Bids Are Invited For A Copper Bus Bar, Size 1 X 18 With Insulated By Pvc Color Markings,Mention The Price With Including The All Works Of Bending ,Drilling, Shaping, Polishing, Bus Bar Color Coding And Etc , A Aluminum Bus Bar, Size 1 X 18 With Insulated By Pvc Color Markings,Mention The Price With Including The All Works Of Bending ,Drilling, Shaping, Polishing, Bus Bar Color Coding And Etc , B Bus Bar Insulator - Sm 35 Red Color, Include With Bolt Nut Vassar And Fixing Charge , C L 250 X W 150 X Thickness 2.5 Mm Hylam Sheet Fabric Base Mechanical Grade. , D The Panel Board Overall Made By 18 Gauge Metal Sheets Only. Overall Outdoor Size Of The Panel 12X12x12 Inches May Be Include The Back Plate And Front Door Sizes For Calculation , E The Bus Bar Insulator And Switches Are Must Be Fixed On The Additional 18 Gauge Ms Back Plate , F This Panel Board Is Placed To Be In Outdoor Atmosphere So Additional Front Door To Be Provided For Safety Precautions. I T Must Be Fulfill The Ip 25 Rating Of Ier Rules. , G The Panel Board Painted With Electrostatic Paint Powder Coating The Shade Of The Color Of The Panel Inside And Outside Shall Be As Per Boq Conforming Is Code No 5. , Trench Excavation Or Digging And Refilling Charges Only , Trench Refilling Charges Only , Cable Laying Charges Only Size Up To 35 Sqmm Refer , Sand Cushioning The Cable, Protective Covering Up To 35 Sqmm With Cpwd Pwd , Cable Laying Charges Only Size From 35 Sqmm To 95 Sqmm Refer , Sand Cushioning The Cable, Protective Covering And Refilling The Trench Etc. As Required. From 35 To 95 Sqmm With Cpwd Pwd , Cable Laying Charges Only Size From 95 Sqmm To 185 Sqmm Refer , Sand Cushioning The Cable, Protective Covering And Refilling The Trench Etc. As Required. From 95 Sqmm To 185 Sqmm With Cpwd Pwd , Cable Laying Charges Only From 185 Sqmm To 400 Sqmm Refer , Sand Cushioning The Cable, Protective Covering And Refilling The Trench Etc. As Required. From 185 Sqmm To 400 Sqmm With Cpwd Pwd , Ug Cable Laying Work. Up To 35 Sq Mm Refer , Ug Cable Laying Work 35 Sq Mm To 95 Sq Mm Refer , Ug Cable Laying Work 95 Sq Mm To 185 Sqmm Refer , Ug Cable Laying Work 185 Sq Mm To 400 Sqmm Refer , 3 1 2 X Up To 16 Sq Mm Each Or Below Refer , 3 1 2 X 25 Sq Mm 28Mm Each Refer , 3 1 2 X 35 Sq Mm 32Mm Each Refer , 3 1 2 X 50 Sq Mm 35 Mm Each Refer , 3 1 2 X 70 Sq Mm 38Mm Each Refer , 3 1 2 X 95 Sq Mm 45 Mm Each Refer , 3 1 2 X 120 Sq Mm 45 Mm Each Refer , 3 1 2 X 150 Sq Mm 50 Mm Each Refer , 3 1 2 X 185 Sq Mm 57Mm Each Refer , 3 1 2 X 225 Sq Mm 62Mm Each Refer , 3 1 2 X 240 Sq Mm 62Mmeach Refer , 3 1 2 X 300 Sq Mm 70 Mm Each Refer , 3 1 2 X 400 Sq Mm 82Mm Each Refer , Ug Cable Joining Work Labor Charges Only 3 1 2 X 25 Sq Mm Each Or Below Refer , Ug Cable Joining Work Labor Charges Only 3 1 2 X 35 Sq Mm Each Refer , Ug Cable Joining Work Labor Charges Only 3 1 2 X 50 Sq Mm Each Refer , Ug Cable Joining Work Labor Charges Only 3 1 2 X 70 Sq Mm Each Refer , Ug Cable Joining Work Labor Charges Only 3 1 2 X 95 Sq Mm Each Refer , Ug Cable Joining Work Labor Charges Only 3 1 2 X 120 Sq Mm Each Refer , Ug Cable Joining Work Labor Charges Only 3 1 2 X 150 Sq Mm Each Refer , Ug Cable Joining Work Labor Charges Only 3 1 2 X 185 Sq Mm Each Refer , Ug Cable Joining Work Labor Charges Only 3 1 2 X 225 Sq Mm Each Refer , Ug Cable Joining Work Labor Charges Only 3 1 2 X 240 Sq Mm Each Refer , Ug Cable Joining Work Labor Charges Only 3 1 2 X 300 Sq Mm Each Refer , Ug Cable Joining Work Labor Charges Only 3 1 2 X 400 Sq Mm Each Refer , Rcc Cable Root Marker H 24 X W 8 X Thickness 4 , Rcc Pipes For Road Crossing 1 Dia X 6 Length , Rcc Pipes For Road Crossing 12 Dia X 6 Length , Rcc Pipes For Road