|
Lot 1 - Design And Implementation Of Integrated Solid Waste Management And Loss Management #, Lot 1 - Lease Of Deposit Type Container - Minimum Area Of 13, 80 M² #, Lot 1 - Standard Model Chemical Bathroom, With Maintenance According To Cetesb Requirements #, Lot 1 - Mobile Siding For Closing Areas #, Lot 1 - Demolition Mechanized Reinforced Concrete, Including Fragmentation, Loading, Transport Up To 1 Kilometer And Unloading #, 03/12/2025 - 14:59:16, 03/12/2025 - 14:59:46, Lot 1 - Mechanized Demolition Of Simple Concrete, Lot 1 - Mechanized Demolition Of Concrete Pavement Or Floor, Lot 1 - Transport Of Rubble, For Distances Greater Than 10° Km Up To 15° Km #, Lot 1 - Disposal Fee For Solid Waste In Landfill, Inert Type #, Lot 1 - Mechanized Cleaning Of The Land, Including Logs With A Diameter Above 15 Cm Up To 50 Cm, With A Truck Available Within The Construction Site, Up To The Radius Of 1 Km #, Lot 1 - Excavation And Mechanized Loading In 1St Category Soil, In Open Field #, Lot 1 - Excavation And Mechanized Loading For Exploration Of Soil In A Deposit. #, Lot 1 - Minimum Mechanized Backfill Compaction Of 95% Pn, Without Supply Of Soil In Open Field #, Lot 1 - Mechanized Excavation Of Trenches Or Pits With A Depth Of Up To 3 M #, Lot 1 - Mechanized Compacted Backfilling Of Trench Or Pit With Roller, Minimum Of 95% Pn #, Lot 1 - 1St E Soil Transport 2Nd Category By Truck For Distances Greater Than 10° Km Up To 15° Km #, Lot 1 - Spreading Of Soil In Boot With Uncontrolled Compaction #, Type Soil/Earth #, Lot 1 - Execution Of Shotcrete - Cement Consumption 350 Kg/M³ #, Lot 1 - Reinforcement In Welded Steel Mesh #, Lot 1 - Reinforcement In Steel Bar Ca-50 (A Or B) Fyk = 500 Mpa #, Lot 1 - Cement Grout For Injection - Supply, Preparation And Application #, Lot 1 - Barbican In Pvc Tube With Diameter 50 Mm #, Lot 1 - Perforated Corrugated High Density Polyethylene Tube, Dn= 2 1/2´, Including Connections #, Lot 1 - 1 Mm Hdpe High Density Polyethylene Geomembrane #, Lot 1 - Geotextile Blanket With Longitudinal Tensile Strength Of 16Kn/M And Transverse Tensile Strength Of 14Kn/M #, Lot 1 - Reinforced Concrete Drill With 25 Cm Diameter - Complete #, Lot 1 - Retaining Wall H=1, 40M, With Drainage #, Lot 1 - Retaining Wall H=2, 50M, Lot 1 - Retaining Wall H=3, Lot 1 - Retaining Wall H=4, Lot 1 - Crushed Stone Ballast #, Lot 1 - Concrete Tube (Ps-2), Dn= 500Mm #, Lot 1 - Concrete Tube (Pa-1) Mm, With Integrated Bag And Sealing Ring Of Approximately 800 Mm # Dn/Di= 800 Mm, Lot 1 - Concrete Half Tube, Dn= 400Mm #, Lot 1 - Manhole Type 1 - 1, 40 1 - Supply Of Ductile Cast Iron Plug Minimum Class 400 (40T) D=600Mm - Nbr 10160 Non-Articulated - For Gal. Rainwater. #, Lot 1 - Installation Of Cap For Stormwater Gallery - Not Articulated, Except Supply Of Buffer #, Lot 1 - Common Wooden Form For Foundation #, Lot 1 - Machined Concrete, Fck = 25 Mpa #, Lot 1 - Laying, Spreading And Thickening Of Concrete Or Mass In Ballast And/Or Filling #, Lot 1 - Masonry Structural Concrete Block 19 Cm - Class B #, Lot 1 - Arg
|