tender for annual miscellaneous civil maintenance works to be carried out at jalgaon zone office, jalgaon tq. & dist. jalgaon, 1 excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (lift upto 1.5 m.) 2 filling in plinth and floors with contractors material/brought from outside and approved by engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. 3 providing and laying cast in situ/ready mix cement concrete in m-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based plc with scada enabled reversible drum type mixer/concrete batch mix plant (pan mixer) etc. complete. with natural sand/v.s.i. quality artificial sand 4 removing lime or lean cement concrete including stacking the spoils as directed with all leads lifts, complete. spec. : as directed by engineer in charge. 5 providing and fixing in position tmt - fe - 500 bar reinforcement of various diameters for r.c.c. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 6 dismantling brick masonry in lime or cement mortar and stacking the materials as directed with all leads, lifts etc. 7 providing second class burnt brick masonry with conventional/ i.s. type bricks in cement mortar 1:6 in superstructure and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. complete. 8 providing second class burnt brick masonry with conventional/ i.s. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. complete. 9 providing second class burnt brick masonry with conventional/ i.s. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm x 1.6 mm placed at every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete. 10 providing external cement plaster 20mm thick in two coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. 11 providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 with neeru finish to concrete or brick surfaces, in all positions including scaffolding and
|