Crossing 34 Dia X 6 Length , Ug Cable Eb Service Related Work Up To 16 Sqmm Refer , Ug Cable Eb Service Related Work Above 16 To Up To 35 Sqmm Refer , Ug Cable Eb Service Related Work Above 35 Sqmm Up To 95 Sqmm Refer , Ug Cable Eb Service Related Work Above 95 Sqmm Up To 185 Sqmm Refer , 12 Mtr Himast Light Pole 160Mm Include With Labour And Foundation Materials , Copper Conductor Single Core Cable Etc As Required. Open Wiring , Copper Conductor Single Core Cable Etc As Required Concealed Wiring , 2 Way Modular Switch, Modular Plate, Cable Etc As Required. Open Wiring , Pvc Insulated Copper Conductor Single Core Cable In Surface Single Core Cable Etc As Required Concealed Wiring. , Wiring For Light Power Plug With 2 X 4 6 10 Sq Mm Fr Pvc Insulated Copper Conductor Open Wiring , Wiring For Light Power Plug With 2 X 4 6 10 Sq Mm Fr Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required Concealed Wiring , Wiring For Light Power Plug With 4 X 4 6 10 Sq Mm Fr Pvc Insulated Copper Conductor Loop Earthing As Required Open Wiring , Wiring For Light Power Plug With 4 X 4 6 10 Sq Mm Fr Pvc Insulated Copper Along With 1 No 4 Sq Mm Fr Pvc Conductor Single Core Cable For Loop Earthing As Required Concealed Wiring , Steel Conduit As Required Open Wiring , Single Core Cable In Surface Recessed Steel Conduit As Required Concealed Wiring , 2 X 1 5 Sqmm 1 X 1 5 Sqmm Earth Wire , 4 X 1 5 Sqmm 1 X 1 5 Sqmm Earth Wire , 2 X 2 5 Sqmm 1 X 1 5 Sqmm Earth Wire , 4 X 2 5 Sqmm 1 X 1 5 Sqmm Earth Wire , 2 X 4 0 Sqmm 1 X 1 5 Sqmm Earth Wire , 4 X 4 Sqmm 1 X 1 5 Sqmm Earth Wire , 4 X 6 Sqmm 2 X 6 Sqmm Earth Wire , 4 X 10 Sqmm 2 X 6 Sqmm Earth Wire , Wiring For Circuit Sub Main Wiring Along With Earth Wire With The Following Sizes Of Fr Pvc Insulated Copper Conductor, Single Core Cable In Surface Recessed Steel Conduit As Required , Directly On Ceiling Wall, Including Connection With 1 5 Sq Mm Fr Pvc Insulated, Copper Conductor, Single Core Cable And Earthling Etc. As Required , Directly On Excising Rcc Steel Ms Pipe Pole Including Connection With 1 5 Sq Mm Fr Pvc Insulated, Copper Conductor, Single Core Cable And Earthling Etc. As Required , Including Wiring The Down Rods Of Standard Length Up To 30 Cm With 1 5 Sq Mm Fr Pvc Insulated, Copper Conductor, Single Core Cable, Etc. As Required. , Including Wiring With 1 5 Sq Mm Fr Pvc Insulated, Copper Conductor, Single Core Cable, Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box , Service Board Main Board Wiring 1 , Service Board Main Board Wiring 3 , Wire Running Charges For Above 5 Meters 2 X 1 5 Sqmm 1 X 1 5 Sqmm Earth Wire , Wire Running Charges For Above 5 Meters 4 X 1 5 Sqmm 1 X 1 5 Sqmm Earth Wire , Wire Running Charges For Above 5 Meters 2 X 2 5 Sqmm 1 X 1 5 Sqmm Earth Wire , Wire Running Charges For Above 5 Meters 4 X 2 5 Sqmm 1 X 1 5 Sqmm Earth Wire , Wire Running Charges For Above 5 Meters 2 X 4 Sqmm 1 X 1 5 Sqmm Earth Wire , Wire Running Charges For Above 5 Meters 4 X 4 Sqmm 1 X 1 5 Sqmm Earth Wire , Wire Running Charges For Above 5 Meters 4 X 6 Sqmm 1 X 1 5 Sqmm Earth Wire , Wire Running Charges For Above 5 Meters 4 X 10 Sqmm 1 X 1 5 Sqmm Earth Wire , Wire Running Charges For Above 5 Meters 4 X 16 Sqmm 1 X 1 5 Sqmm Earth Wire , 200 Amps Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs2 Way 4 Way Replacing Charge , 200 Amps Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs 4Way Fixing Charge , Inclusive Of 200 Amps Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs 8 Way Replacing Charge , 200 Amps Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs 8 Way Fixing Charge , 200 Amps Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs 12 Way Replacing Charge , 200 