Tender For Repair/Maintenance Of Stp Plant Including Misc Work At Af Stn Naliya; 1 Cleaning oftanks after desludging from sewage tanks (Stilling chamber, Bar & screen Chamber) atSTP Plant of capacity 1.5 MLD etcshall be carried out with water and chemical as applicable and complete white washfrom inside after cleaning the tanks and dates of cleaning shall be marked on tank etc complete all as specified and directed. Note:-(i) Rates forDewatering and desludging of tanks including T&P and safety equipments are included in above item.(ii) Cleaning of each tank will be measured and paid seperately. 2 Cleaning oftanks after desludging from sewage tanks (Equilisation Tank, Sedimentation Tank, MBBR Tanks, treated water tank, Chlorine Contact Tank, Sludge Holding Tank) atSTP Plant of capacity 1.5 MLD etcshall be carried out with water and chemical as applicable and complete white washfrom inside after cleaning the tanks and dates of cleaning shall be marked on tank etc complete all as specified and directed. Note:-(i) Rates forDewatering and desludging of tanks including T&P and safety equipments are included in above item.(ii) Cleaning of each tank will be measured and paid seperately.(iii) Safety of manpower involved will be of prime importance and contractor shall make arrangement s considering safety of manpower 3 Material and labour for cleaning of main incoming sewage collection tank/booster tanks, including necessary T&P such as pump set for De-watering and cleaning upto bottom of the well by means of equipment with complete safety equipment and masks for the persons doing the job and lifting of sludge by means of Hydra and taking out all clay/mud/sludge/grit/stone pieces and other material deposited in the sewage well during course of time and removing deposited material to outside the premises of the station including necessary transportation for taking out from the site of the well complete all as specified and directed by Engr-in-charge.Note :- No direct manpower to be introduced inside the sewage well as per the goverment norms. 4 Material and labour for carrying out the Tests of treated water from NABL approved lab every month and maintain the record of treated sewage at Each STP Plant as per frequency :- (i) PH Valve(ii) Odour(iii) Sulphate(iv) Total Suspended Solids (v) BOD(vi) COD(vii) Oil & Grease(viii) Total Ammonia(ix) E Coli (x) Nitrate CN(xi) Total Coliform BacteriaNote:- (i) Test report should be submiited at the end of qtr/month by contractor.(ii) rate quoted shall deemed to be included for cost of sterilised bottle and to and from transportaion charges for collection samples upto Lab. 5 Supply only greasing for bearing of centrifugal Pumps all as specified and as directed. 6 Material and labour for repair & overhauling of 30 HPelectrical induction motor, 3 phase, 415 volts including disconnecting all electrical connections, decoupling from pump, taking down the motor from foundation, cleaning and varnishing the stater & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignmentconnecting all electrical connections, checking the vibrations, RPM, DOR,testing on full load complete all as specified and directed. 7 Material and labour for repair & overhauling of 3 to 7.5 HP, 3 Phase monoblock pump set, taking out impeller, cleaning, descaling & greasing to bearings incl replacement of unserviceable parts such as bearings, gland flange,etc.Cleaning and varnishing the starter and rotar, winding, heating and drying replacement of burnt terminals of motor assembling in the pump with new packing materials nuts, bolts, washers checking alignmentconnecting all electrical/water connections,checking the vibrations & alignment, RPM,DOR,testing the pump sets of on full load, complete all as specified and directed.Notes:-(i) Cost of smallU/S parts such as new packing materials, nuts, bolts & washers, gland bolt & packing, coupling bushes , coupling bolts shall deemed to be inclusive inquoted rate. (ii) Major unserviceable spares as listedbelow shall be measured and paid separately. 8 All as per serial item number 7.00 here-in-before but of capcity 0.5 to 1 HP, 3 Phase 9 Material and labour in repairs for rewinding of 30 HP , 3 Phase capacity induction motor by means of cutting and removing existing burnt out winding completely cleaning and repair of slots and rewinding with new copper wire of existing gauge and size / turns, varnishing with class "B" insulation, balancing of shaft, incl replacement of UNSV connection plate / terminal point as per site requirement, assembling the motor including transportation, testing as per the specified RPM at workshop complete all as specified and directed. 