Hygiene/Preventive Maintenance - General Cleaning Of Equipment; Checking Capacitors; Cleaning Air Filters; Compressor Check; Internal And External Cleaning Of Evaporators; Internal And External Cleaning Of Condensers; Cleaning The Evaporator Coils; Adjustment Of Thermostats; Air Flow Measurement; Checking The Electrical Panels For Overheating And Tightening The Terminals, Repairing Irregularities; Measure, Top Up And Replace The Refrigerant Gas Charge, General Lubrication Of Equipment; Checking For Abnormal Noises And Vibrations, Making The Necessary Adjustments And Corrections., Installation (Labor) Of An Air Conditioning Unit, Split Type, 9,000 And 12,000 Btus, Inverter Or Conventional, Including Labor And All Necessary Materials (Including Wires For Communication And Internal Power Supply Between Machines, Equivalent Piping, Insulation, Hose Drain, External Support And Finishing Tape), For Internal And External Installation, Including Circuit Breaker Installation And Wall Drilling. Installation Must Be Carried Out With At Least 3 M (Three) Of Pipe/Tubing Or In Accordance With The Device Manufacturers Specification., Installation (Labor) Of A Split-Type Air Conditioning Unit, From 18,000 To 24,000 Btus, Including Circuit Breaker Installation And Wall Drilling. The Installation Must Be Carried Out With A Minimum Of 2 M (Two) Of Pipe/Tubing Or In Accordance With The Device Manufacturers Specification. Of Air Conditioning Devices-Sms)Perp.Pdf, R22, R410 Or R32 Gas Refill For Equipment From 9,000 To 12,000 Btus (Checking And Replacing The Refrigerant Gas And Other Types Of Gases, In Order To Guarantee The Thermal Load Necessary For The Optimized Performance Of The Equipment, Including Testing Tightness)., R410 Or R32 For Equipment From 18,000 To 24,000 Btus (Check And Replace Refrigerant Gas And Other Types Of Gases, R410 Or R32 For Equipment From 33,000 Btus (Check And Replace Refrigerant Gas And Other Types Of Gases, Additional Installation Of Piping Per Meter (Tightness Pipe). Copper) 3/4 And 1/2, As Necessary, Either By Replacement As A Result Of Compromise Of The Aforementioned Material Due To Long Time Of Use, Or During Relocation (Exchange Of Place) Of Devices Already In Use, Or Even When The Installation Requires A Greater Extension Due To The Location In Which It Will Be Installed., Additional Installation Of Piping Per Meter (Copper Pipe) 3/8 And 5/8, Corrective Maintenance, Replacement Of Internal And External Plates In Split Type Air Conditioners 9,000 To 12,000 Btus, Invert Or Not, Including Functioning Test And Electronic Component Test, Internal And External Plate Change In Split Type Air Conditioners 18,000 To 33,000 Btus, Including Functional Test And Component Test Electronics., Exchange Of Capacitor, Relay And Sensors (Hot/Cold), 9,000, And 12,000 Invert Or Not, With Supply Of Parts And Components When Necessary Or Fault Detected, With Immediate Availability., Relay And Sensors Split Air Conditioning From 18,000 To 33,000 Btus Invert Or Not, With Supply Of Parts And Components When Necessary, Changing The 9,000 Btus Split Air Conditioning Turbine Inverter Or Not, With Immediate Availability, Changing The Air Conditioning Turbine
|