|
Tender For Online Rate Contract Tender For Surgical & Consumables For Cardiothoracic And Vascular Surgery (Ctvs) To Various Hospitals Of Government Of Madhya Pradesh For A Period Of 18 Months , Consumables , 5 Lumens Thermodilution Pa/Swan Ganz Catheter, , Absorbable Hemostat Powder With Microporous Polysaccharide Hemosphere (Mph) Technology In One Single Sterile Pack For 3 Gms, In Bellow Applicator. , Absorbable Hemostat Powder With Microporous Polysaccharide Hemosphere (Mph) Technology In One Single Sterile Pack For 5 Gms, In Bellow Applicator. , Absorbable Hemostat Powder With Microporous Polysaccharide Hemosphere (Mph) Technology In One Single Sterile Pack For 1 Gms, In Bellow Applicator. , Absorbable Porcine Gelatin Based Topical Absorbable Flowable Hemostat With 6Cc Syringe Pre-Filled With Hemostatic Matrix.2000 Iu Of Sterile Lyophilized Human Thrombin Total Volume 8Ml With 14.3 Cm White Applicator Tip & 14.6 Cm Blue Flexible Applicator Tip. , Act Tube Compatible With Helena Actalyke Mini-Ii Machine , Act Tube Compatible With Helena Actalyke Xl Machine , Adult Arterial Filter With Bypass Loop -The Arterial Filter Should Be For Adult Use. Priming Volume Should Not Be More Than 120 Ml. Filter Pore Size Should Be 30- 40 Micron. The Outlet And Inlet Blood Posts Should Be 3/8. The Filter Should Allow Maximum Blood Flow Rate Of 4.0 To 6.0 L / Min. The Filter Should Be Provided With A Bypass Loop At The Inlet And Outlet Port. , Adult Hemoconcentrator-The Priming Volume Should Be 70 Ml • Effective Surface Area Of The Fibers Should Be ˜1 Micron • Blood Port Should Be ¼ With Luer Locks • Filtrate Port Should Be ½ -1/4Adapter. , Adult Oxygenator-• Priming Volume Should Be Less Than 190Ml• Blood Flow Range Should Be 0-6 Lts/Min.• Oxygen Transfer Should Be Atleast 400Ml/Min.• Heat Exchange Efficiency Should Not Be Less Than 0.50.• Housing Material Should Be Of Polycarbonate. • Effective Gas Exchange Surface Area Of The Fibers Should Be From 1.2 To 2.4M2 Gas Exchange Fibre Material Shud Be Polypropylene [P P]• Heat Exchanger Fibre Should Be Made Of Olyurethane[Tpu] And Surface Area Should Be Approx. 0.2 To 0 .3 M2 Blood Inlet Port -From Pump. 3/8 Blood Outlet Port 3/8 Cardioplegia Port 1/4 Gasinlet Port 1/4 Gas Outlet Port 1/4 Water Ports ½ Maximum Pressure Blood Inlet 1000 Mmhg Water Inlet 42 Psi • Blood Storage Capacity Of Hard Shell Reservoir Should Be Approx. 4000-5000Ml• Minimum Operating Volume Of Reservoir Should Be 200Ml. Head Exchancer With Oxyganator. , Bioprosthesis 2Nd Generation, Mitral- 25 Mm , Bioprosthesis 2Nd Generation, Mitral- 27 Mm , Bioprosthesis 2Nd Generation, Mitral- 29 Mm , Bioprosthesis 2Nd Generation, Mitral- 31 Mm , Bioprosthesis 2Nd Generation, Mitral- 33 Mm , Bovine Pericardial Patch 6X 6Each , Breathing Circuit-Ventilator Circuit For Adults. , Cabg Drape Kit, Specification Attached , Cardiac Tissue Positioner System For Cardiac Apex : For Beating Heart Surgery (Suction Based-Starfish Type), , Cardiac Tissue Stabilization System: For Beating Heart Surgery (Suction Based-Octopus Type) Suitable With Standard Retractors Complete Set, , Cardio Vascular Patch Size Hard Ptfe Felt 10 X 10 , Cardioplegia Delivery System (To Be Supplied With Suitable Holder) , Cardioplegia Heat Exchanger- It Should Have Priming Volume Less Than 50 Ml, Blood Flow Rate Should Be Between 0 To 600 Ml/Min, Filter Pore Should Be Around 100 Um, Inlet Connection Should Be 1/4 , Outlet Connection Should Be 3/16. Heat Exchange Surface Area Should Be ˜.20M 2,Heat Exchange Should Be Of Stainless Steel Corrugated/ Convoluted Pipes. Bubble Trap Should Be Integrated For Highly Efficient Debubbling, Exchangeable Water In /Water Out Blood Flow Path Bottom Up It Should Have A Stopcockprime /Perfusion For Easypriming. It Should Have Tip In The Surgeon Pack, So That It Can Be Connected To Cardioplegia Cannula. It Should Be Available Both In 4:1 Configurations. , Customised Tubing/Heart Lung Pack With -Pediatric Design- P.V.C. Tubing,Complete Set Of Tubes, Connectors And Accessories, Arterial Pump Silicon Headsuction / Gas Line 1/4 . Should Have Soft Tubing . , Customised Tubing Pack/Heart Lung Pack With Adult Design- P.V.C. Tubing, Complete Set Of Tubes, Connectors And Accessories, Arterial Pump Head Suction Silicon / Gas Line 1/4 . Should Have Soft Tubing . , Disposable Surgical Gowns , Extra Corporeal Membrane Oxygenator (Ecmo) Circuit , Humidifier (Hme Filter)-Adult Size. , Humidifier (Hme Filter)-Paediatrics Size. , Loop No. 1 Nylon, Nonabsorbable, Sterile, Monofilament Polyamide No. 1 Suture (4 Metric), 150 Cm., Looped On 48 Mm., 1/2 Circle Round Bodied Heavy Needle , Lung Stapler Cartridge (Purple) 45 Mm , Lung Cuttiing Stapler Cartridge 60Mm , Monofilament Glycomer 3-0, 75Cm , Undyed 19Mm 3/8 Circle Reverse Cutting , Neonatal Oxygenators-Priming Volume Maximum Should Be Less Than 50Ml. Minimum Operating Volume Approx. 30 Ml • Maximum Blood Flow Rate Should Be 0.2-1.2.Ltrs/Min. • Oxygen Transfer Should Not Be Less • Oxygen Transfer Should Not Be Lessthan 250Ml/Min.• Heat Exchange Efficiency Should Not Be Less Than 0.65.Surface Area Of The Fibers Should Be Approx0.8 To 1.0M2 . • Heat Exchanger Fibre Material Should Be Made Of Polyurethane And Surface Area Should Be Approx. 0.22-0.50M2 . Blood Inlet Port 3/8 Blood Outlet Port 1/4Cardioplegia Port 1/4 Gas Inlet Port 1/4 Gas Outlet Port 1/4Water Port 1/2 Maximum Pressure Blood Inlet 1000Mmhg,Water Inlet 42 Psi • Blood Storage Capacity Of Hard Shellreservoir Should Be Max 3000Ml.• Minimum Operative Volume Of Hard Shell Reservoir Should Be 150Ml. , Oxidized Regenerated Cellulose Based Topical Absorbable Hemostat, Structured Non-Woven Material, With Bactericidal Property. Ease-Of-Use In Both Open And Minimally Invasive Procedures. Can Be Repositioned Easily Without Sticking To Instruments, Size 4X4 Inch , Paeditric Oxygenator-Priming Volume Maximum Should Be Less Than 110Ml.Minimum Operating Volume Approx. 30 Ml • Maximum Blood Flow Rate Should Be 2.8.Ltrs/Min. • Oxygen Transfer Should Not Be Less Than 250Ml/Min.• Pressure Drop Should Be Least-Up To 100Mmhg Or Less.• Heat Exchange Efficiency Should Not Be Less Than 0.65. Surface Area Of The Fibers Should Be Approx0.8 To 1.0M2 . • Heat Exchanger Fibre Material Shouldbe Made Of Polyurethane [Tpu] And Surface Area Should Be Approx. 