|
Tender For Provision Of Oh Tanks Ug Sumps And External Services For Map Ph-Ii Under Ge S Pune And Ge N Pune.; 1 SCH "A" PART-I TO VII:Note: These schedules are pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only 2 Total amount of Sch ‘A’ Part I (Building & Structure) 3 Total amount of Sch ‘A’ Part II (Internal Water supply) 4 Total amount of Sch ‘A’ Part III (Internal Electric Supply) 5 Total amount of Sch "A" Part-IV (Sewage Disposal) 6 Total amount of Sch "A" Part-V (External Water Supply) 7 Total amount of Sch "A" Part-VI (External Electric Supply) 8 Total amount of Sch "A" Part-VII ( LIGHTNING PROTECTION ) 9 Total amount of Sch "A" Part-VIII (Excavation and Earthwork) 10 SCHEDULE "A" PART-IX (MISC B/R ANDE/M WORKS)Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only. 11 MISC ITEMS E/M WORKS OF INTERNAL & EXTERNALELECTRICAL SUPPLY 12 S&FLEDstreet light luminaire 25 W with pressure die castaluminium housing LED street light luminaries with IP66 with 25 W high power LED, maintenance free system and connecting up with cable, including 1.5 m long GI bracket of required dia, bent to shape, clamp and nut bolts of suitabler size complete all as specified and all as directed. 13 S&F solar powered aviation obstructionlamp complete sysytem make: Altos model AOL-Q-3 SP or equivalent model in philips / Crompton Greaves / bajaj consisting of : (a)LED based avitation obstruction lamp fitting (b) solar panel (c)Battery unit (d) Mounting structure for all above with inter connecting wiring complete all as specified and ditected. 14 Testing and commissioningtransformer copper wound step down, out door type, complete with all standard fitting of capacity 100 KVA, AC 3 phase, 3 wire primary, 4 wire secondary, 50 C/S type HT-22 KV, 3 PH, LT-433 Vand making compete connection of HT and LT Sidewith glands, lugs complete all as specified and directed.(Note- Transformer already installed /mounted on platform at site , before commisioning contractor will carried out Acidity Test,Sludge test, Insulation resistance Test,Break down voltage test of Oil.If test result not meet as per IS standard,contractor will carried out servicing of transformer at site In case of Sphare is out of order andreplacement requiredSphare part of transformer paid sapareatluy under relevent Item. 15 All as per item No- 11.003above but capacity22 KV 200 KVA. 16 Installation, testing and commissioningtransformer copper wound step down, out door type, complete with all standard fitting of capacity 300 KVA, AC 3 phase, 3 wire primary, 4 wire secondary, 50 C/S type HT-22 KV,LT-433 V and making connection on HT & LT side with gland and lugs , The transformer will mount on platform as per manufacturer instruction 0r Typical drawing or of size of size 2.00 M x 2.00 M x 3.50 M deep (1.00 m below GL) withPCC (1:3:6) type C2 and15 cm thick RCC (1:2:4) type B1 for top, reinforced with 10 mm dia TMT bars @ 150 mm C/C complete including excavation & earthwork in any type of strata viz soft/loose/hard/dense/Rock, frame work all as specified and directed(Note- Transformer shall be issued under Sch "B" free for fixing , before commisioning contractor will carried out Acidity Test,Sludge test, Insulation resistance Test,Break down voltage test of Oil.If test result not meet as per IS standard,contractor will carried out servicing of transformer at site In case of Sphare is out of order andreplacement requiredSphare part of transformer paid sapareatluy under relevent Item.The rate quoted by the contractor shall deemed to be included the cost offoundationa and transportation of transformer from MES yard to work site.No extra payment shall be made on this account.) 