Tender For Construction Of New 11 Kv And Lt Lines And Running Contract Work For Installation Of 25/63/100/25 ... in India
Tender Notice
TenderID
109811237
Tender Brief
Tender For Construction Of New 11 Kv And Lt Lines And Running Contract Work For Installation Of 25/63/100/250/400 Kva Transformers And Capacity Enhancement Of Transformers And Shifting Of Lines Under The Approved Estimates In The Applications Received On
Tender For Construction Of New 11 Kv And Lt Lines And Running Contract Work For Installation Of 25/63/100/250/400 Kva Transformers And Capacity Enhancement Of Transformers And Shifting Of Lines Under The Approved Estimates In The Applications Received On Poorna Jama Yojna/Jhatpat/Nivesh Mitra Portal In The Working Area Of ??Electricity Distribution Subdivision-Nanauta Under Electricity Distribution Division Rampur Maniharan Saharanpur.- 2 Safe Cartage Of Pcc/ St Poles (Up To13 Mtr.) From Esc, Sre/Je Store To Site Of Work Including Loading & Unloading At Both Ends. 3 Safely Cartage Of Other Complete Line Material 11 Kv Xlpe Cable / Lt Abc Cable (Except Pcc /St Poles) From Esc, Sre/ Je Store To Site Of Work Including Loading, Unloading At Both Ends. 4 Safe Cartage Of 25/63/ 100 Kva T/F From Esc,Sre, To The Site Of Work Including Loading & Unloading At Both Ends. 5 Safe Cartage Of 11 Kv Ct/Pt Unit From Esc,Sre, To The Site Of Work Including Loading & Unloading At Both Ends. 6 Safe Cartage Of 11 Kv Fuse Set/Tpmo Set From Esc,Sre, To The Site Of Work Including Loading & Unloading At Both Ends. 7 Safe Cartage Of 11 Kv Metering Cubical From Esc,Sre, To The Site Of Work Including Loading & Unloading At Both Ends. 8 Safely Carriage Of 11 Kv Outgoing Vcb 300/150/5A From Esc Sre To The Site Of Work Including Loading & Unloading At Both Ends. 9 Safely Carriage Of 250/400 Kva T/F From Esc, Sre To Site Of Work Including Loading & Unloading At Both Ends.. 10 Constriction Of Plinth For Installation Of 250/400 Kva T/F Of Size 1.5X1.5X1.5 Mtr Made Of 9”Inch Thick Wall In All Four Sides With 6”Inch Thick Rcc Top Duly Filled With Sand And Plastered 12Mm Thick In Ratio 1:4 With Cement And Sand On Outer Surface Of Brick Wall. 11 Safely Installation Of New 250/400 Kva T/F On The Plinth By Private Crain With Proper Alignment And Complete Fitting Including Making Ht Connection And Commissioning 12 Providing & Making Of Wiremesh Fencing Size 2.5X2.5X2.5 Mtr With Grouting Making Frame Of Ms Angle 35X35X4 Mm And Fixing Four No Ms Strip Size 25X4 Mm At Equal Distance In Between The Frame And Fixing Square Mesh Of 50 Mm Squre In Each Frame The Fencing Should Cover All Side Of T/F With Providing 1 No Door Size 6X3 With Sitakni & Dandala With Green Paints (British/Asian/Enamel Paints) 13 Earthing Of 250/400 Kva T/F (1 No Body & 1 No. Neutral Earthing) By Boring & Fixing Of G.I Pipe 1½ Dia (Jindal Class B) And Connecting With G.I. Strip Of Size 40X5 Mm And G.I Wire At Bottom Of G.I Pipe To The T/F Providing Of Required Charcoal & Salt In The Pipe. 14 Erection Of Single Support On Pcc/ St Poles (Up To 13 Mtr.) Long With Complete Fitting Of All Accessories Of 11 Kv/Lt Line. Complete. 15 Erection Of Double Pole On Pcc/ St Poles (Up To 13 Mtr.) Long With Complete Fitting With All Accessories Of 11 Kv/Lt Line. Complete. 