|
INSTALLATION OF LED SIGNAGE BOARD AT C.R. AVENUE, VIVEKANANDA ROAD IN WARD NO.26, BR-IV, K.M.C. Outdoor Lighting Installation, Steel Tubular Pole, M.S. Pipe, G.I. Pipe, Pole Cap Etc Supplying Of Swaged Steel Tubular Pole As Per Is 2713, Pt. Ii, 1980 For Following Designation And Of Following Dimensions.(Outside Dia & Thickness Are Given In Annexture -1)G) 410 Sp - 21 ; 8.5 Mtr., 129.00 Kg , Outdoor Lighting Installation, Steel Tubular Pole/ M.S Pipe/ G.I. Pipe, Pole Cap Etc. Supplying & Fixing Of G.I Pole Cap For Suitable Size , Painting Steel Tubular Pole Including Projected Arm Bracket With One Coat Of Red Oxide Primer And Two Coats With.Silverlac Ai.Paint (Scraping Where Necessary). Pole Painting Upto 5Mtr. Pole , Outdoor Lighting Installation, Steel Tubular Pole/ M.S Pipe/ G.I. Pipe, Pole Cap Etc. Supplying & Fixing Of M.S. Sole Plate (450X450x6m) At The Bottom Of Pole. , Supplying Of 1.1 Kv. Grade Pvc Insulated Conductor Of Following Cables (Make: Polycab/ Gloster/Havells/):Size In Sq. Mm, No & Dia. Of Wire In Mm , No Of Core - 6 1/2.80 2 , Schedule Of Rates For Earthing Installations.Earthing Installation ... With Pipe Electrode.Earthing With 50 Mm Dia Gi Pipe 3.64 Mm Thick X 3.04 Mts. Long And 1 X 4 Swg Gi (Hot Dip) Wire (4 Mts. Long), 13 Mm Dia X 80 Mm Long Gi Bolts, Double Nuts, Double Washers Incl. S & F 15 Mm Dia Gi Pipe Protection (1 Mts. Long) To Be Filled With Bitumen Partly Under The Ground Level And Partly Above Ground Level Driven To An Average Depth Of 3.65 Mts. Below The Ground Level As Below:(A)By Isi Medium Gi Pipe. , A N N E X U R E - I Basic Rate Of Materials: (All Rates Of Materials From K-1 To K-14 Are Excluding Vat) 124. 40Mm Gi Pipe (Isi-Medium) , A N N E X U R E - I Basic Rate Of Materials: (All Rates Of Materials From K-1 To K-14 Are Excluding Vat) 184. Ms Clamp (380X40x6mm) , Laying Through Underground Trech.(A)Laying Of One No. Cable Upto 35 Sqmm In Underground Trench 460 Mm Wide X 760 Mm Average Depth, With Brick Protection On The Top Of The Cable With 8 (Eight) Nos. Bricks Per Metre, Including Filling The Space Between The Brick & Cable And Also The Trench With Shifted Soil, Leveling Up And Restoring Surface Duly Rammed , Laying Through Rcc/Hume/Gi Pipe.(A)Laying Only Cable Upto 50 Sqmm Through Existing Rcc/Hume/ Gi Pipe/Open Masonary Trench For Single, 2, 3, 3... & 4 Core , Building Works (F) Structural Steel Works, Grills, Gates Etc. B. Repairing 2. Welding In M.S. Structural Work With Gas Or Electric: (A) Tack Weld , Fixing Only Tpn Mcbdb In Sheet Steel Enclosure (4 To 12 Way) On Flat Iron Frame On Wall 415V Tp/Tpn , Schedule Of Rates For Oh Line Installation (Lt Distribution).Erection Of Poles.Erection Of Single Steel Tubular Pole Of Length As Given Below With/Without Sole Plate & Cap Etc. In Cement Concrete Foundation (Proportion And Dimension Indicated Below), Having 600X600x150 Mm Thick Cement Concrete (4:2:1) Base Block Below Sole Plate/Pole With Hard Jhama Metal Including Cement