Cassette Cholesterol - Cholesterol (Chol) 2600 Tests. Reagents For The Cobas Pro (C 503) And Cobas Pure (C 303) Analyzers. Cholesterol Cassette Chol (Cholesterol) For 2600 Tests. Purpose: In Vitro Diagnostic Test For The Quantitative Determination Of Total Cholesterol In Human Serum And Plasma Using Cobas Analyzers. Reagents And Working Solutions: R Pipesa): 225 Mmol/L, Ph 6.8; Mg2+: 10 Mmol/L; Sodium Cholate: 0.6 Mmol/L; 4 Aminoantipyrine: ≥ 0.45 Mmol/L; Phenol ≥ 12.6 Mmol/L; Polyglycol Ether Of Fatty Alcohols: 3%; Cholesterol Esterase (Pseudomonas Spec.): ≥ 25 Μkat/L (≥ 1.5 U/Ml); Cholesterol Oxidase (E. Coli): ≥ 7.5 Μkat/L (≥ 0.45 U/Ml); Peroxidase (Horseradish): ≥ 12.5 Μkat/L (≥ 0.75 U/Ml); Stabilizers; Preservative A) Pipes = Piperazine-1,4-Bis(2-Ethanesulfonic Acid) Buffer Solution R Is In Position B. Storage And Transport Conditions: Store Refrigerated. Shelf Life At 2 8 °C See Expiration Date On The Cobas C Kit Label. When Used On Board The Analyzer At 10 15 °C 8 Weeks. Transport Must Be In Thermal Containers With Cold Packs At 2-8 °C, Do Not Expose To Freezing Or Exposure To High Temperatures. Calibration Is Linear At Two Points, Calibration Frequency Is After Changing The Lot. Measurement Range Is 0.1 20.7 Mmol/L (3.86 800 Mg/Dl). The Lower Detection Limit Of The Test Is 0.1 Mmol/L (3.86 Mg/Dl). Test Reproducibility Is No More Than 0.9%. Eu. If The Product Does Not Comply With The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification., Cassette Lactate Dehydrogenase - Lactate Dehydrogenase Acc. To Ifcc (Ldhi) 850 Tests. Reagents For The Cobas Pro/Pure Analyzer. Lactate Dehydrogenase Cassette For 850 Tests. Purpose An In Vitro Diagnostic Test Intended For The Quantitative Determination Of The Catalytic Activity Of Ldh (Ec 1.1.1.27; L‑Lactate: Nad+ Oxidoreductase) In Human Serum And Plasma On Cobas Integra Analyzers. Reagents - Working Solutions R1 N‑Methyl‑D‑Glucamine: 400 Mmol/L, Ph 9.4 (37 °C); Lithium Lactate: 62 Mmol/L; Stabilizers Sr Nbp: 62 Mmol/L; Stabilizers; Preservatives.Ready For Use.*Worn And Stable.Shelf Life At 2‑8°C See The Expiration Date On The Label Of The Cobas C Cassette. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Antistreptolysin Cassette - Antistreptolysin O (Aslo) 200 Tests. Reagents For The Cobas Pro/Pure Analyzer. Antistreptolysin Cassette For 200 Tests. Purpose: Kit For In Vitro Diagnostics. Designed For The Quantitative Determination Of Antibodies To Streptolysin O In Human Serum And Plasma On Roche/Hitachi Cobas C Analyzers. Reagents - Working Solutions R1 Tris Buffer: 170 Mmol/L, Ph 8.2 R2 Borate Buffer: 10 Mmol/L, Ph 8.2; Latex Particles Coated With Streptolysin O: 2 Ml/L. Preparation Of A Working Reagent Solution. Ready To Use. Before Installing The Cobas C Cassette On The Analyzer, Its Contents Must Be Mixed Thoroughly. Before Use, Carefully Invert The Reagent Cassette Several Times To Mix. Storage And Stability Shelf Life At 2‑8 °C: See Expiration Date On Cobas C Pack Cassette Packaging. Shelf Life Of The Opened Reagent In The Refrigerator