|
Tender For Special Repair To T - 13, T- 46, T-48 Blocks Of Talwar Camp; 1 Taking down chowkhats or frames n.exc 1.5 sqm each with shutters (without taking off shutters from the frame) complete all as specified. 2 Taking down chowkats or frames exc 1.5 sqm but n exc 4 sqm each but with shutters (without taking off shutters from the frame)complete all as specified. 3 S&F 2 nd class hardwood in scantlings, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue and pinned at joints, complete all as specified. 4 S&F 35mm thick flush shutters, solid core construction with block board core and commercial plywood face panels on both sides, complete all as specified. 5 S&F2nd class hardwood glazed and skeleton shutters, 35mm thick, open rebated and prepared to receive glass/gauze, with sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/gauze, complete all as specified. 6 M&L for preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer including preparation complete all as specified. 7 S&F aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples all as specified and directed. 8 S&F factory made solid PVC door frame of size 50×47mm, made from 5mm plain colour PVC sheet reinforced with MS square tube, complete as per manufacturer’s instructions. 9 S&F factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20mm width struck inside with solvent cement forstyle and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading andjointed together with solvent cement supply & fixing in the frame at site. complete all as specified 10 S&F powder coated (colour of coating as directed) aluminium (minimum 25 micron thickness of coating) ofvarious section as required/suitable for doors, window & partion/Ventilator (sliding /or openable type)etc including fixing and making the frames hinges to receive glass/wire gauge etc.Complete incl all fittings like jointing cleats, glazing clips, rubber neoprene packing. anodised aluminium snap beading screws etc.rubber beading, clips locking arrangement, handle, sealant etc all as specified and as directed. 11 S&F aluminium grill with and including suitable aluminiumanodised frame F/H section as requird manufactured by M/S Decogrill as per design No DG- 104, 7.5 mm thick all as specified and as directed by Engr- in- charge. 12 S&F 3 mm thick sheet glass, ordinary quality, and glazing with oil-putty in panes not exceeding 0.5 sqm each, complete all as specified. 13 S&F aluminium alloy sliding door bolt, plate type, 300 mm long, with hasp and staple (bolt type), including bolts, nuts, and fixing, complete all as specified. 14 S&F for aluminiumanodized barrel tower bolts 200 mm of extruded section all as specified and directed. 15 S&F for aluminiumanodized barrel tower bolts 150 mm of extruded section all as specified and directed 16 S&F aluminium alloy anodised handles, cast type, size 150 mm, ISI-marked, complete all as specified. 17 S&F aluminium alloy anodised handles, cast type, size 100 mm, ISI-marked, complete all as specified. 18 S&F stainless‐steel butt hinges, medium weight, 100 mm long, complete all as specified. 19 M&L for mild-steel flats used as holdfasts, conforming to Fe-310-0 or Fe-410-0, complete all as specified. 20 S&F aluminium alloy floor door stopper, 150 mm long, anodised, with hard-drawn steel spring, complete all as specified. 21 Demolition of brickwork or stone masonry built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facing, dressed stonework and precast concrete articles complete all as specified. 22 M&L brickwork with sub-class “B” bricks, straight or curved on plan exceeding 6 m mean radius, built in CM (1:6), complete all as specified complete all as specified.. 23 M & L for Rendering 15mm thick cement plaster in cement mortor 1:6 on brick or concrete surfaces, surfaces to be finished even and smooth without using extra cement & ht. upto 16th floor of bldg., complete all as specified. (Plaster work carried out in patch work)Note: Quoted rate shall be deemed to include necessary scaffolding. 24 M&L for preparation of newlyplastered surfaces of wall and applying two coats of oil bound distemper over a coat ofprimer over a coat of 1 to 2 mm thick wall care putty (JK/Birla) all as specified and directed. 25 Taking down cement plaster of any description on brick, stone or concrete walls including raking out joints, hacking for key and scrubbing down with water, complete all as specified.Note: Quoted rate shall be deemed to include necessary scaffolding for all heights. 26 M & L for Rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and fair including mixing integral water proofing compound in the proportion as mentioned in manufacturer"s instructions , complete all as specified. (Water proofing compound to be measured and paid for separately). 