10 All as per serial item number 9.00 here-in-before but of capcity 3 HP-7.5 HP, 3 Phase 11 All as per serial item number 9.00 here-in-before but of capcity 0.5-1 HP, 3 Phase 12 Supply and fix in repair of following parts for existing monoblock pump set electric driven 3 phase 415 volt 3 to 7.5 HP complete all as specified and directed. 13 Motor bearing with housing . Make : SKF/NBC/TATA/FAG/ UBC. 14 Motor cooling fan 15 Cover bolts & washers 16 Impellaras per existing model complete 17 SS Sleeve (Gland Sleeve) 18 Pump shaft with studs and nuts for pump body. 19 Shaft seal of existing size 20 Motor connection plate with cover plate 21 Material and labour in repairs of screw type sludge pump as per existing model including replacement of unserviceable shaft, bearing, rubber liner, joints, seals, drive shaft, universal joints, motor adapter, unserviceable parts such as stator, screw, bearings, shafts (drive shaft/intermediate shaft), seals (mechanical/lip), couplings, discharge/suction nozzles, liner, impeller, throatbush and timing gears, mechanical seals all etc complete and any spares required to be incorporated to be included in quoted rate to make functional complete all as specified and directed. 22 Material and labour for lifting of submersible pump set of 40HP capacity carefully from open well/UG Sump/SWT alongwith existing submersible cable, MS/GI/HDPE Column pipe of any dia and shifting of column pipe, pumpset and disconnecting of submersible cable aside for reuse and lowering into well/sump/SWT after carying out necessary repair work including jointing of submersible cable with water proof jointing kit, testing, binding of submersible cable with column pipe by using aluminium wire complete and testing complete all as specified and directed.Note :- (i) The quoted rate deemed to be included the cost of replacement of rubber gaskets, nuts, bolts, washers aluminium wire etc.(ii) Any damage to pump set pipe submersible cable etc while taking out and lowering of pump set will be repaired/replaced by contractor on his own cost and GE"s decision shall be final and binding in this regard. 23 Material and labour for complete opening of horizontal submersible motor 40 HP for repair /replacement of unserviceable worn out bearing/worn out unserviceable shaft/burned out copper winding /worn out strainer/bush/sleeve/thrust pad/thrust bearing/thrust bearing lock nut etc including transportation complete all as specified and as directed.Note :- (i) The quoted shall be inclusive of transportation of pump set from pump house site to workshop and back to pump house site after necessary repairs.(ii) The quoted shall be inclusive of balancing of shaft through lathe work incl welding wk if any required as per requirement, replacement of pump seal, replacement of wornout nut, bolts, washers etc complete.(iii) Winding shall be measured and paid separately. 24 Material and labour for rewinding the submersible motor of40HP capacity by means of cutting and removing existing burnt out winding completely cleaning and repair of slots and rewinding with new PVC insulated copper wire of existing gauge and size / turns, balancing of shaft, testing as per the specified RPM at workshop complete all as specified and directed. 25 Supply and fix in repair of following parts for existing submersible pump set electric driven 3 phase 415 volt 40 HP complete all as specified and directed. 26 Pump bearing Make : SKF/NBC/TATA/FAG/ UBC. 27 Pump bush 28 SS sleeve 29 Impellaras per existing model complete 30 Pump shaft 31 Shaft seal of existing size 32 Material and labour for Lifting of non-clog pump set of 10 HP to 15 HP capacity carefully from sewage well alongwith existing submersible cable, MS/GI/HDPE Column pipe of any dia and shifting of column pipe, pumpset and disconnecting of cable aside for reuse and lowering into well after carying out necessary repair work including jointing of submersible cable with water proof jointing kit, testing, binding of submersible cable with column pipe by using aluminium wire complete and testing complete all as specified and directed.Note :- (i) The quoted rate deemed to be included the cost of replacement of rubber gaskets, nuts, bolts, washers aluminium wire etc.(ii) Any damage to pump set pipe submersible cable etc while taking out and lowering of pump set will be repaired/replaced by contractor on his own cost and GE"s decision shall be final and binding in this regard. 