Tender For Special Repair To Md Accommodation Building No. Np-28/1 To 06 At 12 Fd Area Of Gr Unit Under Ge (W) Pathankot.; 1 Sch A Part-I B/R Portion:-Demolition of brick work , built in cement mortar or cement lime mortar including all quions, arches, pillars, etc including demolition of precast rcc articles and disposal of debris out of MoD land complete all as specified and directed. 2 M&L for Brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6)complete all as specified and directed. 3 All as per item No 02 here-in-before but except bricks.NOTE: Old burnt clay bricks retrieved from demolition shall be used. 4 M&L for Brickwork with fly ash old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed. 5 Demolition of cement concrete or lime concrete (unreinforced) in ground floors and Pavings not exc 15 cm thick (below or above ground level ) and removing the debris outside from defence land complete all as specified and directed . 6 Demolition of cement concrete or lime concrete (unreinforced) of any description and in any position not otherwise specifically provided for and removing the debris outside from defence landcomplete all as specified and directed . 7 Surface dressing n exc 15 cm deep in any type of soil complete all as specified and directed by Engr-in-Charge. 8 M&L for hard core of broken stones or boulders of gauge not exc 63mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed 9 M&L for 75mm thick plain cement concrete 1:4:8, type D-2 using 40mm graded crushed stone aggregate as in sub base finishing surfaces of concrete to be even and rough to receive the topping layer complete all as specified and as directed. 10 M&L for 60mm thick M-40 Grade, rubber moulded glossy finish Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 with grey cement and pigment (50% red and 50% yellow) including 25mm thick sand cushioning bed complete all as secified and directed. 11 M&L for precast cement concrete block masonry (kerb stone), 1:2:4 type B-1 using 20 mm graded crushed stone aggregate with solid block, exc 10cm in width and setting in cement mortar 1:6 complete all as specified and as directed. 12 M&L for PCC in foundations, filling and mass-concrete type D-2 (1:4:8) using 40 mm gradedcrushed stone aggregate complete all as specified and directed. 13 M&L for precast reinforcement cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as inlandings, cover slabs (for manholes/septic tank etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar (1:4) complete all as specified and as directed. Note:- Reinforcement shall be measured and paid separately). 14 M&L for cement concrete type C-1 1:3:6 (using 20mm graded crushed stone aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and fair without using extra cement incl making joints every 2.5m and corner filled with bitumen 85/25 complete all as specified. 15 M&L for25mm thick Cement concrete in sub base for receiving floor tiles and mass concrete using Type B-1,1:2:4 (using 20 mm graded crushed stone aggregate) complete all as specified and directed.Note:- Finishing surfaces of concrete to be even and rough to receive the topping layer or floor tiles etc 16 M&L for PCC 1:2:4, type B-0, (using 12.5 mm graded crushed stone aggregate) mixed with water proofing compound as per manufacturer’s instructions as in padding on roof, surface finished even and smooth without using extra cement all as specified and as directed.(Note:- WPC shall be measured and paid separately) 17 M&L liquid water proofing treatment to RCC roof slabin following procedure :(a) M&L forliquid water proofing treatment to RCC roof slab incl dismantling of existing water proofing treatment with existingAPP sheet ,plaster , mud fuskas,brick tiles etc of any description in following procedure:-(b) Prepare the surface by cleanining with concrete surface grinder/ wire brush and a high pressure water jet and ensure that it is free of dust, oil and loose particles. Damaged portions, hollow area must be repaired with epoxy mortar and repair cracks of old concrete by cutting V groove, corners and joints of drain pipes, channels etc. treated with epoxy mortar prepared with epoxy primer (as per manufacturers instructions).(c) Laying 10mm thick rendering in Cement mortar 1:3 with liquid water proofing compound (as per manufacturer’s instructions) on fair faces of concreteroof surfaces, finished even and fair to receive treatment on roof Complete (d) Applying three coats of polyurea waterproofing coating as per manufacturers instructions for maintaining minimum dry film thickness 1.5mm and elongation at break of free film of approx. 500% ± 50% and tensile strength at 14 days of 5MPa.(e)The materials shall be applied with brush or roller, complete in all respect as per the direction of Engineer-in-charge / Consultant. (Note:- minimum 6 hrs interval between two coat shall be maintained)(f) All auxiliary and accessories involved during application should be supplied by single manufacturer as a part of system.Note:- (i) Work to be carried out by authorized applicator and as per manufacturer’s instructions.(ii) Providing test with filling of water for continuous 48 hours if there is any leakage than entire treatment will be done again by contractor without any additional cost.(iii) The rate includes for filling cracks in existing roof with epoxy cement mortar using suitable bonding agent before laying cement plaster. 