Group 01 - Reagents .. Specification: Group 01 - Reagents Uric Acid 6,000 / Amylase Cnpg 4,500 / Albumin 10,000 / Total Bilirubin 7,800 / Direct Bilirubin 7,800 / Calcium Arsenazo 7500 / Cknac 3,000 / Ckmb / Tgp 120 Ml 10,000 / Triglycerides 200 Ml 33,320/ Urea Uv 500 Ml 15,000 / Lipase 48 Ml 2,880 / Magnesium 15,000 / Ionic Sodium (Ise) 9,000/ Ionic Potassium (Ise) 9,000/ Chlorine Ionico (Ise) 9,000 / Iron 100 Ml 10,000. For Group 01, The Company Will Be Required To Provide On A Loan Basis (At No Additional Cost) An Analyzer In Accordance With The Minimum Characteristics Below: Minimum Specifications: 01 (One) Fully Automated Multi-Parameter Analyzer With A Capacity Of Greater Than 420 Tests Per Hour With A Minimum Of 240 Photometric Tests Per Hour + 180 Ise Tests Per Hour With A Continuous Refrigerated Tray In Order To Maintain The Stability Of The Reagents On Board; You Must Provide Distilled/Deionized Water Or Equipment With A Reverse Osmosis System To Produce Adequate Water For The Use Of The Equipment; Tray With A Capacity Of More Than 29 Different Reagents, With A Volume Between 30 And 55 ?L; Sample Tray With Capacity Of More Than 58 Samples For Primary Tubes Or Cuvettes For Low Volume Samples (Pediatric Samples); Minimum Sample Volume Of 2 ?L With Capacity For Identification By Barcode Or Position; Emergency Samples (Stat), Even With The Routine In Progress; The Equipment Must Be Capable Of Performing Automatic Dilution Of Samples; Equipment Must Carry Out End-Point And Kinetic Reactions With A Minimum Reaction Volume Of 230?L; Automatic Quality Check Of Reaction Cells; Automatic Probe Washing (Internal And External) With The Possibility Of Extra Washing Between Tests; Pre-Heating Of Samples And Reagents At 37C; It Must Have A Level Detector For Solutions, Group 02 - Reagents For Hemogram. Rdw-Sd, Plt, Pct, Mpv, Pdw, P-Lcr, P-Lcc, Ne#, Ne%, Ly#, Ly%, Mo#, Mo%, Eo#, Eo%, Ba#, Ba%, Blast#, Blast%, Nrbc#, Nrbc%, Alm#, Alm%, Imm#, Imm%, Left#, Left%. ?Have Touch-Screen Display And Store Results. ?Use Laser And Flow Cytometry. Speed Of At Least 60 Samples / Hour. ?It Must Accept An Open Or Closed Primary Vacuum Tube With Automatic Perforation Of The Cap For Aspiration Of The Blood Sample Without Requiring The User To Uncap The Tube, Thus Avoiding Contamination Or Loss Of Material By Accident. Have An Automatic Rack System For Samples With Continuous Loading. Maximum Sample Volume 30Ul. Possibility Of Viewing The Results Together With Each Histogram Or With The Reference Interval For Each Parameter; Release Of Flags For Out Of Normal Results. ?Quality Control: Included Software That Allows You To View And Print Levey Jenning Charts With Controls Or With Samples (X-B Chart). ?Minimum Storage Of 200,000 Results Note: In Addition To The Main Equipment And Reagents, The Winning Company Must Be Responsible For Sending A Printer, Toner And Paper For Printing The Reports, Q Controls
|