33 All as per serial item number 32.00 here-in-before but of capcity 3 to 5 HP 34 Material and labour for complete opening of non-clog pump motor 10 HP to 15 HP for repair /replacement of unserviceable worn out bearing/worn out unserviceable shaft/burned out copper winding /worn out strainer/bush/sleeve/thrust pad/thrust bearing/thrust bearing lock nut etc including transportation complete all as specified and as directed.Note :- (i) The quoted shall be inclusive of transportation of pump set from pump house site to workshop and back to pump house site after necessary repairs.(ii) The quoted shall be inclusive of balancing of shaft through lathe work incl welding wk if any required as per requirement, replacement of wornout nut, bolts, washers etc complete.(iii) Winding shall be measured and paid separately. 35 All as per serial item number 20.00 here-in-before but of capcity 3 to 5 HP 36 Material and labour for rewinding the non-clog motor of10HP to 15 HP capacity by means of cutting and removing existing burnt out winding completely cleaning and repair of slots and rewinding with new PVC insulated copper wire of existing gauge and size / turns, balancing of shaft, testing as per the specified RPM at workshop complete including replacement winding oil and oil seal complete all as specified and directed. 37 All as per serial item number 22.00 here-in-before but of capcity 3 to 5 HP 38 Supply and fix in repair of following parts for existing nonclog pump set electric driven 3 phase 415 volt 10 HP to 15 HP complete all as specified and directed 39 Pump bearing Make : SKF/NBC/TATA/FAG/ UBC. 40 Pump bush 41 SS sleeve 42 Impellaras per existing model and complete 43 Pump shaft 44 Shaft seal /oil seal of existing size 45 Supply and fix in repair of following parts for existing submersible pump set electric driven 3 phase 415 volt 3 HP to 5 HP complete all as specified and directed. 46 Pump bearing Make : SKF/NBC/TATA/FAG/ UBC. 47 Pump bush 48 SS sleeve 49 Impellaras per existing model and complete 50 Pump shaft 51 Shaft seal of existing size 52 Material and labour for Preventivemaintenance of electronicChlorinedosing plant for water disinfactant of cap upto 12/25 LPH any makeincluding checking serviceability of injector, valves, discharge and suction tube, knob for speed/stroke, including replacement of gland packing (for screw type chlorine pump), repair/replacement of suction/delivery PVC pipe line complete all as specified and directed. 53 Supply and fix in replacement of flat/V belt/coupling coupled with air blower motor or pump motor/sludge making motor set as per existing complete all as specified and directed. 54 Material and labour for taking out NRV of 80mm/100mm/125mm/150mm dia from open well including taking column pipe of any size and length, disconnecting of NRV from column pipe, reconnecting of NRV after servicing/repairing, lowering of NRV duly connecting the column pipe, replacement of worn out nut, bolts, washers etc complete all as specified. Note :- The quoted rate shall be inclusive of necessary T&P required for lifting and lowering of NRV from open well/neccessary drain out of water as required as per site requirement. 55 Supply, fixing, jointing and testing of100mm/125mm Cast iron Non Return valve without by pass arrangement , Swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 complete including taking out unserviceable NRVcomplete all as specified and directed for following sizes of pipe:-Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.(ii) The quoted rate shall be inclusive of taking out GI/MS/HDPE pipe from open well, disconnecting of unserviceable NRV, replacement of unserviceable nut, bolts, washers etc, lowering of pipe duly assembleed the new NRV etc complete.(iii) The quoted rate shall be inclusive of T&P required for taking out column pipe of any capacity and size of any length from open well. 56 All as per serial item number 29.00 here-in-before but150 mm bore 57 Supply and fix in repairs butterfly valve, PN 1.6 conforming to IS 13095/BS EN 593 BS 5155) (wafer type)SG Iron Construction, SG Iron Disc which is accurately guided between the two stems, integrally moulded rubber lining (EPDM/Nitrile/Neoprone) of size80 mm (3”) dia complete all as specified and directed. 58 All as per serial item number 31.00 here-in-before but 100 mm (4") bore 59 All as per serial item number 31.00 here-in-before but 150 mm (6") bore 60 All as per serial item number 31.00 here-in-before but 200 mm (8") bore 61 Supply and fixin repair MCCB 3 pole , 415 volts , fixed thermal and fixed magnetic setting 63 Amps to 100 Amps with braking capacity 16 KA, Ics=100% Icu, complete including replacement of u/s lugs, spreader connector all as specified and as directed . 