On Board The Analyzer: 12 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Cassette Bilirubin Direct - Bilirubin Direct (Bild) 1000 Tests. Reagents For The Cobas Pro/Pure Analyzer. Direct Bilirubin Cassette For 1000 Tests. Purpose: In Vitro Test For Quantitative Determination Of The Concentration Of Direct Bilirubin In Human Serum And Plasma On Cobas C Systems. Reagents - Working Solutions: R1 Phosphoric Acid: 85 Mmol/L; Hedta: 4.0 Mmol/L; Nacl: 50 Mmol/L; Detergent; Ph 1.9 Sr 3.5‑Dichlorophenyl Diazonium: 1.5 Mmol/L; Ph 1.3. The Reagent Is Ready For Use. Storage And Stability: Shelf Life At 2‑8 °C See Expiration Date On Cobas C Cassette Label. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Reagents For The Cobas Pro/Pure Analyzer. Cassette For Determining Aspartate Aminotransferase For 800 Tests. Purpose In Vitro Diagnostic Test For The Quantitative Determination Of Aspartate Aminotransferase (Ast) In Human Serum And Plasma On Roche/Hitachi Cobas C Analyzers With Activation By Pyridoxal Phosphate. Reagents - Working Solutions R1 Tris Buffer: 264 Mmol/L, Ph 7.8 (37 °C); L Aspartate: 792 Mmol/L Mdh (Bacterial): ≥ 24 Μkat/L; Ldh (Bacterial): ≥ 48 Μkat/L; Albumin (Bovine): 0.25%; Preservative R2 Pyridoxal Phosphate: 730 Μmol/L; Preservative R3 Nadh (Yeast): ≥ 1.7 Mmol/L; 2 Oxoglutarate: 94 Mmol/L; Preservative Ready To Use Storage And Stability Astlp Shelf Life At 2 - 8 °C: See Expiration Date On Cobas C Pack Cassette Packaging. Shelf Life Of The Opened Reagent In The Refrigerator On Board The Analyzer: 12 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Cassette Alkaline Phosphatase - Alkaline Phosphatase Acc. To Ifcc (Alp) 1100 Tests. Reagents For The Cobas Pro/Pure Analyzer. Alkaline Phosphatase Cassette For 1100 Tests. Intended Use Of The In-Vitro Test For The Quantitative Determination Of Alkaline Phosphatase In Human Serum And Plasma On Roche/Hitachi Cobas C Analyzers. Reagents - Working Solutions R12‑Amino‑2‑Methyl‑1‑Propanol: 1.724 Mol/L, Ph 10.44 (30 °C); Magnesium Acetate: 3.83 Mmol/L; Zinc Sulfate: 0.766 Mmol/L; N‑(2‑Hydroxyethyl)‑Ethylenediaminetriacetic Acid: 3.83 Mmol/L R2 P‑Nitrophenyl Phosphate: 132.8 Mmol/L; Ph 8.50 (25 °C); Preservatives. Ready For Use. Storage And Stability Shelf Life At 2‑8 °C: See Expiry Date On Cobas C Pack Cassette Label. Shelf Life Of The Opened Reagent In The Refrigerator On Board The Analyzer: 8 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Albumin Cassette - Albumin (Alb) 750 Tests. Reagents For The Cobas Pro/Pure Analyzer. Albumin Cassette For 750 Tests. Purpose: Kit For In Vitro Diagnostics. Designed For The Quantitative Immunological Determination Of Human Albumin In Serum, Plasma, Urine And Csf. Applications For Urine And Csf Are Described In The Instructions For Tina‑Quant Albumin Gen.2 Urine Application And Tina‑Quant Albumin Gen.2 Csf Application. Reagents - Working Solutions R1 Trisa) Buffer: 50 Mmol/L, Ph 8.0; Peg: ≥ 4.2%; Edta: 2 Mmol/L; Preservative R2 Polyclonal Antibodies To Human Albumin (Sheep): Depending On Titer; Trisa) Buffer: 