Amps Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs 12 Way Fixing Charge , 200 Amps Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs 16 Way Replacing Charge , 200 Amps Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs 16 Way Fixing Charge Fixing Charge , Common Neutral Link, Earth Bar, Din Bar For Mounting Mcb S Up To 24 Way Replacing Charge , 200 Amps Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs 24 Way Fixing Charge Fixing Charge , Installation Of Ex.Fan On The Surface, Connection, Testing, Commissioning Etc. As Required Replacing Charge , Installation Of Ex.Fan On The Surface, Connection, Testing, Commissioning Etc. As Required Fixing Charge , Fixing Following Piano Type Switch Socket On The Existing Switch Box Cover Including Connections Etc. As Required.1 2 Way 56 Amps Switch Socket Replacing Charge , Fixing Following Piano Type Switch Socket On The Existing Switch Box Cover Including Connections Etc. As Required.1 2 Way 56 Amps Switch Socket Fixing Charge , Fixing Following Piano Type Switch Socket On The Existing Switch Box Cover Including Connections Etc. As Required.1 Way 16 20 Amps Switch Socket Replacing Charge , Fixing Following Piano Type Switch Socket On The Existing Switch Box Cover Including Connections Etc. As Required.1 Way 16 20 Amps Switch Socket Fixing Charge , Fixing Following Electronic Type Regulator On The Existing Switch Box Cover Including Connections Etc. As Required.1 Switch Socket Model Replacing Charge , Fixing Following Electronic Type Regulator On The Existing Switch Box Cover Including Connections Etc. As Required.1 Switch Socket Model Fixing Charge , Fixing 5 A Ceiling Rose On The Existing Junction Box Wooden Block Including Connection Etc.As Required Replacing Charge , Fixing 5 A Ceiling Rose On The Existing Junction Box Wooden Block Including Connection Etc.As Required Fixing Charge , Fixing 5 A Brass Batten Angle Holder Including Connection Etc. As Required Replacing Charge , Fixing 5 A Brass Batten Angle Holder Including Connection Etc. As Required Fixing Charge , Making Connections, Etc. As Required. 63 Amps Replacing Charge , Making Connections, Etc. As Required. 63 Amps Fixing Charge , Making Connections, Etc. As Required. 125100 Amps Replacing Charge , Making Connections, Etc. As Required. 125100 Amps Fixing Charge , Makingconnections, Etc. As Required. 160 Amps Fixing Charge Connections, Etc. As Required. 200 Amps Replacing Charge , Makingconnections, Etc. As Required. 200 Amps Fixing Charge , Makingconnections, Etc. As Required. 400 Amps Replacing Charge , Makingconnections, Etc. As Required. 400 Amps Fixing Charge , 63 Amps Replacing Charge , 63 Amps Fixing Charge , 100 125 160 Amps Replacing Charge , 100 125 160 Amps Fixing Charge , 200 Amps Replacing Charge , 200 Amps Fixing Charge , 400 Amps Replacing Charge , 400 Amps Fixing Charge , Fixing Following Capacity 4 P Change Over Switch With Enclosure Unit Including Drilling Holes In Walls Ms Frame Wooden Board, Panel, Making Connections, Etc. As Required.63 160 Amps Replacing Charge , Fixing Following Capacity 4 P Change Over Switch With Enclosure Unit Including Drilling Holes In Walls Ms Frame Wooden Board, Panel, Making Connections, Etc. As Required.63 160 Amps Fixing Charge , Fixing Following Capacity 4 P Change Over Switch Enclosure Unit Including Drilling Holes In Walls Ms Frame Wooden Board, Panel, Making Connections, Etc. As Required. 200 Amps Replacing Charge , Fixing Following Capacity 4 P Change Over Switch Enclosure Unit Including Drilling Holes In Walls Ms Frame Wooden Board, Panel, Making Connections, Etc. As Required. 