|
Section 6. Laboratary Items Non Ekl Erl 2025-26-27 Laboratory Non Ekl Erl Item List Part - 3- Plastic Cap Compatible With Meril Autoquant 400 Analyer, Board Assy_Md_Lamp_Autq4i_Rev-0, Board Assy_Md_Pump & R-Jack_Autq4i_Rev-0, Stirrer Motor Opto Cable Assy Rotation_A, Stirrer Motor Opto Cable Assy Up-Dn_Aq-2, Syringe Motor Opto Cable Assembly_Aq-200, Arm Up-Dn Motor Opto Cable Assembly_Aq-2, Laundry Manifold Assembly_Aq-200I, R1 / Sample Arm Assy-Aq-400I, Asp ( Sample ) Assy-Aq-400I, Assembly Stirrer 1 For Aq-400I, Assembly Stirrer 2 For Aq-400I, Assembly Laundry (W/O Laundry Probes ) -Aq-400I, Water Pump Assy ( Single Head )_Aq-400I, Solenoid Valve Assembly_Aq-400I, Rca Jack Conn. Cable Assembly _Aq-400I, Waste Storage Drain Assy-Aq 400I, Sample Tray Assembly-Aq-400I, Reagent Tray Assembly-Aq-400I, R1 Syringe Assembly-Aq-400I, R2 Syringe Assembly-Aq-400I, Sample Syringe Assembly-Aq-400I, Waste Sensor Assembly With Spigot - Aq-4, Detergent Sensor Assy With Spigot Aq-400, Biohazarduos Sensor Assy With Spigot-Aq-, Biohazardous Can Assy With Spigot-Aq-400, Assy. Peltier For Cooling -Aq-400I, Board Assy Main Board Md_Mb_Aq_400I, Board Assy Liquid Md_Lls_Aq_400I, Board Asssy Motor Md_Smd_Aq_400I, Board Assy Barcode Md_Bcr_Aq_400I, Board Assy Photo Mtr Md_Phm_Aq_400I, Board Assy Rct / Rgt Opto-2Md_Op_Aq_400I, Arm Rotation Motor Assembly For Aq_400I, Assembly Laundry (With Laundry Probes ), Electrical Assy. Stirrer Dc Motor_Aq_400, Assembly Rct For Aq_400I, Assembly Rgt For Aq_400I, Assembly Probe Arm For Aq_400I, Laundry Tubing Set For Aq_400I, Aspiration Laundry Tubing Set_Aq_400I, Dispensing Laundry Tubing Set_Aq_400I, Complete Tubing Set For Aq_400I, Assembly Pressure Tank With Lld Sensor_A, Laundry Pump Assembly ( Double Head )_Aq, Sys Cooling Pump For Aq_400I, Solenoid Valve Assembly_Aq_400I, Micro Switch Cable Assy. For Arm Probe_, Electrical Assy. Lamp Blower 24V_Aq_400I, Rct Motor Assembly For Aq_400I, Rgt Motor Assembly For Aq_400I, Up/Dn Motor Assembly For Aq_400I ( R1/R, Rotation Motor Assembly For Aq_400I ( R, Assembly Probe Arm R1/R2- Aq_400I, 9-Ch Fiber Optics_385Mm Long_Aq400i, Rgt Tray Cover_Aq-400I, Acrylic Dome_Aq-400I_Md11-00-00-161, Thermostat 50ºc Nc 250V 5A, Universal Smps 24V/(13-15A), Peristaltic Dc Pump ,12Vdc, R1-R2 Probe_Aq400i_Md13-00-00-093, Syringe Pump 100Ul _5001-12-Dm-P/64C, Syringe Pump 500Ul_5005-12-Dm-P/64C, Universal Smps 12V/(20A), Reference Electrode Housing Dd-62002, Sample Detector Dd-62006, Peristaltic Pump Head Dd-61105, Cpu Board Dd-61103, Electrode Cable Assembly Dd-61104, End Cap Inlet Cn-A5004, End Cap Outlet Cn-A5005, Peristaltic Pump Dd-61101, Pinch Valve Dd-61102, Reduction Tube Fitting Cn-5036, Pump Set Of 3 Dd-61100, Di Water Spigot Assembly With Sensor_Aut, Biohazardous Cane Assy With Spigot-Aq-400, Waste Cane Assy With Spigot_Aq-400I, Detergent Cane Assy With Spigot Aq-400I, Laundry Probe_Washing_Aq_400I, Laundry Probe_Suction_Aq_400I, Laundry Probe_ Drier_Aq_400I, Lamp Assembly For Aq-400I, Reaction Cuvette Code Or 001 For Aq, Dryer_6.4X5.4_Md11-00-00-264, Stirrer Paddle_Aq-200I_Md11-00-00-149, Cuvette Holder_Aq400i_Md13-00-00-019, Sample Probe_Aq400i_Md13-00-00-094, Sample Cup For Aq-400I, Reference Electrode Dd-61001, Sodium Electrode Dd-62003, Potassium Electrode Dd-62004, Chloride Electrode Dd-62005, 2Mm X 4Mm Pharmed Tubing (1Inch) Cn-4825, Fluid Pack Dd-61012, Standard B (100Ml) Dd-61013, Urine Diluent (500Ml) Av-Bp0344d, Cleaner (100Ml) Av-Bp1025d, Conditioner (100Ml) Av-Bp0380d, Mission Clinicheck Normal Level Dd-93001, Mission Clinichk Abnormal Level Dd-93002, Mission Clinicheck Dual Level Dd-93012, Deproteinizer (100Ml) Av-Bp0521d, Sample Cup Cn-A4801, Micropipette Tips For 5 Ml Capacity Transparent Pack Of 500 Tips, Ph Meter, Tds Meter, Digital Thermohygrometer With Temperature And Humidity Measurement, Digital Thermo Meter For Temperature Measurement, Plastic Puncture Proof Containor For Sharp Waste Disposal 500 Ml, Plastic Biomedical Waste Container 20-25L With Foot Operator, Red, Plastic Biomedical Waste Container 20-25L With Foot Operator, Yellow, Plastic Biomedical Waste Container 20-25L With Foot Operator, Green, Plastic Test Tube 5-8 Ml, Kit Hiv Rapid Test Kit 4Th Generation•Should Detect P24 Antigen & Antibodies To Hiv 1 & Hiv 2 In Early Seroconversion Period•Product Should Have Positive & Negative Controlls•Adequate Literature Dealing The Components, Methodologies Validity Criteria & Performance Characteristics Of The Product Should Be Provided With Each Kit•Suitable For Processing Even Single Sample•Should Have Sensitivity Atleast 99.8 Percent & Specificity At Least 98 Percent•Supplier/Local Agent Should Have Facility For Storage At 2 8 C•Total Procedure Time Should Be Completed Within 30 Minutes•Should Have Long Expiry, 50Test Kit, Malaria Antigen Testing Kit: Immunochomatographic, For P.Falci & P.Vivax Rdt For Detection & Differentiation Of P. Falciparum & P. Vivax. - True Speciation. , Uses Highly Sensitive Monoclonal Antibodies Against P. F Hrp 2 & P. Vivax Pldh., Rapid Two Step 15 Minutes Assay., Uses Hbr - Interference Protected From Heterophile Antibodies - Ensure Highly Specific Result., Sensitivity & Specificity≫98 Percent.Evaluated By I.C.M.R. ( N.I.Mr), (Us Fda Approved / Ce Certified) 1X50 Test, Kit Hcv Rapid 4Th Generation Kit: Kit Detection Of Total Antibodies To Hcv In Serum/Plasma;Antigen Derived From Multiple Genotype (Core, Ns3, Ns4&Ns5);Recombinant Antigen;Ce Approved, Wash Bottle For Tulip Elisa Washer, Waste Bottle For Tulip Elisa Washer, Carbon Biotips 1100 