Scotch-Lock Terminals Piercing Cable Connector Uy2, Piercing Connecting Terminals Are Designed For Quick Installation And Reliable Connection Of Two Copper Or Copper-Copper Steel Conductors With A Diameter Of 0.4 To 0.9 Mm Without Removing The Insulation. The Terminal Body Must Be Made Of Non-Flammable Polymer That Is Resistant To Uv Exposure And Temperature Changes. The Contact Part Must Have A Gel Filling To Protect The Connection From Moisture And Corrosion. The Terminals Must Be Capable Of Operating At Temperatures From –20 °C To +60 °C And Withstand Operating Voltages Up To 300 V In Low-Voltage Communication Circuits. Installation Is Carried Out By Crimping With A Standard Tool. The Service Life Of The Product Must Be At Least 10 Years. Delivery - In Packs Of 100 Pieces. The Manufacturer Provides A 12-Month Warranty On Uy2 Adhesive Lock Terminals, Subject To Proper Use And Installation. Delivery Of Goods Must Be Carried Out At The Request Of The Customer, On Weekdays From 9 To 18 Hours For 16 Calendar Days Until December 31, 2025., Telephone Socket, Telephone Socket Is Designed For Connecting Subscriber Telephone Sets And Other Telecommunications Equipment And Must Provide Switching Of One Communication Line Through A Connector Of The Rj-11 (6P4c) Standard Or Equivalent. The Design Of The Socket Must Be Surface-Mounted And Must Be Made Of Impact-Resistant Plastic Such As Abs Or A Material With Similar Characteristics. The Product Must Provide An Electrical Strength Of At Least 1500 V, Operation At Temperatures From –10 °C To +45 °C And Have A Service Life Of At Least 10 Years. Body Color: White Or Light Beige. The Socket Must Be Supplied Complete With A Cover, Housing, Contact Group And Fasteners. Delivery Of Goods Must Be Carried Out At The Request Of The Customer, On Weekdays From 9 To 18 Hours For 16 Calendar Days Until December 31, 2025., Rexant Four-Core Telephone Cable In Pvc Sheath Is Intended For Use In Low-Voltage Communication Lines, Connecting Telephone Sets, Distribution Devices And Other Telecommunication Systems. The Cable Must Consist Of Four Stranded Copper Cores, Ensuring Stable Conductivity And Durability. Each Core Should Have A Cross-Section Of About 0.05 Mm² And Be Insulated With Flexible Polyvinyl Chloride Material That Is Resistant To High Humidity, Household Mechanical Stress And The Influence Of Ultraviolet Radiation When Used Indoors Or Outdoors Under A Canopy. The Outer Sheath Of The Cable Should Be Made Of Light Pvc, Which Provides Protection From External Damage And Ease Of Installation. The Electrical Resistance Of The Conductor Should Be No More Than 0.165 Ohm/M, Which Guarantees Effective Signal Transmission And Minimal Losses. The Diameter Of Each Core Should Be Approximately 2.4 X 4.8 Mm Insulated (Flat Configuration). The Minimum Bending Radius Must Be At Least Ten Times The Cable Diameter. The Length Of The Cable In A Coil Is 100 M. The Cable Must Remain Operational In The Ambient Temperature Range From –50 °C To +60 °C, Which Allows It To Be Used In Most Climatic Conditions. Use In Telephone Lines, Low-Power Communication Lines, Security And Other Low-Current Circuits Is Allowed. The Service Life Of The Product Must Be At Least 10 Years. The Warranty Period For Telephone Cable (4-Core, Copper, Pvc Sheathed) Is 24 Months. Delivery Of Goods Must Be Carried Out At The Request Of The Customer, On Weekdays From 9 To 18 Hours For 16 Calendar Days Until December 31, 2025., Wire For Telephone Devices 4 Cores Copper Pvc Sheath, Rexant Telephone Cable For Laying Communication Lines Should Be A Four-Core Wire In A Pvc Sheath, Intended For Connecting Telephone Sets And Other Low-Voltage Devices Indoors. The Cable Must Consist Of Four Stranded Copper Cores With A Diameter Of At Least 0.28 Mm Each (6×0.10–0.12 Mm), With Individual Pvc Insulation. The Diameter Of The Insulated Core Should Be About 0.95 Mm. The Outer Sheath Of The Cable Is Made Of Wear-Resistant Pvc, Which Provides Protection From Moisture And Mechanical Stress, As Well As Resistance To Ultraviolet Radiation When Used Indoors. The Cable Must Have An Electrical Resistance Of The Core Of No More Than 0.165 Ohm/M And Ensure Stable Transmission Of Low-Voltage Signals. The Rated Operating Voltage Must Be At Least 48 V. The Cable Must Remain Operational At Ambient Temperatures From –50 °C To +60 °C, Which Allows Its Operation In Most Climatic Conditions Inside Buildings. The Minimum Bending Radius Must Be At Least Ten Times The Outer Diameter Of The Cable, Which Ensures Safe Installation In Confined Spaces. The Cable Service Life Must Be At Least 10 Years. Roll – A Coil 100 Meters Long. Delivery Of Goods Must Be Carried Out At The Request Of The Customer, On Weekdays From 9 To 18 Hours For 16 Calendar Days Until December 31, 2025.
|