200 Amps Fixing Charge , Single Pole Replacing Charge , Single Pole Fixing Charge , Double Pole Replacing Charge , Double Pole Fixing Charge , Triple Pole 4 Pole Replacing Charge , Triple Pole 4 Pole Fixing Charge , Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps Replacing Charge , Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps Fixing Charge , Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps Replacing Charge , Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps Fixing Charge , Fixing Following Rating, Four Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps Replacing Charge , Fixing Following Rating, Four Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps Fixing Charge , Fixing Following Rating, Four Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 Amps Replacing Charge , Fixing Following Rating, Four Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 Amps Fixing Charge , Fixing Tp Sheet Steel Enclosure On Surface Recess Along With 162532Amps 415 Replacing Charge , Fixing Tp Sheet Steel Enclosure On Surface Recess Along With 162532Amps 415 Volts C Curve Tp Mcb Fixing Charge , Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required. Replacing Charge , Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required. Fixing Charge , Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required. Replacing Charge , Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required. Fixing Charge , Suitable For 415 Volts, 3 Phase, 4 Wire, 50 Hz, A.C. Thrust Pads Including Jointing, And Earthing With 2 Runs Of Galvanized Iron Strips Etc. As Required. 200 Amps Replacing Charge , Suitable For 415 Volts, 3 Phase, 4 Wire, 50 Hz, A.C. Earthing With 2 Runs Of Galvanized Iron Strips Etc. As Required. 200 Amps Fixing Charge , Tpn Disconnector Fsu And Hrc Fuses, Connections, Earthing Etc. 16 32 63 100 Amps Tpn Replacing Charge , Tpn Disconnector Fsu And Hrc Fuses, Connections, Earthing Etc. 16 32 63 100 Amps Tpn Fixing Charge , Charcoal Coke And Salt As Required. Providing And Fixing 4.00 8.00 Mm Dia With Existing Surface Recessed Conduit Submain Wiring Cable As Required. , Charcoal Coke And Salt As Required. Providing And Fixing 4.00 Mm 8.00 Dia Surface Recessed Conduit Submain Wiring Cable As Required. , Earthing With Gi Earth Pipe 1 Meter Long, 40Mm Dia Including Accessories And Providing Masonry Enclosure With A Cover Plate As Required , Earthing With Gi Earth Pipe 2 Meters Long , 40Mm Dia Including Accessories And Providing Masonry Enclosure With Cover Plate As Required , Earthing With Gi Earth Pipe 3 Meter Long , 40Mm Dia Including Accessories And Providing Masonry Enclosure With Cover Plate As Required , Laying Earth Connection From Earth Electrode With 4.00 Mm Dia Copper Wire In 15 Mm Dia Gi Pipe From Earth Electrode, As Required , Laying Earth Connection From Earth Electrode With 25 Mm X 5 Mm Dia Copper Gi Flat Strip In 15 Mm Dia Gi Pipe From Earth Electrode, As Required , Fixing 4.00 Mm Dia Copper Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface Recessed Conduit Sub Maincable As Required , Laying 0.5 Mm Telephone Line Wiring In Surface Recessed Pvc Conduit , Drawing Lan Cable Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated , Labour Rate For Electrical Helper , Labour Rate For Excavator , Ups Battery Up To 3 Kva Dismantling Charge , Ups Battery Up To 3 Kva Installation Charge , Ups Battery Above 3 Kva To 5 Kva Dismantling Charge , Ups Battery Above 3 Kva To 5 Kva Installation Charge , Ups Battery Above 5 Kva To 10 Kva Dismantling Charge , Ups Battery Above 5 Kva To 10 Kva Installation Charge , Ups Battery Above 10 Kva Dismantling Charge , Ups Battery Above 10 Kva Installation Charge , Pipe Size 3 Inches Alloy Fully Galvanized Iron Total Quantity : 177
|