18 Dismantlingfloor, hearth or wall tiling including cement mortar bedding ( but not backing) removing serviceable tiles to store and rubbish off the premises and removing the debris outside from defence land complete all as specified and directed . 19 M&L for 20mm thick granite (pure black) work (table rubbed and polished) in steps, jambs pillars, window cills ,cooking platform and like including pointing in white cement (1:2) using marble dust with admixture of pigments to match with shade or granite over including 15mm thick screed bed or bedding layerin cement mortar 1:6etc complete all as specified and directed.Note:- The stone slab shall be in one piece over kitchen plateform,window cill and making gas pipe holes 25mm dia with rounded holes and all open edges to be half rounded. 20 M&L for coloured Glazed ceramic tiles in vertical surface such as dado etc 450mmX 350mmX 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles over and including 10mm thick rough cement plaster to receive tiles in CM 1:4 complete all as specified and as directed. Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE 21 S&F joint free non skid coloured Ceramic tiles 07mm to 08mm thick (square/ rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including in this item for necessary raking circular cutting or notching and waste on tiles. 22 S&F joint free non skid coloured Ceramic tiles 07-08 mm thick (square/ rectangular) area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including in this item for necessary raking circular cutting or notching and waste on tiles. 23 S&F joint free non skid Ceramic tiles, coloured 7mm to 8mm thick (square/ rectangular) area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm in vertical/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchincluding 10mm thick backing coat/redering in cement mortar 1:4 for fixing of tiles complete all as specified and as directed.Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE 24 Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.& Brushing neat cement slurry with 3.0kg of cement per sqmetrecomplete all as specified and directed. 25 M&L for non abrasive paving (endura) tiles 300mm x 300mm x10mm thick (square/ rectangular) polished, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement over & including 15mm screed bed CM 1:4 to match complete al as specified and directed. Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE 26 Demolition of Roofs, floors (other than ground floors), beams staircases, landing, cooking platform ,chajjas, & similar suspended work cement concrete is reinforced (reinforcement cut as required to facilitate demolition) and disposal of debris out of MoD land complete all as specified and directed.Note:- Demolition will be done only by mechanical cutter only . 27 M&L for RCC type B-1 (1:2:4) using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves complete all as specified and as directed. Note:- Reinforcement shall be measured and paid separately). 28 Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; not exc. 200mm thick (Horizontal or sloping) Rough finished surfaces of concrete flat complete all as specified and as directed 29 M&L for Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and as directed. 30 Taking down cement plaster of any description and thickness on walls/ceilings etc including racking out joints, hacking for key, scrubbing down with water etcincluding necessary scaffolding up to four storeys height of bldgs if required and removing of debris out of MoD land complete all as specified and as directed. 31 M&L for rendering 15mm thick in CM 1:4 mixed with liquid water proofing compound (as per manufacturer’s instructions) on fair faces of brick work ,concrete surface of wall, fin, facia, chajjas, parapet and similar article finished surface even and smooth without using extra cementincluding necessary scaffolding up to four storeys height of bldgs if required complete all as specified and as directed.(Note:- WPC shall be measured and paid separately) 32 M&L for preparation of newly plastered external surfaces of wall andapplying Two or more coats of 100%Acrylic smooth exterior paint (Weather coat),Premium quality having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.79 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm(weather proof/weather coat) without any brush marks on the surface in any colour over and including 1 to1.5mm thick water proof cement based wall care putty and necessary scaffolding up to three storeys height of bldgs, Shade/colour shall be approved by GE, all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed. 33 M&L for complete removal of existing treatment on external surfaces of wallandapplying Two or more coats of 100%Acrylic smooth exterior paint (Weather coat),Premium quality having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.79 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm(weather proof/weather coat) without any brush marks on the surface in any colour over and including 1 to1.5mm thick water proof cement based wall care putty and necessary scaffolding up to three storeys height of bldgs, Shade/colour shall be approved by GE, all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed. 34 M&L for rendering 15 mm thick in cm 1:6 on other than fair faces of brick work , concrete surfaces of wall,finishing surfaces even and smooth without using extra cement including necessary scaffolding up to four storeys height of bldgs if required complete all as specified and as directed. 