|
Tender For Provision Of Single Officer Living accommodation At Jourian Under Ge (South) Akhnoor.-1 Construction of Block of Single Living Accn for Offrs (Double Storey) with Permt Specification, including RCC framed structure in M-25 Design Mix with earthquack reisistance as per TI-5 of 2002, seismic Zone IV, WPT with APP membrane, ATT, finishes, PVC water Storage tanks, all internal water supply with PVC Pipe, 25 Ltr Geysers 08 Nos in Each Accn, Electric supply fittings with energy efficient light fitments and copper concealed wiring, etc complete all as specified and shown on drawings. 2 3 4 5 6 7 8 green for single phase circuits) with multi stranded copper conductor 1.5 sq mm nominal cross section area, single core ,pvc insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked with valid CML No in and including medium grade PVC concealed in wall , ISI marked with mild steel / pressed steel sunken boxed 1.60 mm thick 60 mm deep ( with earth dolly) duly painted with two coats of anticorrosive paint over a coat of red oxide primer internally, and two coats of black butuminious paint over a coat of red oxide primer externally covered with 3 mm thick hylam sheet cover for fixing of switches , socket etc, including PVC indulated PVC insulated multi stranded copper conductor 1.5 sq mm nominal cross section area single core FRLSH cable as earth continuity conductor to common earth and connecting earth doly complete al as specified and directed at site for the following : - (a) One light point controlled by one, one way way switch 5 Amps . (b) One fan point / exhaust fan point controlled by one, one way switch 5 Amps and regulator. (c) One 3 pin 5 amps switch socket outlet point controlled by one switches on the same board. (d) One 3 pin 5 amps switch socket outlet point controlled by one switches on independent board. (e) One bell point controlled by one switches 5 Amp. Description all as per item no -1 here and before but using 2.5 sq mm single core copper conductor cable multistrand FRLSH , PVC unsulated unsheathed 1100 volts grade for 5/15 amps Switch socket combination point including necessary running of 2.5 sq mm copper conductor FRLSH PVC wire earth continuity conductor along with wiring and connecting to the common earth dolly , complete all as specified and directed by Engr-in-charge. Notes for Srl item No. 1 & 2 : 1.Socket and switches measured and paid separately. 2.Proper colour coding shall be adopted for phase, neutral earth and halves. S&F for Modular switch piano flush type , single pole , one way and 5/6 Amps single module complete all as specified, S&F for Modular switch piano flush type , single pole , one way and 15/16 Amps single module complete all as specified, S&F for Modular socket outlet multipurpose having provision for 3 pin, 5/6 Amps and 2 pin 5/6 amps, 2 module piano flush type complete all as specified . S&F for Modular socket outlet multipurpose having provision for 3 pin, 15/16 Amps and 2 pin 5/6 amps, 2 module piano flush type complete all as specified . S&F for modular step type fan regulator 100/120 watt 2 module suitable for 230 volts 50Hz AC supply complete ,all as specified. Description all as per item no -1 here and before but using 4.0 sq mm single core copper conductor cable multistrand FRLSH , PVC insulated unsheathed 1100 volts grade for 5/15 amps Switch socket combination point including necessary running of 4.0 sq mm copper conductor FRLSH cable of multistranded PVC insulated unsheathed as earth continuity conductor along with wiring and connecting to the common earth dolly , complete all as specified and directed by Engr-in-charge. S&F for bell push modular 6 Amp single module complete ,all as specified. S&F for bell ding dong AC 230 volt single pole complete ,all as specified. S&F for Ceiling rose, surface bakelite 3 terminal, ISI marked for batten fitting complete ,all as specified. & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit length only complete all as specified and directed by Engr-in-Charge. S&F for Sheet metal encloser TPN MCB DB 4 way with 200 amps rated bus bar 415 volts double door with magnitic lock system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of disturbed surface to match with existing colour of wall complete all, as specified. S&F for Sheet metal encloser MCB DP SPN 8 way with 200 amps rated bus bar 240 volts double door with magnitic lock system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of disturbed surface to match with existing colour of wall complete all, as specified. & F for MCB Tripple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. & F for ceiling fan, 230 Volts, 1200 mm sweep with mian air delivary 210 CFM, service value of the fan shall be greater than 6.1 as per BIS with blades, down rod & other necessary accessories with brushless direct current motor BLDC) with out remote system and electrical connections from ceiling rose to fan teriminal complete all as specified and as directed. S&F for energy efficient Exhaust fan of 300 mm sweep, made of metal body ventil Air-DS type complete with louver with bolts nuts ans washer size of the bolt 15 cm long 12 mm dia embedded in wall including provision if PVC flexiable copper csble of size 23/0.0076 two core from ceilling rose to axhaust fan for connection and making suatable size of hole to existing brick wall for fan base complete all as specified. and directed. ( Note : Cost of