Miscellaneous Repairs To Internal Electrification And Conversion Of Conventional Lights To Led Lights In Otm And Md Accn Area At Cdm Under Age Em N Of Ge North Secunderabad; 1 Taking down existing unserviceable point wiring of any description/type/ size of light/fan/power/two way/bell etc on TW batten/conduit includingremovalof batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site area and making good the disturbed surfaces of wall/ceiling all as specified & directed by Engr in Charge. 2 Disconnecting and removingthe MCB DBs/AC Box from any height, stripping out the fitting for examine replacement of US spare parts, reassembling, refixing in original position includingminor repairs for the smooth functioning and testing complete all as specified & directed by Engg in Charge. 3 Taking down old submain wiring of any size and type complete all as specified and directed by Engr in Charge. 4 M&L Concelaed point wiringfor any length complete with all as specified with 1100 volts grade 1.5 sqmm PVC insulated FRLS unsheathed cable with multistrandard copper copper conductor with ISI marking and including non-metallic PVC rigid conduit medium grade of size minimum 20 mm with all accessories concealed in wall/ceiling including continous earth wire 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in wall and modular whilte plate covers with frame for mounting of modular switches/sockets/fan regulators etc,for one light/fan point controlled by one switch complete all as specified and directed by Engr in Charge. Note: Wiring from the DB (distribution box) to switch shall be deemed inclusive in the quoted rate and sunken modular flush box sheet metal enclosures & modular cover plates shall be deemed inclusive in the qoted rate. 5 All as per Item No. 4 above, but one light point controlled by two way switches. 6 All as per Item No. 4 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board . 7 All as per Item No. 4 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board. 8 All as per Item No. 4 above, but for using2.5 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combinationpoint on independent boardincluding running of 2.5 Sq mm FRLS copper conductorPVC insulated cable as earth continuity conductorNote: Modular cover plate with frame and modular metal flux box and cutting/chases includedin the rate quoted. 9 M&L Surface point wiringfor any length complete with all as specified with 1100 volts grade 1.5 sqmm PVC insulated FRLS unsheathed cable with multistrandard copper copper conductor with ISI marking and including non-metallic PVC rigid conduit medium grade of size minimum 20 mm with all accessoriesin wall/ceiling including continous earth wire 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in wall and modular whilte plate covers with frame for mounting of modular switches/sockets/fan regulators etc, One light/fan point controlled by one switch complete all as specified and directed. Note: Wiring from the DB (distribution box) to switch shall be deemed inclusive in the quoted rate and sunken modular flush sheet metal enclosures and modular cover plates shall be deemed inclusive in the qoted rate. 10 All as per Item No. 9 above, but one light point controlled by two way switches. 11 All as per Item No. 9 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board . 12 All as per Item No. 9 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board. 13 All as per Item No. 9 above, but for using2.5 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combinationpoint on independent boardincluding running of 2.5 Sq mm FRLS copper conductorPVC insulated cable as earth continuity conductor 14 M&L Surface point wiringfor any length with 1100 volts grade 1.5 sqmm PVC insulated FRLS unsheathed cable with multistrandard copperconductor with ISI marking and including non-metallic PVC casing caping medium grade of size minimum 20 mm with all accessoriesin wall/ceiling including continuous earth wire 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in wall and modular white plate covers with frame for mounting of modular switches/sockets/fan regulators etc,for one light/fan point controlled by one switch complete all as specified and directed. Note : Wiring from the DB (distribution box) to switch and sunken modular flush sheet metal enclosures and modular cover plates shall be deemed inclusive in the quoted rate. 15 All as per Item No. 14 above, but one light point controlled by two way switches. 