One-Time Fuel Load, No Less Than 122 Liters. Metal Thickness, Not Less Than 5 Mm Boiler Weight, Not Less Than 400 Kg Dimensions (H×W×D), No More Than 1350 × 565× 920 Mm The Diameter Of The Connection To The Heating Network Is At Least 32 Mm Chimney Diameter, No More Than 159 Mm 2. Delivery Set - Water Heating Boiler - 1 Piece - Controller (Control Panel) At Least - 1 Pc. - Boost Fan At Least - 1 Pc. - Thermal Manometer At Least - 1 Pc. - Safety Valve At Least - 1 Pc. - Product Passport - Operating Instructions In Kazakh And Russian Languages - Factory Test Report - Warranty Card (At Least 12 Months). Delivery And Installation Of A Long-Burning Boiler In The Village Of Maltugel, Long Burning Boiler. Basic Technical Requirements Parameter Required Value Type Of Fuel Solid Fuel (Coal, Firewood) Nominal Heating Capacity, Not Less Than 30 Kw Heated Area, Not Less Than 300 M² Efficiency, %, Not Less Than 84 Maximum Operating Pressure, Bar Not Less Than 1.0 Maximum Outlet Water Temperature, °C Not Less Than 95 Single Fuel Load, L 188 Metal Thickness Not Less Than 5 Mm. Boiler Weight: Not Less Than 482 Kg. Dimensions (H×W×D), No More Than 1700 × 640× 1060 Mm The Diameter Of The Connection To The Heating Network Is At Least 32 Mm. Chimney Diameter, No More Than 159 Mm 2. Delivery Set - Water Heating Boiler, At Least - 1 Pc. - Controller (Control Panel) At Least - 1 Pc. - Boost Fan At Least - 1 Pc. - Thermal Manometer At Least - 1 Pc. - Safety Valve - 1 Piece - Product Passport - Operating Instructions In Kazakh And Russian Languages - Factory Test Report - Warranty Card (At Least 12 Months). Gost 20548-93. Delivery And Installation In Baykoshkar Village, Long Burning Boiler. Basic Technical Requirements Parameter Required Value Type Of Fuel Solid Fuel (Coal, Firewood) Nominal Heating Capacity, Not Less Than 30 Kw Heated Area, Not Less Than 300 M² Efficiency, %, Not Less Than 84 Maximum Operating Pressure, Bar Not Less Than 1.0 Maximum Outlet Water Temperature, °C Not Less Than 95 Single Fuel Load, L 188 Metal Thickness Not Less Than 5 Mm. Boiler Weight: Not Less Than 482 Kg. Dimensions (H×W×D), No More Than 1700 × 640× 1060 Mm The Diameter Of The Connection To The Heating Network Is At Least 32 Mm. Chimney Diameter, No More Than 159 Mm 2. Delivery Set - Water Heating Boiler, At Least - 1 Pc. - Controller (Control Panel) At Least - 1 Pc. - Boost Fan At Least - 1 Pc. - Thermal Manometer At Least - 1 Pc. - Safety Valve - 1 Piece - Product Passport - Operating Instructions In Kazakh And Russian Languages - Factory Test Report - Warranty Card (At Least 12 Months). Gost 20548-93. Delivery And Installation In Akshauli Village, Long Burning Boiler. Parameter Required Value Type Of Fuel Solid Fuel (Coal, Firewood) Nominal Heating Capacity, No Less Than 60 Kw Heated Area, No Less Than 600 M² Efficiency, %, No Less Than 84 Maximum Operating Pressure, Bar No Less Than 1.0 Maximum Outlet Water Temperature, °C No Less Than 95 Single Fuel Load, No Less Than 340 L Metal Thickness, Mm No Less Than 5 Boiler Weight, No Less 750 Kg Dimensions (H×W×D), No More Than 2050 × 760× 1220 Mm Diameter Of Connection To The Heating Network, No Less Than 40 Mm Diameter Of The Chimney, Mm No More Than 219 2. Delivery Set - Water Heating Boiler - 1 Pc - Controller (Control Panel) - No Less Than 1 Pc - Pressure Fan - No Less Than 1 Pc - Thermal Manometer - At Least 1 Piece - Safety Valve - At Least 1 Piece - Product Passport - Operating Instructions In Kazakh And Russian Languages - Factory Test Report - Warranty Card (At Least 12 Months) - Manufactured In Accordance With The Requirements Of Gost And Tr Ts. Gost 20548-93. Delivery And Installation Of A Long-Burning Boiler In The Village Of Akshi, Long Burning Boiler. Parameter Required Value Type Of Fuel Solid Fuel (Coal, Firewood) Nominal Heating Capacity, No Less Than 60 Kw Heated Area, No Less Than 600 M² Efficiency, %, No Less Than 84 Maximum Operating Pressure, Bar No Less Than 1.0 Maximum Outlet Water Temperature, °C No Less Than 95 Single Fuel Load, No Less Than 340 L Metal Thickness, Mm No Less Than 5 Boiler Weight, No Less 750 Kg Dimensions (H×W×D), No More Than 2050 × 760× 1220 Mm Diameter Of Connection To The Heating Network, No Less Than 40 Mm Diameter Of The Chimney, Mm No More Than 219 2. Delivery Set - Water Heating Boiler - 1 Pc - Controller (Control Panel) - No Less Than 1 Pc - Pressure Fan - No Less Than 1 Pc - Thermal Manometer - At Least 1 Piece - Safety Valve - At Least 1 Piece - Product Passport - Operating Instructions In Kazakh And Russian Languages - Factory Test Report - Warranty Card (At Least 12 Months) - Manufactured In Accordance With The Requirements Of Gost And Tr Ts.Gost 20548-93. Delivery And Installation Of A Long-Burning Boiler In Mynbulak Village,
|