Tender For Special Rep To Certain Bldgs At Tangdhar, Pathahiri And Panzgam Under The Aor Of Ge 874.; 1 Dismantling plain or corrugated steel sheeting any gauge thickness in roof covering/wall etc complete all as specified and directed. 2 S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with tapping screws complete all as specified and directed. 3 Pre-painted galvalume aluminium zinc coating GI based steel sheet 0.50mm thick,of any colour having tensile strength of 550 Mpa, profiled for ridge as in roof covering,fixed with self tapping screwscomplete all as specified and directed. 4 Demolition of cement concrete (Un-reinforced) in ground floors and paving n.exc 15 cm thickness below or above ground level complete all as specified and directed. 5 Dismantling wall and ceiling board of any description including cover fillets complete all as specified and directed. 6 M&L for 6mm thick veneered decorative plywood (05 Nos of ply) grade-01 (with BWR resin) with decorative face veneers on the one face fixed with nails to timber frame works fixed in wall/linings complete all as specified and directed. 7 M&L for 6mm thick veneered decorative plywood (05 Nos of ply) grade-01 (with BWR resin) with decorative face veneers on the one face fixed with nails to timber frame works fixed in ceiling etc complete all as specified and directed. 8 S&F 2nd class soft wood 10 to 12 mm thick wall panelling of good quality wood plained one side and edges tonged and grooved or rebated other side and dovetailed joints, chamfered both sides fixed to frame work with secret nailed as in wall /ceiling panelling including cornice and beading as required and applying two coats of varnish over a filler coat of thin varnish after preparation of the surface, complete all as specified and directed.Note:Frame work shall be measured and paid separately. 9 S&F second classhardwood plain fillets square, rectangular in section exc 13 Sqcm & not exc 25 Sqcm complete all as specified and directed. 10 S&F second classhardwood plain fillets square, rectangular in section exc6 Sqcm and not exc 13 Sqcm complete all as specified and directed 11 Dismantling of timber scantlings 40 sq cm and over in sec, in any position, in unframed/framed work complete all as specified and directed. 12 M &L for second class soft wood as in scantling clean sawn fixed in position complete all as specified and directed. 13 M & L for second class soft wood as in scantling clean sawn fixed in position but except wood complete all as specified and directed. 14 Taking down of shutters of any description exc 2 Sqm each complete all as specified and directed. 15 Taking down chowkhats or frame exc. 1.5sqm and n.exc. 4 sqm each with shutter (without taking out shutters from the frame) complete all as specified and directed. 16 Taking down chowkhats or frame n.exc. 1.5sqm each with Shutter (without taking out shutters from the frame) complete all as specified and directed. 17 M&L for second class soft wood plain, solid straight chowkhat and frames, wrought framed rebated on the solid rounded or chamfered, put together with glue penned and joints complete all as specified and directed. 18 S&F IInd class soft wood Glazed and Skeleton shutters open rebated and prepared to receive glass, gauge etc (with sash bar) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc supplied and fixed to chowkhat, 30mm thick shutter for window and ventilator as specified in SSR Part-I , Section-8, clause 8.24 (b) complete all as specified and directed. 19 S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed 20 S&F factory made solid PVC moulded door shutterwith particle board core 28 to 30mm thick (style) with 2, 4, or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying and fixing in frame at site as per specification and drawing. 21 S&F for 100mm long stainless steel butt hinges medium weight cold rolled complete all as specified and directed. 22 S&F 200mm long aluminium alloy, anodised barrel tower bolt of extruded section complete all as specified and directed. 23 S&F 150 mm long aluminium alloy, anodised barrel tower bolt of extruded section complete all as specified and directed. 24 S&F 300mm long aluminum alloy anodized sliding door (bolt type) and fixing clips of sheets, cast of extruded sections and fixing bolts and sliding bolts of extruded section of cast-aluminum alloy complete all as specified and directed. 25 S&F aluminum handles, cast type, anodized 150mm long complete all as specified and directed. 26 M&L for applying two coats of synthetic enamel paint including cleaning dusting of new or previously untreated, priming surfaces of wood ply wood base surfaces for wall, door, window, ventilator and ceiling not otherwise described over 10cm width or girth complete all as specified and directed. 