Tender for For Running Contract For Hon,Ble Sansad Nidhi/Vidhayak Nidhi And Other Deposit Works Under Edd-Budaun (Semi Turnkey).-- 1 The work of safe carriage of the following material from Navada Badaun store center to work siteunder the jurisdiction of LT/11 KV Vertical under EDDBADAUN . Approx. distance upto 30 Km. Including safe loading and unloading. 2 PCC Pole 8.5 meter long. 3 STP 11 Mtr Long 4 STP 13 Mtr Long 5 Line material i.e., cross arm/ pin insulator/stay/earthing rod/Ms Channel/MS Angle/Disc Fitting/Disc Insulators etc 6 11 KV XLPE Cable Size 3x70sqmm 7 11 KV XLPE Cable Size 3x120sqmm 8 11 KV XLPE Cable Size 3x185sqmm 9 11 KV XLPE Cable Size 3x300sqmm 10 ACSR Weasel Conductor 11 ACSR Rabbit Conductor 12 ACSR Raccon Conductor 13 ACSR Dog Conductor 14 3 Phase Arial Bunched Conductor 15 1 Phase Arial Bunched Conductor 16 Distribution Box 1 Phase 17 Distribution Box 3 Phase 18 11 KVCable Box Size 3x70sqmm 19 11 KV Cable Box Size 3x120sqmm 20 11 KV Cable Box Size 3x185sqmm 21 11 KV Cable Box Size 3x300sqmm 22 Straight Through 23 11/0.4 KV 3 Phase 25 KVA T/F 24 11/0.4 KV 3 Phase 63 KVA T/F 25 11/0.4 KV 3 Phase 100 KVA T/F 26 11/0.4 KV 3 Phase 250 KVA T/F 27 11/0.4 KV 3 Phase 400 KVA T/F 28 11 KV Pilfer proof Metering cubical and CT PT Unit 29 The Work of safe Carriage 11 KV O/G VCB store Center Nawada Budaunto work of site distance up to 0 to 30 km including safe loading & unloading. 30 Erection of new PCC Single/Double pole in H.T/L.T lines including fitting of all accessories as per RESSPO Norms 31 PCC Pole 8.5 Mtr Long Single Pole 32 PCC Pole 8.5 Mtr Long Double Pole 33 ST Pole 13 Mtr Long Single Pole. 34 ST Pole 13 Mtr Long Double Pole. 35 ST Pole 11 Mtr Long Single Pole. 36 ST Pole 11 Mtr Long Double Pole. 37 ST Pole 11 Mtr Long Tri Pole. 38 ST Pole 11 Mtr Long Four Pole. 39 Grouting with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/Concreate & sand Required as per RESSPO Norms 40 PCC Pole 8.5 Mtr Long Single Pole 41 PCC Pole 8.5 Mtr Long Double Pole 42 ST Pole 13 Mtr Long Single Pole. 43 ST Pole 13 Mtr Long Double Pole. 44 ST Pole 11 Mtr Long Single Pole. 45 ST Pole 11 Mtr Long Double Pole. 46 ST Pole 11 Mtr Long Tri Pole. 47 ST Pole 11 Mtr Long Four Pole. 48 Dismantling of PCC/ST Pole due to line shifting/damaged complete in all respect 49 ST Pole 9 Mtr Long Single Pole. 50 ST Pole 9 Mtr Long Double Pole. 51 ST Pole 11 Mtr Long Single Pole. 52 ST Pole 11 Mtr Long Double Pole. 53 ST Pole 11 Mtr Long Tri Pole. 54 ST Pole 11 Mtr Long Four Pole. 55 The work of Driving the earthing electrode and making connections with 6 S.W.G. GI wire as per RESSPO Norms 56 LT ABC (3x95+1x70+1x16) SQ. MM 57 LT ABC (3x120+1x95+1x16) SQ. MM 58 Dismantling of Old and damaged conductor complete in all respect 59 Dismantling of Existing Distribution Transformer for increasing capacity/Shifting complete in all respect 60 11/0.4 KV 3 Phase 25 KVA T/F 61 11/0.4 KV 3 Phase 63 KVA T/F 62 11/0.4 KV 3 Phase 100 KVA T/F 63 11/0.4 KV 3 Phase 250 KVA T/F 64 11/0.4 KV 3 Phase 400 KVA T/F 65 Laying, Stringing & Sagging of Following Conductor complete in all respect 66 ACSR Weasel Conductor 67 ACSR Rabbit Conductor 68 ACSR Raccon Conductor 69 ACSR Dog Conductor 70 3 Phase Arial Bunched Conductor 71 1 Phase Arial Bunched Conductor 72 Erection andfixing of Overhead Line By XLPE Cable Complete in all respect. 