Tender For Provision Of Additional Room At Air Force School At Af Station Chabua Under Ge(Af) Chabua.; 1 B/R Portion:-Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft loose soil complete all as specified anddirected 2 Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting pointcomplete all as specified anddirected 3 Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m in depth for fdn, etc or for shafts, wells, cesspits, manholes, pierholes etc and n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in hard / dense soil completeall as specified anddirected 4 Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm completeall as specified anddirected 5 M&L for sand filling under floors or in foundations including watering and consolidation completeall as specified anddirected 6 M&L for broken stone hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified anddirected . 7 M&L for cement concrete type D2 1:4:8 (using 40mm graded stone aggregates)asin foundation, filling and mass concrete completeall as specified anddirected 8 M&L for Brickwork with subclass ‘B’ old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 completeall as specified anddirected 9 M&L for brick work with sub class "B" bricks, straight or curved on plan exc 6 m mean radius asin half brick thick wall built in CM 1:4 complete all as specified and as directed. 10 M&L for TMT bar 10mm dia and over cut to length bent to shape reqd incl cranking bending etc complete & binding with MS wire (annealed) not less than 0.9mm dia in reinforcement complete all as specified anddirected 11 All as per item No 10 (here in before) but 8 to 10mm dia as in stirrups completeall as specified anddirected 12 40mm thick Damp proof course in cement concrete 1:2:4, type B-I using 20mm grade stone aggregate to horizontal or vetical surface including necessary formwork complete all as specified anddirected 13 S&F steel work in tubular pole or pole including special shaped washer etc complete using ERW or incuction butt welded tubes conforming to I.S 1161-1998 grade St 240 complete all as specified anddirected. 14 S&F Roof trusses Fe 410-W(Gde-E- 250) quality-A (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel, or flat sec) incl gusset plat,distance pieces cleats etccomplete all as specified anddirected 15 Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified anddirected 16 S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of colour having tensile strength of 550 Mpa as iin roof covering/cladding to wall, fixed with self tapping screws including dismantling complete all as specified and as directed. . 17 S&F prepainted galvalume aluminium zinc coating GI basedplain steel sheet 0.50 mm thick ofcolour having tensile strength of 550 Mpa as inplain sheet as in ridges, gutters , facia bd etcl, fixed with self tapping screws or "J" /"L" hooks including dismantling complete all as specified and directed. 18 M&L for formwork to chajja, roof beams, lintels and soffits of roof projections etc and similar items including edges complete all as specified anddirected 19 M&L for formwork to rough finished flat surfaces of soffits of suspended slabs such as roof slabs, floor slabs and landing, stair cases and similar works complete all as specified anddirected 20 M& Lfor Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm widecomplete all as specified anddirected 21 M & L Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20mm graded stoneaggregate)in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likecomplete all as specified anddirected 22 M & L For RCC type B-1, 1:2:4 (20mm graded stone aggerates) as in beams, cantilevers, bressummers,lintels and the likecomplete all as specified anddirected 23 M&L for 15mm thick rendering in CM 1:6 over fair faces of brick / conc wall surfaces and finishing surfaces even and smooth without using extra cement complete. 24 All as per item No 23 (here in before ) but in CM 1:4 for other than fair faces of external wall surfaces and sponge finished completeall as specified anddirected. 25 All as per item No 23 (here in before ) but 10mm thick in CM 1:3 as in ceiling finished even and smooth using extra cement completeall as specified anddirected. 26 S & F for Power coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified 27 S & F Power coated aluminium window and ventilator shutters fixed, openable or sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, locking system etc. complete all as specified. 28 S & F galvanised mild steel wire cloth , 0.63 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with tinned tacks , or galvanised wire staplesstainless steel wire staplescomplete all as specified anddirected. 