|
Tender For Special Repairs To Otn Accn Bldg No P 658 Of Army Ad Records Under Ge I Gos; 1 Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. 2 M & L for brick work with sub class B brick (old size) straight or curved on plan to any radius in half brick thick walls built in CM 1:4 to any radius complete all as specified and directed. 3 M & L for old size brick work with fly ash bricks straight or curved on plan exc 6m mean radius in CM 1:6completed all as specified and directed. 4 Taking down cement plaster any description on brick or stone walls or RCC roofs/ceiling etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. 5 M&L for rendering 15 mm thick on fair face of brick works in CM 1:6 finishedeven and smooth with out using extra cement complete all as specified and directed. 6 M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick or concrete surface of wall and finished even and smoothwith out using extra cementand mixed with water proofing compound @ 3% by weight of cement complete all as specified and directed.(Note: supply only of WPC shall be measured and paid for seperately) 7 M&L rendering 5 mm thick in cement mortar 1:3 on concrete surfaces of ceiling and finishing the surfaces even and smooth complete. 8 M&L for preparation of new plastered surfaces of walls or concrete and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. 9 M&L for preparation of old decorated surfaces of walls and apply two coats of white wash complete all as specified and directed 10 M&L for Complete Removal of existing treatment including preparation of old treated surface and applying Two coat of oil bound distemper over over a coat of primerincluding preparation all as specified and directed. 11 M&L for preparation of old distempered surfaces of walls and applying one coat of oil bound distemper on walls all as specified and directed. 12 M&L for preparation of old painted surfaces of wall and applying two coat of cement base paint over a coat of primer complete all as specified and as directed. 13 M&L for preparation of newly plastered surfaces of wall and applying two coat of cement base paint over a coat of primer complete all as specified and as directed. 14 M&L Preparation of Newly Plastered surfaces of Ceiling and applying Three coats of White Wash complete all as specified and directed. 15 M&L for Preparationof old surfaces of ceiling and applying two coats of white wash complete all as specified and directed. 16 Taking down chowkhat or frames n exc 1.50 Sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed 17 Taking down chowkhat or frames exc 1.50 Sqm and n exc 4 Sqm each with shutters (without taking off shutters from the frame)complete all as specified and directed 18 S&F Second class hard wood (Sal) plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. 19 S & F 35 mm thick second class hard wood rail and style plain, framed, factory made panelled shutters (Two panels) with lock rail and panel of 9 mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces. The size of rail and stiles are as per IS – 1003 (Part – I), kiln seasoned & chemically pressure treated complete all as specified and directed. 20 S&F Second class hard wood 30 mm thick factory made glazed and skeleton shutters, open rebated and prepared to receive glass,gauze etc with out sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,gauze etc, sizes of members of shutters as specified in SSR part I section 8 clause 8.24 (b) complete all as specified and directed. 21 S&F in repair Stainless steelwire cloth 0.36mm nominal dia of wire and average width of aperture 1.4 mm fixed with stainless steel wire staples or with necessary beads complete all as specified and directed. 22 S&F in repair 250 mm long aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloycomplete all as specified and directed. 23 Hacking out old broken glass (any thickness, size quality or description) form wooden frames or steel,Alu, concrete or brick surrounds glazed with oil putty or fixed with beads complete all as specified and directed. 24 S&F 3.0 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane, complete all as specified and directed. 25 S & F for solid PVC door frame of size 50x47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, supplied and fixing in opening as specified and shown on drawing made on section 8 of SSR 2010 Part-II complete all as specified anddirected 26 S & F factory made solid panel PVC door shutter 30 mm thick style consisting of frame made out of MS tube for top and bottom rails.MS frame shall be covered with heat moulded plain colour PVC “C” channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, S & F in the frame as per specifications and shown on drawing in section 8 of SSR-2010 Part-II complete all as specified anddirected 27 S&F in repair 100 mm long butt hinges extruded aluminium alloy with galvanised mild steel hinge pin anodised type B-21 complete all as specified and directed. 28 S&F in repair 150 mm size extruded aluminium alloy handles fabricated type anodised ofcomplete all as specified and directed. 