16 Providing And Fixing Of Stone Ped 300X300X75 17 Providing Of Hdpe Pipe 160 Mm Dia. 18 Driling Of Earth Under Road Crossing 1.5 Mtr. Deep And Laying Of 02 No. Parreral Hdpe Pipe 160 Mm Dia On 0.5 Meter Distance By Drill Machine/Jcb Machine/Labour 19 Laying Of 11/33 Kv Xlpe Cable Size Up To 3X300 Sq Mm In The 02 No. Hdpe Pipe 160 Mm Dia On 0.5 Meter Distance 20 Providing And Fixing Of Number Plate With Clamp On The Each Pole. 21 Providing And Fixing 33 Kv/11 Kv Danger Board With Clamp Nuts & Bolts. For St Poles Made Of 3Mm Thick Foam Sheet (8\ X 6\) With 22 Providing And Fixing Of Gi Barbed Wire On The Each Pole. 23 Providing Of Red Oxide Paints (British/Asian/Enamel Paint) 24 Providing Of Alluminium Paint (British/Asian/Enamel Paint) 25 Painting Of St Poles 11 Mtr, Sp-55 With 2 Coats Of Synthetic Enamel Paint After One Coat Of Ready Mix Primer As Well As Rubbing/Cleaning Of Surface As Required For Proper Completion Of Work. And Remaining By Aluminium Paint Including All Channels/Clamps Etc 26 Laying, Lifting, Stringing, Proper Sagging 11 Kv Ab Cable Of Size 3X95+1X70+/ 3 3X120+1X95 Sq.Mm. Including Fixing Of All Accessories. 27 Fixing Of 11 Kv Stay Rods By Digging Of Pits In Block Of 600X600X300 Mm. & With New Brick And Nozzling Of Stay Wire 7/10 Swg And Fitting The Same On The Pole 28 Concreting Of Stay Rod In Ratio 1:4:8 With Ist Class Brick Ballst With Cement And Sand 29 Earthing Of Poles By Earthing Rod. 30 Providing All Type Ms Clamp For St/Pcc Poles With Nuts Bolts Made Of New Ms Flat 50X5 Mm Best Quality. 31 Providing And Fixing Lt Shekel Insulator Of Size 100X115Mm 32 Providing And Fixing Nuts & Bolts Off Size. 33 Providing And Fixing Dead End Clamp With I-Hook 34 Providing And Fixing Suspention Clamp With I-Hook 35 Providing And Fixing Piercing Connector Diff.Size 36 Providing And Fixing Pg Clamp Diff. Size 37 Providing Of Of 1X16 Sq Mm Cable For Connection Of Distribution Box. 38 Providing Of 11 Kv Cable Terminations Kit Out Door & Indoor Of Size 3X35/3X70/3X120/3X185/3X300 Sq Mm. 39 Providing Of G.I Pipe 100Mm 4\ Dia Class B 40 Laying, Lifting, Stringing, Sagging Jumpring & Binding Of Acsr Weasel Conductor For 11Kv/Lt Line Complete Properly 41 Laying, Lifting, Stringing, Sagging Jumpring & Binding Of Acsr Rabbit Conductor For 11Kv/Lt Line Complete Properly 42 Laying, Lifting, Stringing, Sagging Jumpring & Binding Of Acsr Dog Conductor For 11Kv/Lt Line Complete Properly 43 Removel Of 25/63/100 Kva T/F From The Existing D/P After Opening Ht & Lt Connection And Shifting The T/F From The Site To Esc, Sre. 44 Fixing Of 11 Kv Fuse Set/Tpmo Set Complete Properly. 45 Safe Installation Of 25/63/100 Kva T/F On The Double Pole With Complete Fittings Including Making Connections And Commissioning Properly. 46 Safe Installation Of 11 Kv Ct/Pt Unit On The Double Pole With Complete Fittings Including Making Connections And Commissioning Properly. 47 Safe Installation Of 11 Kv Metering Cubical In The Room With Complete Fittings Including Making Connections And Commissioning Properly. 48 Shifting, Fixing And Installation Of 11 Kv Outgoing Vcb 300/150/5A Properly. 49 Pipe Earthing For 11 Kv Outgoing Vcb 300/150/5A Properly. 50 Chemical Earthing Of Metering Cubical/Ct/Pt Unit And Connecting With G.I Stirp Of Size 35X4 Mm To The Metering Cubical/Ct/Pt Unit Complete Properly.
Contact Information
Contact Person
Superintending Engineer
Address
Electricity Distribution Circle II Saharanpur
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 109811237
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.