27 Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work, complete all as specified and directed. 28 M&L for brick work with sub class B brick straight or curved on plan exc 6m mean radius built in cement mortar 1:6. complete all as specified and directed. 29 M&L for brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed. 30 M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in Cement Mortar 1:4. 31 S&F galvanised mild steel wire cloth 0.46 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks ro galvanised wire stapple 32 S&F Sheet glass ordinary quality 3mm thick, glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane, in repairs, complete all as specified and as directed. 33 M&L weather boarding of second class soft wood,clean sawn, plain, 20mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm lap in repair to replace old or decayed boarding and removing from site complete all as specified and directed. 34 M & L applying two coats of cement based paint on newly plastered or unplastered wall surface including preparation of surfaces, complete all as specified. 35 M&L for providing, cement concrete type B-0 (1:2:4) (using 12.5mm graded crushed stone aggregate)in roof kerbs or mud stops, rounded or chamfered on edgesin lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed. 36 M&L for 75mm thick plain Cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) in sub base flooring complete all as specified and directed. 37 M&L for 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in floorfinished even and rough to receive the topping layer complete all as specified and directed. 38 M&L for 15 mm thick screed bed in cement mortar 1:6 for laying floor finishes complete all as specified. 39 M&L Non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm and n. exc 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe existing surface, complete all as specified and directed. 40 M&L for glazed ceramic coloured tiles of size 450x350mm and7mm thick, as in vertical surfaces such as in skirting and dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10mm thick back coat layer in cement mortar 1:4 complete all as specified and directed. 41 M&L vitrified ceramic tiles 10mm thick (square/rectangular) area of each tilen.exc 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe existing surface complete all as specified and directed. 42 Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. 43 Material and labour for providing precast RCC 1:1.5:3 type A-1 using 20mm graded mechanically crushed stone aggregate as in cover slab for man holes, drains , soak well etc and similar articles etc, set in CM 1:4 with plain faces including chamfered weathering throating etc including necessary form work complete all as specified and directed. 44 M&L for Chequered cement concrete tiles 20 cmX20 cmX25 mm thick sat jointed and pointed in neat cement slurry in floor with grey cement and no pigments with over and including 20 mm thick screed bed in (1:4) complete all as specified and directed. 45 M&L for 75 mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth protection in subbase complete all as specified and directed. 46 S & F PVC (SWR) pipe 110mm bore single in any type with rubber ring joint laid in wall/trenches /floor complete all as specified and directed. 47 S & F PVC (SWR) pipe 75 mm bore single in any type with rubber ring joint laid in wall/trenches /floor complete all as specified and directed. 48 S & F PVC (SWR) bend any radios 110mm bore complete all as specified and directed. 49 S & F PVC (SWR) bend any radios 75mm bore complete all as specified and directed. 50 S & F in repair PVC (SWR)gully trap 125/110mm setting and jointing with solvent cement complete all as specified and directed. 51 S&F PVC valveless syphonic action type flushing cistern, low level white with inlet ball valve float and handle including brackets (10 Ltr) capacity, with flush pipe etc fixed complete all as specified and directed. 52 S&F for Vitreous China water closet pan (pedestal pattern), white with seat cover and hinging device, fixing bolts etc (excluding flushing cistern and including flush pipe) complete all as specified and directed. 53 S & F PVC (SWR) reducers 75/110mm bore complete all as specified and directed. 54 Supply and fix 5mm dia and over upto and including 10mm dia mild steel TMT bars in stirrups, spacers and binders complete all as specified and directed. 55 S&F in repair PVC valve less, syphonic action type flushing cistern, 10 ltr capacity low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed. 56 S&F in repair 32 mm Waste coupling of PTMT half or full threaded, minimum weight 32mm 45gms complete all as specified and directed. 57 Supply and fix in repair Chromium Plated bib taps, cast copper alloy, fancy type with capstan head, crutch or butterfly handle chromium plated,screwed down high pressure, screwed for iron pipe or for brass ferrule 15 mm dia bore, fixed complete all as specified and directed. 