0.13M2 To 0.15M2 . Blood Inlet Port 3/8 Blood Outlet Port 1/4 Cardioplegia Port 1/4 Gas Inlet Port 1/4 Gas Outlet Port 1/4Water Port 1/2 Maximum Pressure Blood Inlet 1000Mmhg,Water Inlet 42 Psi • Blood Storage Capacity Of Hard Shell Reservoir Should Be Max 3000Ml.• Minimum Operative Volume Of Hard Shell Reservoir Should Be 100Ml. , Polypropylene, 4-0 75Cm, Blue 16 / 17Mm, 1/2 Circle Taper Point, Double Arm, , Polypropylene, 4-0 90 Cm, Blue 26Mm 1/2 Circle Taper Point, Double Arm, , Polypropylene, 5-0 75 Cm, Blue 13Mm 1/2 Circle Taper Point, Double Arm, , Polypropylene, 5-0 75 Cm, Blue 16 Mm 3/8 Circle Taper Point, Double Arm, , Polypropylene, 5-0 75 Cm, Blue 17Mm 1/2 Circle Taper Point, Double Arm, , Polypropylene, 6-0 75 Cm, Blue 11Mm 3/8 Circle Taper Point, Double Arm, , Polypropylene, 6-0 75 Cm, Blue 13Mm 1/2 Circle Taper Point, Double Arm, , Polypropylene, 7-0 75 Cm Blue 8Mm 3/8 Circle Taper Point, Double Arm, , Polypropylene, 8-0, 60 Cm Blue, 6.5 Mm 3/8 Circle Taper Point, Double Arm, , Polypropylene, 8-0, 60 Cm Blue, 8 Mm 3/8 Circle Ever Point, Double Arm, , Polypropylene, 7-0, 60 Cm Blue, 9-9.3 Mm 3/8 Circle Ever Point, Double Arm, , Ptfe Coated Cardiac Pacing Wire* 3-0 60Cm - 2X12, 17Mm 1/2 Circle Taper Point , Radio Opaque Line Gauge Piece (Pack Of 100) , Radio Opaque Line Sponge (Pack Of 5) , Rigid Annuloplasty Ring With Sizer & Holder (Complete Set), Mitral (Size- 24 Fr, 26 Fr, 28 Fr, 30 Fr, 32 Fr, 34 Fr, 36 Fr) , Semi Rigid Annuloplasty Ring With Sizer & Holder (Complete Set),Mitral (Size- 24 Fr, 26 Fr, 28 Fr, 30 Fr, 32 Fr, 34 Fr, 36 Fr) , Semi Rigid Annuloplasty Ring With Sizer & Holder (Complete Set),Tricuspid (Size- 26 Fr, 28 Fr, 30 Fr, 32 Fr, 34 Fr, 36 Fr) , Silicone Coated, Braided Polyester, 2-0 Blue & White 8X36/90Cm Da, Oval Pledget 3X6mm, Firm Pledget, Taper Point, 1/2 Circle, 16Mm, , Silicone Coated, Braided Polyester, 2-0 4/5 Blue & 4/5 White 8X30/75Cm Da, Pledget (4.5X6 Mm, 4.5X7 Mm ) X 1.5 Mm, Firm Pledget, Taper Point, 1/2 Circle, 25Mm, , Single Leaflet Machenical Heart Valve Tilting Disc Rotatable Size (17Mm To 29 Mm)/Any Size Aortic , Single Leaflet Machenical Heart Valve Tilting Disc Rotatable Size (23Mm To 33Mm)/Any Size Mitral , Pedaitric Hemoconcentrator-It Should Have Priming Volume Approx 35Ml. • Effective Surfacearea Of The Fibers Should Be Approx 0.5M Sq. • Blood Port Should Be ¼With Luer Locks. • Filtrate Port Should Be ½. •Maximum Trans-Membrane Pressure Should Be 500Mm Hg. • It Should Have Tubing Lines Along With Reservoir Bag.Should Be ¼With Luer Locks. • Filtrate Port Should Be ½. •Pressure Should Not Be More Than 500Mm Hg. • It Should Have Tubing With Reservoir Bag. , Sternal Closure Implant Made Of Biocompatible Peek (Polyetheretherketone) Polymer With Consistent Tension Across Sternotomy Or Fracture Of The Sternum (Pack Of 5 Bands) , Transparent Sterile Adhesive Dressing 6Cm X 7Cm ( Centerline Dressing) , Transparent Sterile Adhesive Dressing 7Cm X 8.5Cm ( Centerline Dressing) , Titanium Vascular Clips (Large) , Titanium Vascular Clips (Medium) , Titanium Vascular Clips (Small) , Titanium Vascular Clips (Micro) , Vascular Eptfe Carbon Impregnated Flex Grafts 6 Mm X 50 Cm , Vascular Eptfe Carbon Impregnated Flex Grafts 6 Mm X 80 Cm , Vascular Eptfe Carbon