suatable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted) S&F for wall mounted LED tube light fitting 20 watts batten for surface mounted anodized extruded aluminium housing , high transmissitivity diffuser , high lumen output box type fittign 230 volts and integrated electronic driver connector block etc with all accesories intenally pre wired and necesary mounting arrangments provision of new 3 core multistranded copper conductor size 23/0.193 from ceiling rose to fitting complete all as specified. and directed. S&F for MCB single pole and neutral rated capacity 32/40 Amps 240 volts breaking capacity 10 KA 'C' Curve complete all as specified and directed. S&F for MCB single pole and neutral rated capacity 5 to 32 Amps 240 volts breaking capacity 10 KA 'C' Curve complete all as specified and directed. & F for lamp holder, PVC / Polycarbonate type with back plate suitabl for batten/ slanting fittings complete all as specified and directed by Engr-in- Charge. amount of Sch ‘A’ Part-II carried over to BOQ under Srl item No. 1.02 S&F for round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting provision of new 3 core multistranded copper conductor of size 23/.193 from ceiling rose to fitting complete all as specified. and directed. DATED: ____________________ S&F for energy saving new generation environmental friendly long life versatile pressure fie cast aluminium IP 66 for secuirty light fitting luminaire with high power LEDs as light source and electronic driver of apacity 35/40watts wirh prewired and necessary mounting arrangments and provision and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 tr long bend to required shape with clamps, nut, bolts complete all as specified. and directed. S & F for metal clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20/32 Amps including removal of old unserviceable one complete all as specified and as directed. S&F for LED tube light fitting alluminium housing 2 feet x 10 watts mirror type with high output diffuser , decorative type with driver holder and LED lamp including connecting up with three core csble of size 23/0.193 from ceiling rose to fitting complete all as specified. and directed. SIGNATURE OF CONTRACTOR Supply and fix electronic meters temper proof LCD display with polycarbonate cover 1 phase 230V, 10-60 Amps, accuracy class-I 50Hz, conforming to IS- 13779, IP-54 with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and as directed. Earthing complete with galvanized steel plate elecrode of size 60 cm x 60cm x 6.0 mm thick burried Each directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth Set plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and common salt, earth lead GI wire of 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanised iron with thimbles. The other end of Gl earth wire is connected to main switch board and protected by medium grade Gl pipe of 15 mm bore. provision of 20 mm bore medium grade Gl pipe for watering including Gl funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. Cement concrete chamber of PCC (1:3:6) type C-2using 40 mm graded stone aggregates. The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete (1:2:4) type B-1 using 20 mm graded stone aggregate and MS angle iron 50 x 50 x 6 mm frame including two coats of painting over a red oxide to exposed steel surfaces. excavation in soft/loose soil, returning filling in and removal of surplus soil to a distance of 50 mm as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2009). Note: (i) Gl earth lead 4.0 mm dia and Gl protection pipe 15 mm dia upto 7.5 metres long is inclusive in the rate quoted. (ii) The earthing point shall be redone if the earth resistanace is found to be unsatisfactory at no extra cost to the Deptt by the contractor. amount of Sch ‘A’ Part-III carried over to BOQ under Srl item No. 1.03 S&F Brass chromium plated shower rose 125mm size and fixing to steel pipe or union, complete all as specified and directed. M&L PVC connection 15mm size with PTMT nuts of length 450mm, complete, all as specified and directed. M&L Ball brass valves 20mm bore, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, complete, all as specified and directed. M&L Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both ends for iron pipe and fixed, complete, all as specified and directed. S&F Health Faucet (ABS body) Mild Steel chromium plated suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connections and fixed in position complete, all as specified and directed. M&L Gun-metal, globe or gate valves 15mm bore, with iron wheel head, screwed both ends for iron pipe and fixed, complete, all as specified and directed. S&F Brass CP wall mixer 15mm bore for mixing hot & cold water screwed down for iron pipe and fixed, complete all as specified and directed. S&F Steel water tubing of nominal bore 20 mm, medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.), complete, all as specified and directed. S&F bib taps 15mm bore, fancy type, cast copper alloy chromium plated with crutch or butterfly handle screwed down for iron pipe or for brass ferrule and fixed , complete, all as specified and directed. S&F stop valve/angle valve 15 mm bore, fancy type chromium plated cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified. S&F Steel water tubing of nominal bore 15 mm, medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.), complete, all as specified and directed. S&F Steel water tubing of nominal bore 25 mm, medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.), complete, all as specified and directed. S&F brass CP mixer WHB for mixing hot and cold water screwed down for iron pipe and fixed in repairs for 15mm dia of pipe. 1 2 3 4 5 6 7 8 9 10 11 12 Supply only integral water proofing compound conforming to latest IS specifications. M&L Precast cement concrete 1:2:4 type B-1 (20mm graded aggregate) but in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:6, complete, all as specified and directed. TMT bars 6 to 8mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9mm dia, complete, all as specified and directed. Ref Drawings Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and directed. Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for manhole, sewage line, not exc 10 Sqm on Plan etc including getting out in any type of soil, complete all as specified and directed. M&L 15 mm thick rendering on fair faces of brick/concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement, complete, all as specified and directed. Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed. M&L for cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregates as in foundation, filling and mass concrete, complete, all as specified and directed. M&L concrete bed to drain pipes of bore 150mm including packing under,and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate including necessary shuttering and supports, complete, all as specified and directed. M&L Salt glazed stone ware drain pipes of internal diameter 150 mm grade 'A' laid in trenches and jointed , complete, all as specified and directed. M&L Brick work with sub class 'B' bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:4, complete, all as specified and directed. M&L Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregates as in copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form works, complete, all as specified and directed. Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed. M&L providing cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregates as in surface channels and drains, complete, all as specified and directed. M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc, complete, all as specified and directed. Note: INNER GIRTH ONLY MEASURED Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for foundation or for shafts , wells cesspits, manhole, Pier holes n.exc 10 Sqm on plan and n.exc 1.5m in depth, getting out in any type of soil, complete all as specified and directed. M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregates as stayl/foundation including necessary Cum form work and fair finish to sh exposed surface without using cement complete all as specified and directed All as per item No. 7 here-in before but depth exceeding 1.5 mir and not exceeding 3 mtr. Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and directed. Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed. Supply and lay sub class "B" bumt bricks, as in cable protection, taid length of brick perpendicular to Per length of cable complete all as specified M&L for sand coushing to under ground cable in trenches including spreading and consolidation in layers of 8 cm thick before laying the cable and 15 cm thick after laying the cable and punned down to form a bed, complete all as specified and directed. Note:- Payment purpose punned thickness shall be measured. Excavation in trenches n exc. 1.5 mtr wide and nexc 1.5 mir deep for foundations of poles/stays/cable etc not exc 10 Sqm area on plan and getting out in soft/loose Hard/Dense soil complete all as specifed and as directed by Engineer-in-Charge. M&L for PCC (1:4:6) type D-2 using 40mm graded stone aggregates as in foundation and sides of poles & PCC, blocks etc including necessary form work complete all as specified Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire RM armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 2 core complete all as specified and directed. Make:- Havells/Grandlay/KEI/Polycab/Finolex/L&T/HPL Supply, fix and erection of steel tubular swaged poles complete with cast iron base plate 8mm thick welded with pole, finial taper plug, bolts,nuts and screws as specified type 410 SP-31, 09 meter long, providing synthetic enamel aluminium paint over one coat of red oxide and black and white strips with synthetic enamel paint 30 cm each alternatively upto 1.5 mtr including 2 bands of radium tape of 2' width green & red colour above the coping of pole starting with black strip and painting with bituminous panit internally and externally portion embedded in PCC complete all as specified and directed Note (i) Earth work and PCC shall be measured and paid seperately Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast Each 6 aluminum housing and heat resistant complete with electronic driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified Supply, laying and testing cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire RM armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50.0 sq mm 3.5 core complete all as specified and directed. Make:- Havells/Grandlay/KEI/Polycab/Finolex/L&T/HPL & L Earthing for poles and other machinery/eqpt using Gl strip as earth lead and MS galvanized steel Each earth plate electrode 600x600x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep Set below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to galvanized