35 M&L for preparation of newly plastered internally surfaces of wall and applying min 1.5 mm thick wall care putty on the surfaces & making the surface absolutely smooth surface and applying one coat of primer (as per manufacturer’s recommendations) on the surfaces and applying two coats of distemper oil emulsion finished without any brush marks on the surface in any colour including necessary scaffolding up to four storeys height of bldgsif required ,Shade/colour shall be approved by GE,all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed. 36 M&L for complete removal of existing treatment internally surface of wall and applying min 1.5 mmthick wall care putty on the surfaces and making surface absolutely smooth and applying one coat of primer (as per manufacturer’s recommendations) on the surfaces and applying two coats of distemper oil emulsion without any brush marks on the surface in any tint including necessary scaffolding up to four storeys height of bldgs if required ,Shade/colour shall be approved by GE,complete all as specified and as directed. 37 M&L for Rendering 5mm thick on fair faces of brick work or concrete surfaces in CM (1:3) in ceiling complete all as specified and as directed. 38 M&Lfor preparation of newly plastered surfaces of ceiling and applying three coats of white wash without any brush marks on the surface including necessary scaffolding up to four storeys height of bldgsif required complete all as specified and as directed. 39 M&L for complete removal of existing treatment from ceiling surface and applying three coat of white wash on undecorated surfaces without any brush marks on the surface including necessary scaffolding up to four storeys height of bldgs if required complete all as specified and as directed. 40 M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified & directed. 41 M&L for Washing, rubbing down and stopping of distempered and painted surfaces of wall and applying three coat white wash evenly complete all as specified. 42 M&L for preparation of old painted steel and iron surfaces of any description over 10 centimeter width or girth and applying one coat of synthetic enamel paint in any colour finished without brush mark on surface including necessary scaffoldingcomplete all as specified and as directed. 43 M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer all as specified and directed. 44 M&L for writing letters or figures (block, Roman, Italic or Indian) exceeding 15 centimeter high but not exceeding 30 centimeter high etc with synthetic enamel paint including necessary scaffolding up to four storeys height of bldgsif requiredcomplete all as specified and as directed. 45 M&L for cutting down plants / trees of girth not exc 15 cm & surface are not exc 0.36 Sqm each from roof tops /sides of external walls of buildings, chajja, wall junctions, junctions of of rain water / soil /waste vent pipes including taking out roots entered in wall/slab surfaces and making good the surfaces including repairing the CI/GI/PVC joints of affected locations by applying TUFALO (herbal medicine )and making good to suit the adjoining surfaces using PCC type 1:2:4, type B-O or cement mortar 1:2 complete all as per manufacturer instructions and as specified. NOTE: Any CI/GI/PVCpipes and fittings damaged during work shall be replaced by new one to insure leakage / seepage free joint without any extra cost to the department and Unit rate quoted by tenderer shall included for use of all scaffolding, trestles, ladders, cradles etc ,hoisting, lowering and protective measures etc up to four storeys height of bldgs and removing of debris out of MoD land complete all as specified and as directed. 46 Supply only `Liquid Water Proofing Compound. complete all as specified and as directed . 47 Taking down chowkhats or frames exc 1.50 and n.exc 4 Sqm each (without talking off shutters from the freme) complete all as specified and directed. 48 Taking down chowkhat or frames with shutters (without taking off shutters from the frames) area not exc1.5 Sqm each and removing from site. 49 Taking down shutters of any description exc 1 sqm but not exc 2 sqm eachand removingfrom site complete all as specified and directed. 50 Taking down shutters of any description exc 1 sqm and n exc 2 sqm and refixing in same opening after easing, adjusting and replacement of minor nails etc, complete all as specified and directed. 51 S&F pressed steel frames door 105 x 60 x1.25 mm with one or more rebates including necessary fixing lugs/hold fast duly tarred with bitumen and sanding with sharp clean sand, hinges, lock strike plateincluding one shop coat of primer complete all as spd and directed 52 S&F pressed steel frames door 165 x 60 x1.25 mm with one or more rebates including necessary fixing lugs/hold fast duly tarred with bitumen and sanding with sharp clean sand, hinges, lock strike plateincluding one shop coat of primer complete all as spd and directed 53 M&L for cement concrete type C-0, 1:3:6 using 12.5 mm graded crushed stone aggregate as in back filling ofhollow portion of frame with plain cement concrete and for fixing of hold fast complete all as specified and directed. 