58 S&F in repair pillar tap 15mm bore cast copper alloy, with captain head chromium plated screwed down high pressure, with or without lettered Hot or Cold with long screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. 59 Supply and fix repair angular stop valves, cast copper alloy, screwed down high pressure, fancy type with crunch or butterfly handle, chromium plated, screwed both ends for iron pipe or for unions, or for 15mm dia bore complete all as specified and directed. 60 Supply and fix, towel rail 600 mm long (between flanges), 20mm dia, ‘D’ type, chromium plated brass, fixed to walls with screws and plastic cleats, fixed as in repairs, complete all as specified and directed. 61 S & F 600 mm x 450 mm size bevelled edge mirror of selected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. 62 Supply & fix in repair PVC connections of PTMT, non corrosive, with nuts & washers on both ends, 450mm long, suitable for 15mm dia bore pipe, fixed as in repairs, complete all as specified and directed. 63 Supply and fix, grating square (SLIT) 150mm size, of PTMT (Openable), fixed as in repairs, complete all as specified and directed. 64 Taking up or down steel tubing and connections, size 15 mm dia bore complete all as specified and directed. 65 Material and labour, galvanised steel water tubing, medium grade, with all fittings and fixed complete to wall and ceiling or laid under floor, 15 mm dia bore pipes, including cutting existing steel tubing & screwing, if required for alterations and additions, complete all as specified and directed. 66 Dismantling water tanks exc 500 and n exc 1000 ltr complete all as specified and directed. 67 M&L for rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including float valve and fittings of 500 ltrs capacity all as specified in SSR Part I complete all as specified and directed. 68 S&F in repairs vitreous China wash basin, white, flat back, size 550x400mm excluding taps, waste chain 7 plug and porcelain stopper but including brackets complete all as specified and directed. 69 S&F in repairs Vitreous China bowl urinal flat back, of size 465x355x265mm white (minimum), with grating and union for discharge pipe including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including discharge pipe of PVC 32mm dia complete all as specified and directed. 70 S&F Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed with 20mm dia complete all as specified and directed. 71 Dismantling wrought iron or mild steel work of any description not otherwiseprovided for complete all as specified and directed. 72 S & F mild steel work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. with Fe 410 W (Gde E-250) quality A complete all as specified and directed. 73 All as per item No 72 above but rejection & fixing only complete all as specified and directed. 74 S&F clean swan batten at 30 cm centre exc 5 and not exc 15 cm of 2nd class soft wood complete all as specified and directed. 75 Dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section, framed or unframed work complete all as specified and directed. 76 M&L for 2nd class soft wood plain fillet, square, rectangular or triangular in section, clean sawn exc 3 Sqcm and not exc 6 Sqcm secured with nails complete all as specified and directed. 77 Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed 78 M&L for brick work with old size bricks, straight or curved on plan exc 6m radius, in cement mortar 1:6 complete all as specified and directed. 79 Taking down cement plaster on brick walls etc, including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. 80 M& L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick / concrete/stone, surfaces and finished even and smooth without using extra cement mixed with WPC @ 3% by Wt. of cement (External surfaces) complete all as specified and directed. Note:-WPC shall be measured and paid separately. 81 Supply only approved integral water proofing compound complete all as specified and directed. 82 M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in CM 1:6 and finished even and smooth without using extra cement (Internal surfaces) complete all as specified and directed. 83 M&L for preparation of newly plastered surface of walls and applying two coat of cement base paint complete all as specified and directed. 84 M&L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper over a coat of cement primer complete all as specified and directed. 85 M&L for preparation of old steel/galvanised surfaces over 10cm width or girthand applying one coat ofsynthetic enamelpaintcomplete all as specified and directed. 86 M&L for preparation of new steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxidecomplete all as specified and directed. 