16 All as per Item No. 14 above, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board . 17 All as per Item No. 14 above, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board. 18 All as per Item No. 14 above, but for using2.5 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combinationpoint on independent boardincluding running of 2.5 Sq mm FRLS copper conductorPVC insulated cable as earth continuity conductor 19 M&L Surface point wiringfor any length with 1100 volts grade 1.5 sqmm PVC insulated FRLS unsheathed cable with multistrandard copperconductor with ISI marking and including non-metallic existing PVC conduit medium grade of size minimum 20 mm with all accessoriesin wall/ceiling including continuous earth wire 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in wall and modular white plate covers with frame for mounting of modular switches/ sockets/ fan regulators etc, for one light/fan point controlled by one switch complete all as specified and directed.Note: Wiring from the DB (distribution box) to switchand sunken modular flush sheet metal enclosures and modular cover plates shall be deemed inclusive in the quoted rate. 20 All as per Item No. 19 above, but one light point controlled by two way switches. 21 All as per Item No. 19 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board . 22 All as per Item No. 19above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board. 23 All as per Item No. 19 above, but for using2.5 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combinationpoint on independent boardincluding running of 2.5 Sq mm FRLS copper conductorPVC insulated cable as earth continuity conductor 24 S & F Modular switch 1 way 6/10 Amps, 1 Module complete all as specified and directed. 25 S & F Modular switch 2 way 6/10 Amps, 1 Module complete all as specified and directed. 26 S & F Modular switch 1 way 16/20 Amps, 1 Module complete all as specified and directed. 27 S&F Modular Bell Push 10A, 1 Module complete all as specified and directed. 28 S&F Socket outlet modular type multipurpose 2/3 Pin, 6 amps, 230 volts combined 2 Module complete all as specified and directed. 29 S&F Socket outlet modular type multipurpose 2/3 Pin, 6/16 amps, 230 volts combined 2 Module complete all as specified and directed. 30 S & F Modular ceiling fan regulator stepped type heavy duty suitable to work on 230 volts, 2 Module complete all as specified and directed. 31 S & F Switch piano single pole flush type 5 amps, 230 volts complete all as specified and directed. 32 S&F Bell push 5 A flush type complete all as specified and directed. 33 S&F Socket outlet flush type multipurpose 2 in 1, 5 Pin, 5 amps, 230 volts complete all as specified and directed. 34 S & F Switch socket combination flush type multipurpose 2/5 pin 5 amps 2 in 1230 Volts complete all as specified and directed. 35 S & F Switch socket combination 2 in 1 multipurpose 3/5 pin 5/15 amps flush type with complete all as specified and directed. 36 S & F Ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and directed. 37 S & F Electronic type regulator stepped heavy duty for ceiling fan suitable to work on 230 volts complete all as specified and directed. 38 S & F Angle holder insulated body surface bakelite with back plate suitable for angle / batten fittings complete all as specified and directed. 39 S&F Bell ding dong working on 230 volts AC Supply complete all as specified and directed. 40 S&F in replacement of round shape 20 watt 220 Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete with all accessories complete all as specified and directed by Engg-in-Charge. 41 S&F in replacement ofround shape 12 watt 220 Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete with all accessories complete all as specified and directed by Engg-in-Charge. 42 S&F in replacement of recess mountingwith perforated sheet with electronic driver luminaire 34/35/36 watts LED slim panel (2"x2") 220v, upto 150 lumen/watt, 50,000 burning hrs, UGR<19 with central opal diffuser series mounted in grid ceiling surfaces and suitable hanging provision where required including all accessories with new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Note: Cutting of False ceiling and removal of old fitting and re-arranging the False ceiling with existing size, Gypsum board/POP false ceiling is to be done if required and cost of false ceiling work is inclusive of rate quoted. 