54 S&F 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, confirming to IS- 2202(Part-I-1999) , ISI Marked complete all as specified and directed 55 S&F 35mm thick factory made 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats Note:wire cloth shall be measured separately 56 S&Fstainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples or using metal nut and bolts complete all as specified and directed. 57 M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified. 58 M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paintall as specified. 59 S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet & edges will be painted to match with printed sheet ,reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. 60 S&FFactory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded wood grain printed PVC sheet PVC ‘C’ channel having a plain colour PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheet for top rail,lock rail & bottom rail on either side & as gap insert for top rail & bottom rail;Panelling of wood grain printed PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable & 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (900 ) used instead of exposed portion of PVC sheet beading suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. 61 S&FSteel window/ventilator factory made, made out of mild steel box type and shutter suitable for double shutter i.e. Glazed and gauged shutter. Glazed shutter made out of hollow section with sash bar and gauged shutter made out of hollow section without sash bar including hinges, tower bolt, handle, grill10 mm sq bar includingtwo coat of synthetic enamel paint overonecoat of red oxide primer, tarred hold fasts, PCC bed blocks for fixing hold fast , includingplain/figured glass and wire mesh complete all as per details shown in drawing No CEPZ/TD-245/01 sheet No 1/1 and CEPZ/TD-246/01 sheet No 1/2 & 2/2including taking down existing spoiled and unserviceablewindows/ventilators of any type ( wooden/steel) complete all as specified and directed 62 M&Lfor 18 to 20 mm thick PVC prelaminated solid board with one side decorative choice laminate and other side balancing white including 3mm thick lipping and equal to thickness of board as in kitchen cabinet, cupboard etc fixed with screws to steel/timber frame work etc complete all as specified and directed. 63 S&F Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed. 64 S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of brass, polished complete all as specified and directed 65 S&F hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws, Size of hasp and staple in mm 100complete all as specified and directed. 66 S&FContinuous (piano) hinges 30mm Width of flaps (when open) ,mild steel, bright finish or electrogalvanised complete all as specified and directed 67 S&F stainless steel butt hinges of size 100mmlong for fixing of pvc door shutter etc complete all as specified and directed. 68 S&F Aluminium, anodised, barrel tower bolts of extruded section and fixed, Length of bolt in 150mm complete all as specified and directed 69 S&F Aluminium handles, cast type, anodised Size of handle in 150mm complete all as specified and directed. 70 S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or castaluminium alloy and fixed Length of bolt in 250 mm complete all as specified. 71 S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor Overall length of cover plate 140mm complete all as specified and directed. 72 S&F 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate including welding to steel frames.complete. 73 S&F in repair 25mm outer dia stainless steel decorative drapery rod ( Model No- SS-25FL of Vista) of thickness 20 gauge and for every 01 RM length, provide 10 numbers stainless steel wings (Model No:- SS CRNG of Vista) with 50 mm dia and proportionate for part there off, with stainless steel brackets ( Model:- SS 25 BR, Vista) near to ends with stainless steel finials ( Model:- SS-1 of Vista with adapter) for 25mm dia drapery rod at both ends. The drapery rod shall be projecting 150 mm outer side from the clesr opening of doors/windows. ( Including necessary fittings) 74 S&F peg set of 4, brass chromium plated, fancy type, superior quality and fixed with screws complete all as specified and directed. 75 S&F brass door magic eye: as given specification material resin lens +zinc alloy,top diameter: 31.2mm, botom diameter approx 24mm, pipe diameter approx 16mm total length approx 50mm, inner height approx 36mm application 35 to 60mm thick viewing angle 200 degree of surrounding without opening the door unique design ultra clear view and superior finish, wide angle best in class lens for all round visibility the outsider cannot hide any ware, the back cover protects you from the outsider observing any movements inside easy to instal with inbuilt screw over a wide range of door thickness from 35 mm to 60mm etc requiredat site complete as directed by Engr-in-charge 76 Taking up or down 15mm bore, steel tubing and connection including cleaning for refixing or removal from site complete all as specified and directed. 77 S&F 15mm bore Steel water tubing medium grade, galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. 78 Fixing only 15mm bore old Steel water tubing including all new galvanized fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. Note: - Old Steel water tube/pipe any type retrieved from taking down shall be used along with all new GI fittings) 79 Taking up or down 20mm bore, steel tubing and connection including cleaning for refixing or removal from site complete all as specified and directed. 