Ul (For Biorad Auto Elisa Machine), Carbon Biotips 300 Ul (For Biorad Auto Elisa Machine), Distilled Water 1X10 Litre "0" Tds 100 Percent Pure, Single Blood Bags Cpda 350Ml:Bio Compatibility Of The Plastic Container Must Be Certified By The Manufacturer And Supported By Test Reports Of The Following Cell Culture Cytotoxicity, Haemolysis, Systemic Injection, Sensitisation, Intracutaneous Injection.Stability Studies Data To Prove 3 Years Shelf Life Shouldbe Produced.Ce Mark And Iso 9002 Quality System Certification.Conformity To Iso 3826 International Product Std.For Blood Bags.In_House R&D Center Recognised By The Govt. Of India.Marketstanding Of 5Yrs .Air Content:Container Should Not Exceed10ml.External Sterility Of The Blood Bags Must Be Assured.The Firm Must Submit Published Materials In The Scientific Journals In Favours Of The Quality Of Blood Bags. Comply To I.P. Must Produce Qc Pass Certificate With Each Lot. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor, Double Blood Bag Cpda 350Ml: Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485:1996 Quality System Certification .Conformity To Iso 3826 International Product Standard For Blood Bags.Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time, Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds.Markings In The Tubing : Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable With Out Any Strains To Eyes. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor.Must Produce Qc Pass Certificate With Each Lot., Double Blood Bag Cpda 350Ml: Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485:1996 Quality System Certification .Conformity To Iso 3826 International Product Standard For Blood Bags.Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time, Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds.Markings In The Tubing : Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable With Out Any Strains To Eyes. Must Produce Qc Pass Certificate With Each Lot., Double Blood Bag Cpd With Additive Solution (Sagm) 350 Ml: Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485:1996 Quality System Certification .Conformity To Iso 3826 International Product Standard For Blood Bags.Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time, Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds.Markings In The Tubing : Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable With Out Any Strains To Eyes. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor.Must Produce Qc Pass Certificate With Each Lot., Double Blood Bag Cpd With Additive Solution (Sagm) 350 Ml: Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485:1996 Quality System Certification .Conformity To Iso 3826 International Product Standard For Blood Bags.Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time, Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds.Markings In The Tubing : Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable With Out Any Strains To Eyes. Must Produce Qc Pass Certificate With Each Lot., Double Blood Bag Cpda 450Ml : Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485:1996 Quality System Certification. Conformity To Iso 3826 International Product Standard For Blood Bags. Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time. Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds. Markings In The Tubing: Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable Without Any Strains To Eyes. Comply To I.P. Must Produce Qc Pass Certificate With Each Lot. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor., Double Blood Bag Cpda 450 Ml : Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485:1996 Quality System Certification. Conformity To Iso 3826 International Product Standard For Blood Bags. Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time. Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds. Markings In The Tubing: Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable Without Any Strains To Eyes. Comply To I.P. Must Produce Qc Pass Certificate With Each Lot., Double Blood Bag Cpd With Additive Solution (Sagm) 450Ml : Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485:1996 Quality System Certification. Conformity To Iso 3826 International Product Standard For Blood Bags. Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time. Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds. Markings In The Tubing: Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable Without Any Strains To Eyes. Comply To I.P. Must Produce Qc Pass Certificate With Each Lot., Double Blood Bag Cpd With Additive Solution (Sagm) 450Ml : Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485:1996 Quality System Certification. Conformity To Iso 3826 International Product Standard For Blood Bags. Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time. Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds. Markings In The Tubing: Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable Without Any Strains To Eyes. Comply To I.P. Must Produce Qc Pass Certificate With Each Lot. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor., Triple Blood Bag Cpda Without Sagm 350Ml: Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485:1996 Quality System Certification .Conformity To Iso 3826 International Product Standard For Blood Bags.Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time, Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds.Markings In The Tubing : Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable With Out Any Strains To Eyes. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor.Must Produce Qc Pass Certificate With Each Lot., Triple Blood Bag Cpda Without Sagm 350Ml: Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485:1996 Quality System Certification .Conformity To Iso 3826 International Product Standard For Blood Bags.Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time, Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds.Markings In The Tubing : Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable With Out Any Strains To Eyes. Must Produce Qc Pass Certificate With Each Lot., Triple Blood Bag Cpd With Sagm 450 Ml: Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485:1996 Quality System Certification .Conformity To Iso 3826 International Product Standard For Blood Bags.Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time, Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds.Markings In The Tubing : Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable With Out Any Strains To Eyes. Comply To I.P. Must Produce Qc Pass Certificate With Each Lot. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor., Triple Blood Bag Cpd With Sagm 450Ml: Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485:1996 Quality System Certification .Conformity To Iso 3826 International Product Standard For Blood Bags.Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time, Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds.Markings In The Tubing : Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable With Out Any Strains To Eyes. Comply To I.P. Must Produce Qc Pass Certificate With Each Lot., Triple Blood Bag Cpd With Sagm 350Ml Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485: 1996 Quality System Certification. Conformity To Iso 3826 International Product Standard For Blood Bags. Needle Is Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time. Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds. Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable With Out Any Strains To Eyes. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor.Must Produce Qc Pass Certificate With Each Lot., Triple Blood Bag Cpd With Sagm 350Ml Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485: 1996 Quality System Certification. Conformity To Iso 3826 International Product Standard For Blood Bags. Needle Is Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time. Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds. Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable With Out Any Strains To Eyes. Must Produce Qc Pass Certificate With Each Lot., Triple Blood Bag Cpda Without Sagm 450Ml : Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485:1996 Quality System Certification .Conformity To Iso 3826 International Product Standard For Blood Bags. Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time, Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds. Markings In The Tubing : Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable Without Any Strains To Eyes. Comply To I.P. Must Produce Qc Pass Certificate With Each Lot. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor., Triple Blood Bag Cpda Without Sagm 450Ml : Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485:1996 Quality System Certification .Conformity To Iso 3826 International Product Standard For Blood Bags. Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time, Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds. Markings In The Tubing : Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable Without Any Strains To Eyes. Comply To I.P. Must Produce Qc Pass Certificate With Each Lot., Quadruple Blood Bagscpd With Sagm 450Ml: Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485:1996 Quality System Certification .Conformity To Iso 3826 International Product Standard For Blood Bags.Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time, Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds.Markings In The Tubing : Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable With Out Any Strains To Eyes. Comply To I.P. Must Produce Qc Pass Certificate With Each Lot. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor., Quadruple Blood Bagscpd With Sagm 450Ml: Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485:1996 Quality System Certification .Conformity To Iso 3826 International Product Standard For Blood Bags.Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time, Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds.Markings In The Tubing : Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable With Out Any Strains To Eyes. Comply To I.P. Must Produce Qc Pass Certificate With Each Lot., Top & Bottom Quadruple Blood Bag 450Ml: Quadruple Top&Bottom Bag To Collect Blood Component Through Buffy Method, Must Comply With Iso 13485, Iso 9001&Ce Mark, Mother Bag Should Be With 0.45Mm Thickness To Prevent Breakage During Centrifugation&The Innerdiameter Of The Transfer Tube From Mother Bag To Sagm Bag Should Be With 3.8Id To Provide Easy Flow Of Component.Needle Should Be Withtriple Bevel Desinged To Reduce Penitration Force Less Than 16G For Painless Vein Puncture& The Outer Cover Shouldbe Hard Enough To Protect The Needle During The Transportation .Blood Bags Should Have Hot Markings In All Tubes Of The Transfer Bags.Tubes Of Plasma, Platelet&Redcells Should Have Hot Marking Numbers To Ensure Traceability. Batch Number Should Be Printed With Barcode. Pharmacopeia Shouid Be Mentioned Iabel. Platelet Storage Bag Should Be Properly Labeled For The Days Of Storage Of Platelet. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor.Must Produce Qc Pass Certificate With Each Lot., Top & Bottom Quadruple Blood Bag 450Ml: Quadruple Top&Bottom Bag To Collect Blood Component Through Buffy Method, Must Comply With Iso 13485, Iso 9001&Ce Mark, Mother Bag Should Be With 0.45Mm Thickness To Prevent Breakage During Centrifugation&The Innerdiameter Of The Transfer Tube From Mother Bag To Sagm Bag Should Be With 3.8Id To Provide Easy Flow Of Component.Needle Should Be Withtriple Bevel Desinged To Reduce Penitration Force Less Than 16G For Painless Vein Puncture& The Outer Cover Shouldbe Hard Enough To Protect The Needle During The Transportation .Blood Bags Should Have Hot Markings In All Tubes Of The Transfer Bags.Tubes Of Plasma, Platelet&Redcells Should Have Hot Marking Numbers To Ensure Traceability. Batch Number Should Be Printed With Barcode. Pharmacopeia Shouid Be Mentioned Iabel. Platelet Storage Bag Should Be Properly Labeled For The Days Of Storage Of Platelet. Must Produce Qc Pass Certificate With Each Lot., Quadruple Blood Bags Cpda Without Sagm 450 Ml: Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485:1996 Quality System Certification .Conformity To Iso 3826 International Product Standard For Blood Bags. Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time, Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds. Markings In The Tubing : Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable Without Any Strains To Eyes. Comply To I.P. Must Produce Qc Pass Certificate With Each Lot. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor.., Quadruple Blood Bags Cpda Without Sagm 450: Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485:1996 Quality System Certification .Conformity To Iso 3826 International Product Standard For Blood Bags. Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time, Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds. Markings In The Tubing : Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable Without Any Strains To Eyes. Comply To I.P. Must Produce Qc Pass Certificate With Each Lot., Quadruple Blood Bag Cpd With Sagm 350Ml– Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485: 1996 Quality System Certification. Conformity To Iso 3826 International Product Standard For Blood Bags. Needle Is Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time. Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds. Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable With Out Any Strains To Eyes. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor.Must Produce Qc Pass Certificate With Each Lot., Quadruple Blood Bag Cpd With Sagm 350Ml– Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485: 1996 Quality System Certification. Conformity To Iso 3826 International Product Standard For Blood Bags. Needle Is Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time. Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds. Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable With Out Any Strains To Eyes. Must Produce Qc Pass Certificate With Each Lot., Quadruple Blood Bags Cpda Without Sagm 350Ml: Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485:1996 Quality System Certification .Conformity To Iso 3826 International Product Standard For Blood Bags.Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time, Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds.Markings In The Tubing : Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable With Out Any Strains To Eyes. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor.Must Produce Qc Pass Certificate With Each Lot., Quadruple Blood Bags Cpda Without Sagm 350Ml: Ce Mark, Iso 9001 2000, Directive 93/42/Eec, Iso 13485:1996 Quality System Certification .Conformity To Iso 3826 International Product Standard For Blood Bags.Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time, Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds.Markings In The Tubing : Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable With Out Any Strains To Eyes. Must Produce Qc Pass Certificate With Each Lot., Transfer Bag: Plastic Material Should Be With Less Leaching Effect. Tubing Should Have Spike To Insert Into Transfusion Port. Tubing Should Have Break Of Valve To Retain Air Inside The Bag Inner Surface Of The Bag Should Not Stick During Transfer Of Component. Product Should Be Steam Sterilized. Not Eto Sterilized. Sterility Of The Product Should Be Ensured. Iso 3826 Certified. Comply To I.P. Must Produce Qc Pass Certificate With Each Lot. 300 Ml, Top And Bottom Quadruple Blood Bag With Integrated Filters For Red Cell:( 450Ml )Top And Bottom Bag With Inline Filters To Prepare To Blood Component Through Buffy Method And To Get Leukodepleted Red Cell., It Should Have Needle Injury Protectore, Predonation Bag And Leur Adaptor To Ensure More Safety., Contain Hot Marking Numbers In Tubes Of All Bags Including Red Cell, Plasma And Platelet., Mother Bag Should Be With 0.45 Mm Thickness To Prevent Breakage During Centrifugation And The Inner Diameter Of The Transfer Tube From Mathor Bag To Sagm Bag Is With 3.8 Id To Provide Easy Flow Of The Componet, Integrated Filters Should Be Made Of Biocopatible Polyurethane Material To Ensure The Quality Of Component Filtration. Integrated Filters Should Be With Very Soft Housing To Avoid Breakage During Centrifugation., Integrated Filter Should Have A Clamp Attached To The Filters To Make Priming Procedure More Comfortable., Recovery Of Red Cell After Filtration Should Be More Than 90 Percent., Each Inline Filter Should Be