Refilling Medical Oxygen With Cylinder A Accessories In Lease Ready For Use Medicinal Oxygen, In U Cylinder With Supply Of Cylinders From 4 To 10M³; Regulator, Flowmeter And All Necessary Accessories On Lease Regime By The Company Carrying Out The Recharge, Renting Invasive And/Or Non-Invasive Pressure Support Bipap (Bilevel), With Heated Humidifier Minimum Product Specifications: - Ventilatory Mode: Ipap, Ps, Epap/Peep, Cpap, Ps Min, Ps Max E Min Epap/Max Epap - Maximum Pressure 40Cm H²o (In All Modes) - Internal Battery With 2 Hour Autonomy - Maximum Flow: ≫ 200L/Min At 20Cm H²o - Acoustic Pressure Level: 31 Dba - Must Come With Trachea (Flexible Tube 1.8M; 15 To 22Mm) And Mask (Nasal Or Oronasal) And Or Invasive Circuit According To The Patient. Corrective Maintenance Whenever Necessary (Requested). Responsible Technical Installation Of The Tendered Firm And At Home. Bipap/Epap - 4 To 40Cm H²o - Instant Assessment Of Parameters Such As Respiratory Rate (Fr), Tidal Volume, Activation/Cycle Indicator, Inspiration Time. Bivolt Power Supply, Accessories (Included In The 1St Installation), Filter Circuit, Silicone Masks (According To The Size Of Each Patient), Mask Fixator Or Invasive Circuit Heated Humidifier Integrated With Water Compartment, Automatic Bivolt Power Supply. If Necessary, Replacement Must Be At The Expense Of The Provider, Including Installation Costs And All Necessary Accessories, As Well As Maintenance, Which Must Be Completed Within A Maximum Limit Of 48 Hours After The Request, Rental Of A Non-Invasive Mechanical Ventilation Device (Cpap) For The Treatment Of Sleep Apnea And Respiratory Disorders Used In An Environment Home. It Must Allow Positive Pressure Regulation Between 4 And 20 Cm H² And Also Progressive Elevation Regulation Of Pressure Values Between 0 And 45 Minutes (Ramp Time) Bivolt Power Supply - Accessories (Included In The First Installation) Periodic Circuit For Non-Invasive Cpap, Filters, Silicone Masks (According To The Size Of Each Patient); Mask Holder And Heated Humidifier With Water Compartment, Automatic Bivolt Power Supply - If Necessary, Replacement Must Be Paid By The Provider, Including Installation Costs And All Necessary Accessories, Maintenance Must Be Completed Within A Maximum Of 48 Hours After The Request, Rental Of An Ergonomic And Robust Surgical Vacuum Cleaner, Offering Specifications Minimum Practicality In Use. It Must Operate With A Low Noise Level And Continuous/Intermittent Operation Mode. Vacuum Production System Driven By Rubber Diaphragm With High Durability And Eliminating Friction Surfaces. It Has A Stainless Steel Needle Registration, With Fine Pitch, For Vacuum Adjustment, Providing Suction Regulation. Electric Motor With At Least 1/4 Hp, With Internal Forced Exhaust System. Vacuum Gauge Calibrated Up To 30 In Hg (760Mm Hg), Large And Easy To Read. Vacuum Adjustment With Minimum Range Of 1 And 20 In Hg, Maximum Air Flow Of 25 Liters/Min. Minimum Water Aspiration Of 4 Liters/Min. The Bottle Must Have A Safety Valve Activated By A Float To Block The Entry Of Secretion Into The Head. - 127/220 Vac - Bivolt - Accessories: 01 3-Liter Bottle Made Of Unbreakable Polycarbonate, Autoclavable And Graduated In High Relief With Easily Removable Lid For Cleaning Procedures, With Hermetic Sealing System And Safety Stop Valve For Full Bottle And Comengate Atra Extension
|