43 S&F in replacementof wall mounted 4" LED batten 20w,230v, 120 lumen/watt, 50,000 burning hrs, THD<10% andpolycarbonate housing & integrated electronic drive etc.complete with all accessories internally pre-wired with 2 Nos round blocks for mounting arrangements and including connecting up with3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with suitable size complete all as specified and directed by Engr-in-Charge. 44 S&F in replacement wall mounted LED Batten, extruded powder coated aluminum housing heat sink provided for efficient heat dissipation & intergated electronic driver 1x10W, 230 Volts, 50,000 burning hrs, THD<10% , DIFFUSED TYPE connector block, internally pre wired etcincluding new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fittingcomplete all as specified and as directed. 45 S&F in replacementof LED security Light luminaire 25 watts with deep drawn housingincluding all accessories and Lamp, with suitable pipe bracket 25 mm dia 0.60 Mtr length fixed on wall with suitable flat iron clamps and nut bolts complete all as specified and directed. 46 S&F in replacementof LED Bulb 10 watts complete all as specified and directed. 47 S&F in replacement of Environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head 10W edge-lit LED luminaire comprising of high brightness LEDsincluding taking down unserviceable fitting all as specifiedand directed. 48 S&F in replacement of Wall light including 9 Watt LED Bulb, Environmental friendly, ultra modern, energy saving, surface mounted complete all as specified and directed. 49 S & F in replacement LED spot light 06 watts including LED 06 watts lamp COB complete with all accessories all as specified and directed by Engg-in-Charge. 50 S & F 4 module LED Foot Lights of 3 watts including Mounting to Chair/wall in complete all as specified and directed by Engg in charge. 51 S & F 4X1 Recess/surface mounted LED luminarie of 36 watts with soft light along with driver and glass free symmetrical illumination suitable for grid ceiling with all accessories complete all as specified and directed by Engg in charge. 52 Supply and fix in replacementof MCB SP 6 to 32 Amps 240 volts, "B" curve for fixing on MCB DB"scomplete all as specified and directed. 53 S & F in replacement ofMCB SPN 40 to 63 Amps 240 "C" curve 240 volts for fixing on MCB DB"scomplete all as specified and as directed. 54 S & F in replacement ofMCB Four pole, 415 volts, "C" curve suitable for fixing on MCB DB of capacity40 to 100 Amps complete all as specified and as directed. 55 S & F in replacement ofMCB TP 25 to 63 Amps 415 Volts, "C" curve volts for fixing on MCB DB"scomplete all as specified and as directed. 56 S & F Sheet metal enclosure MCB DBSPN 8 way with 200 amps rated bus bar 240 volts double door with locking system complete all as specified 57 All as per Item No 56 above, butMCB DB SPN 12 way 58 S & F in replacement ofHorizontal type TPN DB 4 way double door made out of CRCA sheet housing withpowder coating & confirming to IS 13032, IS 8623, BS 5486 accommodated suitably in a MS enclosure weather proof made out of 3 mm thick MS sheet having hinged and robust locking arrangement including painting by red-oxide one coat and powder coated complete all as specified and directed. 59 All as per Sl item No 58 here in before, but VTPN 4 way DB 60 S & F in replacement of Modular Single pole and Neutral enclosure (Modular AC Box) with a two pin and earth plug and socket complete with one single pole MCB 25 Amps (AC Box) complete all as specified and directed. 61 M & L Submain wiring with 2 runs of single core 4 sqmm PVC insulated sheathed multistranded FRLS 1100 volts grade with copper conductor drawn through non-metalic rigid PVC conduit and conduit accessories of medium grade notless than 25mm dia including one run of single core 4 sqmm PVC insulatedsheathed multistranded 1100 volts grade with copper conductor cable as earth continuity conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain wiring complete all as specified and as directed.Note: 3 runs of 4 Sqmm cable and 1 run of PVC conduit with accessories shall be measured as 1 unit of running metre. 62 All as per Item No 61 above, but 2 runs of single core 6 sqmm and one run of single core 6 sqmm as earth continuity conductor. Note: 3 runs of 6 Sqmm cable and 1 run of PVC conduit with accessories shall be measured as 1 unit of running metre. 63 All as per Item No 61 above, but 2 runs of single core 10 sqmm and one run of single core 10 sqmm as earth continuity conductor.Note:3 runs of 10 Sqmm cable and 1 run of PVC conduit with accessories shall be measured as 1 unit of running metre. 