Respirometric Meter For Dbosystem Bod Meter (Biochemical Oxygen Demand) Using A Simplified Respirometric Method Without The Use Of Mercury With Manometric Measurements Using A Pressure Sensor. Deve Possuir Pelo Menos 6 Canais Para Operação De Pelo Menos 6 Amostras No Mesmo Equipamento. Display Led Digital Com Leitura Mínima De 2 Dígitos. Sistema De Agitação Indutivo. Complete Set For Performing The Bod Test According To The Respirometric Method Of The Standard Methods For The Examination Of Water And Wastewater (In Its Most Recent Edition). Armazenamento De Leituras Diárias Mínima De 5 Dias. Alimentação Por Fonte Bivolt E Pilhas Para Evitar Que Quedas De Energia Interrompam A Análise. 110 Ou 220V (Seletor De Voltagem). It Must Be Accompanied By 12 Bottles (6 For Use And 6 Reserves) With Accessories For The Same Proportion. It Comes With: Rbc Calibration Certificate In Accordance With The Requirements Of The Iso 17025 System For Inmetro Approval., Pilsen-Type Water Distilleranti-Corrosive Treatmenttextured Epoxy Electrostatic Paintingvapor Collector And Parts That Come Into Contact With Water Distilled In Stainless Steel And Inert Materialseasy Installationyield: 5 Liters Per Hourpurity: Below 4 Us, With Input Up To 300 Usconductivity: Up To 3.5 Us/Cm With Input 310 Us/Cmelectrical Control: On/Off Switchactivation Indicator: Pilot Lampheating System: Shielded Tubular Resistance In Stainless Steel 304Material: Distillation Tube, Lid And Boiler In Stainless Steel Level Sensor: Electronic With Automatic Shutdown In Case Of Lack Of Waterboiler: 304 Stainless Steel Without Welds Or Seamspower: 3500Wincluded Accessories: Support For Wall Mounting, Screws And Plugs., Benchtop Ise Meter With Selective Ion Electrode For Fluoride Meter Used For Determination Meter Used For Determination Of Fluoride.Display: Lcd.Electrode Calibration Condition Indication.Measuring Range: 0 To 19999Measuring Unit: M, Ppm, %Resolution: 1, 2, 3 Significant Digitsrelative Accuracy: ±0.2 Mv Or 0.05% Or Whatever Largest.Calibration: 1 To 5 Points.Non-Volatile Memory For Storage Of Measurement And Calibration Data Must Have:- Combined Electrode For Ion Selective Fluoride- At Least Two Standard Fluoride Solutions With Different Concentrations For Calibrating The Equipment In The Range Used (Each Bottle With At Least 250 Ml)- Tissab Iii Solution For Adjusting The Ionic Strength (Bottle With At Least 500 Ml).- Other Solutions That Are Necessary For The Determination Of Fluoride Ions.- Support For The Electrode- Instruction Manual In Portuguese- Iso/Iec 17025 Calibration Certificate.- Selective Ion Electrode For The Determination Of Extra Fluoride. Mains Power Supply., Magnetic Stirrer Without Heatingcapacity: 1 Liter Rotation Control: 50 To 120 Rpmmetallic Body With Epoxy Painting Power Supply: 110/115 V, Jar Test Equipmentequipment For Flocculation Testing (Jar Test), Microprocessed And Digital, Intended For Carrying Out Up To Six Simultaneous Tests, With Transmission Of Mechanical Agitation By Means Of Paddles, Ensuring Uniform And Controlled Movement. The System Must Allow The Programming Of Speed Ramps And Thresholds. The Equipment Must Allow The Programming Of At Least Four Automatic Programs, Containing Ramp And Plateau Stages (Segments), In Addition To A Program For Manual Operation. Cada Estágio Deverá Possibilitar Ajuste Independente De Velocidade (0 A Até Pelo Menos 300
Contact Information
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 107349478
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.