4.1 The Subject Of The Order Is The Maintenance Service Of Lighting Devices For Roads, Streets, Sidewalks, Parks And Sports Fields In The Wiązownica Commune, In Order To Keep Them In Proper Technical Condition. 4.2 The Scope Of The Subject Of The Order Includes Approximately 2,851 Lighting Points And 76 Control Systems Located In The Wiązownica Commune, Remaining On The Property Of The Wiązownica Commune. The Lighting Points On The Communes Property Are Located On Provincial, District And Commune Roads As Well As Public Squares In The Amount Of 2,654 Pcs, Orliki In The Amount Of 117 Pcs., In Cemeteries. In The Amount Of 18 Pieces And Sports Stadiums In The Amount Of 62 Pieces. The Following Street Lighting Devices Are Subject To Maintenance: - Power Supply For Power Supply And Control Cabinets, - Power Supply And Control Cabinets With Equipment, - Cable And Overhead Lighting Circuits, - Fixtures, Light Sources, Fuses, - Lighting Poles, - Booms, Lightning Arresters, Clamps, Grounding.4.3 The Scope Of Works Related To The Maintenance And Maintenance Of Lighting Includes: In Particular: 1) Monitoring Electricity Consumption In All Facilities, In Particular In Terms Of Ordered Power, Inductive Reactive Power And Capacitive Reactive Power; 2) Maintenance Of Street And Road Lighting, Lighting Of Squares, Parking Lots, Sports Fields, Sidewalks And Christmas Illuminations In The Wiązownica Commune; 3) Operation And Maintenance Of Overhead Networks Supplying Lighting Fixtures In Street Lighting Routes That Are Subject To Thermal Modernization, I.E. Replacement Of Existing Fixtures Lighting With New Led Fixtures; 4) Checking The Condition Of Visible Parts Of Cables, Their Connections, Lighting Poles And Accessories (Lighting Fixtures, Lighting Sources, Closures Of Recesses In Poles, Painted Surface Of Poles, Cleanliness Of Lamp Covers, Etc.); 5) Checking The Condition Of Safety, Control And Measurement Devices; 6) Inspection Of Lighting Fixtures Ignition Systems; 7) Carrying Out Measurements Of The Insulation Condition And The Effectiveness Of The Anti-Shock Protection, And Removing Any Defects Found During The Process; 8) Replacement Of Damaged Booms, Doors And Pole Fuse Boards; 9) Adjustment Of The Position Of Fixtures And Reflectors And Sagging Road Lighting Cables; 10) Repair Of Switchboards, Lighting Cabinets (Replacement Of Locks, Bolts, Doors) And Equipment (Clocks, Fuses, Switches, Contactors, Etc.); 11) Replacement, Renovation Of Cable And Overhead Lines And Location Of Their Damage; 12) Trimming Tree Branches That Cover Lighting Fixtures And Absorb Light Flux, As Well As Bringing Them Closer To Overhead Lines; 13) Control Of Lighting Switching On And Off Time; 14) Maintaining The Lighting Of All Light Fixtures At Set Times, In Relation To The Time Of Sunrise And Sunset; 15) Checking The Foundation And Restoring The Verticality Of Lighting Poles; 16) Painting And Maintenance Of Metal Structures Of Lanterns, Switchboards And Cabinets, As Well As Nu
|