100 Mmol/L, Ph 7.2; Preservative Sr Reagent For Testing Excess Antigen. Albumin In Diluted Serum (Human); Phosphate Buffer: 50 Mmol/L, Ph 7.0; Preservative A) Tris = Tris(Hydroxymethyl)Aminomethane R1 Is In Position A, R2 Is In Position B, And Sr Is In Position C. Ready For Use. Storage And Stability. Shelf Life At 2‑8 °C See The Expiration Date On The Cobas C Cassette Label. When Stored On Board The Analyzer At 10-15 °C For 12 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., C-Reactive Protein (Crp) Cassette 500 Tests. Reagents For The Cobas Pro/Pure Analyzer. C-Reactive Protein Cassette For 500 Tests. Purpose: Immunoturbidimetric Test For Quantitative In Vitro Determination Of C‑Reactive Protein (Crp) In Human Serum And Plasma Using The Cobas System. Reagents - Working Solutions: R1 Buffer Solution Trisa) With Bovine Blood Serum Albumin; Preservatives Sr Latex Particles Coated With Anti‑Crp (Mouse) In Glycine Buffer; Immunoglobulins (Mice); Preservative The Reagent Is Ready For Use. Storage And Stability: Shelf Life At 2‑8°C See Expiry Date On Cobas C Cassette Label. When Used On Board The Analyzer At 10-15 °C 12 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Cassette Hemoglobin A1cx -Tina-Quant Hemoglobin A1cx 500 Tests. Reagents For The Cobas Pro/Pure Analyzer. Hemoglobin A1cx Cassette For 500 Tests. Purpose In Vitro Test For The Quantitative Determination Of Mmol/Mol Hemoglobin (Mfhc) And % Hemoglobin A1c (Icdo/Npsh) In Whole Blood Or Hemolysate On Roche/Hitachi Cobas C Systems. Definition Hba1c Concentration Is Useful For Long-Term Control Of Blood Glucose Levels In Patients With Diabetes Mellitus. Moreover, This Test Is Used As An Aid In The Diagnosis And Identification Of Patients At Risk Of Developing Diabetes. Reagents – Working Solutions - R1 Antibody Reagent Mes Buffer: 0.025 Mol/L; Tris Buffer: 0.015 Mol/L, Ph 6.2; Hba1c Antibody (Sheep Serum): ≥ 0.5 Mg/Ml; Detergents, Stabilizers; Preservatives R3 Polyhapten Reagent Mes Buffer: 0.025 Mol/L; Tris Buffer: 0.015 Mol/L, Ph 6.2; Hba1c Polyhapten: ≥ 8 M. The Reagent Is Ready For Use. Shelf Life At 2‑8 °C: See Expiration Date On Cobas C Cassette Label. Shelf Life Of The Opened Reagent In The Refrigerator On Board The Analyzer: 4 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Triglycerides Cassette (Trigl) 1000 Tests. Reagents For The Cobas Pro/Pure Analyzer. Triglyceride Cassette For 1000 Tests. Purpose - In Vitro Test For The Quantitative Determination Of Triglycerides In Human Serum And Plasma On Roche/Hitachi Cobas C Analyzers. Reagents - Working Solutions R1 Pipe Buffer: 50 Mmol/L, Ph 6.8; Mg2+: 40 Mmol/L; Sodium Cholate: 0.20 Mmol/L; Atp: ≥ 1.4 Mmol/L; 4‑Aminophenazone: ≥ 0.13 Mmol/L; 4‑Chlorophenol: 4.7 Mmol/L; Lipoprotein Lipase (Pseudomonas Spec.): ≥ 83 Μkat/L; Glycerokinase (Bacillus Stearothermophilus): ≥ 3 Μkat/L; Glycerol Phosphate Oxidase (E. Coli): ≥ 41 Μkat/L; Peroxidase (Horseradish): ≥ 1.6 Μkat/L; Preservative; Stabilizers R1 Is In Position B. The Reagent Is Ready For Use. Shelf Life At 2‑8 °C: See Expiration Date Expiration Date On The Cobas C Cassette Label. Shelf Life Of The Opened Reagent In The Refrigerator On Board The Analyzer: 8 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Iron Determination Cassette - Iron 700 Tests. Reagents For The Cobas Pro/Pure Analyzer. Iron Determination Cassette For 700 Tests. Purpose: Test For In Vitro Diagnostics. Designed For Quantitative Determination Of Iron In Human Serum And Plasma Using Cobas C Systems. Reagents - Working Solutions: R1 Citric Acid: 200 Mmol/L; Thiourea: 115 Mmol/L; Non-Reactive Surfactant Sr Sodium Ascorbate: 150 Mmol/L; Ferrozine: 6 Mmol/L; Preservative The Reagent Is Ready For Use. Storage And Stability: Shelf Life At 2‑8 °C See Cobas C Label For Expiry Date. When Stored On Board The Analyzer At 10-15 °C For 6 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Ldl Cholesterol Cassette - Ldl-Cholesterol (Ldlc) 600 Tests. Reagents For The Cobas Pro/Pure Analyzer. Ldl Cholesterol Cassette For 600 Tests. Purpose Test For In Vitro Diagnostics. Designed For The Quantitative Determination Of Ldl Cholesterol In Human Serum And Plasma Using Roche/Hitachi Cobas C Systems. Reagents - Working Solutions R1 Bis‑Trisb) Buffer: 20.1 Mmol/L, Ph 7.0; 4‑Aminoantipyrine: 0.98 Mmol/L; Ascorbate Oxidase (Aod, Acremonium Spec.): ≥ 66.7 Μkat/L; Peroxidase (Recombinant From Basidiomycetes): ≥ 166.7 Μkat/L; Bsa: 4.0 G/L; Preservative R2 Mopsc) Buffer: 20.1 Mmol/L, Ph 7.0; Emse: 2.16 Mmol/L; Cholesterol Esterase (Pseudomonas): ≥ 33.3 Μkat/L; Cholesterol Oxidase (Recombinant From E. Coli): ≥ 31.7 Μkat/L; Peroxidase (Recombinant From Basidiomycetes):≥ 333.3 Μkat/L; Bsa: 4.0 G/L; Detergents; Preservative The Reagent Is Ready For Use. Shelf Life At 2‑8°C: See Expiration Date On Cobas C Kit Label. Shelf Life Of Opened Reagent In The Refrigerator On Board The Analyzer: 12 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Hdl Cholesterol Cassette - Hdl-Cholesterol (Hdlc) 700 Tests. Reagents For The Cobas Pro/Pure Analyzer. Hdl Cholesterol Cassette For 700 Tests. Purpose In Vitro Test For The Quantitative Determination Of Hdl Cholesterol In Human Serum And Plasma On Roche/Hitachi Cobas C Analyzers. Reagents - Working Solutions R1 Tapsob) Buffer: 62.1 Mmol/L, Ph 7.77; Polyanion: 1.25 G/L; Emse: 1.08 Mmol/L; Ascorbate Oxidase (Pumpkin): ≥ 50 Μkat/L; Peroxidase (Horseradish): ≥ 166.7 Μkat/L; Detergent; Bsa: 2.0 G/L; Preservative R2 Bis-Trisc) Buffer: 20.1 Mmol/L, Ph 6.70; Cholesterol Esterase (Microorganism): ≥ 7.5 Μkat/L; Cholesterol Oxidase (Recombinant E. Coli): ≥ 7.17 Μkat/L; Cholesterol Oxidase (Microorganism): ≥ 76.7 Μkat/L; Peroxidase (Horseradish): ≥ 333 Μkat/L; 4‑Amino‑Antipyrine: 1.48 Mmol/L; Bsa: 3.0 G/L; Detergents; Canned Ready For Use. Shelf Life At 2‑8 °C: See Expiration Date On Cobas C Cassette Label. Shelf Life Of The Opened Reagent In The Refrigerator On Board The Analyzer: 12 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Cassette For Determination Of Uric Acid - Uric Acid (Ua) 1300 Tests. Reagents For The Cobas Pro/Pure