0026284 - Portable Transport Lung Ventilator For Hospital Use, Intended For Ventilatory Support Of Adult And Pediatric Patients (From 5 Kg) In Intra- And Inter-Hospital Environments. The Equipment Must Be Powered By An Internal Rechargeable Battery With A Minimum Autonomy Of 6 Hours And A Bivolt Source (110V/220V), A High-Resolution Color Lcd Display For Continuous Monitoring Of Ventilation Parameters, And An Intuitive Interface For Operation. Mandatory Ventilation Modes Include: Volume Controlled Ventilation (Vcv), Pressure Controlled Ventilation (Pcv), Assisted/Controlled Ventilation (A/C) And Simv (Synchronized Intermittent Mandatory Ventilation). The Device Must Also Have Audible And Visual Alarms For Disconnection, Maximum Inspiratory Pressure, Low Battery And Airway Obstruction, In Addition To Being Constructed With Impact-Resistant Materials And Having An Integrated Transport System With Handle And Stable Support Base., 0026285 - Class C Vertical Autoclave, With A Capacity Of 21 Liters, Aimed At Instrument Sterilization Medical And Dental, Made Of Stainless Steel, Equipped With Fully Automatic Operation, With A Single Sterilization Program, 21 Safety Systems, Automatic Deaeration And Depressurization, Drying With A Half-Open Door, Automatic Bivolt Supply Voltage, Power Of 1600 W, External Dimensions Of 38 Cm (Width) X 38 Cm (Depth) (Ultrasonography) Wireless, Portable, Rechargeable, For Obtaining Medical Images In High Definition. It Must Bring Together, In A Single Transducer, Three Types Of Probes: One Of The Convex Type (Minimum Frequency Of 3.5 Mhz), One Of The Linear Type (Minimum Frequency Of 7.5 Mhz) And One Of The Sectoral Type (Cardiological Preset, With A Minimum Frequency Of 3, Switchable Via Software, Allowing Dynamic And Immediate Use Without Changing Devices. With Minimum Depth Of 20Mm (Linear), 90Mm (Convex And Sectorial). The Equipment Must Connect Directly To Mobile Devices, Such As Smartphones And Tablets, Compatible With Ios And Android Operating Systems, Through An Independent Internal Connection Via Wi-Fi (Ieee 802.11G Standard, 2.4 Ghz Band), Without The Need For Internet Or Cables. The Imaging Method Must Be Non-Invasive, Presenting Anatomy In Sectional Or Two-Dimensional Images, Which Can Be Acquired In Any Spatial Orientation. It Must Offer Images In Modes: B (Two-Dimensional), M (Motion), Color Doppler, Power Doppler (Pdi) And Spectral Doppler (Pw). Multiplatform.Must Have Measurement Functionalities In Convex And Linear Modules, Allowing General Calculations (Length, Area, Trace, Depth, Area Ratio, Circumference) And Obstetrics, Such As Ga (Crl), Ga (Bpd), Ga (Gs), Ga (Fl), Ga (Hc), Ga (Ac), Efw (Bpd) And Efw (Fl).The Equipment Must Be Powered By An Internal Rechargeable Battery With An Average Duration Of A Minimum Of 2 Hours In Continuous Use And A Minimum Of 4 Hours In Stand-By Mode.
|