29 S&F in repair 150 mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed. 30 S&F in repair floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor, over all length of cover plate 150 mm complete all as specified and directed. 31 M&L in repair 18/19 mm thickPrelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work incl taking down old cupboards etc. complete all as specified and directed. 32 S&F 6 mm thick teak wood liping 12 mm width prelaminated particle board fixed with screws complete all as specified and directed. 33 S & F in repair Continuous (piano) hinges, 40 mm width of mild steel, bright finish or electrogalvanisdcomplete all as specified and directed. 34 S&F in repair Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed. 35 Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. 36 S&F in repair Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165for complete all as specified and directed. 37 M&L for preparation of old painted surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply one coat of synthetic enamel paint complete all as specified and directed. 38 M&L for prepararion of old painted surfaces of steel over 10 cm width or girth and applying two coats of synthetic enamel paint on surfaces complete all as specified and directed. 39 M&L for preparation of new steel or iron surfaces Surfacesover 10cm in width or girth and applying two coats of synthatic enamel paint over a coat of red oxide zinc chrome primer . 40 S&F Powder coated Aluminium sliding glazed windows with three track and three shutter slidingwith following specifications and making good the adjacent surfaces complete all as specified and directed.(a) Three way track for sliding shutters of Cross section 92.0 mm x29.50 mm x1.2 mm thick.(c) Sliding shutters frameof Cross section 41 mm x20 mm x1.2 mm thick(d) 5.5 mm thick plain glass of approved make(e) IDPE rubber gasket for fixing of glass.(f) Locking cleats per shutter-01 Nos.(g) Sliding rollers per shutter-01 Nos.(h) Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.56mm for shutters-01 Nos(i) Fixing screws for frame with wall per window-08 Nos 41 S&F 7 mm thick aluminium grills of god quality surrounded by aluminium C channel with mesh size 75 X 75mm complete all as specified and directed. 42 Dismanting of existing sunken floor treatment incl plaster and removal of all debris and M&L for water proofing treatment on existing sunken floor/wall with the following specification and sequence complete all as specified and directed by Engr-In-Chrg (a) Cleaning the internal surface areas thoroughly so that they are free of all contaminants like dirt and laitance & to remove all the loose materials by various mechanical/manual means.(b) Removal of all surface Imperfections, protrusions ,loose concrete & filling of cracks using Dr Fixit Pidicrete URP Modified Mortar in the ratio Cement: Sand (1:4) and 5% by weight of cement. (c) Providing and making fillets at the junction of the walls and the slabs using cement mortar of 1:4 mix admixed with 5 % of DR. FIXIT URP by weight of cement. (d) Applying two coats of elastomeric compound viz beck bond WPC-30/Master coat IRC over one coat on neat primer i.e. Super latex of Dr Fixit/Master bond of Conchem. (e) Laying protection plaster 15mm, in CM 1:4 admixed with STP/DrFixit diproof LW@200 ml per bag of cement. 43 Demolition of cement concrete unreinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed. 44 M&L for PCC 1:5:10 type E-2 using 40mm graded stone aggregate as infilling of sunken floor etc and mass concrete complete all as specified and directed. 45 M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring 25 mm thick surface finished even andrough to receive the topping layer complete all as specified and directed. 46 Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing)and removing rubbish off the premises complete all as specified and directed. 47 M&L Vitrified Ceramic tiles 10 mm thick (square/ rectagular) dark/light colourshade polished,area of each tilesnot exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match as in floors over 20mm thick screed bed in CM 1:6 complete all as specified and directed. 48 M&L for machine cutkota stone slab flooring 20mm thick over cement screedbase laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 20mm thick screed bed in CM 1:6 complete all as specified and as directed. 49 M&L for machine cutkota stone slab 20mm thick as in dado, riser, steps and the likes laid over and including rendering 15mm thick in CM 1:4 for bedding layer complete all as specified and as directed. 50 M&L for Non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 20 mm thick screed bed in cement mortor 1:6 complete all as specified and directed. 51 M&Lfor glazed ceramic coloured tiles 300 x 450 x 7 mm thick on vertical surface such as dado /skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment. 52 M&L for RCC 1:2:4 (Nominal mix) type B-1 as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed 53 Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. 