27 Supply only integral water proofing compound complete all as specified and directed. 28 M&L for Washing, rubbing down and stopping of distempered and painted surfaces ofold wall and apply two coat distemper oil emulsion over a coat of primer over a coat 1 to 2 mm thick wall care putty (JK /Birla ), complete all as specified. 29 Material & labour for newly plasterd surfaces of wall and applying with Acrylic Smooth exterior paint of required shade : (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) all as specified and directed. 30 M&L for complete removal of old decorated surfaces of walls by scrapping old paint withsteel wire brush, wash the surface throughly and applying two coats of acrylic emulsion exterior grade (100%) (1st coat shall be applied by brush/roller, 2nd coat shall be applied by using spray machine over a coat of primer complete including necessary steel scaffolding + green cloth all round the work side for any posititon/height, complete all as specified and directed (For bldg upto GF to max of 7th Floor + upto height of mummty top ).NOTE 1)Work shall be executed by authorised applicator of approved applicator. 2) The tenderer shall note that before quoting his unit rates, all items of work shall be executed in a high-rise building (G + 7 floors) and shall include provision of necessary scaffolding and safety measures.3)Debris shall be removed from time to time as directed by the Engineer-in-Charge. 31 Taking up or down steel / PVC tubing and connections and removing from store of following sizes complete all as directed.Note: Quoted rate shall be deemed to include necessary scaffolding for all heights. 32 S&F in repairs 20mm bore of CPVC pipeshaving thermal stability for hot & cold water supply including allplain and brass threded fittings fixedof required sizes including with all fittings and fixed to wall /ceilingswith suitable clamps,laid in floor or concealed of 20mm size (in high rise building (upto 16th floor)including scaffolding). complete all asspecified and directed by Engineer-in-Charge. 33 S&F in repairs vitreous china squatting pan, Orissa pattern, 580×440mm, white, with integral footrests, including connecting to trap and flushing pipe, making good to floor, complete all as specified. 34 S&F in repairs vitreous china flat-back wash hand basin 550×400mm with brackets, waste coupling 32mm and pillar tap, complete all as specified. 35 S&F in repairs 10 litres PVC low-level flushing cistern with inlet, ball valve, float and handle including connection to pipe, complete all as specified. 36 S&F in repairs plate-rack made of stainless steel, 600×750×0.55 mm, fixed as per manufacturer’s instructions complete all as specified. 37 Supply and fix in repairs 15 mm bore bib cock cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engr-in-Charge. 38 S&F in repairs CP angular stop cock / angle valve 15 mm bore all as specified and directed. 39 Supply and fixingas in repairs brass chromium plated shower rose 125mm size, including fixed to steel tube, complete all as specified and directed by Engineer-in-charge. 40 Supply and fixing150 mm dia stainless steel grating fixed in position complete all as specified. 41 S&F in repairs PVC connection 15mm with PTMT nuts, 600mm long, complete all as specified. 42 S&F in repairs 32/38 mm flexible waste pipe for WHB / urinal / sink, complete all as specified. 43 S&F in repairs aluminium anodised tubular towel rail 20mm dia, D-type, 600mm long between flanges, complete all as specified. 44 Dismantling water tank of capacity exceeding 250L but not exceeding 500L, complete all as specified 45 S&F rotational moulded polythylene water storage loft tanktankof300 ltr capacityhoisted including 20 mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for inron pipe and fixed (minimum weight 210 grms ) all as specified in SSR Part I. 46 S&F in repairsPVC modular section 20mm thick as in profile including "C" channels, aluminium all around the profile all as specified. 47 S&F flat iron for Bands, straps, supports or stays for rainwater, valley gutter, ventilating pipes, including bolts, if required hooks (stay), heavy, for large gates, hook and pintle hinges large hasps and staples, chains,hand made sliding bolts, clamps,hold fasts, wall ties, hooks for hanging fans plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts two way and three way straps, plate washers and similar small articles and straps to be screwed, ends including keys to MS angle or the like item conforming to Fe-290 Gde-E-165 complete all as specified and directed. 