62 All as per serial item number 35.00 here-in-before but 125 Amps , with breaking capacity 16 KA. 63 Supply and fix in repair MCCB 4 pole , 415 volts , fixed thermal and fixed magnetic setting upto 160 Amps with braking capacity 16 KA Ics=100% Icu, complete including replacement of u/s lugs, spreader connector complete all as specified and directed. 64 All as per serial item number 37.00 here-in-before but 200 Amps , with braking capacity 35 KA. 65 Supply and fixin replacement of start push button of Green colour as per site requirement all etc complete all as specified and directed. 66 Supply and fixin replacement of stop push button of Red colour as per site requirement all etc complete all as specified and as directed. 67 Supply and fixin replacement of motor ON indiating light of green colour as per site requirement all etc complete all as specified and directed. 68 Supply and fixin replacement of motor Trip indiating light of yellow colour as per site requirement all etc complete all as specified and directed. 69 Supply and fixin replacement of neon LED light of Red/Yellow/Blue colour as per site requirement all etc complete all as specified and as directed. 70 Supply and fixin replacement of rotary type selector switchall etc complete all as specified and directed. 71 Supply and fix in repairs Power contactor TP AC-3 duty with 240 VAC Coil of capacity 50 Amps(MNX 50) including with all necessary internal electrical connections and taking out unserviceable all etc complete all as specified and directed. 72 Supply and fix in repairs Power contactor TP AC-3 duty with 240 VAC Coil of capacity 40 Amps(MNX 40)incl with all necessary internal electrical connections and taking out unserviceable all etc complete all as specified and directed. 73 Supply and fix in repairs Power contactor TP AC-3 duty with 240 VAC Coil of capacity 32 Amps (MNX 32) with add-on blocks 1NO/1 NC -01 Nosincl with all necessary internal electrical connections and taking out unserviceable all etc complete all as specified and directed. 74 Supply and fix in repairs Power contactor TP AC-3 duty with 240 VAC Coil of capacity 18 Amps (MNX 18) with add-on blocks 1NO/1 NC -01 Nosincl with all necessary internal electrical connections and taking out unserviceable all etc complete all as specified and directed. 75 Supply and fix in repairs Power contactor TP AC-3 duty with 240 VAC Coil of capacity 12 Amps (MNX 12) with add-on blocks 1NO/1 NC -01 Nosincl with all necessary internal electrical connections and taking out unserviceable all etc complete all as specified and directed. 76 Supply and fix in repairs Power contactor TP AC-3 duty with 240 VAC Coil of capacity 9 Amps (MNX 9) with add-on blocks 1NO/1 NC -01 Nosincl with all necessary internal electrical connections and taking out unserviceable all etc complete as specified and directed. 77 Supply and fix in repairsthermal overload relay of capacity 9-15 (MN-2) Amps with all necessary internal electrical connection and taking out unserviceable all etc complete all as specified and directed. 78 Supply and fix in repairsthermal overload relay of capacity 4.5-7.5 (MN-2) Amps with all necessary internal electrical connection and taking out unserviceable all etc complete all as specified and directed. 79 Supply and fix in repairsthermal overload relay of capacity 2-3.3 (MN-2) Amps with all necessary internal electrical connection and taking out unserviceable all etccomplete all as specified and directed. 80 Supply and fix in repairs repairs Single Phasing Preventer Relay type VSP-II, 415V including necessary internal electric connection with size copper wire complete all as specified and directed. 81 Supply and fix in repairs electronic timer for star-delta time delay 30 to 120/3 to 30 seconds all as per existing sample complete including internal electric connection with suitable size copper wire complete as specified and directed. 82 Supply and fix in repairs ammeter 415 volt, 3 phase digital typeincluding necessary internal electric connection with suitable size copper wire & modification required for fitment as per site requirement complete all as specified and directed. 83 Supply and fix in repairs voltmeter 415 volt,3 phase 0 to 500 volts rating, analog type including necessary internal electric connection with suitable size copper wire & modification required for fitment as per site requirement complete all as specified and directed. 