87 M&L for two coats of synthetic enamel paint over one coat of pink primer on newly prepared wooden surfaces of any description, not otherwise described over 10cm width or girth complete all as specified and directed. 88 Taking down shutters exc 1 Sqm and n. exc 2 Sqm each complete all as specified and directed. 89 S&F 35mm thick, 2nd class soft wood, Glazed and skeleton shutter, open rebated and prepared to receive glass, gauge etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc complete all as specified and directed. 90 S&F mild steel work with angle or any other section as in door frame, window guard bars, grill and other similar work complete all as specified and directed. 91 M&L for precoated sheet type door spring, heavy type, 200 mm long including roller and roller plate complete all as specified and directed. 92 S&F for steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed. 93 S&F Harrison rails, stainless steel with fixing brackets, stops, rollers etc., complete all as specified and directed. 94 Hacking out old broken glass (any thickness size quality or description) from wooden frame glazed with putty or wooden beads complete all as specified and directed. 95 M&L for PCC (1:3: 6), type C-1 using 20mm graded aggregate as in surface channel and drain complete all as specified and directed. 96 Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/ stopped ends etc complete all as specified and directed. 97 M&L for preparing the new plastered surfaces of walls up to any height and applying two coats of white wash complete all as specified and directed. 98 M&L for Machine cut Kota stone slab flooring 18-20mm thick over screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and 15mm thick screed bed in CM 1:4 complete all as specified and directed. 99 M&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. 100 S&F in repair 1.25mm thick Steel sheet rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position asindicated, complete: push pull or manual type including safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed complete all as specified and directed. 101 S&F for 35mm thick, 2nd class soft wood, plain framed panelled shutter (any number of panel) with panel of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers supplied and fitted to chowkhats complete all as specified and directed. 102 S & F Mild Steel butt hinges 100mm long medium weight complete all as specified and directed. 103 S&F for 75mm long stainless steel butt hinges medium weight cold complete all as specified and directed. 104 S&F Aluminium handle, cast type, anodised 100 mm long complete all as specified and directed. 105 Dismantling boarding, any description fixed in any position with nails complete all as specified and directed. 106 M&L 20 mm thick 2nd class soft wood boarding, planed one side, with butt joints and fixed with nails as in wall, facia, eaves boarding complete all as specified and directed 107 All as per item No 106 above but fixing only. 108 M & L for stone walling of random rubble, uncoursed well bonded, bedded and solidly hearted built in CM 1:6 complete all as specified and directed. 109 M&L brick work with fly ash old size bricks, straight or curved on plan exc 6m radius, in cement mortar 1:6 complete all as specified and directed.. 110 M&L for preparation of old wooden surfaces of any description, not otherwise described over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed. 111 Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings, removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specified and directed. 112 Taking down MCB DBs complete with MCBs/Isolator etc removing materials from siteand making good disturbed surface of walls, floors etc. complete all as specified and directed. 113 M & L for point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC FRLSH insulated un-sheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC FRLSH insulated un-sheathed copper conductor single core multi stranded flexible cable (green colour) as earth lead in and including cable 1100 volts grade including casing and capping/conduit (ISI marked)including sunk cast iron/pressed steel terminal boxes, junction boxes, other boxes andsheet of suitable sizes for mounting of switches, sockets, fan regulators, light fittings etc. covered with suitable plastic laminated sheet or PVC gang box 2 to 8 way as per site requirement including cutting chases to wall making good the disturbed surfaces to match with theexisting specification complete all as specified and directed. 114 All as per item No 113 herein before but wiring with 1.5 sqmm copper wire ( FR-LS-H)and 1.5 sqmm earth wire for socket outlet 3 pin 5 amps on same board. 115 All as per item No 113 herein before but wiring with 1.5 sqmm copper wire (FR-LS-H) and 1.5 sqmm earth wire for socket outlet 3 pin 5 amps on independent board. 