54 S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips 55 M&L for 20 mm thick granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and incl 15 mm thick screed bed in cement mortor 1:4 and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. 56 Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations 57 Taking up & down GI steel tubing & connections including cleaning for refixing or removal to store for 15mm bore of pipe complete all as specified and directed. 58 Taking up & down GI steel tubing & connections including cleaning for refixing or removal to store 20mm bore of pipe complete all as specified and directed. 59 Taking up & down GI steel tubing & connections including cleaning for refixing or removal to store 25mm bore of pipe complete all as specified and directed. 60 Supplying and laying of 15mm bore dia, CPVC pipes SDR 11,plain CPVC SDR 11 fittings and brass fittings as required fixed on walls/ceiling or laid in floors, etc, complete all as specified and directed. 61 Supplying and laying of 20mm bore dia, CPVC pipes SDR 11 & plain CPVC SDR 11 fittings,and brass fittings as requiredfixed on walls/ceiling or laid in floors, etc, complete all as specified and directed. 62 Supplying and laying of25mm bore dia, CPVC pipes SDR 11 & plain CPVC SDR 11 fittings,and brass fittings as required fixed on walls/ceiling or laid in floors, etc, complete all as specified and directed. 63 Cutting chases in brick walls, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete. 64 S&F in repair bib tap fancy type cast copper alloy chromium plated with crutch or butterfly handle fixed to 15 mm dia GI tube/CPVC pipe all as specified and directed. 65 S&F in repair 15 mmfancy type pillar taps chromium plated cast copper alloy with capstan heads screwed down high pressure with or without lettered ‘Hot’ or ‘cold’ with long screwed shanks and fly nuts screwed for iron/CPVC pipe and fixed complete as directed . 66 S&F in repair 15 mm fancy type stop valve/angle valve cast copper alloy chromium plated screwed high pressure with crutch or butter fly handle screwed both ends for iron or union and fixed to 15 mm GI tube ,complete all as specified and directed . 67 S&F in repair 25mm dia ball Brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipes or brass ferrule and fixed as in PVC Service tanks,complete all as specified and directed . 68 S & F in repairs 25mm bore gun metal gate valves with iron wheel head screwed both ends for iron pipe and fixed ,complete all as specified and directed . 69 S&F in repairs PVC connection 15mm size with PTMT nuts, of 450mm length complete all as specified and directed. 70 S & F in repair vitreous china counter wash basin oval type size 560x400x205 mm, white, fixed on Granite/Marble or other appropriate top coloured including chromium plated waste coupling, PVC connection and waste pipe complete all as specified. 71 S&F in repairs viterious china squatting pan orissa pattern size 580x440mm white integal foot rest including concrete bedding & including P or S trap 100mm,complete all as specified and directed . 72 S & F in repairs,vitreous china wash down water closet pan (pedestal pattern), white, incl P or S trap and plastic water closet seat cover, black, closed pattern with flat bottom and cover & MS chromium plated or aluminised hinging device ,complete all as specified and directed . 73 S & F in repairs Vitreous China urinals, bowl type flat back size of 465 x 355 x 265 mm white (minimum)with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement including PVC waste pipe etc complete all as sapecified and directed. 74 S&F in repair PVC low level flushing cistern (white) 10 Ltrs capacity with inlet, ball valve, float and handleinternal fitting, push button operated type with and including brackets etc complete. 75 S&F in repair health faucet with flex pipe and hand shover ,the length of hose 1.50 mtr fitted to the tap.complete all as specified 76 S & F in repairs Brass chromium plated shower rose 125mm size complete all as specified and directed 77 S&F PVC (SWR) floor trap 75 mm dia palin with gratingincluding jointing with solvent cement with waste hole of PTMT Minimum weight 40 gms ,complete all as specified and directed. 78 S&F in repair CP brass towel rail `D’ type 60Cm long fixed to wall ,complete all as specified and directed. 79 M&L 32mm dia bore Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc.with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed as in repairs 80 S&F Bevelled edge mirror of size 600x450mm of selected quality glass 4mm thick mounted on 6mm thick AC building board or commercial ply wood and fixed with wooden plugs with chromium plated screws including taking down existing mirror . 81 Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete,PVC ) set in cement mortor for any size & type complete all as specified and directed. 82 M&L for PVC (SWR) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors of 75 mm bore of pipe etc complete all as specified and directed. 83 M&L for PVC (SWR) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors of 110 mm bore of pipe etc complete all as specified and directed. 