Concrete (6:3:1) Muffing 0.30 Mts. Dia And 0.30 Mts. Above Ground Level Including 3 Mm Thick Neat Cemented Finish And Gi Earth Bolt After Making Drilled Holes Etc. On Pole & Carriage Of Pole Upto 1.6 Km From Store To Work(Site Including Filling Up The Excavated Earth Pit With Shifted Soil And Ramming Properlyupto 9.0 Mtr. Size 0.6X0.6X1.70 Mts , Supplying & Delivery Of Sintex Frp White Waterproof Type Looping Cable Box Size 300X200x125 Mm Deep, 4 Mm Thick , Having Insulation Resistance Greater Than 200 Mega Ohm, Ip66; Comprising Of One No Spmcb, 4 Nos. Terminal Connector Having Voltage Grade Of 1.1 Kv, One Compression Type Brass Cable Gland For Upto 4 Core 16 Sqmm Pvc/A Cable As Per Rate Obtained From Gem Portal , Supply And Installation Of Polyvinylidence Fluoride Coated Aluminium Composite Panel Board (3Mm) Of Aludecor/Alstone Size (As Per Drawing) To Be Made Such A Manner That It Can Be Opened Towards Up Direction For Taking Maintenance (Usor (M&E) , 2022 Of Irigation & Water Dept. , Govt. Of Wb (Page-127 , Item 5.3L.1) , S & F Acrylic Letter Scripted In English/Bengali Size And Matter Of Letter As Per Approved Drawing By Eic, Front Side Of The Letter To Be Made 6Mm Thick Imported (White 0.40 Uv Stabilized Excellent To Self Display. Make-Acast, Mitsubishi, All Letter Will Be Raised Minimum 2? To Be Fixed By Special Type Of Solution. (Total Sq. Meter Ofeach Letter Is To Be Measused Based On Its Front Surface Area) (Usor (M&E) , 2022 Of Irigation & Water Dept. , Govt. Of Wb ) (Page-127 , Item 5.3L.2) , S& F Led Lamp Incl . Best Quality Led Lighting Arrangement To Be Fixed By Proper Arrangement With Complete Connection (1 Module Contain 3 Nos Led , 0.5 Each (Usor (M&E) , 2022 Of Irigation & Water Dept. , Govt. Of Wb )(Page-127 , Item 5.3L.3) , S& F Water Proof Power Supply System Ip 65, Out Voltage :12V/24V Dc, 50/60 Hz Frequency, 108 To 305 Vac Power Supply 0.95 Power Factor For Led Lamp ( Make : Mean Well) 200 Watt, Model Elg 200 (Usor (M&E) , 2022 Of Irigation & Water Dept. , Govt. Of Wb )(Page-127 , Item 5.3L.4.4) , 26 Gauge Galvanizes Iron Sheet For Back Panel With One Coating Of White Paint , Make- Aarti/ Bansal/Jindal) (Usor (M&E) , 2022 Of Irigation & Water Dept. , Govt. Of Wb )(Page-127 , Item 5.3L.5) , S& F Led Lamp Incl . Best Quality Led Lighting Arrangement To Be Fixed By Proper Arrangement With Complete Connection (1 Module Contain 3 Nos Led , 0.5 Each (Usor (M&E) , 2022 Of Irigation & Water Dept. , Govt. Of Wb )(Page-127 , Item 5.3L.3) , Chimney Etc.(C). Additional Rate?(21)Supplying, Fitting & Fixing Upvc Pipes A- Type And Fittings Conforming To Is:13592-1992 With All Necessary Clamps Nails, Including Making Holes In Walls, Floor Etc. Cutting Trenches In Any Soil Through Masonry Concrete Structures Etc If Necessary And Mending Good Damages Including Joining With Jointing Materails (Spun Yarn, Valamoid/Bitumen/M-Seal Etc) Complete.A) Upvc Pipes:(Ii) 110 Mm. Dia. , Sub Total , Cgst 9% , Sgst 9% , Cess 1%
|