Tender For Repair Replacement Of Unsv Street Light, Flood Light, Timer Panel And Other Connected Items At Zone - Iii Under Age(I) Lansdowne; 1 Excavating in trenches, n exc1.5 m wide and n exc 1.5 m indepth, for foundation, etc. orfor shafts, wells, cesspits,manholes, pier holes, etc. nexc 10 sq m on plan and n exc1.5 m in depth and getting out in hard/dense soil complete all as specified and directed. 2 Description same all as per item No 1 above but for each additional 1.5m or part thereof in depth beyond the first 1.5m in hard/dense soil complete all as specified and directed. 3 Removing excavated material soil n exc. 50m and depositing wheredirected at a level n exc. 1.5 mabovethe starting point complete all as specified and directed. 4 M&L for PCC (1:4:8) Type D2 (using 40 mm gradedstone aggregate) as in foundations of pole/stay including form work complete all as specified and directed. 5 M&L for PCC (1:3:6) type C1 ( using 20 mm graded stone aggregate) as in coping of pole studsincluding formwork complete all as specified and directed. 6 Dismantling and taking out old unserviceable Tubular poles and struts of any size complete all as specified and directed. 7 Dismantling and taking down bend/damaged mild steel work such as cross arms, bracing, supports, clamps & back plates etc complete all as specified & directed. 8 Disconnecting and taking out old unserviceable GI Pipe and Supply, laying & jointing GI water tubing 40 mm bore, light grade as in sleeving etc laid in trenches/pole post/under culvert/under road etc complete all as specified and directed. 9 S&F of steel tubular swaged poles complete as per IS-2713 MS base plate of size 300mmx300mmx6mm, final taper plug, bolts, nuts and screws as specified type 410 SP-31(9 mtr long) includingpainting two coats of aluminium paint over one coat of red oxide primer including 4 Nos band/straps with yellow and black colour in alternate way (250 mm wide each) aluminium paint two coat at a distance 300 mm from plinth block and marking pole nos with black paint including tarring one coat on steel surface embedded in concrete complete all as specified and directed. Note :- Necessary earth work and excavation, PCC in foundation (1:4:8) type D-2, using 40mm graded stone aggregate and PCC (1:3:6) type C-1, using 20mm graded stone aggregate as in plinth block, disposal of surplus soil to a distance not exceeding 50 m shall measured and paid sepearately complete all as specfied and directed. 10 M&L Cross arms, bracings, supports, clamps and back plates fabricatedfrom structural steel sectionsincluding nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shapeor size as indicated or directed andinclusive of one primer coat, oneunder coat and one finishing coat ofpaint complete all as specified and directed. 11 S&F flexible 3 core PVC insulated unsheathed FRLS-H cable of size 1.5 Sqmm, 1100 volts grade heavy duty multi strandedcopper conductor drawn through in non metallic rigid PVC conduit for making electrical connection of street light with poles junction box, complete all as specified and directed. (Note:- PVC conduit shall be measured and paid separately under respective item) 12 S&F Rigid non-metallicPVC conduit of size 20 mm exclusiveof boxes (junction/ terminal) but inclusiveof all tees, bends,elbows, reducers, bellmouth tube ends andfixing accessoriessuch as couplers, locknuts,saddles, pipehooks etc complete all as specified and directed. 13 S & F stay assemblycomplete with all accessories, such as stay plate 300x300x6 mm, stay rod 215 cm long and 16mm dia with nuts including GI Bow turn buckle etc, all as per Electrical Plate No 1 SSR-2009 Part-I complete all as specified and directed. (Necessary excavation and PCC and one set of stay clamps at top of pole & loop insulator of size 90x140mm porcelain, vitreous, white, brown or green shall be measured and paid seperately) 14 S&F Galvanised stay wire of size 7/4mm all as specified and directed. 15 M&L forloop type insulator porcelain vitreouswhite, brown or green small size with overall dimensions 65x90 mm clearence of hole 16mm complete all as specified and directed. 16 S&F in repair of MCCB 4 pole, 415 volt, adjustable thermal and magnetic release type 160 Amp breaking capacity 36 KA complete, including terminal links of suitable amp rating and size all as specified and directed. 17 S&F in repair of MCCB 4 pole, 415 volt, adjustable thermal and magnetic release type 100 Amp breaking capacity 16 KA complete, including terminal links of suitable amp rating and size all as specified and directed. 18 S&F in repair of MCCB 4 pole, 415 volt, adjustable thermal and magnetic release type 63 Amp breaking capacity 16 KA complete, including terminal links of suitable amp rating and size all as specified and directed. 