Analyzer. Cassette Uric Acid Ua (Uric Acid) For 41,300 Tests. Purpose: In Vitro Diagnostic Kit. Designed For Quantitative Determination Of Uric Acid Concentration In Serum, Plasma And Urine. Reagents And Working Solutions: R1 Phosphate Buffer: 0.05 Mol/L, Ph 7.8; Toos: 7 Mmol/L; Fatty Alcohol Polyglycol Ether: 4.8%; Ascorbate Oxidase (Ec 1.10.3.3; Zucchini) ≥ 83.5 Μkat/L (25 °C); Stabilizers; Preservative Sr Phosphate Buffer: 0.1 Mol/L, Ph 7.8; Potassium Hexacyanoferrate (Ii): 0.3 Mmol/L; 4 Aminophenazone ≥ 3 Mmol/L; Uricase (Ec 1.7.3.3; Arthrobacter Protophormiae) ≥ 83.4 Μkat/L (25 °C); Peroxidase (Pod) (Ec 1.11.1.7; Horseradish) ≥ 50 Μkat/L (25 °C); Stabilizers; Preservative R1 Is In Position B, Sr Is In Position C. Storage And Transportation Conditions: Store In The Refrigerator. Shelf Life At 2 8 °C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10 - 15 °C 6 Weeks. Transportation Must Be In Thermal Containers With Cold Elements At A Temperature Of 2-8 °C, Do Not Expose To Freezing Or Exposure To High Temperatures. Calibration Is Linear At Two Points, Calibration Frequency Is After Changing The Lot. Measuring Range 11.9 1500 Μmol/L (0.20 25 Mg/Dl). The Lower Limit Of Detection Of The Test Is 11.9 Μmol/L (0.20 Mg/Dl). Test Reproducibility Is No More Than 1.8%. The Supplier Is Required To Provide A Certificate Of Origin Of The Goods. Delivery Area: For Eu Countries. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification., Phosphate Cassette - Phosphate (Inorganic) (Phos) 750 Tests. Reagents For The Cobas Pro/Pure Analyzer. Phosphate Cassette For 750 Tests. Purpose: Kit For In Vitro Diagnostics. Designed For The Quantitative Determination Of Phosphorus In Human Serum, Plasma And Urine On Roche/Hitachi Cobas C Analyzers. Reagents - Working Solutions R1 Sulfuric Acid: 0.36 Mol/L; Detergent R2 Ammonium Molybdate: 3.5 Mmol/L; Sulfuric Acid: 0.36 Mol/L; Sodium Chloride: 150 Mmol/L. Ready To Use. Storage And Stability. Shelf Life At 2‑8 °C: See Expiration Date On Cobas C Cassette Label. The Shelf Life Of The Opened Reagent In The Refrigerator On Board The Analyzer Is 12 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Cassette - Gamma-Glutamyltransferase - Gamma-Glutamyltransferase Standardized Against Ifcc/Szasz (Ggt) 400 Tests. Reagents For The Cobas Pro/Pure Analyzer. Cassette - Gamma-Glutamyltransferase For 400 Tests. Purpose In Vitro Diagnostic Test Intended For The Quantitative Determination Of The Catalytic Activity Of Ggtp (Ec 2.3.2.2; Γ-Glutamyl Peptide: Amino Acid Γ-Glutamyl Transferase) In Human Serum And Plasma On Cobas Integra Analyzers. Reagents - Working Solutions R1 Tris: 492 Mmol/L, Ph 8.25; Glycylglycine: 492 Mmol/L; Preservative; Additives Sr L‑Γ‑Glutamyl‑3‑Carboxy‑4‑Nitroanilide: 22.5 Mmol. Ready For Use. *Wound And Stability. Shelf Life At 2‑8 °C. Expiration Date See Label On Cobas C Cassette. Cobas Integra 400 Plus System In Case Of Injury On Board The Analyzer At 10‑15 °C 12 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Albumin Immunoturbidimetric Cassette Albt (Albumin Immunoturbidimetric) 500 Tests. Reagents For Cobas C311 Analyzer. Albumin In Urine Cassette For 100 Tests. Purpose: Kit For In Vitro Diagnostics. Designed For The Quantitative Immunological Determination Of Human Albumin In Serum, Plasma, Urine And Csf. Reagents - Working Solutions: R1 Trisa) Buffer: 50 Mmol/L, Ph 8.0; Peg: ≥ 4.2%; Edta: 2 Mmol/L; Preservative R2 Polyclonal Anti-Human Antibodies Albumin (Sheep): Various Titers; Trisa) Buffer: 100 Mmol/L, Ph 7.2; Preservative Sr Reagent For Testing Excess Antigen Albumin In Diluted Serum (Human); Phosphate Buffer: 50 Mmol/L, Ph 7.0; Preservative A) Tris = Tris(Hydroxymethyl)-Aminomethane R1 Is In Position A, R2 Is In Position B, And Sr Is In Position C. Storage And Transportation Conditions: Store Refrigerated. Shelf Life At 2‑8 °C See When Used On Board The Analyzer At 10‑15 °C 12 Weeks. Transportation Must Be In Thermal Containers With Cold Elements At A Temperature Of 2-8 °C, Do Not Expose To Freezing Or Exposure To High Temperatures. Linear Calibration At Six Points With Automatic Dilution, Calibration Frequency - After Changing The Lot. The Lower Detection Limit Of The Test Is 18 Mg/L (0.274 Μmol/L Or 1.8 Mg/Dl). Test Reproducibility Is No More Than 0.9%. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods, The Deadline For Replacing Low-Quality And Non-Conforming Goods: Within 3 Working Days. When Delivering The Goods, The Presence Of A Representative Of The Supplier Is Mandatory., Urea Cassette - Urea/Bun (Ureal) 600 Tests. Reagents For The Cobas Pro/Pure Analyzer. Reagents For The Cobas Pro/Pure Analyzer. Urea Cassette For 600 Tests. Purpose: Test For In Vitro Diagnostics. Designed For Quantitative Determination Of The Concentration Of Urea/Bun (Blood Urea Nitrogen) In Serum And Blood Plasma And In Human Urine Using Cobas C Analyzers. Reagents - Working Solutions: R1 Tris Buffer: 220 Mmol/L; 2‑Oxoglutarate: 73 Mmol/L; Nadh: 2.5 Mmol/L; Adp: 6.5 Mmol/L; Urease (Canavalia Xiphoid): ≥ 300 Μkat/L; Gldh (Bovine): ≥ 80 Μkat/L; Stabilizers; Ph 8.6. The Reagent Is Ready For Use. Storage And Stability: Shelf Life At 2‑8 °C See The Expiration Date On The Cobas C Cassette Label. When Stored On Board The Analyzer At 10-15 °C For 8 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Glucose Cassette - Glucose Hk (Gluc Nk) 3300 Tests. Reagents For The Cobas Pro/Pure Analyzer. Glucose Cassette For 3300 Tests. Purpose: In Vitro Diagnostic Test Intended For The Quantitative Determination Of Glucose In Serum, Plasma, Urine And Cerebrospinal Fluid On Cobas C Analyzers. Reagents - Working Solutions: R1 Morpholinoethanesulfonic Acid Buffer (Mes): 5.0 Mmol/L, Ph 6.0; Mg2+: 24 Mmol/L; Atp: ≥ 4.5 Mmol/L; Nadp+ : ≥ 7.0 Mmol/L Sr Hepes Buffer: 200 Mmol/L, Ph 8.0; Mg2+: 4 Mmol/L; Ha (Yeast): ≥ 300 Μkat/L; G6pdh (Bacterial): ≥ 300 Μkat/L. Storage And Stability: Shelf Life At 2‑8 °C See Expiration Date On Cobas C Cassette Label. When Used On Board At 10‑15 °C 8 Weeks If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Cassette For Determining Unsaturated