(Id124793) Multiparametric Monitor, Application: Adult, Pediatric And Neonatal Use; Lcd/Led Screen 12 To 15 Inches With Touch Screen And Minimum Resolution Of 800X600; Modular Or Preconfigured, With Monitoring Of: Ecg, Spo2, Non-Invasive Pressure (Nip) And Temp; Minimum Simultaneous Visualization Of 4 (Four) Curves, With Their Numerical Values; Audible And Visual Alarm System, With User-Programmable Maximum And Minimum Limits For All Monitored Parameters; Have An Alarm Suspension Alert Indicator; Automatic Screen Reconfiguration; Patient Data Record; Possibility Of Connection With A Monitoring Center; Software In Portuguese; Ecg: Monitoring In 07 Leads (I, Ii, Iii, Avf, Avr, Avl, V); Heart Rate (Hr): 15 To 250Bpm; St Segment Analysis In All Derivations; Analysis Of Fatal Arrhythmias In Two Simultaneous Channels, At Minimum (Optional); Analysis Of Arrhythmias (Asystole, Ventricular Fibrillation/Ventricular Tachycardia, Bigeminism, Among Others); Automatic Pacemaker Detection; Pulse Oximetry (Spo2): Low Perfusion Technology; Present Plethysmographic Curve; Spo2 Saturation Range: 1 To 100%; Pulse Frequency Range (Fp): 40 To 250Bpm; Non-Invasive Pressure (Nibp): Systolic Blood Pressure (Pas), Diastolic Blood Pressure (Pa) And Mean Blood Pressure (Pam); Measurement Modes: Manual, Automatic And Stat; Pressure Measurement Range: 30 To 270Mmhg; Temperature: 02 (Two) Monitoring Channels; Temperature Measurement Using A Sensor Adhered To The Patients Skin, Or Through Cavities, Such As The Esophagus Or Rectum; Temperature Range That Meets The Range: 25 To 45°C; Trends: Minimum Storage Of 24H Non-Volatile; Mains Or Battery Indicator; Rechargeable Battery With Minimum Autonomy Of 90 Min; Self-Test When Starting; Automatic Ac Power 100240V; Accessories: 03 Ecg Cables 05 Ways; 100 Sets Of Disposable Ecg Electrodes: Adult, Pediatric And Neonatal (300 Total); 05 Reusable Adult Spo2 Sensors; 05 Senso, (Id124794) Defibrillator/Cardioverter, Application: Intended For Adult, Pediatric And Neonatal Patients; Biphasic, Rectilinear Or Truncated Exponential Cardioverter/Defibrillator; Fully Microprocessed, Interact With Cardiac Monitoring, Oxygen Saturation Measurement (Spo2) And Transcutaneous Pacemaker Integrated In A Compact Unit That Operates Independently Of The Availability Of Electricity Through A Rechargeable Battery; Consisting Of: Lcd/Led Display Minimum 6.5 Inch Or Compatible Size For Presenting Three Ecg Channels Simultaneously; Touch Screen And/Or Membrane Keyboard; Programmable Audible And Visual Alarms; It Has Audiovisual Alarms During Continuous Monitoring Of Spo2 And Ecg With Cable (3 And 5 Ways), Ventricular Fibrillation And Maximum And Minimum Heart Rate; Have A Biphasic Waveform With Automatic Adjustment Depending On The Impedance Of The Adult Or Pediatric Patient; Minimum Degree Of Protection Ip22; Detection And On-Screen Visualization Through Markers Of Most Implantable Pacemaker Pulses; Capture Of The Ecg Signal Through The External Panels Or Through The Patient Cable; Thermal Printer, Which Prints Ecg Curve, Heart Rate, O2 Saturation, Date And Time; It Has An Ecg Circuit Input Isolated From The Electrical Network (Floating) And A Defibrillation Protection Circuit; Defibrillation With System 1, 2, 3; Electrically Insulated Cabinet; Scale For Internal Or External Defibrillation, Adult Or Child, Select
|