Motion Sensor White Max Heat 1100W, Viewing Angle 120-360 Degrees Iec. Gost R 51324.2.1-99, Current Transformers T-0.66 1000/5. For Transmitting A Signal Of Measuring Information To Measuring Instruments In Alternating Current Installations With A Frequency Of 50 Or 60 Hz With A Rated Voltage Of Up To 0.66 Kv Inclusive. Technical Characteristics• Heat Resistance Of Insulating Materials: Class A • Nominal Safety Factor Of Devices: No More Than 10 Kb • Designed To Operate In The Following Conditions: • Temperature: From - 450С To + 400С • Humidity: 98% At 250C • Rated Primary Current: 1000 A • Rated Secondary Current: 5 A Version Single-Phase Current Transformer Accuracy Class (According To Eu Directive 2004/22/Ec (Mid)) 0.5S Certified Yes External Height 51 Mm Hole Diameter 62 Mm Hole Diameter 62 Mm Hole Height 51 Mm Number Of Secondary Windings 1 With Copper Bus No Rated Primary Current, A 1000 A Quick Pinning No Secondary Winding Connection Screw Connection Rated Secondary Apparent Power, Va 5 Va Rated Secondary Current, A 5 A With Protection Against Contact With Live Parts No Length 0.13 Width 0.12 Height 0.05 • Primary Verification No Earlier Than The 3Rd Quarter Of 2025, Registered With The State Survey Of The Republic Of Kazakhstan, Complies With The Current Gost, Standards Of The Republic Of Kazakhstan, Active Reactive Energy Meter, Multi-Tariff, Lcd, Power Profile, Event Log, Power Quality Parameters, Internal Power Interface, External Power, Rs-485, Infrared Port, Three-Phase 3~230/400V, 5(7.5) A, Multi-Tariff, Active And Reactive Energy, Class Accurate. [0.5S/1.0], Rs-485, Irda, Sensor Shunt, Lcd, On The Mounting Panel, Connection Via Transformers Accuracy Class 0.5S/1.0 Connection Interface Irda, Rs-485 Weight, Kg 1.5 Maximum Current (A) 7.5 Number Of Tariffs 4 Maximum Current For 10 Ms 30*I Number Of Phases 3 Calibration Interval 10 Years Rated Voltage 3×230/400 Service Life 3 Years Type Three-Phase Multi-Tariff Minimum Operating Temperature (°C) -45 Maximum Operating Temperature (°C) +55 Rated Current (A) 5 Overall Dimensions, Mm 170X74x258 The Meters Are Designed To Account For Active And Reactive Electrical Energy And Power In One Or Two Directions In Three-Phase 3- And 4-Wire Ac Networks With A Frequency Of 50 Hz Through Instrument Transformers With The Possibility Of Tariff Accounting By Day Zones, Accounting For Losses And Transmitting Measurements And Accumulated Information On Energy Consumption Via Digital Interface Channels And The Gsm Data Channel. Primary Verification No Earlier Than The 3Rd Quarter Of 2025, Registered With The State Inspectorate Of The Republic Of Kazakhstan. St Rk Gost 31818.11-2012 For General Requirements, St Rk Gost R 52322-2009 For Static Active Energy Meters, Current Transformers T-0.66 1500/5. For Transmitting A Signal Of Measuring Information To Measuring Instruments In Alternating Current Installations With A Frequency Of 50 Or 60 Hz With A Rated Voltage Of Up To 0.66 Kv Inclusive. Technical Characteristics• Heat Resistance Of Insulating Materials: Class A • Nominal Safety Factor Of Devices: No More Than 10 Kb • Designed To Operate In The Following Conditions: • Temperature: From - 450С To + 400С • Humidity: 98% At 250C • Rated Primary Current: 1500 A • Rated Secondary Current: 5 A Version Single-Phase Current Transformer Accuracy Class (According To Eu Directive 2004/22/Ec (Mid)) 0.5S Certified Yes External Height 51 Mm Hole Diameter 62 Mm Hole Diameter 62 Mm Hole Height 51 Mm Number Of Secondary Windings 1 With Copper Bus No Rated Primary Current, A 1500 A Quick Pinning No Secondary Winding Connection Screw Connection Rated Secondary Apparent Power, Va 5 Va Rated Secondary Current, A 5 A With Protection Against Contact With Live Parts No Length 0.13 Width 0.12 Height 0.05 • Primary Verification No Earlier Than The 3Rd Quarter Of 2025, Registered With The State Survey Of The Republic Of Kazakhstan, Complies With The Current Gost, Standards Of The Republic Of Kazakhstan
|