Cable Vvg 4*50. Main Characteristics: Number Of Cores: 4. Cross-Section: 50 Mm². Core Material: Copper. Rated Voltage: 0.66/1 Kv. Frequency: 50 Hz. Insulation/Shell: Pvc Plastic Compound (Low Flammability For Vvgng). Electrical Parameters: Permissible Current (In Air): ~155-167 A. Permissible Current (In Ground): ~173-187 A. Short-Circuit Current (1 Sec): ~5.23 Ka (5230 A). Core Resistance: 0.37-0.39 Ohm/Km. Design: Cores: Copper, Round Or Sector-Shaped, Class 1 Or 2. Filling: Pvc Plastic Or Chalk-Filled Rubber. Shell: Pvc Plastic Compound (For Vvgng - Non-Flammable). External Diameter: ~31-32 Mm. Operating Conditions (Vvgng): Operating Temperature: From -50°C To +50°C. Installation: Not Lower Than -15°C (Without Heating). Fire Hazard Class: P1b (For Vvgng). Service Life: At Least 30 Years., Frequency Converter 110 Kw. Specification: Power 110-132 Kw, Current, A 210 (G - Type) / 253 (P - Type), Input 3X380v, Output 3X380v, Number Of Discrete Inputs 5, Number Of Discrete Outputs 3, Number Of Analog Inputs 2 (0~10V/0~20Ma), Number Of Analog Outputs 2 (0~10V/0~20Ma). Built-In Communication Interfaces? Rs485 (Modbus Serial), Built-In Potentiometer Optional. Multi-Speed Control Mode, External Brake Control, Synchronization Function, Torque Synchronization. Application: General Industrial, Fan/Fume Exhaust, Pump, Crane Drive, Crusher, Mill, Conveyor, Extruder, Stirrer/Mixer, Feeder, Separator, Compressor, Screen. Shell Protection Degree, Ip 20, Operating Temperature, °C -10...+40, Control Panel With Digital Indicator (Removable), Overload Capacity 150% (G - Type) 60 Sec / 120% (P - Type) 60 Sec, Control Type Scalar (U/F), Open-Loop Vector Control, Closed-Loop Vector Control. Warranty For At Least 36 Months. Requirements For The Supplier: 1. The Supplier Must Connect The Frequency Converter To The Equipment, Configure It, Program It And Parameterize It, And Also Monitor Its Operation For At Least 3 (Three) Days. 2. In The Event Of Failure Of The Frequency Converter Before The Expiration Of The Warranty Period, The Supplier Is Obliged To Eliminate Defects In Operation At Its Own Expense, Within 5 (Five) Calendar Days. If It Is Impossible To Eliminate The Defects In The Work On Its Own, The Supplier Is Obliged To Reimburse The Costs Or Replace The Equipment. Before Delivery, Agree With The Customer., Control Cabinet For Pump With Frequency Converter, Power 110-132 Kw (According To Technical Specification), Control Cabinet For Pump With Frequency Converter, Power 200-220 Kw (According To Technical Specification)
|