84 Supply and fixin repairs 240V, 10KA "C" curve miniature circuit breaker (MCB) ofsingle pole and 6 Amps to 32 Ampscurrent carrying capacity in the MCB DB/LT starter panelcomplete with connection testing and commissioning complete all as specified and directed. 85 Supply and fix in repairs 415V 10KA "C" curve miniature circuit breaker (MCB) of TPN and16 Ampsto 40 Amps current carrying capacity in the DB/LT starter panelcomplete with connection testing and commissioning complete all as specified and directed. 86 Supply and fix in replacement of terminal strip6 way all etc complete including electrical connection all as specified complete all as specified and directed. 87 Supply and fix in replacement of terminal strip 3way all etc complete including electrical connection all as specified complete all as specified and directed. 88 Material and labour for preparation of old painted surfaces of centrifugal pump set of 30 HP capacity and applying two coats ofsynthetic enamel paint over a coat of red oxide primer complete all as specified and directed. 89 All as per serial item number 62.00 here-in-before but of capacity 5 to 7.5 HP 90 All as per serial item number 62.00 here-in-before but of capacity 0.5 to 1 HP 91 Labour only for attending of Electric compliantsof existing STP panels /Sewage well LT starter Panels/CF Motors/Non-clog motors/Horizontal submesible, including connecting electrical accessories / spares of STP installation, electrical fitting & short circuits in panel/CF Motors/Submersible motors/ Panelscomplete all as specified and directed.(Any material required for attending complaints shall bemeasured & paid separately under respectvie item )Notes :-(i)The complaints shall be attended and the defects shall be rectified by a team of expert and experiencedelectrician as applicable assisted with adequate No of helpers as directed by Enginner-in-charge.(ii)The complaints shall be attended and defect shall be rectified within 08 hrscommencing from date and time of notifying the complaint failing which a penalty @ Rs 250/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor"s dues.Contractor rep shall be available wef 0800 hrs to 2000 Hrs to receive and notify the complaint (iii)In case, after checking and attending the defect, it is not possible to rectify the defects within 08 hrs the facts shall be brought to the notice of Engineer-in -charge by the contractor /his rep . If Engineer -in-charge is satisfied with contractors view, no recovery will be made.(iv)Any types of machinery/, T & Prequired for attending the complaints shall be provided by the contracor. The quoted rate shall be inclusive of replacement of burnt out lugs, refreshing of burnt out cable, reconnecting, meggering, fault locating etc complete.(v)The elecrician shall always be in possession of all Electrician tools, LT Megger, Earth tester , Multimeter , Crimping tool, insulation tape, Hand gloves etc required at site. 92 Material and labour for repairs of Mild Steel Structure with framed work such grills, gratings etc with ends of bars shouldered and/or rivetted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work, portions framed and hung gates, including pintle hinges, stops, hand made sliding bolts etc as conforming to Fe290, Gde E-165 including two coats of paints of approved colour and including one coat of red oxide primer complete all as specified and as directed. 93 Material and labour in repairs of gravels and sand from filter media vessels including painting of the vessel with synthetic enamel paint both inside and outside surface all etc complete and supply and lay the media as per description give below :-Bottom layer: Gravel of 20-40mm nominal size (Thickness of layer as per site requirement).Third layer :Gravel of 12-20mm nominal size. (Thickness of layer as per site requirement)Second layer : Gravel of 2-6mm nominal size. (Thickness of layer as per site requirement)Top layer : Silica sand (1-2mm size). (Thickness of layer as per site requirement) 94 Material and labour in repairs activated carbon (IV-900) from carbon filter, cleaning the vessels from inside, painting the vessel with bitumen paint all etccomplete and supply and set activated carbon suitable for treatment plant installed at STP as per site requirement complete all as specified and directed. 