29 S&F sheet glass ordinary quality and glazing with oil putty in square nexc 0.5 sqm each pane 4mm thickcomplete all as specified anddirected 30 S & F 2nd Class H.W. plain solid straight chowkats & frames wrought, framed, rebated on the solid rounded or chamfered put together with glue, pinned at joints complete all as specified anddirected 31 M & L Flush shutter solidcore construction , with particleboard core 30 mm thick and deco rative face eneer with lipping/frame to matchon both sidecomplete all as specified anddirected 32 S&F for Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with m.s square tube supplying and fixing in opening as per specification and drawing. 33 M&L for Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded plaincolour PVC© channel PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock and bottom rail on either side as gap insert for top rail and bottom rail. Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded. Sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement supplying and fixing in the frame at site as per specification and drawing. 34 S&F 150 mm extruded aluminium alloy handles fabricated type. 35 S & F Aluminium anodised barrel tower bolt of extruded section 150mm long all as specified and directed 36 S&F butt hinges 100mm, medium weight complete 37 S & F 300mm long aluminium anodised sliding door bolt with hasp staple ( bolt type ) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed . 38 S & F MS 300 mm , ordinary rat rail tail , rod pattern springs , including roller and roller plate ( Helical door spring ) complete all as specified . 39 S&F power coated aluminium grill with mesh 75 mm and aluminium bar 6 mm XPM type including all accessories such as channels for fixing grill screws etc aluminium section 15 micron thick anodizing alongwith stainless steel wire cloth , complete all as specified . complete all as directed and specified complete 40 M & L preparation of new wooden surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specifiedand directed. 41 M&L for coloured non-skid tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match over and , including 15mm thick screed bed in cement mortar 1:6complete all specified. 42 All as per item No 40 (here in before) but in skirting over and including 10mm thick screed bed in cement mortar 1:4complete all specified. 43 M&L for glazed ceramic coloured tiles (light shade) ofsize 350x250x7mm/450x300x7mm thick for work on vertical surface such as skirting, dado, set & jointed neat in cement slurry and pointed in white or coloured cementto match over and including10 mm thick plaster in CM (1:4) complete all as specified and as directed. 44 M&L foe 20mm thickGranite (of any type) in window jambs work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. 45 M&L for kota stone slab flooring 20-25 mm thick laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 20 mm thick screed bed in CM (1:4) and cutting grooves in steps as ordered by engineer-in-charge complete all as specified and directed. 46 M&L for broken stone hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified anddirected . 47 M&L for 75mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregates as in floor subbase completeall as specified anddirected 48 M&L for 25 mm thick levelling course in cement concrete type B-1 1:2:4 using 20mm graded stone aggregatecomplete all as specified anddirected 49 M & L for 75mm thick cement concrete type C2 (1:3:6) using 40mm graded stone aggregate as in plinth protection and PCC paved area, finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed. 50 M & L for preparation of newly plastered surface of wall and applying two coats of OBD of approved tint and pattern over one coat of primer over a coat of 3mm thick wall care putty on wallcomplete all as specified and directed 51 M&L for preparation newly plastered surfaces of ceiling and applying two coats of OBD of approved tint and pattern over one coat of primer over a coat of 3mm thick wall care putty on wallcomplete all as specified and directed 52 M& L for preparation of newly plastered surfaces of wall and applying two coat of acrylic emulsion over a coat of alkali resistant primer of same makeover one coat of white wash complete all as specified and directed for external wallsNote : Arcylic emulsion of BERGER / ASIAN PAINT/DULUX etc with minimum warranty period of 05 years to be used with primer of the same make 53 M&L for cement concrete Type B-0 1:2:4 (12.5 mm graded stone aggregate) as in lintels upto1.5m clear span, window cills,steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs water troughs and the like including weathering,slightly rounded or chamfered angles and throating, as directed copping, rounded or chamfered on edges and the like complete all as specified and directed. 