84 M&L for PVC (SWR) pipessingle socketed, in any length with rubber ring joints, fixed to walls of 75 mm bore of pipe etc complete all as specified and directed. 85 M&L for PVC (SWR) pipessingle socketed, in any length with rubber ring joints,fixed to walls of 110 mm bore of pipe etc complete all as specified and directed. 86 S&F PVC (SWR) bends any radius of 75 mm borewith outaccess door complete all as specified and directed. 87 S&F PVC (SWR) bends any radius of 110 mm borewith outaccess door complete all as specified and directed. 88 S&F PVC (SWR) bends any radius of 75 mm borewithaccess door complete all as specified and directed. 89 S&F PVC (SWR) bends any radius of 110 mm borewithaccess door complete all as specified and directed. 90 S&F PVC (SWR) vent cowl 75 mm bore complete all as specified and directed. 91 S&F PVC (SWR) vent cowl 100 mm bore complete all as specified and directed. 92 Dismantling PVC water tanks exc 500 ltr but not exc 1000 ltr capacity and removing to store complete all as specified and directed. 93 S&F 1000 ltr capacity Rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) hoisted and fixed in position all as specified complete 94 Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power)complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings i.e removingmaterials to store forkeeping in safe custody or for taking credit (credit for above items should be made for conditions separately )and including making good the disturbed surfaces to match with existing surface and colour shade with proper puttyfor smooth finishing without andulations complete all as specified and directed.( Note:-All credit materials should be deposited in MES yard as available on work site the same materials should be issued to contractorthrough gate passas per schedule of credit materials againstcontract agreement). 95 Material and labour for cutting chasing,pinning ofbrick/ stone/concrete wallat any height wall cutting and chases for concealedwiring for 20/25 mm PVC conduit dia pipe,water tubing,etc and making good to facings where required and pointing in cement motor 1:3 to ends or edges of landigs,wall surfaces etc,cutting not exc 10 cm girth and including making good the disturbed surfaces to match with existing surface and colour shade with proper putty for smooth finishing with existing wall complete all as specified and directed 96 M&L for point wiring using approved colour coding incl providing circuit wiring with 1.5 sqmm PVC insulated, FRLSH type, ISI marked,conf to IS-694/1990 unsheathed,multistranded,single core, coppercable 1100 volts grade cablesdrawn throughPVCConduit 20/25 mm dia medium grade(MMS) at any height and all accessoriesare concealedinwalls / roofs / floors / ceiling etc. flush mounting modular MS boxmade out of 1.60mm thick suitable for modular top cover and framefor fixing of modular switches,sockets,fan regulators, blank plate etc andincluding 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with coppercable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade with necessary putty for smooth finishing complete all as specified and directedfor One light point controlled by one 10amps switch, one way 97 All as per item no. 96 but forOnefan point controlled by one switch 10 amps, and oneregulator. 98 All as per item no. 96 but for Oneexhaust fan point controlled by one switch 10 amps,one way 99 All as per item no. 96 but for One 5 pin 6 amps socket point controlled by one 10 amps switch on independent board . 100 All as per item no. 96 but for One 5 pin 10 amps socket point controlled by one 10 amps switch on same board . 101 All as per item no. 96 but for One light point controlled by two 2 way switches. 102 All as per item no. 96 but forpoint wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for One 6 pin 16/20amps socket outlet point controlled by one 16/20 amps switchon independent board. 103 All as per item no. 103 but forOne 6 pin 16/20 amps socket outlet point controlled by one 16/20 amps switch on same board. 104 All as per item no. 96 but for point wiring with 4.0 sqmm and earth conductor of size 4 sqmm complete all as specified and directed. 105 Supply & fixing modular type switch 10 Amps, single pole,1way,1 module,240V,AC, withISI Markedcomplete all as specified and directed. 106 Supply & fixing modular type switch 10 Amps ,2way,single pole,1 module,240V,AC,with ISI Markedcomplete all as specified and directed. 107 Supply & fixing modular type switch 16/20 Amps, single pole,1way,1 module,240V,withISI Marked complete all as specified and directed. 108 Supply & fixing modular type socket shuttered type 10 Amps, 2/3 Pin combined 2 module,240V,ACISI Marked complete all as specified and directed. 109 Supply & fixing modular type socket 16/20 Amps, 6 Pin combined shuttered socket 2 module,240V,ACISI Markedcomplete all as specified and directed 110 Supply & fixing modular type step fan speed regulator 120W, 2 module,230volts,AC, 360 degree rotation 1 to 8 steps,ISI Markedcomplete all as specified and directed. 111 Supply & fix angle lamp holder latest model, insulated PVC out side body and brass inside holder with back plate for batten fittings/bulbscomplete all asspecified and directed. 