95 Supply and lay in repairs of float suspended plastic carriers with large protected surface areas for the growth of bacteria and proper decompoistion of sludge in all two MBBR tanks complete all as specified and directed. 96 Excavation in trenches not exc 1.5 M wide and not exc 1.5 M indepth for pipe line, etc in hard/dense soil getting out and levelling of bottom surface to required level complete all as specified and directed. 97 Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 Cm thick soft / loose soil complete all as specified and directed. 98 Removing excavated material (Soils) from site to a distance not exc 50 M away and depositing where directed at a level not exc 1.5mtr above the starting point complete all as specified and directed. 99 Taking up or down GI tubing of size 15mm bore and connections from trenches / wall / floor complete all as specified and directed. 100 All as per serial item number 73.00 here-in-before but of size 20mm bore 101 All as per serial item number 73.00 here-in-before but of size 25mm bore 102 All as per serial item number 73.00 here-in-before but of size 50mm bore 103 All as per serial item number 73.00 here-in-before but of size 80mm bore 104 Taking up GI/ Cast Iron /Ductile Iron water mains of size 100mm dia (including all fittings) with spigot & socket ends and lead/tyton joints including burning out lead joints and recovering lead complete all as specified and directed. 105 All as per serial item number 78.00 here-in-before but of size 150mm bore 106 All as per serial item number 78.00 here-in-before but of size 200mm bore 107 Supplying, Laying, jointing, testing and commmisioning of DI Pipe 100mm dia as per IS 8329, class K-7 with inside cement mortar lining with spigot and socket ends laid in trenches complete all as specified and directed.Note : - Joints shall be measured and paid separetely 108 All as per serial item number 81.00 here-in-before but of size 150mm bore 109 All as per serial item number 81.00 here-in-before but of size 200mm bore 110 Supply and laying GI pipe 100mm dia medium grade ISI marked including all fittings in old/new position including fittings like bends, tees and welding wk as per site requirement as in walls/ceilling/trenches,complete all as specified and directed. 111 All as per serial item number 84.00 here-in-before but of size 150mm bore 112 Material and labour for refixing/relaying of old CI/DI/GI pipe and connections in new or old position in trench/floor of size 100mm dia all etc complete as specified and directed. 113 All as per serial item number 86.00 here-in-before but of size 150mm bore 114 All as per serial item number 86.00 here-in-before but of size 200mm bore 115 Supply and fixing in repairs of rubber tyton ring/rubber gasket for 100mm dia CI/DI pipe complete all as specified and directed 116 All as per serial item number 89.00 here-in-before but of size 150mm bore 117 All as per serial item number 89.00 here-in-before but of size 200mm bore 118 Material and labour in repairs of CI/DI fittings/specials such as Tees, bends (any type, radius and angle ) tapers any type, collars,tail pieces,caps and plugs up to 200 mm bore confirming to IS: 9523 complete all as specified and directed. 119 Supply and laying GI pipe of size 15mm bore, medium grade ISI marked including all fittings in old/new position as in walls and ceilling/trenches,complete all as specified and directed. 120 All as per serial item number 93.00 here-in-beforebut of size 20mm bore 121 All as per serial item number 93.00 here-in-beforebut of size 25mm bore 122 All as per serial item number 93.00 here-in-before but of size 50mm bore 123 All as per serial item number 93.00 here-in-beforebut of size 80mm bore 124 Supply and fixin repairs PVC heavy duty sprinklers suitable for 25 mm dia pipe pop up type 360 degree & connected accessories all as per site requirement including taking out old u/s sprinklers complete all as specified and directed. 125 Supply and fixing in repairs 15 mm bore Bib tap standard of PTMT any colour high pressure screwed for male/ female treaded of size 15mm bore complete all as specified and directed 126 Supply and in fix in repairs ofUPVC pipe 15 mm bore, SCH 40 type with necessary fittings , all as required at site including taking down old unserviceable all etc complete all as specified and directed. 127 All as per serial item number 100.00 here-in-before but of size 20mm bore 128 All as per serial item number 100.00 here-in-beforebut of size 25mm bore 129 All as per serial item number 100.00 here-in-before but of size 50mm bore 130 Supply and fixing of UPVC ball valves of size 50mm dia all etc complete as per requirement at site including taking out old u/s ball valves complete all as specified and directed. 