48 Dismantling plain or corrugated steel sheeting, any gauge, thickness, any description including Nainital or similar pattern roof coverings or as in valley gutter complete all as specified and directed. 49 S&F pre-painted hot- dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.5 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor for height of building exceeding 10 metres but not exceeding 20 metres complete all as specified and as directed. 50 S&F Plain galvanised mild steel sheeting 1.60mm thick in ridges hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 and opening for rain water pipe to be provided fixed with MS Flat complete all as specified and directed. 51 M&L for preparation of newlysteel surfaces of any description over 10cm in width/ girth and applying two coats ofsynthetic enamel paint over a coat of red oxide complete all as specified and directed. 52 Dismantling of ceiling boards any thickness etc including aluminium grid frame work complete all as specified and as directed. 53 M&L for false ceiling using 600×600 mm panels, 4–6 mm thick, fixed in a grid type suspension system made of powder-coated GI sections consisting of main tee of size 23.50×40×0.63 mm, cross tee of size 23.50×23.50×0.63 mm and angle section of size 19×19×0.63 mm; including 3 mm GI wire for suspension, bolts, nuts, washers, cleats, pin hooks, etc., for securing framework to the ceiling in snap-grid system; including making necessary recesses / cut-outs / holes for light fittings / fans and providing projected patterns where required, complete all as specified and directed by Engineer-in-Charge. 54 Dismantling floor / hearth / wall tiling including cement mortar bedding, removing serviceable tiles to store and disposing debris outside MOD land, complete all as specified & directed. 55 M&L for Non skid coloured ceramic tiles 7 to 8 mm thick (square/Rectanglar) area of each tiles exc 0.11 Sqm but n exc 0.18 Sqm in floor including15 mm thick screed bed or bedding layer for laying floor finishes in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match. all as specified and directed. 56 M&L for coloured glazed ceramic tiles 450x300x7-8 / 350x250 x7-8 mm mm thick but as on vertical surfaces such as skirting/dado including 10 to 15 mm thick backing coatin CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed. 57 M&L for Non - skid Ceramic coloured tiles 7-8mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm tick screed bed in CM 1:6, complete all as directed. 58 Dismantling stone slabs and tiles of any description or thickness in floors laid bedded and pointed in any mortar, complete all as specified. 59 M&L 18-20mm thick Granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window- cills,cooking platforms, working table, floors and like over and including 20 mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match withshade of granite incl moulding and rounding including dismantling of old stone slab, complete all as specified and directed. 60 M&L for machine cut cudappa stone slab 22-25 mm thick laid over screed base in cementand jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including dismantling of old stone slab, complete all as specified and directed. 61 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators,sockets,light fitting etc. removing materials to store for keeping in safecustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc 62 M & L for Point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through & including PVC non-metallic casing and caping of size not less than 25mm width, includingPVC bend,teejointsetc as per site requirementISI marked with accessoriesfixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes / modular boxes surfacing on wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly for the following : 63 (a) One light point controlled by one switch SP one way. 64 (b) One ceiling fan point controlled with one 5A switch 65 (c) One exhaust fan point controlled with one 5A switch 66 (d) One 3 pin socket outlet 5Amps on independant board. 67 (e)One 3 pin socket outlet 5Amps on same board with other switches. 68 (g)One bell pontcontrolled by one bell push 5 amps independent board. 69 Material and Labourpoint wiring for 15 Amps socketcomplete with 2.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic casing and caping of size not less than25 mm dia includingPVC bend,teejointsetc as per site requirement, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes / modular boxes surfacing on wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 2.5 sqmm as earth continuity conductor connected to common earth as earth dollycomplete all as specified and directed. 