73 11 KV XLPE Cable Size 3x70 sqmm 74 11 KV XLPE Cable Size 3x120 sqmm 75 11 KV XLPE Cable Size 3x185 sqmm 76 After Mounting of CT PT unit on double pole, laying of 50 Mtr 11 KV 3cx70 sq mm cable in single circuit on river sand formDouble Pole to metering room complete in all respect. Alongwith filling of 04 nos cable jointing kits 77 Installation of 11 KV Pilfer Proof Metering Cubicle in metering room complete in all respect 78 Erection/Installation of following of VCB O/G in Consumers Site and Cable Joint of the panel to including earthing, grouting, Anchor bolt of panel of making/repairing of pocket for cable to insert in panel form trench and fixing taping of busbar with wiring for AC,DC Connection including providing AC and DC Supply. 79 Under ground laying of Following cable in Single circuit on river sand to Double pole situated at both sides of road complete in all respect. Minimum depth should be 0.75 Mtr and cable should be covered by bricks from three sides. Along with filling of 04 nos cable jointing kits 80 11 KV XLPE Cable Size 3x70 sqmm 81 11 KV XLPE Cable Size 3x120 sqmm 82 11 KV XLPE Cable Size 3x185 sqmm 83 11 KV XLPE Cable Size 3x300 sqmm 84 Under ground laying of Following cable in Single circuit by drill method to Double pole situated at both sides of NH/SH/Railway Crossing (with HDPE Pipe if required) complete in all respect. Alongwith filling of 04 nos cable jointing kits 85 11 KV XLPE Cable Size 3x70 sqmm 86 11 KV XLPE Cable Size 3x120 sqmm 87 11 KV XLPE Cable Size 3x185 sqmm 88 11 KV XLPE Cable Size 3x300 sqmm 89 Hoisting of Following size 11 KV & 33 KV XLPE Cableon double pole with GI pipe of size 6 " dia 4 Mtr long including the jumpering complete with clamps , nut and bolts 90 11 KV XLPE Cable Size 3x70 sqmm 91 11 KV XLPE Cable Size 3x120 sqmm 92 11 KV XLPE Cable Size 3x185 sqmm 93 11 KV XLPE Cable Size 3x300 sqmm 94 Supply & Laying of G.I. Pipe at various places i.e road crossing & Hoisting etc. complete in all respect (GI pipe would be Provided by contractor at his own cost) 95 Supply & Laying of HDPE Pipe at various places i.e road crossing & Hoisting etc. complete in all respect (HDPE pipe would be Provided by contractor at his own cost). 96 Chemical earthing of T/F& Fencingincluding all materials (chemical, gi pipe, gi strip, nut bolt, etc) 97 Earthing of distribution T/Ffor body & neutral upto water level with GI Pipe of 1.5" Dia. Including GI strip size 35x6 mm. (all material will be supplied by Contractor). 98 Construction of 250/400 KVA T/F plinth 2x2x1.5 Mtr. for mounting T/F including foundation work (below ground 0.5 M), Brick work, RCC slab of 4” thickness and plastering in 1:6 ratio with 02 Nos channel pieces of 1.5 mtr long of size 100x50x6 mm compete in all respect as per UPPCL Norms. 