Placed In A Separate Casing To Maintain Integrity And Shape Of Inline Filters. Must Produce Qc Passed Certificate With Each Lot., Top And Bottom Quadruple Blood Bag With Integrated Filters For Red Cell:( 350Ml )Top And Bottom Bag With Inline Filters To Prepare To Blood Component Through Buffy Method And To Get Leukodepleted Red Cell., It Should Have Needle Injury Protectore, Predonation Bag And Leur Adaptor To Ensure More Safety., Contain Hot Marking Numbers In Tubes Of All Bags Including Red Cell, Plasma And Platelet., Mother Bag Should Be With 0.45 Mm Thickness To Prevent Breakage During Centrifugation And The Inner Diameter Of The Transfer Tube From Mathor Bag To Sagm Bag Is With 3.8 Id To Provide Easy Flow Of The Componet, Integrated Filters Should Be Made Of Biocopatible Polyurethane Material To Ensure The Quality Of Component Filtration. Integrated Filters Should Be With Very Soft Housing To Avoid Breakage During Centrifugation., Integrated Filter Should Have A Clamp Attached To The Filters To Make Priming Procedure More Comfortable., Recovery Of Red Cell After Filtration Should Be More Than 90 Percent., Each Inline Filter Should Be Placed In A Separate Casing To Maintain Integrity And Shape Of Inline Filters. Must Produce Qc Passed Certificate With Each Lot., Top And Bottom Quadruple Blood Bag With Integrated Filters For Red Cell:( 450Ml )Top And Bottom Bag With Inline Filters To Prepare To Blood Component Through Buffy Method And To Get Leukodepleted Red Cell., Contain Hot Marking Numbers In Tubes Of All Bags Including Red Cell, Plasma And Platelet., Mother Bag Should Be With 0.45 Mm Thickness To Prevent Breakage During Centrifugation And The Inner Diameter Of The Transfer Tube From Mathor Bag To Sagm Bag Is With 3.8 Id To Provide Easy Flow Of The Componet, Integrated Filters Should Be Made Of Biocopatible Polyurethane Material To Ensure The Quality Of Component Filtration. Integrated Filters Should Be With Very Soft Housing To Avoid Breakage During Centrifugation., Integrated Filter Should Have A Clamp Attached To The Filters To Make Priming Procedure More Comfortable., Recovery Of Red Cell After Filtration Should Be More Than 90 Percent., Each Inline Filter Should Be Placed In A Separate Casing To Maintain Integrity And Shape Of Inline Filters. Must Produce Qc Passed Certificate With Each Lot., Top And Bottom Quadruple Blood Bag With Integrated Filters For Red Cell:( 350Ml )Top And Bottom Bag With Inline Filters To Prepare To Blood Component Through Buffy Method And To Get Leukodepleted Red Cell., Contain Hot Marking Numbers In Tubes Of All Bags Including Red Cell, Plasma And Platelet., Mother Bag Should Be With 0.45 Mm Thickness To Prevent Breakage During Centrifugation And The Inner Diameter Of The Transfer Tube From Mathor Bag To Sagm Bag Is With 3.8 Id To Provide Easy Flow Of The Componet, Integrated Filters Should Be Made Of Biocopatible Polyurethane Material To Ensure The Quality Of Component Filtration. Integrated Filters Should Be With Very Soft Housing To Avoid Breakage During Centrifugation., Integrated Filter Should Have A Clamp Attached To The Filters To Make Priming Procedure More Comfortable., Recovery Of Red Cell After Filtration Should Be More Than 90 Percent., Each Inline Filter Should Be Placed In A Separate Casing To Maintain Integrity And Shape Of Inline Filters. Must Produce Qc Passed Certificate With Each Lot., Top & Bottom Quadruple Blood Bag 350Ml: Quadruple Top&Bottom Bag To Collect Blood Component Through Buffy Method, Must Comply With Iso 13485, Iso 9001&Ce Mark, Mother Bag Should Be With 0.45Mm Thickness To Prevent Breakage During Centrifugation&The Innerdiameter Of The Transfer Tube From Mother Bag To Sagm Bag Should Be With 3.8Id To Provide Easy Flow Of Component.Needle Should Be Withtriple Bevel Desinged To Reduce Penitration Force Less Than 16G For Painless Vein Puncture& The Outer Cover Shouldbe Hard Enough To Protect The Needle During The Transportation .Blood Bags Should Have Hot Markings In All Tubes Of The Transfer Bags.Tubes Of Plasma, Platelet&Redcells Should Have Hot Marking Numbers To Ensure Traceability. Batch Number Should Be Printed With Barcode. Pharmacopeia Shouid Be Mentioned Iabel. Platelet Storage Bag Should Be Properly Labeled For The Days Of Storage Of Platelet. Must Produce Qc Pass Certificate With Each Lot., Top & Bottom Quadruple Blood Bag 350Ml: Quadruple Top&Bottom Bag To Collect Blood Component Through Buffy Method, Must Comply With Iso 13485, Iso 9001&Ce Mark, Mother Bag Should Be With 0.45Mm Thickness To Prevent Breakage During Centrifugation&The Innerdiameter Of The Transfer Tube From Mother Bag To Sagm Bag Should Be With 3.8Id To Provide Easy Flow Of Component.Needle Should Be Withtriple Bevel Desinged To Reduce Penitration Force Less Than 16G For Painless Vein Puncture& The Outer Cover Shouldbe Hard Enough To Protect The Needle During The Transportation .Blood Bags Should Have Hot Markings In All Tubes Of The Transfer Bags.Tubes Of Plasma, Platelet&Redcells Should Have Hot Marking Numbers To Ensure Traceability. Batch Number Should Be Printed With Barcode. Pharmacopeia Shouid Be Mentioned Iabel. Platelet Storage Bag Should Be Properly Labeled For The Days Of Storage Of Platelet. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor.Must Produce Qc Pass Certificate With Each Lot., Primary Cpda Paediatric Bags With 4 Satellite Bags Each Of 100Ml Capacity. Iso 3826 Certified. Comply To I.P. Must Produce Qc Pass Certificate With Each Lot., Red Cell Leukodepletion Filters With Attached Transfer Bag-Lab Side, Anti A. Blood Grouping Serum (Monoclonal Ig M) For A Rapid Slide And Tube Test. Avidity Period : 3 5Sec. Max. Hbs Ag And Hiv Free. Tube Titer With A1 Cells Should Be More Than Or Equal To 1:256, No Cross Reactivity With B Or O Group Cells, Should Be Ce Certified. 