Iron-Binding Capacity - Unsaturated Ironbinding Capacity (Uibs) 100 Tests. Reagents For The Cobas Pro/Pure Analyzer. Cassette For Determining Unsaturated Iron-Binding Capacity For 100 Tests. Purpose: In Vitro Test For Quantitative Determination Of The Unsaturated Iron-Binding Capacity Of Human Blood Serum And Plasma. Reagents And Working Solutions: R1 Ferric Chloride: 62 Μmol/L; Sodium Bicarbonate: 75 Mmol/L; Tris Buffer: 375 Mmol/L, Ph 8.4; Preservative R3 Ferrozine: 20 Mmol/L; Hydroxylamine: 160 Mmol/L, Ph 2.5 R1 Is At Position A And R3 Is At Position C. Position B Contains H2o For Technical Reasons. Storage And Transportation Conditions: Store In The Refrigerator. Shelf Life At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On-Board The Analyzer At 10-15°C 8 Weeks. Transportation Must Be In Thermal Containers With Cold Elements At A Temperature Of 2-8 °C, Do Not Expose To Freezing Or Exposure To High Temperatures. Calibration Is Linear At Two Points, Calibration Frequency Is After Changing The Lot. Measuring Range 6.0‑125 Μmol/L (33.5‑700 Μg/Dl). The Lower Detection Limit Of The Test Is 6.0 Μmol/L (33.5 Μg/Dl). Test Reproducibility Is No More Than 0.8%. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification., Alanine Aminotransferase Cassette - Alanine Aminotransferase Acc. To Ifcc Ii (Altp2) 800 Tests. Reagents For The Cobas Pro/Pure Analyzer. Alanine Aminotransferase Cassette For 800 Tests. Purpose In Vitro Test For The Quantitative Determination Of Alanine Aminotransferase (Alt) With Pyridoxal Phosphate Activation In Human Serum And Plasma In Roche/Hitachi Cobas C Systems. Reagents - Working Solutions R1 Tris Buffer: 224 Mmol/L, Ph 7.3 (37 °C); L Alanine: 1120 Mmol/L; Albumin (Bovine): 0.25%; Lactate Hydrogenase (Bacterial): ≥ 45 Μkat/L; Stabilizers; Preservative R2 Pyridoxal Phosphate: 730 Μmol/L; Additives; Preservative R3 2 Oxoglutarate: 94 Mmol/L; Nadh: ≥ 1.7 Mmol/L; Additives; Preservative Ready To Use Storage And Stability Altlp Shelf Life At 2 - 8 °C: See Expiration Date On Cobas C Cassette Label Shelf Life Of Opened Reagent In The Refrigerator On Board The Analyzer: 12 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Cassette Total Protein (Tp) 1050 Tests. Reagents For The Cobas Pro/Pure Analyzer. Total Protein Cassette For 1050 Tests. Purpose: Test For In Vitro Diagnostics. Designed For Quantitative Determination Of Total Protein Concentration In Serum And Plasma Using Cobas C Systems. Reagents - Working Solutions: R1 Sodium Hydroxide: 400 Mmol/L; Sodium Potassium Tartrate: 89 Mmol/L; Ph: 13.4 Sr Sodium Hydroxide: 400 Mmol/L; Sodium Potassium Tartrate: 89 Mmol/L; Potassium Iodide: 61 Mmol/L; Copper Sulfate: 24.3 Mmol/L; Ph: 13.2. The Reagent Is Ready For Use. Storage And Stability: Shelf Life At 15‑25 °C See Expiry Date On Cobas C Cassette Label. When Used On Board The Analyzer At 10‑15 °C 4 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Alpha Amylase Cassette - Alpha-Amylase Eps (Amyl) 750 Tests. Reagents For The Cobas Pro/Pure Analyzer. Alpha Amylase Cassette