Bids Are Invited For Acquisition Of An X-Ray Device Resulting From Parliamentary Amendment — Proposal No. 09 ... in Brazil
Tender Notice
TenderID
105526609
Tender Brief
Bids Are Invited For Acquisition Of An X-Ray Device Resulting From Parliamentary Amendment — Proposal No. 09032025-083826/2025, Intended For The Needs Of The Luiza Pereira De Carvalho Municipal Hospital, Municipality Of Caetés/Pe.
X-Ray Machine - Fixed Digital - High Frequency Microprocessed Generator. Power Of At Least 50 Kw. Variable Voltage That Minimally Meets The Range From 40 Kv To 125 Kv Higher. Variable Current Between 10 Ma To 500 Ma Or Greater. Minimum Exposure Time From 5Ms Or Less, To 4S Or Greater. With Variable Mas In The Range Of 10Mas Or Less To 500 Mas Or Greater. X-Ray Tube, Fine Focus Of 0.6Mm And Coarse Focus Equal Or Greater Than 1.0 Mm; Rotating Anode Minimum 3,000 Rpm At 60 Hz; Minimum Anode Thermal Capacity Of 150 Khu. Insertion Of Additional Cu Or Al Filters. Emitter Port Station With Their Appropriate Characteristics; Column With Longitudinal Displacement From 125 Cm; Tube Rotation About Horizontal Axis +/-90 Degrees With Locks At 0 Degrees, +/- 90 Degrees; Luminous Diaphragm With Manual Or Automatic Collimation; Electromagnetic Braking System. Bucky Table With Anti-Diffusion Grid Of At Least 40Lp/Cm, Focus Of At Least 100 Cm, 8:1 Or 10:1; Floating Top With Minimum Dimensions Of 200 Electromagnetic Braking System. Weight Capacity Supported By The Table Of At Least 150 Kg. Bucky Mural Vertical Displacement Referenced In The Center Of The Grid Between 60 Cm (Or Less) And 170 Cm (Or Greater) From The Floor, Approximately, Equipped With An Electromagnetic Or Mechanical Brake System. Mural With Anti-Diffusion Grid Of At Least 40Lp/Cm, Focal Distance Between 100 Cm And 180 Cm; With Location/Centering Cross Printed On The Top Of The Bucky. Flat Detector With Approximate Dimensions Between 34 X 42 Cm Or Larger. Wired Or Wireless (Mobile) Detector And Cesium Iodide Scintillator, Enabling Examinations On The Table, On The Bucky Wall Or Outside The Table, Stretcher And Wheelchair. Active Matrix Of At Least 1990 X 2048 Pixels. Post-Processed Image Depth Of At Least 14 Bits. Maximum Pixel Size 175 Micrometers. The Equipment Must Enable Manipulation, Printing And Transmission Of, 11/11/2025 - 10:03:19, 24/11/2025 - 09:24:21
Contact Information
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 105526609
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.