Ultrasound Equipment For Radiology, Obstetrics And Vascular. Technical Specifications (Minimum Characteristics): This Specification Is Intended For The Acquisition Of Completely Digital Ultrasound Equipment/System, Windows Platform, For Diagnostic Ultrasound With General Software For Applications In Internal Medicine Exams, Obstetrics/Gynecology, Small Parts (Breasts, Thyroid, Skeletal Muscle, Etc.), Cerebral Vascular, Peripheral, Abdominal); Lightweight, Versatile, Easy To Move Equipment, With Mobile Car Mounted On Swivel Wheels, Locking Systems. Ergonomic Control Panel, With Retractable Or Non-Retractable Alphanumeric Keyboard And Touch Screen Of At Least 10 Inches And Trackball Cursor Handling System; Monitor Features: A) High Resolution Lcd Color Monitor With Minimum 21.5 (Twenty-One Inches); Doppler Characteristics: A) Color Doppler; B) Simultaneous Color And Pulsed Doppler (Triplex); C) Amplitude Doppler; D) Spectral Doppler (Pulsed And Continuous). Imaging Mode: A) Mode B; B) Full Screen M Mode; C) Triplex Mode; D) Bb Mode; E) Bm Mode; F) Pulsed Doppler Mode; 8) Continuous Doppler Mode; H) Color Doppler Mode; I) Power Doppler Angio Mode; J) Tissue Doppler Mode (Spectral And Color); K) Hprf (High Frequency And Repeat Flow - Pulsed Doppler); *All Basic B, M And Pulsed Doppler Image Modes Must Allow Colorization, That Is, Changing The Gray Scale To Colored Scales (Colorize), Digital Fixed X-Ray Device – High Frequency Microprocessor Generator. Power From 50 Kw. Variable Voltage That Minimally Meets The Range Of 40 Kv To 150 Kv Or Greater. Current Variable Between 10 Ma And 600 Ma Or Greater. Minimum Exposure Time - Fixed Digital X-Ray Device – High Frequency Microprocessed Generator. Power From 50 Kw. Variable Voltage That Minimally Meets The Range Of 40 Kv To 150 Kv Or Greater. Current Variable Between 10 Ma And 600 Ma Or Greater. Minimum Exposure Time From 1Ms To 4S. X-Ray Tube, Fine Focus Equal To Or Less Than 0.6Mm And Coarse Focus Equal To Or Less Than 1.2 Mm; Minimum Rotating Anode 3,200 Rpm; Minimum Anode Thermal Capacity Of 200 Khu. Insertion Of Additional Cu Or Al Filters Into The Emitter Port With Their Appropriate Characteristics; Column With Longitudinal Displacement From 125 Cm; Tube Rotation Around Axis +/-90 Degrees; Collimator With Luminous Field Indication And Automatic Switching Off; Distance From The Focal Point Of At Least 100 Cm. Exam Table With Floating Top With Minimum Dimensions Of 200 X 75 Cm, Minimum Longitudinal Displacement Of +/- 40 Cm And Transverse Displacement +/-12 Cm. Load Capacity Supported By The Table Of At Least 200 Kg. Bucky Mural Minimum Vertical Displacement Of Flat Detector With Approximate Dimensions Between 34 X 42 Cm Or Greater. Wired Or Wireless (Mobile) Detector And Cesium Iodide Scintillator, Enabling Examinations On The Table, On The Bucky Wall Or Outside The Table, Stretcher And Wheelchair. Active Matrix Of At Least 1990 X 2048 Pixels. Post-Processed Image Depth Of At Least 14 Bits, 01/14/2026 - 13:56:52, 01/14/2026 - 13:56:53
Contact Information
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 107448286
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.