For 750 Test G. Purpose: Test For In Vitro Diagnostics. Designed For The Quantitative Determination Of The Catalytic Activity Of Α‑Amylase (1,4‑Α‑D‑Glucan: Glucanohydrolase; Ec 3.2.1.1) In Human Serum And Plasma, As Well As Urine On Cobas C Systems. Reagents - Working Solutions: R1 Hepes: 52.4 Mmol/L; Sodium Chloride: 87 Mmol/L; Calcium Chloride: 0.08 Mmol/L; Magnesium Chloride: 12.6 Mmol/L; Α‑Glucosidase (Microbial): ≥ 66.8 Μkat/L; Ph 7.0 (37 °C); Detergent; Stabilizers Sr Hepes: 52.4 Mmol/L; Ethylidene-G7-Pnp: 22 Mmol/L; Ph 7.0 (37 °C); Detergent; Stabilizers. The Reagent Is Ready For Use. Storage And Stability: Expiration Date At 2‑8 °C See The Expiration Date On The Cobas C Cassette Label. When Stored On Board The Analyzer At 10-15 °C For 12 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Cassette Bilirubin Total - Bilirubin Total (Bilt) 1050 Tests. Reagents For The Cobas Pro/Pure Analyzer. Bilirubin Cassette General For 1050 Tests. Purpose: In Vitro Test For The Quantitative Determination Of Total Bilirubin Content In Human Serum And Plasma (Adults And Newborns) On Cobas C Analyzers. Reagents - Working Solutions: R1 Phosphate: 50 Mmol/L; Detergents; Stabilizers; Ph 1.0 Sr 3.5‑Dichlorophenyl Diazonium Salt: ≥ 1.35 Mmol/L. The Reagent Is Ready For Use. Storage And Stability: Shelf Life At 2‑8 °C See Expiration Date On Cobas C Cassette Label. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Creatinine Jaffe Cassette (Crej) 2500 Tests. Reagents For The Cobas Pro/Pure Analyzer. Creatinine Jaffe Cassette For 2500 Tests. Purpose: In Vitro Diagnostic Test Intended For The Quantitative Determination Of Creatinine In Urine On Cobas C Analyzers. Reagents - Working Solutions: R1 Potassium Hydroxide: 900 Mmol/L; Phosphate: 135 Mmol/L; Ph ≥ 13.5 Sr Picric Acid: 38 Mmol/L; Ph 6.5; Non-Reactive Buffer. The Reagent Is Ready For Use. Storage And Stability: Shelf Life At 15‑25 °C See Expiration Date Expiration Date On The Label Of The Cobas C Cassette. When Used On Board At 10‑15°C 8 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Cassette For Determining Rheumatoid Factor (Rf-Ii) 400 Tests. Reagents For The Cobas Pro/Pure Analyzer. Cassette For Determining Rheumatoid Factor For 400 Tests. Purpose Kit For In Vitro Diagnostics. Designed For The Quantitative Determination Of Rheumatoid Factor (Rf‑Ii) In Human Serum And Plasma On Roche/Hitachi Cobas C Analyzers. Measurements Can Be Used As An Aid In The Diagnosis Of Rheumatoid Arthritis. Reagents - Working Solutions R1 Glycine Buffer: 170 Mmol/L, Ph 8.0; Polyethylene Glycol: 0.05%; Bovine Serum Albumin; Stabilizer; Preservative R2 Latex Particles Coated With Human Igg; Glycine Buffer Solution: 170 Mmol/L, Ph 7.3; Stabilizers, Preservatives R1 Is In Position B, R2 Is In Position C. The Reagent Is Ready For Use. Storage And Stability Rf‑Ii Shelf Life At 2‑8 °C: See Expiration Date On The Cobas C Cassette Label. Shelf Life Of The Opened Reagent In The Refrigerator On Board The Analyzer: 8 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database.
|