Xn-L Check L3 (Control Blood Xn-Lcheck L3). The High Range (Level Three) Control Material Is Intended For Use As A Hematology Control Blood For Cbc, Wbc Differential, And Reticulocyte Parameters On The Sysmex Xn-L Series Instruments. The Use Of Stabilized Cell Preparations To Control Hematology Equipment Is A Common Procedure. Composition: Stabilized Human Erythrocytes, Leukocytes And Platelet Component In A Preservative Medium. Storage Conditions: Unopened Control Material Is Stored At 2-8°C Until The Expiration Date; After Opening, The Control Reagent Is Stable For 15 Days. Packaging: 1X3 Ml. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Test Material Supplied Must Be Compatible With The Version Of The Installed Software., Wash Solution Ca Clean Ii 1 X 500 Ml. Intended For Use As A Washing Reagent When Working On Clotting Factor Analyzers Composition: Hydrochloric Acid <1%; Ph=2.0. Stability After Opening (Closed Bottle): At Temperatures From 15 To 25°C - 1 Month. Packaging: 1X500 Ml. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software., Solutions: Cleaning Ca Clean I 1 X 50Ml. Intended For Use As A Washing Reagent When Working On Clotting Factor Analyzers. Composition: Sodium Hypochlorite 1.0% (Concentration Of Active Chlorine), Ph=11.5. Stability After Opening (Closed Bottle): At Temperatures From 2 To 8 ° C – 1 Month. Packaging: 1X50 Ml. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software., Control Plasma P 10 X For 1 Ml (Control Plasma P 10 X For 1 Ml). The Reagent Is Intended For Monitoring Coagulometer And Fibrinolysis Tests In Pathological Values. Composition: Lyophilized Pooled Plasma Of Selected Healthy Blood Donors, Stabilized With Hepes Buffer (12 G/L); Does Not Contain Preservatives. Packing: 10 X 1 Ml. Stability After Reconstitution At Temperatures From +15 To +25°C - 4 Hours. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software., Control Material C - Reactive Protein Low Level For Closed Type Biochemical Analyzer Bm 200. Cat. No. No. 1-811-0001, Control Serum In The Range With Pathological Values. 4 Lyophilized Vials For Dilution With 5 Ml Distilled Water For The Closed-Type Biochemical Analyzer Bm 200. Cat. No. 1-802-0020, Control Serum Is In The Normal Range. 4 Lyophilized Vials For Dilution With 5 Ml Distilled Water For The Closed-Type Biochemical Analyzer Bm 200. Cat. No. 1-801-0020, Multicalibrator Biocal For Closed-Type Biochemical Analyzer Bm 200. Cat. No. No. 1-803-0012. 4 Lyophilized Bottles For Dilution With 3 Ml Distilled Water, Reagent For Determination Calcium Concentration In Serum For The Closed-Type Biochemical Analyzer Bm 200. Cat. No. 1-413-A054. 180 Studies Per Pack, Reagent For Determination Magnesium For The Closed-Type Biochemical Analyzer Bm 200. Cat. No. No. 1-408-A054. 180 Studies Per Pack, Reagent For Determination Iron For The Closed-Type Biochemical Analyzer Bm 200. Cat. No. No. 1-420-A054. 216 Studies Per Pack
Contact Information
Contact Person
КУЛУШЕВА ГУЛНАР ЕРЕЖЕЕВНА
Address
710000000, 010000, Казахстан, г. Астана, ул. ПРОСПЕКТ РАКЫМЖАН КОШКАРБАЕВ, д. 64, оф.
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 107854302
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.