19 S&F in repairs/replacement MCB, SP, AC, 240 volts of 06 to 32 Amps capacity 10 KA, C Series and making connections with suitable size of copper lugs complete all as specified & directed 20 S&F in repairs/replacementMCB, SPN, AC, 240 volts of 40 Amps capacity 10 KA, C Series and making connections with suitable size of copper lugs complete all as specified & directed 21 Supply, laying and fixing or passing in repairs through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq mm 2 core all as specified and as directed. 22 S&F in repairs LED Street Light fitting60 watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corriosion resistant including thermal management in multiple optics complete with IP 65/66 protection,including connecting with 1.5 sqmm, 3 core, PVC insulated copper conductor cable 1100 Volts grade from pole box to light or from overhead conductor to light complete all as specified and as directed. 23 S&F in repairs LED Flood Light 150 watt230 V AC outdoor type with thermal management in multiple optics and equiped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp, including fixed on pole of any type on existing angle iron with help of nuts bolts washer including connecting with 1.5 sqmm, 3 core, PVC insulated copper conductor cable 1100 Volts grade from pole box to light or from overhead conductor to light complete all as specified and as directed. 24 S&F in repair bracket made out of 32mm bore, steel tubings, galvanised, light grade not less than 1.2 mtr long bend to shape with all fitting including fixed on pole with 02 Nos MS Clamp made out of F1 32x6mm complete all as specified and as directed 25 S&F in repair thermoplastic cable junction boxes/enclosure (Distribution Box) for outdoor installation with knockouts for cable entry suitable for cable size 16 to 25 Sqmm of dimension 200mmx140mmx95mm with cable terminals complete fitted on pole with suitable size of MS Clamps F1, nuts, bolts and washers, 01 No MCB SP 6 Amp and painting with two coats of synthetic enamelled paint over one coat of red oxide zinc chrome primer on clamps complete all as specified and directed. 26 S&F in repair thermoplastic service connection boxes/ enclosure (Distribution Box) having busbar with screw bolt connection through fly nut for outdoor installation with knockouts for cable entry suitable for cable size 16 to 25 Sq mm of dimension 450x375x200 mm with cable terminals complete fitted on pole with suitable size of MS Clamps F1, nuts, bolts and washers and painting with two coats of synthetic enamelled paint over one coat of red oxide zinc chrome primer on clamps incl connections of existing service cables with suitable size of thimblescomplete all as specified and directed. 27 S&F in repairs/replacement of XLPE insulated AB Cable 1100 Volts 3 Core x 120 Sqmm (insulated phase conductors) + 1 x 95 Sqmm (insulated neutral messanger conductor) + 1 x 16 sqmm (insulated conductor for street light connections) ISI marked on 09 mtr LT Steel tubular poles incl refixing of existing serviceable street lights with all required accessories complete all as specified and directed. 28 S&F in repairs insulation piercing connectors (IPC) for main/service/street light connections for cable of 16-120 Sqmm with taps ranging from 50-120 Sqmm IPC type 002 complete all as specified and directed and confirming to relevant IS complete all as specified and directed. 29 S&F in repair anchoring clamp with aluminium alloy bracket stainless steel strap, buckles eye hook incl nuts and bolts and washers confirming to relevant IS complete all as specified and directed. 30 S& F in repairs suspension clamp with aluminium alloy bracket stainless steel strap buckles, eye hook incl nuts and bolts and washers confirming all as specified and directed. 31 S&F end cap for cable 120 Sqmm three core + 95 Sqmm and one core + 16 Sqmm one core and confirming to relevant IS complete all as specified and directed. 32 Supply, install and testing in repair LT Feeder pillar panel cubical outdoor type made out of CRCA sheet 3.00 mm thick front hinged openable door includinglocking arrangement, platform mounted with angle iron 40mmx40mmx5mm frame work suitable for 240 volts grade three phase 4 wire 50 Hz AC Supply system, having bus bar chamber with suitable aluminium bus bar 100 Amp rating and accomodated with 63 Amp MCB TPN, with astronomical digital24 Hr timer, contactors of suitable ratingand making all necessary electrical connection complete, the box shall be dust and vermin proof IP-54 class protection alongwith in built short circuit protection conforms to IS/IEC 60947-4-1 complete all as specified and directed. 33 M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. (earth pit not less than 2.25 mtr depth below ground levelat any type of strata) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 32x6mm GI strip as earth strip as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate reinforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI strip upto 7.5 mtrs long with 40 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI strip more than 7.5 mtrs will be measured and paid seperately under relevant items.
|