Bids Are Invited For Procurement Of Measuring Instruments Total Quantity : 140; 1 FTP GS70-001-01183 Temperature controller, Make: Masibus, LC5296AT-C-U1-1-1-N Input: All thermocouple, RTDs and analog Output: On/Off relay and analog 12 2 FTP GS70-001-01184 Temperature controller, Make: Masibus, LC5296H-X-U2-1-N-5 Input: All thermocouple, RTDs and 4 to 20 mA Retransmission output: 4 to 20 mA and alarm relays 6 3 FTP GS70-001-01118 Ego/Elecon capillary Thermostat , adjutstable dial Range: 50 to 300 deg 20 4 FTP ES50-087-00444 LED volt-amp meter, 3Ø, 48X48mm, Make :Selec - MVA593 6 5 FTP ES50-087-00445 LCD Voltmeter, 3Ø, 72x72mm, Make :Selec - MV2307 6 6 FTP ES50-087-00446 LED Ammeter, 1Ø, 48X96mm, Make :Selec - MA12-CE 6 7 FTP ES50-087-00447 Multifunction Meter Make Selec- MFM383A 8 8 FTP ES50-087-00448 DC Volt meter digital, Range 0 to 200VDC ,Make : Meco 8 9 FTP ES50-087-00449 DC Amp Meter digital (60 mv Shunt to 7.5kA) , Make : Meco 8 10 FTP ES50-087-00450 DC Amp Meter digital (75 mv Shunt to 1000A), Make : Meco 8 11 FTP GS70-001-01185 RTD Assembly: PT 100 simplex 3, complete with 6 mm OD outer sheath of SS 316, terminal block, cast aluminium head and 1/2" BSP (M) adjustable SS bush for process connection. Length below head 400 mm. RTD insertion length must be adjustable with help of adjustable compression fitting. Supplied with fabricated SS 316 thermowell 10 mm OD x 8 mm ID with SS bush having process connection threads 1/2" BSP(M) and 1/2” BSP (F) for RTD entry. Thermowell Length should be suitable to RTD. Thermowell and RTD must be supplied separate. 12 12 FTP GS70-001-01186 RTD Assembly: PT 100 simplex 3 wire complete with 6 mm OD, outer sheath of SS 316, terminal block, cast aluminium head and1/2" BSP (M) SS bush for process connection. Length below head suitable to following thermowell. Supplied with fabricated SS 316 thermowell 10 mm OD x 8 mmID with SS bush having process connection threads 1/2" BSP(M) and 1/2” BSP (F) for RTD entry. Thermowell insertion Length below thread should be 60mm. Thermowell and RTD must be supplied separate. 25 13 FTP GS70-001-01187 RTD Assembly: PT 100 simplex 3 complete with 6 mm OD outer sheath of SS 316, terminal block, cast aluminium head and 1/4" BSP (M) SS bush fixed just below head. Length below head 200 mm. Supplied with fabricated SS 316 thermowell 14 mm OD x 10 mm ID with SS bush having process connection threads 1" BSP(M) and 1/4” BSP (F) for RTD entry. Thermowell Length should be suitable to RTD. Thermowell and RTD must be supplied separate. 3 14 FTP GS70-001-01188 RTD Assembly: PT 100 simplex 3 wire, complete with 6 mm OD outer sheath of SS 316, terminal block, cast aluminium head and 1/4" BSP (M) SS bush fixed just below head. Length below head 150 mm. Suppled with fabricated SS 316 thermowell 14 mm OD x 10 mmID with SS bush having process connection threads 1" BSP(M) and 1/4” BSP (F) for RTD entry. Thermowell Length should be suitable to RTD. Thermowell and 4 RTD must be supplied separate. 15 FTP GS70-001-01189 Head Mounted Temperature Transmitter Input : Pt – 100,3 Wire,Simplex Range : 0 – 400 °C (Others Programmable) Output : 4 - 20 mA Power Supply : 24 VDC Mounting : Head Mounted 8
|