Tender For Design, Engineering, Manufacture, Survey, Supply, Transportation, Erection, Testing & Commissioning of 33kv PTR Bay, 11KV ID Switchgear and other Mislanious works at under construction Recieving station at Balakote Dharati on Turnkey Basis.” under the jurisdiction of Executive Engineer, Sub Transmission Division KALAKOTE, JPDCL Jammu -1 SITC of 3.15 MVA 33/11KV Power Transformer; ( EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 2 3.15 MVA 33/11kV, ONAN, Copper wound, Out-door Type, conventional Power Transformer, Oil Filled with OLTC and all accessories including HT and LT Terminal connections. 3 Providing & Fixing of Al Bus bars for transformer terminals of suitable size with color coding, heat shrinkable sleeves covered including drilling, welding etc as per requirement to be fixed on LV side of transformer as per relevant Standards 4 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 5 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 6 2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 7 33 kV Isolator With Earthing Blade with allied accessories and pad clamps (36kV,1250A, Outdoor, 3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.)For 33kv Line. 8 Installation of Capacitor Bank (INCLUDING ALL CIVIL WORKS & EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 9 11 KV Capacitor bank 1.2MVAR with VCB Panel and complete arrangement for connection with 11 KV incomer panel, Series Reactor, Isolator, RVT, Surge Arrestor, HT Cable with termination Kits, Control Cables, CRCA Cubicle Panel etc with Structure, foundation and accessories. 10 "33 kV TRANSFORMER BAY ( EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) " 11 33 KV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type) with allied accessories and heavy duty pad clamps. 12 33 kV Isolator with Without Earthing Blade with allied accessories and pad clamps (36kV,1250A, Outdoor, 3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.). 13 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) 14 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less (1 Set for Line & 2 Set for stn) 15 33 kV C&R Panel along with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Smart meter -5 Amps, DLMS Compliant with RS-485 port 16 33 kV Voltage Transformer (33 kV/110 V, 1Φ, Multi-Core, Outdoor), (1No. per Φ) 17 SITC OF CONTROL CABLES 18 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 19 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 20 2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 21 Lugs, Ferrules etc. 22 SITC OF CONDUCTOR & HARDWARE 23 Providing & Fixing 200 mm² ACSR Conductor Panther 24 Providing & Fixing of 630A T-clamps suitable for 0.2 ACSR Conductor having 8 no,'s GI bolts of 19mm thick, as per relevant Standards 25 Providing & Fixing of Aluminium Tention Fittings of 0.2 ACSR Conductor having 8 no,'s GI bolts of 19mm thick, as per Relevant Standards 26 Providing & Fixing Polymeric composite Disc Insulator 36KV, Lightening Impulse 170kV Positive and 180kV Negative, creepage distance 900mm,min failing load 70kN 27 Providing & Fixing of GI Earth wire 7/4.00 mm sq, with 4Nos. 13mtr long ST Poles for Shielding of 33KV Yard along with Power Transformer with proper earthing by GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm 28 Providing & Fixing of GI flat for earthing 50x6mm with epoxy insulator along with clamps as per relevant Standards 29 11 kV INDOOR SWITCHGEAR OF 6.3MVA, 33/11 KV SUBSTATION; (INCLUDING ALL CIVIL WORKS & EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 30 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, Outdoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Smart meter -5 Amps, (1+3)SET 31 11kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type (4/5/6 Sets) 32 11 kV 3- Core XLPE 300 mm² armoured, FRLS 33 11 kV 3-Core XLPE 120 mm² armoured, FRLS 34 11 kV Indoor Heat Shrinkable Cable Termination Kits 35 11 kV Outdoor Heat Shrinkable Cable Termination Kits 36 11 kV Indoor Heat Shrinkable Cable Termination Kits 37 11 kV Outdoor Heat Shrinkable Cable Termination Kits 38 11 kV Isolator, double break,3-pole, 600Amp, horizental mounting Type, with Earth Switch. 