|
Chemical, Individual And Portable Toilet Of At Least 1M Wide Complying With All Relevant Legal Provisions Included In The Item, Individual And Portable, For Users Of Wheelchairs With Standard Dimensions That Allow The Movement Of The Users Wheelchair Within The Bathroom, Comprising All Equipment And Safety Accessories That Meet The Requirements Set Out In Technical Standards Approved By The Competent Bodies, Collection And Disposal Of Waste With Vehicle Suitable For Transport Complying With All Relevant Legal Determinations Included In The Item., Dressing Room With Lined Roof Built With Ts Plates Measuring 3Mx5m With 2 Access Doors (1 For Regular Entrance And Another Internal For The Service Dressing Room), With Level Deck Flooring And Lining Mat, 1 New And Recently Sanitized Air Conditioning Unit And Furniture, Including 1 Full-Length Mirror, 1 Microwave, Tables For Assembling The Dressing Room, Makeup Counter With Mirror, 1 Sofa With Three Seats, 5 Chairs, Refrigerator To Cool Drinks, Trash Can, 1 Large Table With White Tablecloth, 1 Free Table, Sockets (220V) And Face Towels. Assembly And Disassembly Included In The Item, Dressing Room With Lined Ceiling Built With Ts Plates Measuring 4Mx5m With 1 Access Door, 20 Chairs, Dressing Room With Lined Ceiling Built With Ts Plates Measuring 4Mx5m With 2 Access Doors (1 For Regular Entrance And Another Internal For The Service Dressing Room), 01/16/2026 - 11:26:42, Set Of Two Pavilions, Measuring 15M (Width) X 35M (Length) Each, Structured In Galvanized Steel Profiles, With A Minimum Ceiling Height Of 3M. The Pavilions Must Have A Central Gutter Between The Structures, A White Canvas Cover With A Flammability Certificate And An L-Shaped Canvas Side Closure. Assembly And Disassembly Are Included In The Item. The Fixing Must Be Carried Out Using Water Tanks (The Responsibility Of The Contractor), And Under Each Foot Of The Structure A Plywood Board With A Minimum Thickness Of 10 Mm Must Be Positioned, Electronic Crowd Metering Equipment, With High-Precision Sensor Technology. The System Must Have, At A Minimum, The Following Features: Automatic Counting Of Entry And Exit Of People, With Real-Time Display, Digital Panel Or Electronic Device For Immediate Visualization Of The Number Of People Present, Capacity For Continuous Operation Throughout The Entire Period Of The Event, Bivolt Power Supply (110/220V) Or Rechargeable Battery System, Metal Closure For Events, In Linear Modules, With A Minimum Height Of 2.00 M, Made Of An Iron Structure In Excellent Condition, Suitable For Delimiting Areas And Access Control At Events. The Material Must Present Good Mechanical Resistance And Structural Stability, Protection Grids With Pieces Measuring At Least 1.20M High By 2M Long. Assembly And Disassembly Included In The Item., Covered Pavilion In Two-Story Format With A Minimum Of 2,600M², Measuring 40M(L) By 65M(L), Ceiling Height With A Minimum Height Of 8M In The Central Module, And Ceiling Height With A Minimum Height Of 4.5M On The External Side Of The Flaps; The 20M X 65M Central Module Must Be Free-Span, Plus Two Later Modules
|