112 Supply & fix ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed 113 Supply & fixdecorative box type 20 watt light fitting,blue coloured end caps, pre-wired and including providing single or double sideLED tube rod 20 watt-01 No including PVC/Wooden round/square block -02 Nosand connected with LED fitting to ceiling roseand including removing old unserviceable fitting complete all as specified and directed. 114 Supply and fixing 20 watts LEDmirror smart light fitting one feet long,contemporary design of mirror light complete decorative LED lighting with extruded polycarbonate, environmentalfriendly, energy efficient, easy to install,PC diffuser, high quality materials,pre-wired including providing PVC round/PVC square blocks-02 Nos and connected with LED fitting to ceiling rose terminal and incl removing old unserviceable fitting complete all as specified and directed. 115 Supply and fix LED secruity light fitting of capacity 60 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protectionwith 4/5 KV inbuilt surge protector and cable connection from ceiling rose/looping box/switch board/DBs to light fitting and testing and including removing of old unserviceable item complete all as specified and directed. 116 S & F Energy efficient and energy saving new generation 10 watts LED bulk head light fitting IP-65 luminaire with opel diffuser pre-wired ofluminaires including LED light driver and connected with LED fitting to ceiling rose terminaland incl removing old unserviceable fitting complete all as specified and directed. 117 Supply and fix GI bracket pipe of size 32 mm dia medium grade of 1.2 mtr long bent to shape suitable degree of bending as per site requirementwith hot or coldbending method of process for making the one end of GI pipe bracket suitable for fixing of any type street light fitting and shall be fixedonwall surfaces and including providingsuitable fabricate galvanised flat ironclamps of 30X6 mm thick-02 Nossuitable for fixing at any place/height with hole fastners,nuts,bolts & washers including grouting on wall etc and including removing of old unserviceable item complete all as specified and directed. 118 Supply & fixingand sheet metal enclosurewith acrylic door type, DD/AD ,415 volts AC,VTPNDB, 4 way,8+12 modules, flush mounting with 200amps copper busbar, 2 neutral/earth bars links and MCCB incomer,and MCB SPN/SP/TPNas outgoing and complete forIP43 DBs protection and includingremoving old unserviceable DBs and incl making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed. 119 Supply & fixing andsheet metal enclosure, with acrylic door type, double door, 240 volts AC,SPN,DB, 8 way, flush mounting with 100amps copper busbar,neutral bar,earth bar links and MCB incomer MCB SPN/DP and MCB SP as outgoingforIP 43& IP54 DBs protection nd includingremoving old unserviceable DBs and making good the disturbed surfaces to match with existing surface and colour shade acomplete all as specified and as directed. Make:-Legrand Cat No.5076 21 8 way or equivalent makein ABB/Havells 120 Supply & fix andsheet metal enclosure, with acrylic type double door, 240 volts AC,SPN,DB, 4/6 way, flush mounting with 100amps copper busbar,neutral bar,earth bar and MCB incomer,MCB SPN/DP,and MCB SP as outgoingforIP 43& IP54 DBs protection nd includingremoving old unserviceable DBs making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed. 121 Supply & fixMCB SP 6 to 32 Amps 10 KA,C series,AC,240Volts,50Hz , ISI marked and including removing old unsv items complete all as specified and directed. 122 Supply & fix and MCB SPN 32 to40 Amps 10 KA,C series,AC,240Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed. 123 Supply & fix and MCB TPN 4063 Amps 10 KA,C series,AC,415Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed as approved by GE 124 M & L for sub main wiring complete in repairs with 4 run of 10 sqmm single core copper conductor (ISI marked)cable1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi strandedcolour coded cables drawn through and including rigid PVC conduit in concealed ISI marked medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv submain wiring making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Four run of 10 sqmm single core copper conductor cable and one run of 10 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. 125 M & L for sub main wiring complete with 2 run of 10 sqmm single core copper conductor (ISI marked)cable1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi strandedcolour coded cables drawn through and including rigid PVC conduit ISI marked medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv sub main wiring andmaking good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Two run of 10 sqmm single core copper conductor cable and one run of 10 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. 126 All as peritem No 125, but 2 run x 6 sqmm+1 run earth wire complete all as specified and directed. 127 All as per item No 125, but 2 run x 4 sqmm+1 run earth wire complete all as specified and directed. 