54 Supply and fix false ceiling work of galvanised iron powder coated frame work of size 28x24x0.9mm thick angle, snap grid size (605mm X 605mm) frame work with Hangers 6mm dia. GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expension hold fasteners 12.5mm dia. 40mm long and including necessary boldt, nuts and washers for flase ceiling with and including 4mm thick of size 600mm x 600mm HPSC (High pressure steam cured) prelamainated self embosed, textured disigner board E classic board as in ceiling tile fixed or laid/ inserted to framework complete all as specified and directed. 55 M&L for cutting holes in brick walls in built in cement mortar or cement lime mortar and stone walls built in lime mortar exc. Half brick but not exc one brick for inserting holdfasts and making good in dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed 56 S&F for bands, straps, supports or stays for rainwater, ventilating pipes, including bolts if required, hooks (stay) heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed 57 M & L for preparation of new or previously untreated surfaces of steel of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over coat of red oxide primer complete all as specified . 58 S&F for Vitreous china urinals, half stall type (back or corner wall type), complete incl providing & fixing plugs, bedding urinal against wall in CM 1:2, suring urinals to plugs with and incl 60mm long brass screws, pointing around urinals back in cement incl PVC connection 600mm long, Brass chromium plated waste fitting 32mm with waste pipe 32 mm dia, push button tap 15mm of cast copper alloy, screwed down for iron pipe and fixed complete all as specified and directed 59 S&F for 15mm dia bore two in one bib Cock CP fency type screwed down for iron pipe 15 mm bore 60 S&F for chromium plated hand shower (health fauset), telephonic type with 8mm dia, 1 meter long CP flexible tube with wall hook and jet of approved make, suitable for 15 mm bore iron pipes or for unions and fixed complete all as specified and directed. 61 S&F for vitreous china wash down water closet pan (pedestal pattern) coloured (including two Nosfixing bolts incl PVC seat cover but excludingflushing cistern and flush pipe) complete including fixing of P or S trap, complete all as specified and as directed. 62 S&F for 10 litres PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet ball valve, float and handle including brackets., flush pipe of polyethylene of low or high density or PVC 32mm dia for low level flushing cistern, PVC connection 600 mm longcomplete all as directed by Engr-in-Charge. 63 S&F for vitreous china wash hand basin white flat back size 550 x 400 mm excl taps waste chain, plug and porcelain stopper but includingbracket, waste pipe and 32mm dia brass waste coupling/fitting complete all as specified and as directed. 64 S&F 15mm dia SwanNeckpillar taps (ISI Marked) fancy type cast copper alloy with capastan heads, chromium plated screwed down high, long screwed shanks and fly nuts screwed for iron pipe. 65 S&F for grating square fitting of size 150 mm made in two parts for smell and mosquito proofing with min 25mm water seal ofPTMT (Min wt 85 gms) complete all as specified and directed. 66 S & FPVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and as directed. 67 S&F in repairrotational moulded polythene water storage tank of capacity 500 ltr (Cylindrical/vertical with closed top), double layer construction, ISI marked, hoisted & fixed in position including over flow 450mm, waste pipe 600mm long with fitting etc inclof 20mm dia complete all as specified and directed. 68 S&F for Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and directed 69 S&F in repair600 x 450 mm bevelled edge mirror of selected quality glass mounted on 6 mm thick AC bldg boardor commercial ply wood and fixed to wooden plugswith CP screws and cup washerscomplete all as specified and directed. 70 S&F for 15 mm dia bore bib taps cast copper alloy , chromium plated with long shank & cup, capston head, screwed for iron pipe, or for brass ferrule complete all as specified and as directed. 71 S&F in repair 15mm dia angle stop valvefancy chromium plated with long shank and cup concealed screwed down, high pressure, screwed both ends for iron or for unions and fixed. 72 S & F PVC (SWR) floor trap with grating 75 mm dia, plain with grating including jointing with solvent cement 73 S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floor 74 All as per Item No 73 (here in before) but 75mm dia 75 S&F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls. 76 S & F 110 mm PVC (SWR) junction single (single T) equal or unequal provided with access door. 77 S&F 110mm bore PVC (SWR) bendsprovided with access door any radius complete all as specified and as directed. 