Tender For 2.28.1Surface Dressing Of The Ground Including Removing Vegetation And Inequalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Up To 50 M And Lift Up To 1.5 M. All Kinds Of Soil , 2.6.1Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. All Kinds Of Soil 2.6.1 , 4.1.3Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) : 4 Graded Stone Aggregate 20 Mm Nominal Size) 4.1.3 , 5.3Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size). 5.3 , 5.9.4Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : Shelves (Cast In Situ) 5.9.4 , 5.22.6Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 5.22.6 , 16.11Dry Stone Pitching 22.5 Cm Thick Including Supply Of Stones And Preparing Surface Complete. , 11.26.1Kota Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) : 11.26.1 25 Mm Thick , 10.1Structural Steel Work In Single Section, Fixed With Or Without Connecting Plate,Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , 8.25.3Providing And Fixing 2Nd Class Teak Wood Plain Lining Tongued And Grooved, Including Wooden Plugs Complete With Necessary Screws And Priming Coat On Unexposed Surface. 8.25.3 : 20 Mm Thick , 13.99.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : 13.99.1 One Or More Coats On Old Work , 13.71Lettering With Black Japan Paint Of Approved Brand And Manufacture , 13.65.1 Painting With Black Anti-Corrosive Bitumastic Paint Of Approved Brand And Manufacture To Give An Even Shade : 13.65.1 Two Or More Coats On New Work , 7.1.1Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1 :6:12 (1 Cement: 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level With : 7.1.1 Cement Mortar 1 :6 (1 Cement: 6 Coarse Sand) , 16.71Providing And Fixing G.I. Chain Link Fabric Fencing Of Required Width In Mesh Size 25X25 Mm Made Of G.I. Wire Of Dia 3 Mm Including Strengthening With 2 Mm Dia Wire Or Nuts, Bolts And Washers As Required Complete As Per The Direction Of Engineer-In-Charge. , 4.1Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii): 4 Graded Stone Aggregate 12.5Mm Nominal Size) , 2.25Filling Available Excavated Earth(Excluding Rock) In Trenches, Plinth,Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth,Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. , 7.8.1Coursed Rubble Masonry With Hard Stone (First Or Second Sort) In Superstructure Above Plinth Level And Upto Floor Five Level. 7.8.1 Masonry Work (First Sort), In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , 16.11Dry Stone Pitching 22.5 Cm Thick Including Supply Of Stones And Preparing Surface Complete. , 9.1.1Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Second Class Teak Wood , 9.4.1Extra For Additional Labour For Circular Works, Such As In Frames Of Fan Light 9.4.1 : Second Class Teak Wood , 11.33.125 Mm Wooden Planking, Tongued And Grooved In Flooring, Including Fixing With Iron Screws Complete With : Second Class Teak Wood 11.33.1 , 13.68.1French Spirit Polishing : Two Or More Coats On New Works Including A Coat Of Wood Filler 13.68.1 , 9.5.1.1Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) 9.5.1 Second Class Teak Wood 9.5.1.1 35 Mm Thick Shutters , 9.72.1Providing And Fixing Bright Finished Brass Butt Hinges With Necessary Screws Etc. Complete : 125X85x5.5 Mm (Heavy Type) , 9.74.4Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Necessary Screws Etc. Complete :100X10 Mm , 9.75.1Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc. Complete : 300X16x5 Mm , 8.10.2Providing And Fixing Stone Slab With Table Rubbed, Edges Rounded And Polished, Of Size 75X50 Cm Deep And 1.8 Cm Thick, Fixed In Urinal Partitions By Cutting A Chase Of Appropriate Width With Chase Cutter And Embedding The Stone In The Chase With Epoxy Grout Or With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 6 Mm Nominal Size) As Per Direction Of Engineer-In-Charge And Finished Smooth. 8.10.2: Granite Stone Of Approved Shade , 12.1.1Providing Corrugated G.S. Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces), Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 12.1.1 1.00 Mm Thick With Zinc Coating Not Less Than 275 Gm/M² , 12.4.1Providing Ridges Or Hips Of Width 60 Cm Overall Width Plain G.S. Sheet Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Dia G.I. Limpet And Bitumen Washers Complete. 