5 Ml., Anti B. Blood Grouping Serum (Monoclonal Ig M) For A Rapid Slide And Tube Test. Tube Titer With B Cells Should Be More Than Or Equal To 1:256. Avidity Period : 3 5 Sec. Max. Hbs Ag And Hiv Free.Should Be Ce Certified, 5 Ml, Anti A1 Lectin With Tube Titer With A1 Cells Should Be 1:16, No Reaction With A2 Or A2b Cells, Clear Lectin Preparation, Non Turbid, For A Rapid Slide And Tube Test. Avidity Period : 3 5 Sec. Max. Hbs Ag And Hiv Free. Should Be Ce Certified, 5 Ml., Anti Ab. Blood Grouping Serum (Monoclonal Ig M) For A Rapid Slide And Tube Test. Should Have A Mixture Of Monoclonal Antibodies With True A, B. Should Detect Weaker Subgroups Of A. Avidity Period : 3 5 Sec. Max. Hbs Ag And Hiv Free. Should Be Ce Certified, 5 Ml., Anti D. Blood Grouping Serum (Monoclonal Ig M) For A Rapid Slide And Tube Test. Avidity Period : 5 10 Sec. Max.Hbs Ag And Hiv Free.Should Be Ce Certified, 5 Ml., Anti H Lectin With Optimized Titer To Give Calibrated Graded Reactivity O≫A2≫A2b≫B≫A1≫A1b, Clear Lectin Preparation, Non Turbid, No Reaction With Bombay Phenotype Samples, For A Rapid Slide And Tube Test. Avidity Period : 3 5 Sec. Max. Should Be Ce Certified, Hbs Ag And Hiv Free. 5 Ml, Anti A.+ Anti B+ Anti D (Igm + Igg ) 5Ml Combo Pack: Blood Grouping Serum (Monoclonal Ig M) For A Rapid Slide And Tube Test. Avidity Period : 3 5Sec. Max. Hbs Ag And Hiv Free. Tube Titer With A1 Cells Should Be More Than Or Equal To 1:256, No Cross Reactivity With B Or O Group Cells, Should Be Ce Certified. 5 Ml. Anti B. Blood Grouping Serum (Monoclonal Ig M) For A Rapid Slide And Tube Test. Tube Titer With B Cells Should Be More Than Or Equal To 1:256. Avidity Period : 3 5 Sec. Max. Hbs Ag And Hiv Free.Should Be Ce Certified, 5 Mlanti D. (Blend, Igm+Igg), High Avidity (5 6 Sec.), Non Recctive With Rh Negative Sample, Should Have A Blend Of 3 Monoclonal Antibodies (2 Igm + 1 Ig G), Should Pick Up Spectrum Of D Varient, Should Be Ce Certified, Slide Titer With O R1r1 Cells Should Be ≫ 1:16, Tube Titer With O R1r1 Cells Should Be ≫ 1:256. 5Ml., Anti A.+ Anti B+ Anti D (Igm + Igg ) 10 - 15 Ml Combo Pack: Blood Grouping Serum (Monoclonal Ig M) For A Rapid Slide And Tube Test. Avidity Period : 3 5Sec. Max. Hbs Ag And Hiv Free. Tube Titer With A1 Cells Should Be More Than Or Equal To 1:256, No Cross Reactivity With B Or O Group Cells, Should Be Ce Certified.10 - 15 Ml Anti B. Blood Grouping Serum (Monoclonal Ig M) For A Rapid Slide And Tube Test. Tube Titer With B Cells Should Be More Than Or Equal To 1:256. Avidity Period : 3 5 Sec. Max. Hbs Ag And Hiv Free.Should Be Ce Certified, 10 - 15 Ml Anti D. (Blend, Igm+Igg), High Avidity (5 6 Sec.), Non Recctive With Rh Negative Sample, Should Have A Blend Of 3 Monoclonal Antibodies (2 Igm + 1 Ig G), Should Pick Up Spectrum Of D Varient, Should Be Ce Certified, Slide Titer With O R1r1 Cells Should Be ≫ 1:16, Tube Titer With O R1r1 Cells Should Be ≫ 1:256. 10 - 15 Ml, Gel Card Matrix Abo Forward Group Card For Tulip Gel Matrix Machine, Gel Card Matrix Abo Reverse Grouping & Card 24 Card For Tulip Gel Matrix Machine, Gel Card Matrix Ahg Crossmatch Card 24 Card For Tulip Gel Matrix Machine, Gel Card Matrix Diluent 2 (Liss) 250 Ml For Tulip Gel Matrix Machine, Gel Card Matrix Neonete Grouping Card 24 Card For Tulip Gel Matrix Machine, Three Cell Panel For Screening In Column Agglutination System, Eleven Cell Panel For Screening In Column Agglutination System, Copper Sulphate Ar/Gr 500 G.Pkt., Cell Counter Reagent Erba H360 Dil (1X20 Lit), Cell Counter Reagent H360 Lyse (1X500 Ml), Cell Counter Reagent Erba Elite H Clean (1X50 Ml), Cell Counter Control H360, Cell Counter Cailbrator H360, Calcium Chloride For Coagulometer-10Ml Vail, Cuvatte For Hemostar Coagulometer 2.0, Factor 8 Deficient Plasma (Hemostar)(1Ml X 3), Lyoplastin-Ls 5Ml X 10 Vial, Celin - Se 3Ml X 12 Vial, Fibroquant -1Ml X 4 Vial, Cuvatte For Haemocue 301 (For Hb Estimatimation), Cuvatte For Compolab Tm-Fresenius Kabi (For Hb Estimate), Hb Strips Compatible With Hbcheck Meter Manufactured By Biosense, Mumbai., Watman Filter Paper Size: 100 Nos (185Mm Cat No. 1001-185), Control Capsule Ph Meter (4.01), Control Capsule Ph Meter (9.18), Liqucelin -2Ml, Apheresis Three Way Stop Cock, Apheresis Acd Anticogulant Solution (500Ml)+Iso3826 Certified, Spectra Optia Machine Sdp Kit, Spectra Optia Machine Therapeutic Plasma Exchange Kit, Blood Transfusion Set Sterilized, Fistula Needle No.16 G, Medigrip (Non Staining Antiseptic Medicated Dressing With Spot Size 22Mm In Diameter). (Containing 0.5 Percent W/W Beenzalkonium Chloride, Tinted With Tatrazine Yellow) 100 Per Pack, Waffers For Tscd (Terumo Penpol ), Pack Size Should Be 140 Pieces Per Pack., Remi Deep Freeze Thermograph (-80) No W/+50 - 100, Thermo Scientific Deep Freeze (-40) -115/+50 (Reverse)5 Div 7 Day (C6282-169), Measuring Glass Cylinder -1000 Ml, Measuring Glass Cylinder - 500 Ml, Halogen Bulb For Microscope, Microcide Disinfectant Cat. No. 90071( Compatible With Biorad Fully Auto Analyser), Sodium Hypochlorite 4-6 Percent, Vaccutte Edta 2.0Ml Pac Of 100 Nos, Vaccutte Plain 2 Ml Pac Of 100 Nos, Sterilium / Sanitizer, Savlon, Adhesive Tape, Disposable Needle 22 G, Disposable Syringe 5 Ml, 3 Percent Reagent Red Blood Cells Panel For Abo Grouping (A1, A2, A1b, A2b, B, O) For Quality Controll Of Antisera, Pack Size Should Be Of 2 Ml Each, Company Should Provide Qc Report With Each Vial Supplied, Iso 13585, Bc Set Is Simple And Easy To Use. It Is A Safety-Engineered Design Protecting Healthcare Workers From Needle Stick Injury. And Now, Blood Collection Set Is Available With Pre-Attached Holder Blood Collection Set With Pre-Attached Holder 23G*¾*12” Blue Strictly Us Fda Approved & Ce Mark Germany, Bc Set Is Simple And Easy To Use. It Is A Safety-Engineered Design Protecting Healthcare Workers From Needle Stick Injury. And Now, Blood Collection Set Is Available With Pre-Attached Holder Blood Collection Set With Pre-Attached Holder 25G*¾*12” Orange Strictly Us Fda Approved & Ce Mark Germany, Bc Set Is Simple And Easy To Use. It Is A Safety-Engineered Design Protecting Healthcare Workers From Needle Stick Injury. And Now, Blood Collection Set Is Available With Pre-Attached Holder. Bloblood Collection Set With Pre-Attached Holder 21G*¾*12” Green Strictly Us Fda Approved & Ce Mark Germany, Containershave Special Dual-Lock System, With The Temporary Closure To Seal The Container For While, And Permanent Closure To Seal The Container Completely. It Gives You Great Flexibility In Disposable Sharps Treatment. Mi115 110*95*190 1L Strictly Us Fda Approved & Ce Mark Germany, Containershave Special Dual-Lock System, With The Temporary Closure To Seal The Container For While, And Permanent Closure To Seal The Container Completely. It Gives You Great Flexibility In Disposable Sharps Treatment. Mi156 210*155*345 7L Strictly Us Fda Approved & Ce Mark Germany, Containershave Special Dual-Lock System, With The Temporary Closure To Seal The Container For While, And Permanent Closure To Seal The Container Completely. It Gives You Great Flexibility In Disposable Sharps Treatment. Mi207 100*55*220 0.6L Strictly Us Fda Approved & Ce Mark Germany, Containershave Special Dual-Lock System, With The Temporary Closure To Seal The Container For While, And Permanent Closure To Seal The Container Completely. It Gives You Great Flexibility In Disposable Sharps Treatment. Mi235 110*95*270 1.4L Strictly Us Fda Approved & Ce Mark Germany, Containershave Special Dual-Lock System, With The Temporary Closure To Seal The Container For While, And Permanent Closure To Seal The Container Completely. It Gives You Great Flexibility In Disposable Sharps Treatment.Mi128 210*155*255 5L Strictly Us Fda Approved & Ce Mark Germany, Containershave Special Dual-Lock System, With The Temporary Closure To Seal The Container For While, And Permanent Closure To Seal The Container Completely. It Gives You Great Flexibility In Disposable Sharps Treatment.Mi218 352*352*660 40L Strictly Us Fda Approved & Ce Mark Germany, Ashpol, Liquid Detergent For Washing Glass Ware, Micropipette Variable Volume, Single Channel, 0010-0100Microlitre•Fully Autoclavable•Light Weight & Ergonomics Design For User Comfort•No Sharp Edges To Tear Gloveshsoft Touch Tip Ejection•Color D Volume Range For Easy Identification•Automatic Locking Of Set Volume•One Handed Operation For Safe Handling Of Potentially Infectious Materials•Super Blow Out Formicroorganisms Volume Pipetting.•Easy In Laboratory Recalibration & Maintenance.•Three Years Of Warranty, Micropipette Variable Volume, Single Channel, 0050 Microlitre•Fully Autoclavable•Light Weight & Ergonomics Design For User Comfort•No Sharp Edges To Tear Gloveshsoft Touch Tip Ejection•Color D Volume Range For Easy Identification•Automatic Locking Of Set Volume•One Handed Operation For Safe Handling Of Potentially Infectious Materials•Super Blow Out Formicroorganisms Volume Pipetting.•Easy In Laboratory Recalibration & Maintenance.•Three Years Of Warranty, Micropipette Variable Volume, Single Channel, 0040-00200 Microlitre•Fully Autoclavable•Light Weight & Ergonomics Design For User Comfort•No Sharp Edges To Tear Gloveshsoft Touch Tip Ejection•Color D Volume Range For Easy Identification•Automatic Locking Of Set Volume•One Handed Operation For Safe Handling Of Potentially Infectious Materials•Super Blow Out Formicroorganisms Volume Pipetting.•Easy In Laboratory Recalibration & Maintenance.•Three Years Of Warranty, Micropipette Variable Volume, Single Channel, 0200-1000 Microlitre•Fully Autoclavable•Light Weight & Ergonomics Design For User Comfort•No Sharp Edges To Tear Gloveshsoft Touch Tip Ejection•Color D Volume Range For Easy Identification•Automatic Locking Of Set Volume•One Handed Operation For Safe Handling Of Potentially Infectious Materials•Super Blow Out Formicroorganisms Volume Pipetting.•Easy In Laboratory Recalibration & Maintenance.•Three Years Of Warranty, Owrans Buffer 50Ml, Cuvette For Microlab Coagulometer, Thermal Printer Roll 57Mm For Cell Counter Print, Chart Recorder Pen, Bl Storage Freeze Graph (Haier) No.W/6/40-10, Platelet Agitator Thermograph (Penpol) No. 7 Day 0/40, Kit - Anti Hiv 1 & 2 Antibody Comb Test, Rapid Test 30 Minutes, Qualitative L Detection Of Igg Antibodies To Hiv 1 And 2 In Human Sera / Plasma, Use Of Synthetic Peptide As Antigens, Sensitivity 100 Percent, Specificity 100 Percent, Evaluated By Who, Pack Size 24 - 48 Tests, Kit - Anti Hiv 1 & 2 Antibody Flowthrough Test, Test To Be Finished Within 5 Min, Differntial Detection - Reactivity For Antibodies To Hiv Type 1 Or 2, Sensitivity 100 Percent & Specificity 99.7 Percent ,, Kit - Dbs Card Test Kit Rapid Kit, With All Accessories, 10 Tests Per Pack, For Hiv With All Accessories (White Cards - Disposable, As Per Number Of Tests, ), Harris