78 All as in item No.77but for 75 mm dia 79 Supply and fix 110 mm PVC(SWR) reducer 80 Supply and fix PVC (SWR) vent cowl 75mm Dia. 81 S&F for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement 82 M & L for Cement Concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete, filling etc all as specified and directed. 83 M & L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in bed to drain pipe 150 mm bore including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. 84 M & L for Precast Reinforced Cement Concrete 1:2:4 type B1 (using 20 mm graded stone agregate) asin cover slabs including necessary form work set in CM 1:4, complete all as specified and directed. 85 M & L for cutting into existing manholes for connecting new drains for 100mm internal dia pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150mm bore pipe line. complete all as specified and as directed. 86 S&F15 mm bore GI water tubemedium grade with all fittings and fixed to wall, floor and ceiling etc including concelaled/open completeall as specified and as directed. 87 S&F20 mm bore GI water tubemedium grade with all fittings and fixed to wall, floor and ceiling etc, complete including concealed/openall as specified and as directed. 88 S&F 1000 Ltr capacity Rotational moulded polythene water storage tanks(cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including adaptor and 20mm ball brass valves , high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed 89 S & F gate valve for 20 mm dia with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed. 90 S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework of water tanksand similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. 91 Excavating in post holes (or similar holes) each n exc 0.5 cu m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft / loose soil complete 92 E/M Portion:-M&L for point wiring complete with PVC insulated unsheathed FRLS-H multistranded copper conductor cable conforming to IS : 694 of size 1.5 Sqmm two single core drawn through in and including PVC concealed conduit pipe 20mm dia medium grade ISI Marked complete with one run of PVC insulated copper conductor cable 1.5 Sq mm single core green colour earth wire and connecting to earth dolly incl colour coding of cable shall be for phase, neutral and earth wire as specified in MES SSR Part I 2009 with provn of sunken galvanised not less than 1.12 mm thick MS sheet pressed terminal boxes concealed on wall, with 3 mm thick laminated sheet top cover ISI marked. Make: Hylum/Anchor for fixing of switches/socket/regulator with screws complete including making good of disturbed surfaces of wall/ceiling/floor in same specification as per existing all as specified and directed. (Note: A. Cutting chases, making good disturbed surface shall be included in quoted lump sum of schedule "A" Part-I and nothing extra shall be paid on this account one light point controlled by one switch. 93 All as per item No 92 (here-in-before) but One three pin 5 Amp socket outlet point on indep board controlled by one nos, one way switch on indep board 94 All as per item No 92 (here in before ) but point wiring with 4.0 sq mm single core FRLS cables and earth continuity wire with 4.0 Sq mm single core cable for one 3 pin 15 Amps socket out let point controlled by one nos, one way switch on indep bd.( 01 Nos new power point to be provided in each quarters). 95 S&F Modular switch piano flush type, single pole, one way, 6 Amp 230 volts all as specified and directed 96 S&FModular switch piano flush type, single pole, one way, 16 Amp 230 volts all as specified and directed 97 S&F Modular flush type socket utlet multipurpose 3 pin 6 Amp flush type 230 volts AC complete all as specified and directed 98 S&F Modular flush type socket utlet multipurpose 3 pin 15/16 Amp (with 3 pin 5/6 Amp outlet also) 230 volts AC complete all as specified and directed 99 S&F Modular lamp holder, insulated body with back plate suitable for batten fittings and complete all as specified and directed 100 S&F ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed 101 S/F modular cover plate with frame, 2 module 102 S/F modular cover plate with frame, 3 module 103 S/F modular cover plate with frame, 4 module 104 S/F modular cover plate with frame, 6 module 105 S/F modular metal flush box 1/2 module 106 S/F modular metal flush box 3 module 107 S/F modular metal flush box 4 module 108 S/F modular metal flush box 6 module 109 Supply and fix LED bulb of capacity10 W all as