131 All as per serial item number 104.00 here-in-before but of size 25mm bore 132 All as per serial item number 104.00 here-in-before but of size 20mm bore 133 Supply & topup in replacement suitable compressor oil in air blowerat STP complete all as specified and directed. 134 Supply only chemicals PAC (Sodium Hypo chlorite) required to achieve disired parameter of treated water for operation of the plant, at least one month requirement of the materials required shall be kept at site at a time etc complete all as specified and directed. 135 Supply only chemicals PE (Poly Electrolite) (STP Bio culture-Microbzz) duly packed in 1 Kg pouchesrequired to achieve disired parameter of treated water for operation of the plant, at least one month requirement of the materials required shall be kept at site at a time etc complete all as specified and directed.Make : Microbzz/Greentreat 136 Supply and fix in repairs of flexible pipe of 40/25 mm bore complete all as specified and directed. 137 Supply and fix in repairs air blower pressure release valve 3" for root blower of capacity 760m3/hr, pressure rating upto 0.65 Kg/Cm2 for STP air blower application all etc complete as specified and directed. 138 Supply only 15mm bore gun metal gatevalves/Check Nut valves with iron wheel head screwedboth ends for iron pipe , ISI marked , as per IS : 778 complete including taking out old u/s valves complete all as specified and directed. 139 All as per serial item number 112.00 here-in-before but of size 20 mm bore 140 All as per serial item number 112.00 here-in-before but of size 25 mm bore 141 All as per serial item number 112.00 here-in-before but of size 50 mm bore 142 Material and labour in replacement of stainless stell pipe of 100/80mm dia including necessary welding, SS flanges, SS bend, SS nut, bolts, washer, gasket all etc as per site requirement complete all as specified and directed. 143 Complete removal of the wild grass/ vegetation from surrounding area of STP installations area and making the surface clear and plain and spraying roundup chemical on the same clean areaas directed after removing and depositing the same at a distance not less than 50 mtr away from the site complete all as specified and directed.Note:- (i) T&P machinary will be provided by the contractor.(ii) Cleaning should be done as directed by Engr-in-Charge. 144 Material and labourfor removing old paint from surface ofLT panelby scraping,rubbing and making good surface for painting and applyingpowder coated spary painting with existing colourcomplete as specified and directed. 145 Scraping old existing paint from pipes of different sizes including making smooth surface and primer and applying two coat of synthetic enamel paint of existing/approvedcolour complete all as specified and directed. 146 Labour only for excavation muddy soil from pipe line leaked area upto desired depth including fixing clamp/collar joint/Lead Joint /new pipe/fittings of required type and size of pipe line, and stopping of leakage and checking of any leakage and returning filling of soil for 80 mm bore CI/DI pipe line complete all as specified and directed. 147 All as per serial item number 120.00 here-in-before but for 100 mm bore CI/DIPipe. 148 All as per serial item number 120.00 here-in-before but for 150 mm bore CI/DIPipe. 149 All as per serial item number 120.00 here-in-before but for 200 mm bore CI/DIPipe. 150 Supply only CI/DI mechanical collar Joint suitable for 200 mm bore CI/DI pipe line complete all as specified and as directed. 151 All as per serial item number 124.00 here-in-before but for 150 mm bore CI/DIPipe. 152 All as per serial item number 124.00 here-in-before but for 100 mm bore CI/DIPipe. 153 All as per serial item number 124.00 here-in-before but for 80 mm bore CI/DIPipe. 154 Excavation in pot holes in soft/loose soil (or similar holes) each n exc 0.5 cum getting out, returning filling in and ramming earth to broken rubble mixed with earth around in layers not exceeding 25 cm, and removing surplus osil to a distance n exc 50m and making goood surface complete all as specified and directed 155 Material and labour for PCC 1:3:6, type C-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed 156 Dismantling wrought iron or mild steel work of any description not otherwiseprovided for all etc complete all as specified and directed. 