99 Cage fencing of 250/400 KVA Plinth mounted transformer in Town areas to avoid electrical human/cattle accidents by fabrication of cage (1 Inch Sq wire mesh) madeof 10 No gauge in suitable size angle iron frame of size 7.5'(L)x5'(W)x8'(H) by strengthening of wire mesh 20x3 mm M.S. flat horizontally as well as vertically, Grouting the panel with 1:2:4 cement/coorse send/brick ballast. The Frame should be bolted on angles at the four corners so that frame may be un-bolted/bolted at the time of replacement of the transformer. Provision of 1 gate should be there formaintenance of the transformer. Painting (1 coat of red oxide + 2 coat of Bus green enamel paint). The wire mesh should be earthed with 50x6 mm MS earthing strip with existing earthing of Transformer Body. All manpower, material and T&P provided by the contractor to complete the fabrication, transportation and installation. 100 The work of digging of pits, erection of Stay Clamp, Insulator etc. 101 Grouting of stays, 1:4:8 cc ratio (600x600x300mm.) as per RESPO norms. 102 Installation of 11 KV Pilfer Proof Metering Cubicle in metering room complete in all respect 103 Mounting of Following Capacity Transformers as per norms complete in all respect 104 25 KVA T/F 105 63 KVA T/F 106 100 KVA T/F 107 250 KVA T/F 108 400 KVA T/F 109 Fixing of Distribution Box complete in all respect 110 Guarding at road crossing complete in all respect 111 Errection & Fixing of Cable box 112 11 KVCable Box Size 3x70sqmm 113 11 KV Cable Box Size 3x120sqmm 114 11 KV Cable Box Size 3x185sqmm 115 11 KV Cable Box Size 3x300sqmm 116 Straight Through 11 KVCable Box Size 3x70sqmm,3X120sqmm,3x185sqmm) 117 Cutting of Tree Branch CommingNear Line 118 Supply & Fixing of Following Items to complete the work (If Not available in stores) 119 LT Clamps 120 Nut & Bolt off size 121 F Clampas per RESSPO Norms 122 Shackle Insulatoras per RESSPO Norms 123 X-Arm Holding Clampas per RESSPO Norms 124 clamps for top, t-off & other channel etc. 125 Stay Clampsas per RESSPO Norms 126 Three Phase Distribution Box Clamp (LS) 127 Dead End Clamp 128 Eye Hook 129 J Hook 130 LT Shackle Insulator 131 Barbed Wire 132 Aluminum Paint 133 Number Plate 134 Al. Lugs 70 Sqmm mm 135 Al. Lugs 150 Sqmm mm 136 Al. Lugs 240 Sqmm mm 137 Al. Lugs 400 Sqmm mm 138 11 KV DO Fuse Set 139 Garding Angle 140 Garding Angle Clamp with Nut & Bolt 141 Suspension Clamp for XLPE Overhead 142 Danger Board 143 Stone Pad 144 Dropper Channel 145 Safe back carriage of Distribution Transformer from work siteto Navada Store approx. distance upto 30 Km including safe loading & unloading. 146 A.B. Cable Scrap 147 Iron Scrap 148 STP Pole Scrap 149 ACSR Weasel Conductor Scrap 150 11/0.4 KV 3 Phase 25 KVA T/F 151 11/0.4 KV 3 Phase 63 KVA T/F 152 11/0.4 KV 3 Phase 100 KVA T/F 153 11/0.4 KV 3 Phase 250 KVA T/F 154 11/0.4 KV 3 Phase 400 KVA T/F 155 11 KV VCB 156 Note:-All Item Rate filling with GST by the firm
Contact Information
Contact Person
SE, EDC, BDN
Address
BUDAUN
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 107772850
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.