Impregnated Flex Grafts 7 Mm X 80 Cm , Vascular Eptfe Carbon Impregnated Flex Grafts 8 Mm X 80 Cm , Vascular Eptfe Carbon Impregnated Straight Graft 7 Mm X 50 Cm , Vascular Eptfe Carbon Impregnated Tapped Grafts With Hemodynamic Cuff 4-6 Mm X 25 Cm , Vascular Eptfe Carbon Impregnated Tapped Grafts With Hemodynamic Cuff 4-6 Mm X 30 Cm , Vascular Eptfe Carbon Impregnated Tapped Grafts With Hemodynamic Cuff 4-6 Mm X 35 Cm , Dacron Collagen Impregnated Corrugated Vascular Graft (Sizes-12-6 Mm Y Graft) , Dacron Collagen Impregnated Corrugated Vascular Graft (Sizes- 6Mm. X 60 Cm Straight) , Arterial Cannula Curved Tip Wire Reinforced, Plastic Tip, Arterial Cannulae Vented, Size- 6 Fr , Arterial Cannula Curved Tip Wire Reinforced, Plastic Tip, Arterial Cannulae Vented, Size- 8 Fr , Arterial Cannula Curved Tip Wire Reinforced, Plastic Tip, Arterial Cannulae Vented, Size- 10 Fr , Arterial Cannula Curved Tip Wire Reinforced, Plastic Tip, Arterial Cannulae Vented, Size- 12 Fr , Arterial Cannula Curved Tip Wire Reinforced, Plastic Tip, Arterial Cannulae Vented, Size- 14 Fr , Arterial Cannula Curved Tip Wire Reinforced, Plastic Tip, Arterial Cannulae Vented, Size- 16 Fr , Adult Arterial Cannula For Arch Cannulation Dip, Metal Tip Curved Arterial Cannulae Vented 3/8 Inch Connector, Sizes- 18 Fr. , Adult Arterial Cannula For Arch Cannulation Dip Metal Tip Curved Arterial Cannulae Vented 3/8 Inch Connector, Sizes- 20 Fr. , Adult Arterial Cannula For Arch Cannulation Dip Metal Tip Curved Arterial Cannulae Vented 3/8 Inch Connector, Sizes- 22 Fr. , Adult Arterial Cannula For Arch Cannulation Dip Metal Tip Curved Arterial Cannulae Vented 3/8 Inch Connector, Sizes- 24 Fr. , Aortic Bovine Pericardial Bioprosthetic Surgical Valve Aldehyde-Free Dry Storage (Integrity Preservation Treatment That Enables Aldehyde-Free Dry Storage, An Expandable Co-Cr Band And Fluoroscopically Visible Size Markers, . Sizes-19 Mm. , Aortic Bovine Pericardial Bioprosthetic Surgical Valve Aldehyde-Free Dry Storage (Integrity Preservation Treatment That Enables Aldehyde-Free Dry Storage, An Expandable Co-Cr Band And Fluoroscopically Visible Size Markers, . Sizes- 21 Mm. , Aortic Bovine Pericardial Bioprosthetic Surgical Valve Aldehyde-Free Dry Storage (Integrity Preservation Treatment That Enables Aldehyde-Free Dry Storage, An Expandable Co-Cr Band And Fluoroscopically Visible Size Markers, . Sizes-23 Mm. , Aortic Bovine Pericardial Bioprosthetic Surgical Valve Aldehyde-Free Dry Storage (Integrity Preservation Treatment That Enables Aldehyde-Free Dry Storage, An Expandable Co-Cr Band And Fluoroscopically Visible Size Markers, . Sizes-25 Mm. , Aortic Bovine Pericardial Bioprosthetic Surgical Valve Aldehyde-Free Dry Storage (Integrity Preservation Treatment That Enables Aldehyde-Free Dry Storage, An Expandable Co-Cr Band And Fluoroscopically Visible Size Markers, . Sizes-27 Mm. , Aortic Cannula Wire Reinforced Beveled Tip With Elongated 1 Piece With Adjustable Hemostasis Introducer System With Depth Markings, Size - 6 Fr , Aortic Cannula Wire Reinforced Beveled Tip With Elongated 1 Piece With Adjustable Hemostasis Introducer System With Depth Markings, Size - 8 Fr. , Aortic Cannula