12.4.1 0.80 Mm Thick With Zinc Coating Not Less Than 275 Gm/M² , 10.2Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , 9.62.1Providing And Fixing Isi Marked Oxidised M.S. Sliding Door Bolts With Nuts And Screws Etc. Complete : 300X16 Mm , 13.65.1 Painting With Black Anti-Corrosive Bitumastic Paint Of Approved Brand And Manufacture To Give An Even Shade : 13.65.1 Two Or More Coats On New Work , 13.71Lettering With Black Japan Paint Of Approved Brand And Manufacture , 15.14.1 Dismantling Wood Work In Frames, Trusses, Purlins And Rafters Up To 10 Metres Span And 5 Metres Height Including Stacking The Material Within 50 Metres Lead : 15.14.1 Of Sectional Area 40 Square Centimetres And Above Cum 3345.90 15.14.2 Of Sectional Area Below 40 Square Centimetres , 15.56Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead. , 15.12.1Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead : 15.12.1 Of Area 3 Sq. Metres And Below , 15.28.1Dismantling Roofing Including Ridges, Hips, Valleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of: 15.28.1 G.S. Sheet , 15.39.3Dismantling Wooden Boardings In Lining Of Walls And Partitions, Excluding Supporting Members But Including Stacking Within 50 Metres Lead : 15.39.3 Thickness Above 25 Mm Up To 40 Mm , 14.16.1.1Renewing Wooden Beams In Roofs Including Making Good The Holes In Walls And Painting With Oil Type Wood Preservative Of Approved Brand And Manufacture Complete, Including Removal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In-Charge. 14.16.1 Not Exceeding 4.00 Metres In Length. 14.16.1.1 Sal Wood Beams , 14.15.1Renewing Wooden Battens In Roofs, Including Making Good The Holes In Wall And Painting With Oil Type Wood Preservative Of Approved Brand And Manufacture Complete, Including Removal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In-Charge. 14.15.1 Sal Wood Battens , 14.2.1 Fixing Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15 X 10 X 10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In-Charge. 14.2.1 Door Chowkhats , 14.2.2 Window Chowkhats , 24.1Raking Out Joints Of Stone Masonry Surface To The Required Width And Depth, With Due Care And Precaution, By Mechanical / Manual Means, Including Preparing And Cleaning The Surface For Re-Pointing/ Refilling Of Joints, Including Disposal Of Rubbish To The Dumping Ground Within 50 Metre Lead. , 24.2Providing And Fixing Double Scaffolding System (Cup Lock Type) On The Exterior Side Of Building/Structure, Upto 25 Metre Height, Above Ground Level, Including Additional Rows Of Scaffolding In Stepped Manner As Per Requirement Of Site, Made With 40Mm Dia M.S. Tube, Placed 1.5 Metre Centre To Centre, Horizontal & Vertical Tubes Joint With Cup & Lock System With M.S. Tubes, M.S. Tube Challis, M.S. Clamps And Staircase System In The Scaffolding For Working Platform Etc. And Maintaining It In A Serviceable Condition For Execution Of Work Of Cleaning And/ Or Pointing And/ Or Applying Chemical And Removing It Thereafter. The Scaffolding System Shall Be Stiffened With Bracings, Runners, Connecting With The Building Etc, Wherever Required, If Feasible, For Inspection Of Work At Required Locations With Essential Safety Features For The Workmen Etc., Complete As Per Directions And Approval Of Engineer-In-Charge. , 24.3Cleaning The Sand Stone Surface And Removing Dirt, Dust, Bird Dropping, Grease, Oil, Algae, Fungus, Monkey Beats, Vegetable Growth Etc., Including Providing, Applying And Washing The Surface With Liquid Ammonia Chemical Of 5% Solution And Other Chemical Cleaning Agent As Approved By Archaeological Survey Of India/ Engineer-In-Charge, Of Approved Brand And Manufacturer, With The Help Of Required Scrubbers And Also Cleaning With Machine Operated Water Jet Mixed With Desired Quantity Of Fine Silica Where Ever Required, Without Causing Any Scratching/ Damage To The Stone Surface And Finally Washing The Surface With Clean Water With The Help Of Pressure Jet Machine, Complete In All Respect, Including Taking All Precautions To Safeguard Ventilators, Windows, Doors Etc. By Suitable Covering So As To Avoid Any Damage To The Building/Structure, All As Per Direction Of Engineerin-Charge (The Rate Is Inclusive Of All Materials & Labours Involved Except Scaffolding). , 24.4Providing And Applying Antifungal Wash Treatment Using 3% Solution Of Sodium Pentachlorophenate, Of Reputed Brand And Manufacturer, On Cleaned Sand Stone Surface At Desired Locations As Per Direction Of Engineer-In-Charge (The Rate Is Inclusive Of All Materials & Labours Involved Except Scaffolding). , 24.7Applying Two Or More Coat Of Ethyl Silicate Chemical As Approved By Archaeological Survey Of India/ Engineer-In-Charge, Of Approved Brand And Manufacturer, With Brush Or Spray On The Existing Stone Masonry Surface Till There Is No Further Absorption Of Chemical By Stone Surface, Including Protecting The Applied Surface From Direct Sunlight By Suitable Means During Application, All Complete As Per Direction Of The Engineer-In-Charge (The Rate Is Inclusive Of All Materials & Labours Involved Except Scaffolding). , 24.8 Applying Breathable, Non-Reactive, Antifungal, And Water Repellant Silane/Siloxane Chemical As Approved By Archaeological Survey Of India/ Engineer-In-Charge, Of Approved Brand And Manufacture, Diluted With Solvent Mineral Turpentine Oil In The Ratio Of 1:12 (One Part Of Approved Chemical :12 Part Of Turpentine Oil), On The Existing Sand Stone Masonry Surface With Two Or More Coats To Give Uniform Application Of Chemical On The Surface, All Complete As Per Direction Of Engineer-In-Charge (The Rate Is Inclusive Of All Materials & Labours Involved Except Scaffolding). , 13.88Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete , 13.1.112 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 13.26 Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , 13.82.2Wall Painting With Acrylic Emulsion Paint, Having Voc (Volatile Organic Compound ) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour. , 9.5Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) 9.5.1 Second Class Teak Wood 9.5.1.1 35 Mm Thick Shutters , 13.114Melamine Polishing On Wood Work (One Or More Coat). , 14.85 Taking Out Existing Wooden Door Shutter, Repair By Cutting, Painting Etc. And Refixing Of Repaired Door Shutters To Existing Door Frames, Including Replacement Of Hinges With Screws, Etc. As Required, All Complete As Per The Direction Of The Engineer-In-Charge. , 14.73Providing And Fixing Bright Finished Brass Casement Window Fasteners Or Peg Stays To Windows/ Ventilators With Necessary Welding And Machine Screws Etc. Complete. , 9.12 Extra For Providing Frosted Glass Panes 4 Mm Thick Instead Of Ordinary Float Glass Panes 4 Mm Thick In Doors, Windows And Clerestory Window Shutters. (Area Of Opening For Glass Panes Excluding Portion Inside Rebate Shall Be Measured). Sqm , 9.7.7.1Float Glass Panes 9.7.7.1 4 Mm Thick Glass Pane (Weight Not Less Than 10 Kg/Sqm). , 14.83Hacking Of Cement Concrete Flooring Including Cleaning For Surface Etc. Complete As Per Direction Of The Engineer-In-Charge , 11.33.125 Mm Wooden Planking, Tongued And Grooved In Flooring, Including Fixing With Iron Screws Complete With : 11.33.1 Second Class Teak Wood , 7.8.1Coursed Rubble Masonry With Hard Stone (First Or Second Sort) In Superstructure Above Plinth Level And Upto Floor Five Level. Masonry Work (First Sort), In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , 10.2Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , 13.65.1 Painting With Black Anti-Corrosive Bitumastic Paint Of Approved Brand And Manufacture To Give An Even Shade : 13.65.1 Two Or More Coats On New Work , 12.1.1Providing Corrugated G.S. Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces), Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 12.1.1 1.00 Mm Thick With Zinc Coating Not Less Than 275 Gm/M² , 12.4.1Providing Ridges Or Hips Of Width 60 Cm Overall Width Plain G.S. Sheet Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Dia G.I. Limpet And Bitumen Washers Complete. 12.4.1 0.80 Mm Thick With Zinc Coating Not Less Than 275 Gm/M² , 12.5.1 Providing Valleys Of 90 Cm Wide Overall In Plain G.S. Sheet Fixed With Polymer Coated J, Or L Hooks, Bolts And Nuts 8 Mm Dia G.I. Limpet And Bitumen Washers Complete : 12.5.1 1.60 Mm Thick With Zinc Coating Not Less Than 350 Gm/M² , 4.1.8 1 :4:8 (1 Cement : 4 Coarse Sand (Zone-Ill) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources)
|