128 Supply and fixMCCB,125 Amps,4 pole,415 Volts , 16/18KA thermal magnetic type with necessary lugs,thimbles, nuts bolts and washersand including removing old unserviceable itemcomplete all as specified and as directed. 129 Taking down old unserviceable ceilingfans of any type/sweep from work site and deposit to MES store yard Supply and fixingceiling fans complete with blades, down rods, and connected accessories, 230 V, 1400mm sweep,copper winding, antidust -dustproof painted type,high speed,down rod. Star rated with induction motor complete all as specified and directed. 130 Taking down old unserviceable exhaust fans of any type/sweep from work site and deposit to MES store yard Supply and fix new exhaust fan, turbo forcesteelbody AC single phase.230Volts of size 300 mm sweep with four bladesand including providing insect protection net frame , with louvers and frameincl writing MES No on exhaust fan with synthetic enamel paint complete all as specified and directedcomplete all as specified and directed. 131 Supply and fix air circulator heavy duty turbo force wall mounted,metal body type fan 230Volts single phase oscillating 450 mm sweep and all connected accessories and including providing hanging heavy duty GI plate/clamp, nuts, bolts and washers complete all as specified and directed. 132 Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 3.5 sqmm,3.5 core complete all as specified and directed. 133 Boaring holes horizontally under road without damaging the surface of road (minimum 1.0 Mtr bellow the road surface) with the help of GI tubing of any dia not exc 80mm dia for passing of UG cable all as specified and as directed. 134 Supply and filling in and speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed. 135 Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil complete all asspecified and directed. 136 Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed 137 Removing excavated soil not exc50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed 138 M & L for brick sub class B 250mm x 115mm x 0.75mm and laid in trenches as in protection of UG cablecomplete all as specified and directed. 139 Material & labour for GI pipe 50 mm light grade laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and directed. 140 Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipeof 15 mm diafrom earth electrode up to test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC/(PVC hevy duty cover) cover 1:2:4 type B1 of size 45X45X6CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required valueincluding removing old item completeall as specified and directed. 141 Supply and fixing of metal flush box 1/2 module, ISI marked,and suitable for existing type as per site requirement and including removing old unserviceable item from existing loaction complete all as specified and as directed. 142 Supply and fixing ofmetal/PVC flush box 3 module ,ISI marked, and suitable for existing type as per site requirement and including removing old unserviceable item from existing loaction complete all as specified and as directed. 143 Supply and fixing of metal/PVC flush box 4/5 module, ISI marked,and suitable for existing type as per site requirement and including removing old unserviceable item from existing loaction complete all as specified and as directed. 144 Supply and fixing of metal/PVC flush box 6 module,1.60mm thikness ,ISI marked and suitable for existing type as per site requirement and including removing old unserviceable item from existing loaction complete all as specified and as directed. 145 Supply and fixing of metal/PVC flush box 8 module,1.60mm thikness ,ISI marked and suitable for existing type as per site requirement and including removing old unserviceable item from existing loaction complete all as specified and as directed. 146 Supply and fixmodular white cover plate with frame 1 modulesuitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. 147 Supply and fixmodular white cover plate with frame 2 modulesuitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. 148 Supply and fixmodular white cover plate with frame 3 modulesuitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. 149 Supply and fixmodular white cover plate with frame 4 modulesuitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. 150 Supply and fixmodular white cover plate with frame 6 modulesuitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. 151 Supply and fixmodular white cover plate with frame 8 modulesuitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. 152 Material and labour for 3-layer PP-RPolypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc.ISI Marked IS-15801 lying in trenches/wallc/ceilings or in floors and necessary clamps, saddles etc complete of size outer dia 32-40 mm complete all as specified and directed. 153 Supply and fixing PPR gate valve(Brass insert) of dia 40 mm fixing at near to building on wall upto one meter height complete all as spfd and directed. 154 Making connections of PPR pipes distribution branches with PPR main of following sizes of 50 to75mm by providing and fixing tee including cutting and making fusion joint etc
|