Wire Reinforced Beveled Tip With Elongated 1 Piece With Adjustable Hemostasis Introducer System With Depth Markings, Size - 10 Fr. , Aortic Cannula Wire Reinforced Beveled Tip With Elongated 1 Piece With Adjustable Hemostasis Introducer System With Depth Markings, Size - 12 Fr. , Aortic Cannula Wire Reinforced Beveled Tip With Elongated 1 Piece With Adjustable Hemostasis Introducer System With Depth Markings, Size - 14 Fr. , Aortic Cannula Wire Reinforced Beveled Tip With Elongated 1 Piece With Adjustable Hemostasis Introducer System With Depth Markings, Size - 16 Fr. , Aortic Punch Long Handle- A Conical Tip Should Be There For Easy Insertion By Straight Or Button Hole Technique, Ten Blade Sizes For Trimming To Desired Size And Shape. Sizes -2.8 Mm. , Aortic Punch Long Handle-A Conical Tip Should Be There For Easy Insertion By Straight Or Button Hole Technique, Ten Blade Sizes For Trimming To Desired Size And Shape. Sizes -3.0 Mm. , Aortic Punch Long Handle-A Conical Tip Sshould Be There For Easy Insertion By Straight Or Button Hole Technique, Ten Blade Sizes For Trimming To Desired Size And Shape. Sizes -3.5 Mm. , Aortic Punch Long Handle-A Conical Tip Should Be There For Easy Insertion By Straight Or Button Hole Technique, Ten Blade Sizes For Trimming To Desired Size And Shape. Sizes -4 Mm. , Aortic Root Cannula With Vent Line-Radioopaque Tips With Vent Line, Flanged Standard Tip And Standard Introducer, Sizes- 5Fr , Aortic Root Cannula With Vent Line-Radioopaque Tips With Vent Line, Flanged Standard Tip And Standard Introducer, Sizes- 7 Fr , Aortic Root Cannula With Vent Line-Radioopaque Tips With Vent Line, Flanged Standard Tip And Standard Introducer, Sizes- 9 Fr , Aortic Root Cannula With Vent Line-Radioopaque Tips With Vent Line, Flanged Standard Tip And Standard Introducer, Sizes- 12 Fr , Aortic Root Cannula With Vent Line-Radioopaque Tips With Vent Line, Flanged Standard Tip And Standard Introducer, Sizes- 14 Fr , Arteriotomy Shunts - Intracoronary Long Shunts.-Should Be Beveled Tip, Sizes -In Mm.- 1.25 , Arteriotomy Shunts - Intracoronary Long Shunts-Should Be Beveled Tip, Sizes -In Mm.- 1.5 , Arteriotomy Shunts - Intracoronary Long Shunts-Should Be Beveled Tip, Sizes -In Mm.- 1.75 , Arteriotomy Shunts - Intracoronary Long Shunts-Should Be Beveled Tip, Sizes -In Mm.- 2 , Arteriotomy Shunts - Intracoronary Long Shunts-Should Be Beveled Tip, Sizes -In Mm.- 2.5 , Arteriotomy Shunts - Intracoronary Long Shunts-Should Be Beveled Tip, Sizes -In Mm.- 2.75 , Arteriotomy Shunts - Intracoronary Long Shunts-Should Be Beveled Tip, Sizes -In Mm.- 3 , Arteriotomy Shunts - Intracoronary Long Shunts-Should Be Beveled Tip, Sizes -In Mm.- 3.5 , Endotracheal Tube With Cuff Should Have Low Pressure High Volume Cuff Size- 6 Mm. , Endotracheal Tube With Cuff Should Have Low Pressure High Volume Cuff Size- 6.5 Mm. , Endotracheal Tube With Cuff Should Have Low Pressure High Volume Cuff Size- 7 Mm. , Endotracheal Tube With Cuff Should Have Low Pressure High Volume Cuff Size- 7.5 Mm. , Endotracheal Tube With Cuff Should Have Low Pressure High Volume Cuff Size- 8 Mm. , Endotracheal Tube With Cuff Should Have Low Pressure High Volume Cuff Size- 8.5 Mm.
|