iron strips 32x6mm with Gl pipe, nuts, bolts and washers complete upto and including test point made out of 40x3mm GI flat, PCC pit of required size in PCC 1:2:4 type B1 and RCC cover with frame, charcoal, common salt 15 cm all around the earth plate, watering pipe 20 mm medium grade galvanized and 40mm dia Gl pipe Medium grade for Gl strip protection with funnel complete all as specified and directed as shown in electrical plate No 3 of SSR Part-1 2009. Note: (i) Gl strip 32 x 6 mm and Gl protection pipe 40 mm dia upto 7.5 metres long is inclusive in the rate quoted. (ii) The earthing point shall be redone if the earth resistanace is found to be unsatisfactory at no extra cost to the Deptt by the contractor. Earthing complete with galvanized steel plate elecrode of size 60 cm x 60cm x 6.0 mm thick burried Each directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth Set plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and common salt, earth lead GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanised iron with thimbles. The other end of Gl earth wire is connected to main switch board and protected by medium grade Gl pipe of 15 mm bore. provision of 20 mm bore medium grade Gl pipe for watering including Gl funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. Cement concrete chamber of PCC 1:3:6) type C-2using 40 mm graded stone aggregates. The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover cement conrete (1:2:4) type B-1 using 20 mm graded stone aggregate and MS angle iron 50 x 50 x 6 mm frame including two coats of painting over a red oxide to exposed steel surfaces. excavation in soft/loose soil, returning filling in and removal of surplus soil to a distance of 50 mm as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2009). Note: (i) Gl earth lead 4.0 mm dia and Gl protection pipe 15 mm dia upto 7.5 metres long is inclusive in the rate quoted. (ii) The earthing point shall be redone if the earth resistanace is found be unsatisfactory at no extra cost to the Deptt by the contractor. Supply and fixing galvanised steel tube, light grade laid along the pole of size 40 mm bore for protection RM of cable including clamps made out of flat iron 25 mm x 4 mm size (02 Nos for each pole) for fixing arrangement including nuts and bolts of suitable size complete all as directed & F wiring in PVC conduit for circuit/submain wiring alongwith earth wire of size 2 x 1.5 Sqmm with 1 x RM 1.5 Sqmm earth wire in green color of FR PVC insulated copper conductor, single core cable through LT Pole for Street light connection from DB to Street light complete all as directed M&L for PCC (1:2:4) type B-2 using (20mm) graded stone aggregates as in PCC coping of poles or for stays complete all as specified. Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep including getting out in soft or loose soil, complete all as specified and directed. Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and directed. Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed. Supply and laying of steel water tubing of nominal bore 50 mm, medium grade galvanised with all fittings including short lengths, laid in trenches complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.), complete, all as specified and directed. Supply and laying of steel water tubing of nominal bore 25 mm, medium grade galvanised with all fittings including short lengths, laid in trenches complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.), complete, all as specified and directed. S&F gun metal globe or gate valves, with iron wheel head screwed both ends for iron pipe of 20mm bore and fixed, complete, all as specified and directed. Cutting and screwing existing steel tubing of size 50mm dia for alterations or lengthening screw on pipe to form connector and done in position without taking down, complete, all as specified and directed. Supply and laying of steel water tubing of nominal bore 20 mm, medium grade galvanised with all fittings including short lengths, laid in trenches complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.), complete, all as specified and directed. S&F gun metal globe or gate valves, with iron wheel head screwed both ends for iron pipe of 50mm bore and fixed, complete, all as specified and directed. 1 2 Surface excavation in any type of soil, n.exc 30cm deep and averaging 15cm deep and getting out, complete all as specified and directed. Removing surplus excavated material to a distance n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed. M&L for plain Cement concrete 75mm thick type E- 2, 1:5:10 (40mm graded aggregate) as in levelling course of sub floors, sub base, floors and paving etccomplete all as specified and directed. M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment etc complete all as specified and directed by Engr-in-Charge. M&L for 25mm thick sand filling under floors or in foundation including watering and consolidation all as specified and directed by Engr-in-Charge Removing excavated material n exc 50m deposting where directed at a level n exc 1.5m above the starting point. M&L for plain Cement concrete type B1, 1:2:4 (20mm graded aggregate) as in roof kerbs or mud stops , slightly rounded or chamfered angles and including necessary form work complete all as specified and directed. M&L for surface and excavation not exceeding 30cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified and directed.
|