Bids Are Invited For Formal Price Registration For The Future And Possible Acquisition Of 02 (Two) X-Rays, 1 ... in Brazil
Tender Notice
TenderID
109782272
Tender Brief
Bids Are Invited For Formal Price Registration For The Future And Possible Acquisition Of 02 (Two) X-Rays, 1 (One) Fixed Digital X-Ray, And 1 (One) Digital Mobile
Equipment With Digital Technology (Flat Panel Detector) Emitting X-Rays For Clinical Diagnostic Imaging Purposes, With Unique Registration With Anvisa. High Frequency Microprocessor Generator. Power From 80 Kw. Three-Phase Power Supply 220/380V At 50/60 Hz, An Autotransformer Must Be Provided If Necessary. Variable Voltage That Minimally Meets The Range From 40 Kv To 150 Kv Or Greater, In Steps Of 1 Kv. Variable Current Between 20 Ma To 1000 Ma Or Greater. Minimum Exposure Time 1Ms To 5S. Selectable Range Of Mas Between 10 To 800 Mas Or Greater. X-Ray Tube, Fine Focus Equal To Or Less Than 0.6 Mm And Coarse Focus Equal To Or Less Than 1.2 Mm; Minimum Rotating Anode 9,700 Rpm; Minimum Anode Thermal Capacity Of At Least 300 Khu. Tube Must Be Branded: Canon (Toshiba), Brand And Model Of Tube Must Be Indicated In The Proposal. Enable The Insertion Of Additional Cu Or Al Filters. System With At Least 800 Factory Pre-Programmed Techniques. Emitter Port Stand With Its Appropriate Characteristics; Column With Longitudinal Displacement From 250 Cm; Vertical Displacement Of At Least 150 Cm; Tube Rotation Around Axis +/-90 Degrees; System With Electromagnetic Brakes, Activated Through Buttons On The Stand’S Front Control; Collimator With Luminous Field Indication With Led Lamp And Automatic Switch Off After 30 Seconds; Distance From The Focal Point Of At Least 100 Cm. Exam Table With Floating Top With Minimum Dimensions Of 200 X 80 Cm, Minimum Longitudinal Displacement Of +/- 40 Cm, With Transverse Displacement +/-12 Cm. Top Centering Indication. Electromagnetic Braking System. Anti-Diffusion Grid Of At Least 10:1 And 103 L/In. Load Capacity Supported By The Table Of At Least 290 Kg. Bucky Mural Minimum Vertical Displacement Of 130 Cm; Rotary Movement Of The Top, With An Inclination Of At Least 90°; With Mechanical Or Electromagnetic Brake System; Focal Distance Between 100 Cm And 180 Cm; Ce Indication, Digital Mobile X-Ray Device With Power Of At Least 40Kw Or Higher; Tube Voltage Range From 40 To 130Kv Or Better In 40 Steps Or More; Current Setting At Least 400 Ma Or Greater; Variation Range From Mas: 0, 1 Mas To 400 Mas Or Greater; Exposure Time 2Ms Or Less; Two-Stage Trigger Cable With A Length Of At Least 2.5 M. Network Cable With A Length Of At Least 2.5 M; Connection Via Simple 3-Pin Socket; Pantographic Or Telescopic Articulated Arm; Sealed Unit/Collimator Assembly Rotation 180 Degrees Or Greater; X-Ray Tube With Rotating Anode Rotating 3,000 Rpm Or Higher; Dual Focus Of Maximum 1.2Mm For Coarse Focus And 0.6Mm For Fine Focus Or Single Focus Of 0.8Mm; Anode Caloric Capacity Of 240Khu Or Greater. Manual Collimator With Adjustable Light Field Indicating Area To Be Irradiated And 30S Electronic Timer; Digital Image Detector 34 X 42 Cm Or Larger; 2500 X 3000 Pixel Acquisition Matrix; Post-Processed Image Depth 16 Bits; Comes With Battery Charger; Monitor Fully Built-In Main Unit With 19-Inch Or Larger Touchscreen; Storage Capacity Of 50,000 Images Or More In Internal Memory (Ssd Or Hd); Software For Digital Radiography With: Brightness And Contrast Adjustment, Image Inversion (Positive/Negative, Above/Below And Right/Left), Image Rotation, Distance And Angle Measurements. Dicom 3.0 Protocols Enabled: Print, Send
Contact Information
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 109782272
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.