116 All as per item No 113 herein before but wiring with 4 sqmm copper wire (FR-LS-H) and 2.5 sqmm earth wire for socket outlet 6 pin 15 amps on independent board. 117 S&F switch piano flush button single pole, one way 5 amps complete all as specified and directed. 118 S& F of Socket outlet 2 in 1, 3 pin, 6A complete all as specified and directed. 119 S & F switch socket combination 2 in 1,5A, flush type complete all as specified and directed. 120 S & F switch socket combination 5 pin 16A, flush type complete all as specified and directed. 121 Supply and fix ceiling rose with earth terminal 2/3 connection, PVC/ polycarbonate, isolated body. 122 S&F LED, 20 Watts, 4 ft, fittings complete with all accessories for mounting light fittings complete with earth terminal connection/ PVC/ polycarbonate, isolated body. complete all as specified and directed. 123 M & L Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for batten fittings complete all as specified and directed. 124 Supply and fix LED Bulb 9 Watt all as specified and directed by Engr-in-Charge. 125 S&F 09W/10W Bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. 126 S&F of distribution board single pole & neutral with 200 Amps rated bus bar, for double door IP-42 DBs ,made outof sheet steel enclosure, recessed type, factory made powder coated12 way -240 volts suitable for housing MCBs and isolators complete in all fixing material/accessories etc complete all as specified and directed. 127 S&F of distribution board single pole & neutral with 200 Amps rated bus bar, for double door IP-42 DBs, made out of sheet steel enclosure, recessed type, factory made powder coated8 way -240 volts suitable for housing MCBs and isolators complete in all fixing material/accessories etc complete all as specified and directed. 128 S&F MCBs single pole 240 volts 6 to 32 Amps 10 KA C curve series, complete all as specified and directed. 129 S & F of MCB SPN, 240 volt, 32 Amp capacity, 10 KA, C curve complete all as specified and directed. 130 Supply and Fixing 1100 Volts grade heavy duty cable PVC insulated multistranded aluminium conductor served with PVC tape and overall PVC sheathed in services connections suspended by insulating hanger not more than 1 mtr apart including 4mm dia GI suspension wire one twin core cable flat or circular of size 10 Sqmm 2 core including service bracket complete all as specified and directed. 131 M & L for Earthing complete with galvanised steel earth plate electrode 60x60cmx6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level)with top edge lead of the platen ot less than 1.5 mtr below normal ground level, connected galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. 132 All as per item No 113 herein before but wiring with 2.5 sqmm copper wire (FRLS) and 2.5 sqmm earth wire for socket outlet 6 pin 15 amps on independent board. 133 Supply and fixing in replacement LED warm lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. 134 Supply and fixing LED luminaire 600 mm x 600 mm,35/36watt 220 V AC recessed type/surface type as require with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling/false ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. 135 S&F sheet metal enclosure for DBs (double door type) when MCBs to be used single pole and neutral 8 way including blanking plate as required with 200 amps rated busbar 240V, fixed sunk/flush to the wall complete all as specified and directed. 136 Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathed of PVC tape overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, including service bracket for incoming through one twin core cable of size 16 Sqmm complete all as specified and directed 137 Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp, bracket GI with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified and directed. 138 Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. 139 Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers, shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm sweep complete with fixing arrangement and connection including cuttring chasses hole in the wall for exhaust fan etc complete all as specified and directed. 140 Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathed of PVC tape overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, including service bracket for incoming through one twin core cable of size 16 Sqmm complete all as specified and directed 141 Supply and fixing Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 25x4 mm galvanised iron strip complete all as specified and directed. 142 Supply and fixing Air termination, single pointed aluminium rod 12mm dia and 300 mm long complete all as specified and directed. 143 As per srl item No131 above but using galvanised iron strip 25×4 mm as earthing lead up to 7 mtr.
|