Ourena Veronal Buffer 10 X 15 Ml For Automated Blood Coagulation Analyzer Sysmex Cn-3000 Dilution Buffer For Coagulation Samples. Sodium Barbital Content Is Not Less Than 0.028 Mol/L. Reagent Bottles: Barcoded. Release Form: Liquid, Ready For Use. Stability After Opening At Temperatures From +2 To + 8 ° C For At Least 8 Weeks. Packing: At Least 10 Bottles Of 15 Ml. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. Shelf Life: In Accordance With The Manufacturer’S Nd, At Least 60% Of The Shelf Life Declared By The Manufacturer At The Time Of Delivery., Screening Reagent La 10 X Per 2 Ml Lupus Anticoagulant For Automated Blood Coagulation Analyzer Sysmex Cn-3000 Reagent For The Simplified Drvvt Test For The Detection Of Lupus Anticoagulants. Reagent Bottles: Barcoded. Release Form: Lyophilisate. Stability After Opening At Temperatures From +2 To +8°C For At Least 2 Days. Stability After Freezing At -20°C For At Least 30 Days. Packing: At Least 200 Tests. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. Shelf Life: In Accordance With The Manufacturer’S Nd, At Least 60% Of The Shelf Life Declared By The Manufacturer At The Time Of Delivery., Standard Human Plasma For Calibration: Prothrombin Time (Pt); Fibrinogen (Clauss Method), Coagulation Factors Ii, V, Vii, Viii, Ix, X, Xi, Xii, Xiii And Von Willebrand Factor (Vwf), Inhibitors: Antithrombin Iii, Protein C, Protein S, Α2-Antiplasmin, C1 Inhibitor, Total Complement Activity, Plasminogen. Traceable To Who Reference Standard. Reagent Bottles: Barcoded. Release Form: Lyophilisate. Solvent: Distilled Water. Stability After Opening At Temperatures From +2 To +8°C For At Least 8 Hours. Stability After Freezing At -20°C For At Least 28 Days. Packing: At Least 10 Bottles Of 1 Ml Each. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. Shelf Life: In Accordance With The Manufacturer’S Nd, At Least 60% Of The Shelf Life Declared By The Manufacturer At The Time Of Delivery., Control Innovance D-Dimer 2 X 5 X 1 Ml. Norm And Pathology On Automated Blood Coagulation Analyzer Sysmex Cn-3000 Plasma For Intra-Laboratory Control Of The Test System For Assessing The Precision And Error Of Analysis In The Normal And Pathological Ranges In The Quantitative Determination Of D-Dimer. Reagent Bottles: Barcoded. Release Form: Lyophilisate. Solvent: Distilled Water. Stability After Opening At Temperatures From +2 To +8 ° C For At Least 7 Days. Stability After Freezing At -20 ° C For At Least 28 Days. Packing: The Number Of Low-Level Bottles In A Package Is At Least 5 Bottles Of 1 Ml, The Number Of High-Level Bottles In A Package Is At Least 5 Bottles Of 1 Ml. To Determine Compatibility With The Software Of Medical Equipment Available. From The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer. Upon Delivery, The Supplier Performs A Spectral Calibration Of The Kit. The Supplied Kit Must Be Compatible With The Version Of The Installed Software., Wash Buffer Cn-Coagwasher For Automated Blood Coagulation Analyzer Sysmex Cn-3000 The Washing Solution Is Intended For Washing The Automatic Coagulometer Analyzer Of The Cn Series After Performing The Analysis. Reagent Type: Detergent. Components: 1.0% Sodium Hypochlorite Solution (Active Chlorine Concentration). Stability After Opening 3 Months. Release Form: Ready-Made Solution. Physical Properties:1) Physical State And Color: Greenish-Yellow Liquid2) Odor: Slightly Pungent3) Ph ^ 11.1. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. Shelf Life: In Accordance With The Manufacturer’S Nd, At Least 60% Of The Shelf Life Declared By The Manufacturer At The Time Of Delivery., Ca Clean Ii Wash Solution 1 X 5000 Ml For Sysmex Cn-3000 Automated Blood Coagulation Analyzer Wash Solution Is Used To Wash The Reagent Tip. Reagent Type: Acid Detergent. Hydrogen Chloride Concentration Is Not More Than 0.2%. Concentration Of Nonionic Surfactants Is Not More Than 0.5%. Release Form: Ready-Made Solution. Stability After Opening (Closed Bottle): At Temperatures From 15 To 25°C - 1 Month. Packaging: 5000 Ml. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of Calibration On Standard Samples Approved By The Manufacturer, Supplier The Kit Is Spectral Calibrated Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. Shelf Life: In Accordance With The Manufacturer’S Nd, At Least 60% Of The Shelf Life Declared By The Manufacturer At The Time Of Delivery., Standard For Fibrinogen Level 1-6 6 X Per 1 Ml On Automated Blood Coagulation Analyzer Sysmex Cn-3000 Pooled Plasma Of Selected Healthy Donors, Which Is Used To Construct Standard Calibration Curves Intended For The Analysis Of Fibrinogen By The Clauss Method. Reagent Bottles: Barcoded. Release Form: Lyophilisate. Number Of Fibrinorgen Levels: At Least 6 Levels. Traceable To Who Reference Standard. Method For Confirming Fibrinogen Levels In Calibrators: Ratnoff And Menzie Method. Stability After Opening At Temperatures From +2 To +8°C For At Least 8 Hours. Stability After Freezing At -20°C For At Least 28 Days. Packing: At Least 6 Bottles Of 1 Ml. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. Shelf Life: In Accordance With The Manufacturer’S Nd, At Least 60% Of The Shelf Life Declared By The Manufacturer At The Time Of Delivery., Control Plasma Norm 10 X Per 1 Ml Per Automated Blood Coagulation Analyzer Sysmex Cn-3000Plasma For In-Laboratory Control Of The Test System For Determining The Following Analytes In The Normal Range: Prothrombin Time (Pt), Activated Partial Thromboplastin Time (Aptt), Thrombin Time (Tt), Batroxobin Time, Fibrinogen, Coagulation Factors Ii, V, Vii, Viii, Ix, X, Xi, Xii, Xiii And Von Willebrand Factor (Vwf), Antithrombin Iii, Protein C, Protein S, Α2-Antiplasmin, C1 Inhibitor, Total Complement Activity, Plasminogen, Lupus Anticoagulants. Traceable To Who Reference Standard. Reagent Bottles: Barcoded. Release Form: Lyophilisate. Solvent: Distilled Water. Stability After Opening At Temperatures From +2 To +8°C For At Least 8 Hours. Stability After Freezing At -20°C For At Least 28 Days. Packing: At Least 10 Bottles Of 1 Ml Each. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. Shelf Life: In Accordance With The Manufacturer’S Nd, At Least 60% Of The Shelf Life Declared By The Manufacturer At The Time Of Delivery., Reagent For Determination Of Innovance D-Dimer 1 Set 300 - Large On Automated Blood Coagulation Analyzer Sysmex Cn-3000 A Set Of Reagents For The Quantitative Determination Of Breakdown Products Of Cross-Linked Fibrin (D-Dimers) In Human Plasma, Intended For Use In Hemostasis Analyzers. The Linearity Of The Test Is Not Less Than 170-4400 Ng/Ml Fee. No Interference With Rheumatoid Factor At A Concentration Of At Least 1300 Units/Ml. Negative Predictive Value For Dvt/Pe Is Not Less Than 99.5%. Reagent Bottles: Barcoded. Release Form: Lyophilisate. Stability After Opening At Temperatures From +2 To +8°C For At Least 28 Days. Packing: At Least 360 Tests. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. Shelf Life: In Accordance With The Manufacturer’S Nd, At Least 60% Of The Shelf Life Declared By The Manufacturer At The Time Of Delivery., Reaction Cuvettes, Pack (3 X 1000 Pcs) For The Automated Blood Coagulation Analyzer Sysmex Cn-3000 Reaction Cuvettes For Photometric Detection Of The Reaction For The Automated Blood Coagulation Analyzer Sysmex Cn-3000. Material: Polystyrene. Packing: At Least 3000 Pcs. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. Shelf Life: In Accordance With The Manufacturer’S Nd, At Least 60% Of The Shelf Life Declared By The Manufacturer At The Time Of Delivery., Reagent For Determining Actin Fs 10 X 10 Ml (800 Tests) For Automated Blood Coagulation Analyzer Sysmex Sysmex Cn-3000 Reagent For Determining Aptt, Factors Viii, Ix, Xi, Xii, With Moderate Sensitivity To Lupus Anticoagulants And High Sensitivity To Heparin. Surface Activator: Ellagic Acid. Does Not Contain Components Of Animal Or Human Origin. Reagent Bottles: Barcoded. Release Form: Liquid, Ready For Use. Stability After Opening At Temperatures From +2 To + 8 ° C For At Least 14 Days. Packaging: At Least 800 Tests. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software., Reagent For The Determination Of Berichrom Antithrombin Iii Number Of Tests In A Set Of 30 Tests For The Automated Blood Coagulation Analyzer Sysmex Cn-3000 Reagent For The Quantitative Determination Of The Functional Activity Of Antithrombin Iii (At Iii) In Plasma Using Automatic Analyzers For The Diagnosis Of Limited Synthesis Of At Iii Or Increased Consumption, As Well As For Monitoring Replacement Therapy. Reagent Bottles: Barcoded. Release Form: Lyophilisate. The Sensitivity Limit Is No More Than 3.7%. Stability After Opening At Temperatures From +2 To +8°C For At Least 14 Days. Stability After Opening At -20°C For At Least 90 Days. Packaging: At Least 150 Tests. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. Shelf Life: In Accordance With The Manufacturer’S Nd, At Least 60% Of The Shelf Life Declared By The Manufacturer At The Time Of Delivery, Reagent For The Determination Of Protein C Berichrom Chromogenic 1 Set 30 Per Automated Blood Coagulation Analyzer Sysmex Cn-3000 Reagent For The Quantitative Determination Of The Functional Activity Of Protein C Using A Chromogenic Substrate As An Aid In The Diagnosis Of Congenital And Acquired Deficiency. Protein C Activator: Agkistrodon Contortrix Snake Venom Extract. Reagent Bottles: Barcoded. Release Form: Lyophilisate. Stability After Opening At Temperatures From +2 To +8°C For At Least 14 Days. Stability After Opening At -20°C For At Least 30 Days. Packing: At Least 200 Tests. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. Shelf Life: In Accordance With The Manufacturer’S Nd, At Least 60% Of The Shelf Life Declared By The Manufacturer At The Time Of Delivery., Reagent For Determining Thrombin Time 10 X Per 5 Ml 500 Tests For Automated Blood Coagulation Analyzer Sysmex Cn-3000 Reagent For Determining Thrombin Time In Human Plasma. Reagent Bottles: Barcoded. Release Form: Lyophilisate. Solvent: Distilled Water. Stability After Opening At Temperatures From +2 To +8°C For At Least 7 Days. Stability After Opening At -20°C For At Least 28 Days. Packaging: At Least 500 Tests. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. Shelf Life: In Accordance With The Manufacturer’S Nd, At Least 60% Of The Shelf Life Declared By The Manufacturer At The Time Of Delivery., Thrombin Reagent 100 I. U. 10 X For 5 Ml (Reagent For Determining Thrombin 100 I. U. 10 X Per 5 Ml) On Automated Blood Coagulation Analyzer Sysmex Cn-3000 Reagent For Determining Fibrinogen Using The Clauss Method In Plasma. Solvent: Distilled Water. The Thrombin Concentration In The Reagent Is At Least 100 Iu/Ml. Linearity Of The Test: No Longer 30 - 1400 Mg/Dl. Reagent Bottles: Barcoded. Release Form: Lyophilisate. Stability After Opening At A Temperature From +2 To +8 ° C For At Least 5 Days. Packaging: At Least 1000 Tests. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. Shelf Life: In Accordance With The Manufacturer’S Nd, At Least 60% Of The Shelf Life Declared By The Manufacturer At The Time Of Delivery., Confirming Reagent For La 2 10 X 1 Million Automated Blood Coagulation Analyzer Sysmex Cn-3000 Reagent For Drvvt With A High Content Of Phospholipids To Clarify Data On Lupus Anticoagulants. Reagent Bottles: Barcoded. Release Form: Lyophilisate. Stability After Opening At Temperatures From +2 To +8°C For At Least 2 Days. Stability After Freezing At -20°C For At Least 30 Days. Packing: At Least 100 Tests. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. Shelf Life: In Accordance With The Manufacturer’S Nd, At Least 60% Of The Shelf Life Declared By The Manufacturer At The Time Of Delivery., Calibrator Pt-Multi Calibrator 6 X 1 Ml For Automated Blood Coagulation Analyzer Sysmex Cn-3000 The Calibrator Kit Is Intended For Use As A Reagent For The Study Of Hemostasis. To Determine The Local Value Of Mich. Composition: Six Calibration Plasmas For Pv Calibration. Calibration Plasma Is Lyophilized And Calibrated. Stability After Reconstitution (Closed Vial): - At A Temperature Of 2-8 °C For 8 Hours; - At A Temperature Of 15-25 °C For 4 Hours; - At A Temperature ≤ −18 °C For 4 Weeks. Packaging 6X1 Ml. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. Shelf Life: In Accordance With The Manufacturer’S Nd, At Least 60% Of The Shelf Life Declared By The Manufacturer At The Time Of Delivery., Control Plasma Pathology 10 X Per 1 Ml On Automated Blood Coagulation Analyzer Sysmex Cn-3000Plasma For In-Laboratory Control Of The Test System For Determining The Following Analytes In The Pathological Range: Prothrombin Time (Pt), Activated Partial Thromboplastin Time (Aptt), Fibrinogen, Coagulation Factors Ii, V, Vii, Viii, Ix, X, Xi, Xii, Xiii And Von Willebrand Factor (Vwf), Antithrombin Iii, Protein C, Protein S, Α2-Antiplasmin, C1 Inhibitor, Total Complement Activity, Plasminogen. Traceable To Who Reference Standard. Reagent Bottles: Barcoded. Release Form: Lyophilisate. Solvent: Distilled Water. Stability After Opening At Temperatures From +2 To +8°C For At Least 8 Hours. Stability After Opening At -20°C For At Least 28 Days. Packaging: At Least 10 Vials Of 1 Ml. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. Shelf Life: In Accordance With The Manufacturer’S Nd, At Least 60% Of The Shelf Life Declared By The Manufacturer At The Time Of Delivery., Reagent For The Determination Of Thromborel S 10 X 4 Ml (400 Tests) For The Automated Blood Coagulation Analyzer Sysmex Cn-3000 Human Placental Thromboplastin For The Determination Of Pt, Inr, %, Factors Ii, V, Vii, X. Source Of Thromboplastin: Human Placenta. Insensitive To Heparin At A Concentration Of At Least 1.6 Units/Ml. Reagent Bottles: Barcoded. Release Form: Lyophilisate. Solvent: Distilled Water. Stability After Opening At Temperatures From +2 To +8°C For At Least 5 Days. Packaging: At Least 400 Tests. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. Shelf Life: In Accordance With The Manufacturer’S Nd, At Least 60% Of The Shelf Life Declared By The Manufacturer At The Time Of Delivery., Calcium Chloride 0.025 Mol/L 10 X 15 Ml Per Sysmex Cn-3000 Automated Blood Coagulation Analyzer Calcium Chloride Solution Is Used As An Additional Reagent For Various Blood Clotting Tests. Calcium Chloride Content: 0.025 Mol/L. Reagent Bottles: Barcoded. Release Form: Liquid, Ready For Use. Stability After Opening At Temperatures From +2 To +8°C For At Least 8 Weeks. Packing: At Least 10 Bottles Of 15 Ml Each. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. Shelf Life: In Accordance With The Manufacturer’S Nd, At Least 60% Of The Shelf Life Declared By The Manufacturer At The Time Of Delivery.
|