Hematoxylene (Ready To Use ), Hemetoxylene Solution (Ready To Use ), Mgg Stain, Mountant Dpx Mountant Liquid, 500 Ml, Papanicolaou Stain Kit (Ready To Use) Pap Stain Kit, Scotts Wash Buffer (Ready To Use) For Pap Stain, Single Cytofunnel Tm, Cover Glass (22X50 Mm), Cover Glass (22X50 Mm) For Fnac, Horiba- Abx Basolyse Ii For Horiba Xlr 5-Part Hematology Cell Counter, Horiba- Abx Cleaner For Horiba Xlr 5-Part Hematology Cell Counter, Horiba- Abx Diluent For Horiba Xlr 5-Part Hematology Cell Counter, Horiba- Abx Eosinofix For Horiba Xlr 5-Part Hematology Cell Counter, Horiba- Abx Lysebio For Horiba Xlr 5-Part Hematology Cell Counter, Horiba- Abx Minoclair For Horiba Xlr 5-Part Hematology Cell Counter, Horiba- Abx Difftrol 3-Level Control Set ( L,N,H) For Horiba Xlr 5-Part Hematology Cell Counter, Horiba- Abx Minocal Calibrator For Horiba Xlr 5-Part Hematology Cell Counter, Horiba- Basolyse Ii Reagent For Horiba Pentra Xlr Hematology Analyser, Horiba- Cleaner Reagent For Horiba Pentra Xlr Hematology Analyser, Horiba- Diluent Reagent For Horiba Pentra Xlr Hematology Analyser, Horiba- Eosinofix Reagent For Horiba Pentra Xlr Hematology Analyser, Horiba- Lysebio Reagent For Horiba Pentra Xlr Hematology Analyser, Nihon- Cleanac-710 For Nihon Kohden 5-Part Hematology Cell Counter, Nihon- Cleanec-810 For Nihon Kohden 5-Part Hematology Cell Counter, Nihon- Hemolynac-310 (3N)Lyse For Nihon Kohden 5-Part Hematology Cell Counter, Nihon- Hemolynac-510 (5N) Lyse For Nihon Kohden 5-Part Hematology Cell Counter, Nihon- Isotonac-3 For Nihon Kohden 5-Part Hematology Cell Counter, Nihon- Mek 5D 3-Level Control Set (L,N,H) For Nihon Kohden 5-Part Hematology Cell Counter, Nihon- Mek - Cal, Calibrator For Nihon Kohden 5-Part Hematology Cell Counter, Nihon- Hemolynac-310 -Reagent For Compatible With Nihon Kohden Mek 9100 Hematology Analyser, Nihon- Hemolynac-510 - Reagent For Compatible With Nihon Kohden Mek 9100 Hematology Analyser, Nihon- Diluent -Reagent For Compatible With Nihon Kohden Mek 9100 Hematology Analyser, Stago- Sta Neoplastine For Prothrombin Time, Stago- Sta Liatest Ddi Plus D-Dimer Kit, Stago- Sta Liatest D-Dimer 2-Level Control (N+P) Kit, Stago- Sta System Control N + P Kit, Stago- Sta Coag Control N + P Kit, Stago- Sta Stirrer Red, Stago- Sta Stirrer White, Stago- Sta Owren Koller Kit - D-Dimer Diluting Fluid, Stago- Sta Cacl2 0.025 M Kit, Stago- Sta Cleaner Solution Kit, Stago- Sta Desorb U Kit, Stago- Sta Cooling Liquid, Stago- Sta Cuvette Roll ( Sta Compact/Sta Compact Max 3), Stago- Sta Liquid Fib, Stago- Sta Immunodef Viii, Stago- Sta Immunodef Ix, Stago- Sta Liatest Fdp, Stago- Sta Fdp Calibrator, Stago- Sta Fdp Control, Stago- Sta Unicalibrator, Stago- Fibrinogen 2,For Stago Max Coagulometer, Stago- Sta Thrombin Kit, Stago- Sta Deficient X, Stago- Sta Deficient Vii, Stago- Sta Deficient V, Stago- Sta Deficient Ii, Stago- Sta Immunodef Xii, Stago- Sta Staclot Heparin 1, Stago- Sta Stachrom At Iii 3, Stago- Sta Staclot Protein C, Stago- Sta Staclot Protein S, Stago- Stic Expert Hit 5, Stago- Stic Expert Hit 20, Stago- Thrombin Calibrator, Stago- Sta Hepanorm H, Stago- Sta Quality Hnf/Ufh, Stago- Sta Multihep Calibrator, Stago- Sta Neoptimal For Prothrombin Time, Stago- Sta D-Dimer Kit, Stago- Sta Cuvette Roll, Sysmex- Cellpack Dcl For Sysmex 7-Part Hematology Analyser, Sysmex- Sulpholyser -Sls For Sysmex 7-Part Hematology Analyser, Sysmex- Lysercell Wnr For Sysmex 7-Part Hematology Analyser, Sysmex- Lysercell Wdf For Sysmex 7-Part Hematology Analyser, Sysmex- Flurocell Wnr For Sysmex 7-Part Hematology Analyser, Sysmex- Flurocell Wdf For Sysmex 7-Part Hematology Analyser, Sysmex- Cellpack Dfl For Sysmex 7-Part Hematology Analyser, Sysmex- Flurocell Ret For Sysmex 7-Part Hematology Analyser, Sysmex- Flurocell Plt For Sysmex 7-Part Hematology Analyser, Sysmex- Cellclean For Sysmex 7-Part Hematology Analyser, Sysmex- Xn-Check 3-Level Control Set (L1, L2,L3) For Sysmex 7-Part Hematology Analyser, Sysmex- Xn-Check Calibrator For Sysmex 7-Part Hematology Analyser, Sysmex-Diluent (Cellpack Dcl) For Xn-1000 (7-Part Hematology Analyser), Sysmex- Sls-Sulpholyser For Xn-1000 (7-Part Hematology Analyser), Sysmex-Xn-1000 (7-Part Hematology Analyser) Reagent- Lysercell Wnr, Sysmex- Xn-1000 (7-Part Hematology Analyser) Reagent-Lysercell Wdf, Sysmex- Xn-1000 (7-Part Hematology Analyser) Reagent-Flurocell Wnr, Sysmex- Xn-1000 (7-Part Hematology Analyser) Reagent-Flurocell Wdf, Sysmex- 3-Level Control Set Xn Check (L1, L2,L3) For Xn-1000 7-Part Hematology Analyser, Hplc- Varient Ii Bts Kit ( 500 Test ) For Hplc Machine, Hplc- Hemoglobin A2 2-Level Control Set ( 1 & 2) For Hplc Machine, Hplc- Hba2 Detection Kit For Beta-Thalassemia Programme Variant Ii- Hplc, Flow- Attune Wash Solution, Flow- Attune Focusing Fluid, Flow- Attune Shutdown Solution, Flow- Attune Flow Cell Cleaning Solution, Flow- Performance Tracking Beads, Flow- Attune Debubble Solution, Flow- Attune 10X Rbc Lysing Buffer, Flow- Attune Flow Cytometry Staining Buffer, Flow- Ultracomp Ebeads™ Plus Compensation Beads, Flow- Intracellular Fixation & Permeabilization Buffer Set, Flow- 10X Rbc Lysis Buffer (Multi-Species, Flow- Countbright Tm Plus Absolute Counting Beads, 4 Micron, Flow- Id- Cd19 Monoclonal Antibody (Sj25c1), Pe-Cyanine7, Flow- Id-Cd10 Monoclonal Antibody (Ebiocb-Calla (Cb-Calla)), Pe,, Flow- Id-Cd34 Monoclonal Antibody (4H11), Apc, Flow- Id- Cd3 Monoclonal Antibody (Ucht1), Pe-Cyanine5,, Flow- Id- Cd13 Monoclonal Antibody (Wm-15 (Wm15)), Pe,, Flow- Id- Cd4 Monoclonal Antibody (Rpa-T4), Pe-Cyanine7,
|