39 9 Mtr. Long Pole(ST-410 SP33) 40 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp 41 Galvanised iron of sorts including CH Angle brases Clamps etc. 42 100 KVA, 11/0.433 KV, 3-Phase Distribution Transformer with Bimetallic Terminal connectors Energy Level -2 (Alminium wound) 43 120 mm² PVC LT Cable 4 Core, armoured, FRLS 44 Cement bottoming 1:2:4 mix as per REC standards. 45 Earthing of 100 KVA Substation-Excavation of earht pit of dia 650 mm & depth 3000 mm installation of earthing pipe of 40 mm Nominal bore & 4 mm wall thickness & length 2.5 mtr long as per IS 1239 GI Strip[ for neutral earthing of size 75 mm x 10 mm & 50 mm x6 mm for connection of transformer body, G.O set & lightening arrestor as per IS 2629/85, GI Nuts & Bolts, refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover. 46 Supply ,Installation Testing and Commissioning of Earthing Complete by GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm. 47 11kV Bus Bar Fuse Set Out Door type for Auxilary Transformer 48 G.I Chainlink Fencing of 33kv Reciving station by way of mass concreting in foundations and chainlink fencing of 6 ft height using G.I Angle of size 65x65x6mm and G.I Flat iron 50x6mm including Main Gate 14feet*6feet complete job. 49 SITC of 120 Watts LED Street lights 6 Nos of following watts IP-66/67 protected with lens type LED, Pressure Di-cast aluminium body , 100+ LM/watt, Input voltage AC 85-265 Volts, efficacy 92%, life time more than 45000 Hrs. ( Crompton, Phillips, Jaguar, GE). To be mounted on 13mtr ST Pole 2 Nos including necessary boxes/fabrication/modification as per requirement. ( The LED lights brand must have conducted the indian photometic test certificate of LM-79 and 80.) 50 COMMON MISCELLANEOUS EQUIPMENTS 33/11kV SUBSTATIONS; (INCLUDING ALL CIVIL WORKS & EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 51 "a). Battery Bank 30 V,100 AH , of 15 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelene copolymer container,flame retardant. b). 30V,100 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply ." 52 Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Double busbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories 53 Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCB's (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories 54 Providing of Rubber Mat 1mx2m 19mm thick 55 Providing of Fire Extingiusher Co₂/ABC Type of 4.5 kg capacity for control room 56 Providing of 3 Sand Bucket Fire Extingiusher with metallic stand and identification plates 57 Providing of Industrial safety Helmet 58 Providing of Rubber Gloves for 33 kV level 59 Providing of Rubber Gloves for 11kV level 60 Providing of Tool Kit case plastic of Harry-kerry make of 2.5x1x1.5 feet dimensions with different chambers 61 "Providing of Clamp meter with multi measuring parameters Markoni/motwane/fluke make" 62 Providing of Screw driver tester neon lamp based 63 Providing of Aluminum industrial ladder split 40 feet extension type withallied accessories 64 Office Steel Chairs wih Armrest 65 Office Table of Standard Size with Sufficient Drawers 66 Office Almirah With Locker of reputed make 67 Cement Concrete R/B Wall as per site requirement, as per the direction of site Engineer. 68 SITC OF 11 kV LINE 69 9 Mtr. Long Pole( ST-410 SP15) 70 GI cross-arm with top Bracket including clamp 71 GI Braces and Belts including Clamps etc 72 50 mm² ACSR Conductor 73 PG Clamps for 50 mm² ACSR Conductor 74 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 75 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 76 Galvinized Nuts and Bolts 77 Danger Plates with Clamps 78 Anti-Climbing Device with Clamps 79 Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. 80 Red Oxide 81 Aluminium Paint 82 Cement bottoming 1:2:4 mix as per REC standards .45cum /pole 83 Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete 84 Sign Board for Receiving Station With JPDCL Logo.
|