Tender For Repair And Renovation Of Communication Server Room At Fhq Ssb, East Block-V, R.K. Puram, New Delhi.; 1 Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 2 Providing and laying vitrified floor tiles in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm 3 ProvidingandlayingVitrified tilesindiferent sizes (thickness tobe specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm 4 Providing andapplyingplaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete. 5 Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 6 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 7 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1cement: 4 coarse sand) 8 Demolishingbrickworkmanually/bymechanicalmeansincluding stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar 9 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area 3 sq. metres and below 10 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead .For thickness of tiles 10 mm to 25 mm 11 Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. 12 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) :For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) 13 Forshuttersofdoors,windows&ventilatorsincluding providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 14 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) 15 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer- in-charge. With stainless steel cover plate minimum 1.25 mm thickness 16 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable insurface /recessedmediumclassPVCconduit,withmodular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C 17 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cablein surface/ recessedmedium class PVC conduit alongwith 1No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 18 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cablein surface/ recessedmedium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 19 Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 20 Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 21 Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 22 Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 23 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wireinexistingsurface/recessedsteel/PVC conduit including dismantling as required.Group C 24 Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required. 5/6 A switch 25 Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required 2 way 5/6 A switch 26 Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required 15/16 A switch 27 Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required 3 pin 5/6 A socket outlet 28 Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required 6 pin 15/16 A socket outlet 29 Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required Telephone socket outlet 30 Supplying and installation ofindustrial plug with 5 metre length 8 sqmm electrical power cable 3 core 31 Providing and installation of 32 Amp change over switch L&T make including all necessary fittings 32 ProvidingandfixingfollowingcapacityTP&Ndisconnectorfuse switchunit inside the existingpanelboard withISImarkedHRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32A TP&N 33 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125A,36KA,FPMCCB 34 Cost Index @3 % 35 Market / Analysis Rate (Cost Index not applicable) 36 Providing and applying flame retardancy emulsionpaint Asianapcolite or equivalent with coverage of 10 Sqm per litre as per direction of Engineer-in-charge. 37 Supplying and installation of industrial socket with 32 Amp MCB Havels/legrand/L& T or equivalent make 38 Supplying and installation of 2 ton non-invertor split Air Conditioner Mitsubishi / O General or equivalent, 3 star rating humidity controlled up to 70% including out door stand, copper pipe & drainage pipe (up to 6 metre length) . 39 Supplying and installation 600x600 mm surface led light crompton/bajaj or equivalent make as per direction of Engineer in- charge. 40 Supplying and installation of wall mounted fan 450 mm havels orequivalent make 41 Providing and fixing GI floor Raceway cable tray of (150x75 MM) 16 Guage i/c junction box with nut bolt coupler with cover to use cables as dividers to seperate the cables and to carry networking cables as approved and directed by Engineer-in-charge 42 Early warning fire alarm system and clean agent fire suppression system 43 Securition ASD-532 VESDA system 44 Supplying of MS pipe with fitting and supprt items as pe site requirement complete 45 Installation, testing and commissioning the VESDA system in all respect with one year warranty 46 Supplying of 80 Ltrs PESO approved Seamless Cylinder assembly 47 Supplying and filling Agent - FK 5- 1- 12 (Fluoro Ketone) - UL Listed. (validity as per norms) 48 Supplying Electrical Cum Manual Actuator 49 Supplying Discharge Nozzles are designed to provide the proper flow rate and distribution of FK-5-1-12 to total flood a hazard area : 180 deg. / 360 deg. 50 Supplying Flexible discharge Hose 51 Supplying M.S.Container Strap 80 LtrsCylinder. 52 Supplying Warning Signs-Aluminium 53 Supplying Manifold Discharge Pressure Switch 54 Supplying pipe and fittings 55 Supplying Panel/ Hooter/About release/Cable/Detector etc. 56 Installation testing and commissioning of clean agent fire suppression system complete in all respect with 1 year warranty.
|