specified and directed 110 Supply & FixingLED light Fitting1x18W , regal batten for LED incl ultra bright glass LED tubelight with very high efficiency single/double side connection all as specified and directed 111 S&F Sheet metal enclosure distribution board SP&N,8 way, double door powder coated, protection class IP-42 suitable for mounting MCB DBs confirrming to IS-13032, IS-8632,BS5484 with min 200 Amp raiting copper bus bar complete all as specified and directed 112 S&F Sheet metal enclosure distribution board VTPN,4 way, double door powder coated, protection class IP-54, isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & /MCCB DBs confirrming to IS-13032, IS-8632,BS5484 with min 200 Amp raiting copper bus bar and grouting, fixing on wall with nut bolts wasshers properwithpcc works complete all as specified and directed 113 Supply and fixing MCBs SP 6 to 32Amps,240 volts, 10 KA rupturing capacity, IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) :-Note:Make of the MCB should be the same as that of DB 114 Supply and fixing MCBs SPN 32Amps to 63 Amps,240 volts, 10 KA rupturing capacity, IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) :-Note:Make of the MCB should be the same as that of DB 115 Supply and fixing MCCBs FP 63Amps,415 volts, 16 KA rupturing capacity, IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) :-Note:Make of the MCCB should be the same as that of DB 116 M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6.3 mm thick buried directly in ground vertically (in earth pit not less than 2.25 metre deep below ground level) with the top edge of earth plate at a depth not less than 1.5 metre below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI earth wire 4 mm dia bolted (with GI nuts, bolts & check nuts) and rivettedto earth (Plate) electrode at one end and connected to main switch board / DB at the other, earth wire protected by and incl GI pipe 15 mm dia (medium grade) from top of electrode to main switch board and also incl watering pipe GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B0using 12 mmgraded crushed stone aggregate, RCC cover etc all as shown on electrical plate No 3 of SSR - 2009 Part I. 117 Supply and draw submain wiring with two single core 6 sqmm FR PVC insulated copper cable 1100 volts grade multistrand, unseathed conductor drawn into FR PVC casing and caping and all necessary fittings including 6 sqmm multi strand FR PVC insulated copper wire for earth continuty conductor connected to common earth dollycompleteall as specified and directed. 118 Supply & fixing of Bldg security light fitting LED 30/40 W, pressure die cast housingepoxy powder coating IP -65, connected with and including 0.5 sqmm flexible copper multistranded conductor cable including security light bracket made to shape out of GI pipe 40 mm bore light grade, 1.5 mtr length and fixed with MS Calmps of size 40x5 mm- 02 nos ,nuts, bolts and washers on wall. all as specified and directed. 119 M&L for onlyPVC concealed conduit pipe 20 mm dia medium grade ISI Marked complete all as specified and directed.( For AFNET Wire) 120 Supply, laying, and testing galvanised iron pipes of50 mm bore medium grade with ISI Marked with all necessary fittings ( such as bends, elbows, tees, short pieces of medium grade pipe, connectors, back-nuts, caps, plugs and unions etc.) layingin trenches/ floors/ ducts and also cutting pipes, screwing,and for making forged bends on piping as required, complete all as specified and as directed by Engr-in-Charge. 121 Supply and lay pipe galvanized, “Medium class”, including fittings 25 mm dia (1”) dia 122 M&L for cutting of existing CI/GI pipe line for insertion of tee and tail piece and jointing material copmlete all as specified 123 Supply and fix Valve, stop, screwed, 25 mm (1”) dia pipe. 124 Supply and fix Valve, stop, screwed, 50 mm (1”) dia pipe. 125 Valve pit masonary of size 600x600x600 mm for valve constructed complete with MS sheet cover and locking arrangement etc. 126 Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed. 127 Material and labourfor sandcushioning to under ground Cable ( 15 cm thick before laing and 8 cm thick after laying the cable )complete all as specified and directed.Note :- Punned down thickness shall be considered for messurement 18 cm complete all as specified and directed by Engr-in- charge. 128 Supply and layingBricks comman burnt clay building bricks Old size with sub class B Designation 75. complete all as specified & directed. 129 S&FGI tube light grade 50mm dia with all fitting and laid in floors, under road, pavement or hard standing for protection of earthing strip including takingout GI pipe complete all as specified and directed.
|