64 M&L Earthing with galvanized mild steel earth plate electrode 60 centimetre x 60 centimetre x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts and washers made out of GI / steel earth wire protected by GI light grade pipe 15 mm bore, 20mm dia light grade galvanisediron pipe with funnel wire mesh for watering and connecting to main switch board / control board all s shown in electrical plateof SSR Pt - I connected to earthing test point and including testing on completion complete all as specified and as directed.Note: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 type C1 by using 20 mm graded aggregate inpit, 50 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded aggregate cover duly reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways,CI cover with CI frame hinges, galvanised iron funnel with watering pipe, wire mesh, complete. 65 M&L Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges ofandings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm complete all as specified and directed. 66 S&F in repairsMCCB Four pole, 415 volts suitable for fixing on MCCB DB of capacity 100 Amps, 25KAcomplete all as specified and directed. 67 S&F in repairsMCCB Four pole, 415 volts suitable for fixing on MCCB DB of capacity 160 Amps, 25KAcomplete all as specified and directed. 68 S&F in replacement of rigid non metallic PVC conduit 20 mm dia exclusive boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers,bell mouth tube ends and fixing accessories such as couplers,lock nuts,saddles,pipe hooks,etc complete all as specified and directed. 69 Taking down the geysers of capacity 25/50 Ltrs from its mounting position by removing all water and electric connections and de-assembling the geyser and carrying out the following works complete all as specified anddirected. (a)Descaling, cleaning the inner tank thoroughly and there should not be any bad taste of water.(b)Examining the water tightness of storage tank after cleaning.(c)Examining the physical condition of thermostat, base assembly fusible plug and outer tank for its serviceability.(d)Inspection of pilot lamps.(e)Reassembling the geyser parts and testing including checking all electrical system (ensuring there is no current leakage) and also conducting hydraulic testing.(f)Re-fixing the Geyser and making electric connections,inlet and outlet water connections and testing and checking of all water inlet, outlet valves connected with geysers.Note : Defective /worn out partsif required shall be measured and paid separately under relevant items in this schedule. 70 S&F in replacement of Rubber PVC gasket to ensure water tightness for 25/50 Litres capacity complete all as specified and as directed 71 S&F in replacement of Mild steel base plate cup of any type with screws of suitable size complete all as specified and as directed 72 S&F in replacement of Heating element of the 1.5 KW/2 KW rating including rubber washers of any make and type complete all as specified and as directed. 73 S&F in replacement of Thermostat suitable for the geyser of 25/50 litres capacity complete all as specified and as directed 74 S&F in replacement of PVC insulated multistrandard copper conductor, 1100 Volts grade, un sheathed, 3 core of 2.5 sqmm size complete all as specified and as directed. 75 S&F in replacement of Industrial type plug top 2 pole with earth plug of 20 Amps of 240 volts capacity complete all as specified and as directed. 76 S&F in replacement ofPVC connecting tube of 450mm long with two brass adopters suitable for hot water of 15mm dia pipesuperior quality complete all as specified and as directed. 77 S&F in replacement of Steel inner tank suitable for 25 litres capacity geyser complete all as specified and as directed. 78 Taking down ceiling fans 48”/56” sweep or Exhaust fans upto 300 mm sweep, removing/cleaning of dust properly cleaning, greasing and overhauling of bearings including refixing in same location and connecting up complete all as specified anddirected.Note : Replacement of defective/worn out parts will be measured and paidseparately. 79 S&F in repairs of Capacitor2.00/2.50Mfd complete all as specified and directed. 80 S&F in repairs of Capacitor3.15/4.00 Mfdcomplete all as specified and directed. 81 S&F in repairs of Ball bearing/Gun Metal Bush of existing ceiling fans on site complete all as specified anddirected. 82 S&F in repairs‘U’ clamps complete with nut, bolts & split pins Heavy duty, suitable for existing ceiling fan on site complete all as specified anddirected. 