80 S&F 20mm bore Steel water tubing medium grade, galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. 81 Fixing only 20mm bore old Steel water tubing including all new galvanized fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. Note: - Old Steel water tube/pipe any type retrieved from taking down shall be used along with all new GI fittings) 82 Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 toends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubing or conduit wiring, etc and making good, cutting not exceeding 10cm girth complete all as specified and directed. 83 S&F in repair Gun-metal, globe or gate valves 15mm bore, with iron wheel head, screwed both end for iron pipe 84 S&F in repair Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both end for iron pipe 85 S&FRotational moulded polyethlene water storage tanks three layers of 500 ltrs capacity white in colourISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm thick Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms) including Dismantling of old brocken water tanks, outlet & over flow pipe including tank nipple etc complete all as specified and as directed. 86 S&F in repair 15 mm borelong body CP Bib taps castcopper alloy fancy type with capstan heads (chromium plated),and cupscrewed down , high pressure for iron pipe mpete all as spd & directed. 87 S&F in repair 15 mm bore Stop valves, fancy type, chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixedcomplete all as specified and as directed. 88 S&F in repair stop valves (ISI marked),15mm dia, cast copper alloy,chromium plated fancy type with long shank and cup (concealed type) screwd down,high pressure with crutch or butter fly handle,screwed both ends for iron pipes or for unions and fixed in pipe all as specified and directed. 89 S&F in repairs CP Pillar taps fancy type 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot or `Cold with long screwed shankS&Fly-nuts, screwed for iron pipe complete all as specified and directed. 90 S&F in repairs Brass CP shower rose 125mm size including fixing to steel pipe or unioncomplete all as specified and directed. 91 S&Fin CP brass towel ring 20mm dia, fancy type, superior quality, fixed with and including chromium plated screws and wooden/plastic cleats complete all as specified and directed. Make : ACN-CHR-1121BN of JAQUAR or equivalent in any of the make mentioned in list of products. 92 S&Fin Tubular towel rail, ISI marked 60cm long between flanges , 20mm dia D type Brass Chromium plated inclbrackets, fixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and directed. 93 S&F in repair PVC Coloured bathroom cabinet looking mirror divided into shelf overall size 622mm x 432mm complete all as specified and as directed by Engr-in-Charge. Make: Nilkamal/ Prayag/ Polytuf 94 S&Fin repair 5mm thick looking mirror of size 600x450mmof selected quality glass mounted on 6mm thick AC building board or commercial plywood and aluminium angle beading around mirrior fixed onwall PVC plug and screwsetc complete allas specified and directed 95 S&F in repair soap dish of stainless steel fixed to wall with aluminium screw,complete all as specified and directed. Make Jaquar CAT No. ACN-CHR-1131N or equivalent in any of the make metnioned in list of product. 96 S&Finin repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard & railing 60cm longfixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and directed. 97 S&F in repair corner glass shelf with bracket fixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and as directed by Engineer-in-charge Make : ACN-CHR-1173 of JAQUAR or equivalent in any of the make mentioned in list of products. 98 S&F in repair viterous China squatting pan, `Orrisa pattern, size 580 x440 mm white, witht integral foot rests (excluding flushing cistern and flush pipe) including connection to trap,and to flushing pipe, anti-syphonage pipe,etc. complete including making good to floor complete all as specified and as directed. 99 S&Fin repairs 10 ltrs capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with intel, ball valve, float and handle including brackets ,fush pipe of polyethylene of low or high density or PVC 32 mm dia complete all as specfied and as directed. 100 S&Fin repairs Viterous China wash basin, white, flat back, size 550x400mmexcluding taps etc but including brackets,including cutting for and pinning in ends of brackets or erecting stand but including waste coupling of fixing of supply and waste pipe complete all as specfied and as directed. 101 S&F in repair sink made of stainless steel 1 mm thick kitchen or laboratory sink with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets of angle iron and connecting union to pipe over all size 495 mm x420 mmand bowl size 410mmx330mmx 160mm including 40mm Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm 45gms/40mm-60 gms) complete all as specified and directed. 102 S&F in repair32/40 mm bore PVC waste pipe flexible with minimum length 800mm complete all as specified and directed. 103 S&F in repairStainless steel plate rack(Utensil Rack) of size (900mm x 750mmx250mm ) made out of AISl 304 stainless steel 0.63 mm thick sheet fixed with brass screw of required size including necessary fittings/nuts,bolts & washers complete all as specified and as directed. 104 S&F in repair 15mm dia 600 mm long PVC connection including brass check nut at both endsscrewed both endfor iron pipes. 