Color Doppler Ultrasound For General Use.: Minimum Technical Specification: High Resolution Digital System With At Least 4,000,000 Channels, Capable Of Performing Abdominal, Gynecological, Obstetric, 4D Obstetric, Breast, Small Parts, Skeletal Muscle, Vascular, Cardiology (Adult, Pediatric And Transesophageal) And Others, With The Following Minimum Technical Characteristics Transportable System, Mounted On Castors With Braking System, Possibility Of Viewing Images In Modes B, M, Color Doppler, Pulsed Doppler, Continuous Doppler, Tissue Doppler, Power Doppler (Angio), Directional Power Doppler And Hprf. The Basic Image Modes B, M And Pulsed Doppler Must Allow Colorization, That Is, Changing The Gray Scale To Colored Scales. High-Resolution Lcd Or Led Monitor With At Least 21 (Twenty-One Inches) With Fully Articulated Arm, Retractable And Backlit Alphanumeric Keyboard, At Least 04 (Four) Active Ports For Connecting 04 Simultaneous Transducers, Selectable Via The Panel, Without Considering The Pen Type Connector For Blind Doppler (Pedoff), Harmonic Software Inverted Pulse Tissue Compatible With All Transducers To Provide Better Image Resolution, Interlaced Beam Image Spatial Compositing Software. Software For Qualitative And Quantitative Analysis Of Tissue Elasticity Via Strain Elastography Software For Automatic Calculation Of Obstetric Measurements (Bpd/Hc/Fl/Ac/Ofd), Generating Efficiency And Accuracy, Optimizing Exam Performance Time. Software For Automatic Assessment Of Hepatic Steatosis, Through Comparison Of The Echogenicity Of The Liver With The Renal Cortex, In B Mode Tracking With Generation I, Computed Tomography (16 Channels 32 Cuts): 16 Channel Helical Computed Tomography, With Solid State Detector With, At Minimum, 16 Physical Rows And That Performs At Least 32 Cuts Per Rotation Description: I. Gantry: 1. Minimum Gantry Opening: 65 Cm. 2. Minimum Digital Angulation Range: +/- 30. 3. Maximum Time For One Rotation (360): 0.8 Seconds 4. Movement Control Panel (Gantry And Table) On The Front. 5. Minimum Scannable Volumetric Length: 150 Cm. 6. Continuous Helical Acquisition Capacity: 100 Seconds. Ii. X-Ray Tube: 1. Minimum Nominal Heating Capacity Of The X-Ray Tube: 3.5 Mhu 2. Anode Thermal Cooling Rate Equal Or Greater Than 740 Khu/Minute, Iii. X-Ray Generator: 1. High Frequency Generator, With At Least 30 Kw Of Power Or Higher 2. Selectable Value For Ma: 10 300 Ma 3. Minimum Voltage Range: 80 140 Kv. 4. Supply Voltage: 380Vac 60 Hz. Iv. Patient Table: 1. Must Support A Load Of 200 Kg Or Greater. 2. Vertical Elevation Movement Between 50 And 90 Cm 3. Horizontal Displacement With Gantry Control, Reproducibility Accuracy Of Approximately 0.25Mm, V. Image Acquisition And Processing System: 1. General Characteristics: A. Generation Of 32 Sequential Cuts Per Rotation (360). B. Minimum Cutting Thickness Less Than Or Equal To 0.8 Mm. C. Reconstruction Rate: Minimum 15 Images Per Second On 512 X 512 Matrix D. 1024 X 1024 View Matrix. E.
|