157 Supply and fixin repairs of steel work in tubular works (round or square)/(angle incl special shaped washer etc complete using ERW or induction buttt welded tubes as in verticle posts, trusses, purlins (beam, tee, angle, channel, flat, sections) including distance pieces, cleats etc confirming to IS-1161-1979 grade St-240 complete including taking out old u/s steel work complete all as specified and directed. 158 Supply and fixof mild steel screw bolts (machine made) length of bolt exc 22.5 cm and n exc 30 cm alongwith hexagonal or square heads at one end and screwe the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5 cm long and diameter of neck 11 to 15mm complete including taking out old u/s steel screw, nut bolts etc complete all as specified and directed. 159 Dismantling Plain or corrugated steel sheeting, any gauge, thickness, includingNainital or similar pattern roof coverings all etc complete all as specified and directed. 160 Supply and fixin repairs of pre-painted galvalume aluminium zinc coating GI base corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fix with self tapping screws complete including taking down of old unserviceable GI sheet of any description and size complete all as specified and directed. 161 Material and labourfor preparing new steel surfaces of any description, over 10 cm width, girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide etc complete all as specified and directed. 162 Supply and fixin repairs MS ring flange 15 mm thickfor 200/150 mm bore to be welded to MS pipe/GI pipe including necessary welding work, new rubber gasket with necessary nuts and bolts etc, cutting out old unserviceable flange, complete all as specified and directed. 163 All as per serial item number 136.00 here-in-before but 100 / 80/ 50 mm bore. 164 Supply and fixing in repairs of 150mm bore HDPE Pipes class PN 10, ISI marked in any length with rubber ring joints, bends, tappers, MS nipple, MS flanged joints, laid in trenches or in floors/open and fittings etc complete all as specified and directed. 165 Material and labour for any welding work to arrest the leakages through MS flanges / bends /OHT & UG sump ladders/ headers /MS structures /any metallic pipe of any any size and length by providing welder all etc complete including cutting rusted parts complete all as specified and directed. Note :- (i) quoted rate shall be incluse of welding machine, welding rod etc required to carryout the work.(ii) Material such as GI/MS Pipe & MS shall be measured and paid under relevant items of schedule. 166 Material and labour in repairs of screw type sludge pump as per existing modelcomplete all asspecified and directed. 167 Supply, installation, testing and commissioning in repair of heavy duty chemical dosing system plunger type suitable to inject solution upto 25 LPH working pressure 10 Kg /Cm2 comprising dosing pump coupled with three phase electric motor of capacity 0.5 HP, 1440 RPM assembly with agitator in one motor, agitator with SS sweep blade duly FRP coated FRP tank 150 Ltrs, complete unit mounted on heavy duty MS fabricated frame duly anticorrosive paint complete with chemical grade PVC NRV, along with control panel for dosing pump suitable for Model SSAPS/CDSPT/25 made of powder coated MS fabricated box consisting of LED indicator, digital volt meter, amp meter, single phase preventor, high voltage low voltage protection including taking down old unserviceable dosing pump and necessary electrical interconnection all etc complete all as specified and directed.Make : Sri Satya Sai Aqua Pura / Declibac or its equivalent. 168 Labour only for taking out LT UG cables of 70/ 95 Sqmm by excavation and earth work in any type of soil, removing PCC covers of any size, staking serviceable cable for reuse complete all as specified and directed. Note :- Excavation, addl PCC covers and sand shall be measured and paid separately under relevant item of this Schedule. 169 Labour only for re-laying the serviceable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor, earthed, graded cross sectional area 70/95 sqmm 3.5 core in trenches/fixed to poles/wall, complete all as specified and directed. 170 Material and labour for unwashed sand cushioning to underground cable including punning down of sand in layer complete all as specified and directed. Note : Punned down thickness shall be measured for payment complete all as specified and directed. 171 Supply and lay unreinforced precast concrete cable cover Class LV, type 2 flat, size 300mm x 180mm x40mm in trenches as protection to UG cable complete all as specified and directed.
|