105 Demolition and breaking up drain pipes (Salt glazed ware, PVC/AC or Reinforced concrete) set in cement mortar,and taking out of trenches, if required, Internal dia of pipe in 150MM/200mm 106 S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors all as specified and directed. 107 S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors all as specified and directed. 108 Taking down eaves gutter and rain water pipe any size any pattern , PVC/ AC pipeincluding all fittings ,heads shoes, bends etc including removal to store ,Internal dia of pipe in 75MM/110mm complete all as specified and directed.all as specified and directed. 109 S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls all as specified and directed. 110 S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls all as specified and directed.(ISI MARKED) 111 S&F PVC (SWR) bends any radius 75mm dia all as specified and directed.(ISI MARKED) 112 S&F PVC (SWR) Single T any radius 110mm dia all as specified and directed.(ISI MARKED) 113 S&F PVC (SWR) SingleTradius 75mm dia all as specified and directed.(ISI MARKED) 114 S&F PVC (SWR) bends any radius 110mm dia all as specified and directed.(ISI MARKED) 115 S&F in repairs 75mm PVC floor trap, ISI marked withcp grating with/without waste pipe hole incl jointing to waste pipe fixed with solventcement complete all as specified and as directed. 116 Removing of iron gate and re fixing of gate and including increase height of gate with hold fast as directed by Engr-in-charge. 117 Cutting holes in brick wallsbuilt in cement mortar or cement lime mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required,Depth of embedded portion of holddfasts or lugs measured from the face of the jamb into the wall exc Half brick but not exc one brick complete all as specified and directed. 118 M&L for framed work as in door or gates of angle or other section complete drilled for fixing of steel sheeting or other covering etc. to be prepared for hanging with and including hooks or hinges and hanging also fastening and fixing complete all as specified and directed 119 S&F mild steel plain black sheet 1.00mm thick as in covering to doors shutters etc cut to size edges beaded holes punched, including rounded scraws or rrivets and fixed to wooden steel memberes etc with plain 40mm lap joints or walds/reavated inlcluding b 120 Cutting channels, grooves or rebates in brick/concrete wall n. exc 15 cm girth, and trimming surface complete all as specified and directed 121 Cutting holes into or through brick walls/stone walls built in cement mortar; superficial area exc 150 Sqcm but n. exc 400 Sqcm and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required brick/concrete wall n. exc 15 cm girth, and trimming surface complete all as specified and directed 122 M&L for plaincement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in copings, bed plates including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed. 123 M&L for post construction ATT treatment to points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same all as specified and directed 124 M&L for providing and injecting chemical emulsion for post constructional anti-termite Treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling 12mmdia upto 300mm deep and 300mm centre to centre and plugging holes etc in apron /plinth protection allas specified in IS Code 6313 Part-3:2001 and as directed. 125 M&L for post construction ATT treatmentof soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors all as specified and directed 126 Excavating in post holes (or similar holes) each n exc 0.5 cu. m,etting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,soft/loose soil. 127 S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. 128 S&F mild roof structural steel angles/rectangular hollow section/steel tubular roof trusses (framed), purlines and fastening including distance pieces etc. complete all as specified and directed. 129 M&L for PCC in foundations, filling and mass-concrete type C-2 (1:3:6) using 40 mm gradedcrushed stone aggregate for post complete all as specified and directed. 130 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose of soil. Note:-(1) The excavation work will be carried out by mannualy or mechanical meansin any location/ areaas directed by engr-in- charge. (2) Any dammage occur to water supply pipe line/ electric cable/existing drain/sewage line during excavation workwill be make good up to satisfaction of Engr- in-charge. 131 All as per item No 130 here-in-before but depth exc 1.50 m but n. exc 3.00 m 132 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm with any type of soilcomplete all as specified anddirected. 133 Removing excavated Soils material exc. 250m but n exc. 500 m and depositing where directed 134 M&L for 150mm Reinforced concrete pipes, class NP-3, laid and jointed complete with collarsthickincluding demolition and breaking up drain pipes in cement mortar including demolition of PCC bedding and hunching complete all as specified and directed 135 M&L Concrete bed to drain pipes including packing under,and haunching against the sides of pipes after they are laid and tested in Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate for Bore of pipe in 150mm complete all as specified and directed 136 M&L for 200mm Reinforced concrete pipes, class NP-3, laid and jointed complete with collarsthickincluding demolition and breaking up drain pipes in cement mortar including demolition of PCC bedding and hunching complete all as specified and directed 137 M&L Concrete bed to drain pipes including packing under,and haunching against the sides of pipes after they are laid and tested in Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate for Bore of pipe in 200mm complete all as specified and directed 138 M&LPCC 1:2:4 type B-1 (using 20mmgraded aggr) as insurface channels & drains,benching of manholes complete allas spd and directed. 