83 S&F in repairs M.S. rod for ceiling fans 1.5/3/5 ft long with both end suitable size holes and cut mark complete all as specified anddirected. 84 S&F in repairs Nut, bolts with washers for fan blades fixing of ceiling fan of any make/size/type as per site requirement ( 6 Nos for each set) complete a suitable for existing ceiling fan on site complete all as specified anddirected. 85 M&L Rewinding of burnt Ceiling fan motor of size 48"/56" sweep with super enameled copper wire of suitable existing size of any make, type, model includingtransportationcomplete all as specified anddirected. 86 S&F in repairs of Exhaust fan motor of sweep300 mm to 450 mm complete all as specified anddirected. 87 S&F in repairs ofBLDC Ceiling fan Driver Board complete all as specified anddirected.Make Havells/BAJAJ/Crompton Greaves 88 M&L Painting of ceiling fans 48”/56” size complete at site, with super synthetic enamel paint by spraying incl filling cavities with filler, one coat after cleaning all dust etc complete all as specified anddirected. 89 S&F in replacement of Metallic louvers mounted suitable for exhaust fan of 300 to 450 mm on wall complete all as specified anddirected. 90 M & L Making hole to fix the exhaust fan and making good to the disturbed surface complete all as specified anddirected. 91 S&F in replacement of Plastic body including louvers 200 to 300 mm size fan complete all as specified anddirected. 92 S&F in replacement of Motor of plastic body exhaust fan 200mm size complete all as specified anddirected. 93 S& F in replacement of modular white cover plate with frame 1 Module240 V,ISI marked complete all as specified anddirected. 94 S& F in replacement of modular white cover plate with frame 2 Module240 V,ISI marked complete all as specified anddirected. 95 S& F in replacement of modular white cover plate with frame 3 Module240 V,ISI marked complete all as specified anddirected. 96 S& F in replacement of modular white cover plate with frame 4 Module240 V,ISI marked complete all as specified anddirected. 97 S& F in replacement of modular white cover plate with frame 6 Module240 V,ISI marked complete all as specified anddirected. 98 S& F in replacement of modular white cover plate with frame 8 Module240 V,ISI marked complete all as specified anddirected. 99 S& F in replacement of modular white cover plate with frame 12 Module240 V,ISI marked complete all as specified anddirected. 100 S& F Modular metal box 1/2 Modulecomplete all as specified anddirected. 101 S& F Modular metal box3 Modulecomplete all as specified anddirected. 102 S& F Modular metal box 4 Modulecomplete all as specified anddirected. 103 S& F Modular metal box 6 Modulecomplete all as specified anddirected. 104 S& F Modular metal box8 Modulecomplete all as specified anddirected. 105 S& F Modular metal box 12 Modulecomplete all as specified anddirected. 106 S&F in replacement of PVC Round blocks of 4" complete all as specified anddirected. 107 S&F in replacement of PVC Dummy sheets circular type of 4" complete all as specified anddirected. 108 S&F in replacement of PVC Dummy sheets circular type of 6" complete all as specified anddirected. 109 S&F in replacement of Rigid PVC casing &capping 20/25 mm wide complete all as specified anddirected. 110 S&F in replacement of PVC rectangular box (Gang box) with 5 Amps switch socket complete all as specified anddirected. 111 S&F in replacement of PVC rectangular box (Gang box) with 5/15 Amps switch socket complete all as specified anddirected. 112 S& F Surface Modular Box of 6 way along with 6 way Modular plate and 2 Nos of 16 Amps Switches and 6/16Amps multipurpose sockets with connected internal wiring complete all as specified and directed by Engg in charge.Note: Modular Plate, Switches & Sockets are inclusive of the rate quoted. 113 S& Fin replacement of PVC wire of flexible cord with copper conductor,multi stranded of twin core 23/0.198complete all as specified anddirected. 114 S& Fin replacement of PVC copper cable single core multi stranded of size 1.50 sqmmcomplete all as specified anddirected. 115 S& Fin replacement of PVC copper cable single core multi stranded of size 2.50 sqmmcomplete all as specified anddirected. 116 S& Fin replacement of PVC copper cable single core multi stranded of size 4 sqmmcomplete all as specified anddirected. 117 S& Fin replacement of PVC copper cable single core multi stranded of size 6 sqmmcomplete all as specified anddirected.
|