Portable Microprocessed Digital Turbidimeter, With Nephelometric Measuring Principle, Reading Range From 0 To 1,000 Ntu, Minimum Resolution Of 0.01 Ntu And Accuracy Of Or - 1 Percent Of The Reading. You Must Use A Light Source Compatible With The Epa 180.1 Method (Eg: Tungsten Filament), With A Minimum Useful Life Of More Than 100,000 Readings. It Must Allow Multipoint Calibration, Covering The Entire Measuring Range. Minimum Internal Storage Capacity Of 200 Readings, Containing Information On Date, Time, Operator And Sample Identification, Reading Mode, Sample Number, Calibration Status And Results Obtained. It Must Allow Data Transfer To A Computer, Have Password Access Control And Fully Comply With The Epa Method 180.1. Operated By Alkaline Batteries Or Rechargeable Batteries, Accompanied By A Bivolt Power Supply. Supplied With Cuvette Kit, Primary Calibration Standards, Battery And Other Accessories Necessary For Full Operation. It Must Have A Minimum Warranty Of 2 (Two) Years, As Well As A Quality Certificate And A Calibration Certificate With Metrological Traceability. Minimum Standard Indicative Of Quality Or Similar, Being Compatible With Equipment From The Brands Hanna, Hach Or Similar, As Long As The Technical Specifications Are Fully Met., Thermal Box Capacity Of Approximately 6 (Six) Liters. Internal And External Part In Polypropylene, Lid In Polyethylene, Thermal Insulation In Expanded Polystyrene. Minimum Standard Indicative Of Quality Or Similar: Incoterm., Round Glass Cuvette, 25 Mm, With Lid, Capacity 10 Ml, Diameter 25 Mm, Compatible With Lamotte - Smart 3 Equipment. Material: Transparent Glass, Optical Or High Purity Borosilicate; Shape: Cylindrical/Round; External Diameter: 25 Mm. Usable Capacity: 10 Ml, With Visible Graduation Or Marking; Accessories: Comes With A Resistant Plastic Or Polyethylene Cover; Calibrated Cuvettes For Laboratory Use; Minimum Required Compatibility: Lamotte Equipment - Smart 3; Quality Indicative Standard: Lamotte Or Technical Equivalent. Different Brands Will Be Accepted, Provided That Technical Compatibility With The Lamotte Smart 3 Equipment Is Proven Through A Technical Catalogue, Sample Or Manufacturers Declaration. Box With At Least 3 Units., Reagent Kit For Iron Analysis, Compatible Dr 3900 - Hach, With At Least 100 Tests. Range Up To 1, 800 Mg/L. Minimum Validity On Delivery Of 12 Months. The Following Must Be Delivered Together With The Product: Product Quality Control Certificate; And Fispq. Minimum Standard Indicative Of Quality Or Similar: Hach, 12/23/2025 - 10:24:43
|