70 S&F Modular Switch , 6Amp, One way, 1 module, ISI marked complete all as specified and directed. 71 S&F modular switch, 16 A, 1-way, 1-module, ISI-marked, complete all as specified and directed. 72 S&F modular type bell push, 6 A, 1-module, ISI-marked, complete all as specified and directed. 73 S&F in replacement, electric bell 230 V AC, single pole, ding-dong type, ISI-marked, complete all as specified and directed. 74 S&F modular socket, 6 A, 2/3-pin combined, 2-module, ISI-marked, complete all as specified and directed. 75 S&F modular socket, 16 A, 6-pin combined, 2-module, ISI-marked, complete all as specified and directed. 76 S&F modular type electronic fan regulator, 120 W, 5-step, 230 V AC, 2-module, ISI-marked, complete all as specified and directed. 77 S&F ceiling rose, surface type, bakelite, ISI-marked, flush type, 3 terminals, complete all as specified. 78 S&F modular white cover plate with 2-module frame, ISI-marked, complete all as specified and directed. 79 S&F modular white cover plate with 3-module frame, ISI-marked, complete all as specified and directed. 80 S&F modular white cover plate with 6-module frame, ISI-marked, complete all as specified and directed. 81 S&F modular white cover plate with 8-module frame, ISI-marked, complete all as specified and directed. 82 S&F modular metal flush box 2 module, ISI-marked, including cutting hole in wall/ceiling/pillar and making good disturbed surfaces to match existing, complete all as specified and directed.. 83 S&F modular metal flush box 3 module, ISI-marked, including cutting hole in wall/ceiling/pillar and making good disturbed surfaces to match existing, complete all as specified and directed.. 84 S&F modular metal flush box 6 module, ISI-marked, including cutting hole in wall/ceiling/pillar and making good disturbed surfaces to match existing, complete all as specified and directed.. 85 S&F modular metal flush box 8 module, ISI-marked, including cutting hole in wall/ceiling/pillar and making good disturbed surfaces to match existing, complete all as specified and directed.. 86 S&F baton-type, integral polycarbonate LED channel light, 1×18 W, min 120 lumen/watt, with acrylic diffuser, internal pre-wiring and connections using suitable size flexible copper conductor, complete all as specified and directed. 87 S&F baton-type, integral polycarbonate LED channel light, 1×10 W, min 120 lumen/watt, 2-ft length, with acrylic diffuser, internal pre-wiring and connections using suitable size flexible copper conductor, complete all as specified and directed. 88 S&F lamp holder, PVC/polycarbonate type, with cord grip and cap, suitable for pendant fittings, complete all as directed. 89 S&F LED lamp, 12 W, 240 V, single-phase, 50 Hz, output ≥1450 lumen, complete all as specified 90 Taking down old unserviceable sub-main cable of any size/capacity, complete all as specified and directed. 91 S&F sub-main wiring with proper colour coding, comprising 2 runs of FRLS, 1100 V, stranded copper conductor cable of 6 sqmm size and 1 run of 6 sqmm FRLS stranded copper conductor (green) for earth, laid in/including ISI-marked PVC non-metallic casing/capping minimum 25 mm size, complete all as specified and directed.Note: (a) Two runs of 6 sqmm cable + one run of 6 sqmm earth + one run of PVC casing/capping shall be measured as one run. (b) Each sub-main wiring shall run in separate PVC conduit. 92 S&F sub-main wiring with proper colour coding, comprising 2 runs of FRLS, 1100 V, stranded copper conductor cable of 4 sqmm size and 1 run of 4 sqmm FRLS stranded copper conductor (green) for earth, laid in/including ISI-marked PVC non-metallic casing/capping minimum 25 mm size, complete all as specified and directed.Notes:(a) Two runs of 4 sqmm + one run of 4 sqmm earth + one run of PVC casing/capping measured as one run(b) Each sub-main wiring shall run in separate PVC conduit 93 Taking down MCB DB of any type, single-phase, including disconnecting all circuits and removing MCBs, complete all as specified. 94 S&F sheet-metal enclosure, double-door MCB DB SPN, 8-way, 240 V, with 200 A rated busbar; fixed in concealed position and providing flexible conduit as required near DB for cables/wires, complete all as directed. 95 S&F MCB SPN 40–63 A, 240 V, 10 kA, ‘C’ curve, complete all as specified & directed. 96 S&F MCB SP 6–32 A, 240 V, 10 kA, ‘C’ curve, complete all as specified & directed. 97 Taking down ceiling/exhaust fan of any size, sealing cable ends, dismantling blades safely, and depositing fan & blades in MES E/M store for safe custody, complete as directed. 98 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all asspecified and directed by the Engineer-in-Charge. 