139 Sch A Part-I E/M Portion:-Taking down old unserviceablecopper/aluminium point wiring (light, fan, socket , power socket and bulk head fittings) on surface wiring on wooden batten/casings & caping complete, including fixture and fittings such as switches, ceiling roses,pendents holder, regulators andsocketsby unscrewing carefully from boards etcand making good disturbed surfaces of walls, as per existing finishescomplete all as spd and directed. 140 M&L for point wiring for one light/one fan controlled by one switch with 1.5 Sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H 1100 volte grade cable, withand including PVC rigid concealed conduit (ISI marked) with all fittings including sheet steel/CI terminal box of adequate size including 1.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable as earth continuity conductor connected to comman earth dolly, complete all as specified and directed.Note:- 1. connection of cable with MCBs/switch sockets shall be done through proper size copper /brass thimbles.2.Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible. 3.Proper colour coud will be used for wiring as per the electrical rule and as directed. 141 All as per Srl item No 140 here-in-before but for 5 pin 5 amps socket outlet on the independent board controlled by one switch SP, one way 5 Amp, 240 Volts. complete all as specified and directed. 142 All as per Srl item No 140 here-in-before but for 5 pin 5 amps socket outlet on the sameboard with other switch complete all as specified and directed. 143 All as per Srl item No 140 here-in-before but for call bell point complete all as specified and directed. 144 M&L for point wiring with 2.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable with in and including PVC concealed conduit heavy duty with all fittings including anodise pressed steel sunken box with bakelite laminated sheet ISI marked suitable for 5 pin 15 amps socket outlet ,including 2.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface finishing the surface tomatch with the existingsurface complete all as specified and directed. 145 S&F switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed. 146 S&F switch Bell push, flush type, 5 amp one way complete all as specified and directed by Engr-in-charge.. 147 S&F switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed. 148 S&F socket outlet 2 in 1, 3 pin 5 amps flush type 240 volts complete all as specified and directed. 149 S&F socket outlet 2 in 1, 5 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed. 150 S&F lamp holder/batton holder/angle holder insulated body with bakelite back plate suitable for fittings complete all as specifiedand directed. 151 S&F ceiling rose 65 x 50mm three terminals complete all as specified and directed. 152 S&F ceiling fanregulator electronicsocket type 5 stage speed variation ISI marked complete all as specifiedanddirected. 153 S&F Bell AC, 230 Volts, single pole complete all as specifiedanddirected. 154 S&F in replacement sleek LED mirror light fitting 2 feet long 1x10 W including LED tube 2 feet long of same make having ballast , bipin holder, connector block etc. complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of suitable size complete all as required at site or directed. 155 S&F in replacement CFLs with LEDLamp, B22type ,14 watt,complete all as specified and directed. 156 S&F in replacement energy saving decorative LED boxtype 20 W, 6500K,cool white, Lumen efficiency 110 lumen/watt, light fitting PVC housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver complete with all accessories prewired and making connections with twisted flexible copper cable of suitable size from ceilling rose/PVC connector to light fittings complete all as spd and directed by Engr -in -charge. 157 S&F energy saving , surface mounted, bulk head luminaire 10 watt with PDC aluminium housing and polycorbonate diffuser with IP 66 protection complete including connecting up with three core twisted flexible suitable size copper conductor cable complete all as specified and directed by Engr-in-Charge. 158 Taking down carefully ceiling fan from the hook including dismantling the blades and minor repair such as replacement of locking pin, reel insulators, bolts, nuts etc and painting one coat of synthetic enamel paint of existing colour including rehanging the same at existing position after cleaning, greasing and connecting up with PVC insulated copper flexiblewire of suitable size from ceiling rose to connector of fan complete all as specified and directed by Engr-in-Charge . 