99 S&F exhaust fan, engineering-plastic body with louvers, 230 V, 50 Hz, copper-wound motor, 1200 RPM, 250 mm sweep, complete all as specified and directed. 100 M & L for one coat of synthetic enamel paint by spray painting , replacing existing nut bolts pins, rubber bush, capacitor, bearing, m bush, frastner complete including taking down and refixing in existing position and testing complete all as specified and directed by Engr in charge 101 S&F in replacement, plug & socket unit in sheet-metal enclosure with MCB SP 20 A, 240 V, complete with metal-clad socket, all as specified and directed. 102 Material & Labour for Earthing with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, burried directely in ground (earth pit not less than 2.5 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 32 x 6 mm with the help of bolts, nuts, check nuts and washers of galvanised iron or steel, including necessary excavation, PCC 1:3:6 type D2 and PCC cover 1:2:4 type B1 watering arrangement with GI pipe funnel, jali,and cast iron coverfixed on topof pit complete all as specified and shown in electrical plate No.3 including connection to the earthing test point andtesting on completion. 103 Supply, installation, testing and commissioning of LT Panel (meter cabin panel) mounted on angle-iron frame of size 40×40×5 mm, grouted on floor; cubical outdoor type, suitable for 415 V, 3-phase, 4-wire system; fabricated from 3.15 mm thick CRCA sheet; IP-65 rated, weatherproof, vermin-proof, factory-fabricated and CPRI-approved; provided with front-opening hinged doors with locking arrangement; powder-coated finish; internal GI partitioning; individual compartments for MCCBs, electronic meters and 150 A rated busbar; top/bottom cable entry; including disconnecting cable connections and electronic meters from old LT panel and fixing/connecting in new installed panel with suitable lugs/thimbles, necessary fabrication work, PCC foundation in cement concrete 1:2:4 using 20 mm graded stone aggregate; shifting of existing (old) LT Panel, if any; making arrangement for fixing of panel and making good disturbed surfaces to match existing; complete all as specified and directed.The LT Panel shall comprise of the following:(a) MCCB, adjustable thermal–magnetic type, ICS = 100% of ICU, 4-pole, 100 A, 16 kA – 01 No(b) MCB, DP, 63 A, 10 kA, ‘C’ curve – 16 Nos(c) Sheet-metal enclosure, 2-way, without busbar – 16 Nos(d) Electrolytic grade copper bus-bars, 150 A rated, colour-coded (R-Y-B-N) using heat-shrunk sleeves – 1 Set• Mounted on SMC/DMC supports• Fully shrouded(e) Digital ammeter with CTs (suitable range) – 01 No(f) Digital voltmeter – 01 No(g) Phase indicating lamps – R-Y-B – 1 Set(h) Provision for fixing 16 Nos. digital/electronic energy meters removed from old panel including providing protection cover & vision glass – 16 Nos(i) M&L for 2-core, 10 sqmm, multi-stranded copper conductor cable, 1100 V grade, from busbar to electronic energy meters using suitable size copper thimbles/lugs and cable glands – Complete(j) Fixing & connection of sub-main cable (outgoing) using 2-core, 6 sqmm copper conductor cable from energy meter, completeall as specified. 104 Supply, laying including testing and commissioning PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 3.5 core 50 Sqmm laid through pipe /ducts or fixed on wall etc complete all connections to LT panel with proper size glands & lugs all as specified & directed. 105 Supply, laying including testing and commissioning XLPE insulated, PVC sheathed, armoured LT power cable, aluminium conductor, 1100 V grade, 3.5-core, 50 sqmm, laid through pipe/ducts or fixed on wall, including suitable size cable glands, lugs/thimbles, and making proper connections to LT panel, complete all as specified and directed. 106 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth in hard/densesoil for laying of cable/ GI pipe and getting out complete all as specified and directed. 107 Returning, filling in including spreading levelling watering well rammingin layers not exceeding 25cm each complete all as specified and directed by Engr in Charge. 108 Removing surplus soil to a distance outside MD land and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr in Charge. 109 Supply and layingHDPE pipe, 6 kg/sqcm pressure rating, 100 mm dia (or nearest available size) including necessary bends, elbows, tees, etc., for cable protection, complete all as specified and directed by Engineer-in-Charge. 110 Supply and layingHDPE pipe, 6 kg/sqcm pressure rating, 50 mm dia (or nearest available size) including necessary bends, elbows, tees, etc., for cable protection, complete all as specified and directed by Engineer-in-Charge.
|