159 M&L for providing/ cutting the round/ square hole of required size in wall finishing thedistrubed surfaces as per existing finishes complete all as spd and S&Fing MS ventilating fansSingle phase, 230 volts 225 mm or 9” H.D EX Fan (900 RPM) complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated copper cable suitable size from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge. 160 M&L for providing/ cutting the round/ square hole of required size in wall finishing thedistrubed surfaces as per existing finishes complete all as spd and S&Fing MS ventilating fansSingle phase, 230 volts 300 mm or 12” H.D EX Fan (900 RPM) complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated copper cable suitable size from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge. 161 S&F and testing ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and connecting with flexible copper conductor of suitable size, 3 core and including writing of MES No with black paint complete all as specified and as directed. 162 S&F in repair sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases in wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed. 163 S&F in repair MCB SP 240 volts any rating from 6 to 40 amps, B cruve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. 164 S&F in repair MCB SPN 240 volts any rating from 6 to 40 amps,B cruve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. 165 S&F inreplacement of existing unsv sheet metal enclosure with sheet metal enclosure MCB distribution board single pole and neutral with a two pin and earth plug and socket 20 amps 240 volts, complete with one single pole MCB of 20 amps C curve complete all as specified and directed . 166 S&F in replacement sub Main Wiring with two PVC insulated unsheathed multistrand FRLS-H flexible copper conductor cable of size 2x6 sqmm and one PVC insulated multistrand unsheathed FRLS-H flexible copper conductor cable of size 6 sqmm(green colour)as earthing lead connecting to main earthing dolly drawn in and including non metallic PVC concealed conduit 20mm dia complete andmaking good to disturbed surface complete of wall/floor with cement mortar and finishes to match the existing surface complete all as specified and directed. 167 S & F in replacement of old unsvsheet metal enclosures distribution boards, double door three phase 415 volts 4 ways vertical TPN DB for comprisingthree phase four wire copper strip bus bar of appropriate capacitycomplete all as specified and directed and comprising of the following (a)MCCB FOUR POLE 63 AMPS AC415 VOLTS16 KA=01 NOas incoming and 12 nos. MCB SP 40 Amps, C series as outgoing (Note :-(i) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(ii)connection of theMCCBs/ MCBs with cableshall be made through appropriate size pin /bottle type thimble -properly crimped.(iii)all the vacant holes of the DB shall be provided with blank plates of appropriate size. (iv) double continuous earth wire shall be provided for each three phase DB from earthing mains dolly (v)MCCBs andMCBs should have a same make as of DB. 168 S&F in repair bldg secuirty light fitting energy saving high efficiency LED street light fitting 35 Watts, 5700 K, IP 66, having pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, prismatic polycarbonate cover complete including GI bracket of size 25 mm dia bent to shape having length not less than 0.9 mtr fixing with clamp etc and making connections using suitable size copper cable from ceilling rose/ PVC connector to light fittings or as directed by Engr-in-chrage. 169 M&L for earthing complete with galvanised steel earth plate electrode , 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level)withtop edge of the platenot less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point , GI tubing 15 mm bore light grade protection pipe , GI watering pipe 20mm bore light grade with funnel and wire mesh , charcoal ,salt packed around the earth plate and precastPCC 1:2:4 (Nominal mix ) reinforced with XPM having weight not less than 4 kg /sqm including suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover including earth workin any type of soil , removal of surplus soil to a distancen.exc 50m and connecting , testing on completion completeall as shown on electricplate No 05 of SSR -2009 Part I and connecting to existing earth test point complete all as specified and directed or including testing on completion.(Note: Excavation and earth work is deemed to be included in the rates quoted). 170 Taking down single phase electric meter by disconnecting existing electric connection and re-fixing of the same electric meter at new location as directed by Engg-in-charge including connection with 3 core 4 Sqmm copper wire from DB to meter complete all as specified and as directed. 171 Supply, laying and testing in replacement LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 16 sq. mm 4 core complete all as specified 172 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil for laying of cable ,pole foundation,stay,laying of pipe etc complete all as specified and directed. 173 Returning filling in, including spreading ,leveling ,watering and well ramming in layers not exc 25 cm complete all as specified. 174 Removing excavated soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. 175 M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified(Note:-Punned thickness shall be measured and paid) 176 M&L for brick covering equal to length of bricks as mechanical protection to cable with well burnet sub class ‘B’ bricks laid as directed by the Engr-in-Charge. 177 S&F GI tubing light grade 50 mm bore for cable protection laid in trenches in road crossing or fixed to wall/Pole including fittings /clamp complete all as specified and directed.
|