17 All as per item No- 11.005above but capacity 11 KV100 KVA. 18 All as per item No- 11.005 above but capacity 22 KV 400 KVA. 19 Servicing of existing LT electrical distribution/control panel of any size and capacity including cleaning of dust and debris, tightening of all connections, checking of contactors/relays, testing of insulation resistance, repair/replacement of defective control wiring (upto 1.5 sqmm copper) and faulty indicators (LED type), Testing and replacement of defective control MCBs upto 63A andensuring full operational status. Complete in all respects as per standard practice and directed by engineer-in-charge 20 Supply, jointing and testing outdoor cable end termination joint (heat shrinkable) suitable for 3 core 185 sqmm 22 KV XLPE cable suitable for earth system complete all as specified and directed. 21 Supply & fix heat shrinkable straight through joint 22 KV XLPE cable suitable for earth system of size 185 sqmm 3 core complete all as specified and directed. 22 M&L Earthing with 600x600x6mm galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge or the plate at a depth of not less than 1.5 m below ground level, connected to and including galvanised eath strip 32 mm x 6 mm by means of bolts,nuts and check nuts and washers of galvanised steel. Gl pipe 40 mm dia light grade pipe for protection of G.l. earth strip both to be provided to the extent of 7.5 meters as earthing lead and connecting to the eqpt/machinery etc. incl charcoal dust and common salt packed all around the earth plate in alternate layer in the earth pit all as per elctrical plate No. 3 of SSR Part 1·2009 including PCC chamber made up of PCC 1:3 :6 type C1 & RCC Chamer cover of size 540x540x100 mm made with 1:2:4 Type B1 using 6 mm round MS bar & 8 mm MS bar for handle , 20 mm dia medium grade G.I. Watering pipe from top edge of the earth plate upto M.S funnel with wire mesh provided inside the concrete earth pit for watering arrangement including excavation and earth work in any type of soil and testing complete all as specified and directed. 23 Installation testing and commissioning of OUTDOOR TYPE ENCLOSURE, Double door, with angle iron pedastal frame & including steel structure required for installation on cable trench housing cubicle Type, free standing Panel CPRI approved working on 440 V 3 phase 50 Hz, AC supply with aluminium bus bar suitable for 800 Amps fully compartmentalized, dust-proof and vermin proof, 3.15 mm thick CRCA sheet steel enclosure painted asper the 7-tank process & suitable for IP-56 protection, as per section and having the following details and as shown in single line diagrams GE/1668/901:(a) Volt meter 0 – 500 Volt with selector switch – 01 (b) Ammeter 0.1000 Amps with CTs and selector switch – 01. (c) Indication Lamp assembly – RYB LED – 01 set.Incomer : 630 A 4 pole, ACB-02 Nos. Bus coupler : 630 A 4 Pole, ACB -01 No. Outgoing feeders :3 Pole, 315 A MCCB, 50 KA -05 Nos, 4 Pole, 250 A MCCB,35 KA-03, 3 Pole, 200 A MCCB, 35 KA -02Nos, 4 Pole, 100 A MCCB, 25 KA-01 Nos. Panel fabrication & Bus bar for above feeders. (Note- LT Panel with components as above shall be issued under Sch "B" free for fixing ) 24 Installation, testing & commissioning of OUTDOOR TYPE ENCLOSURE, Double door, with angle iron pedastal frame & including steel structure required for installationon cable trench housing cubicle type, free standing, panel CPRI approved 3 phase, 50 Hz, AC supply with aluminium bus bars, fully compartmentalized, dust-proof and vermin proof, 3.15 mm thick CRCA sheet steel enclosure painted as per the 7-tank process & suitable for IP-56 protection, as per specifications and having the following details and as shown in single line diagrams GE/1968/901 : (Note- LT Panel with components as above shall be issued under Sch "B" free for fixing )Incomer:160A, 4 pole 25 KA, MCCB with S/C adjustable, O/L & E/F thermal magnetic releases - 01 eachOutgoing Feeders:160A, TP, 25 KA, 415 VoltMCCB withS/C & adj. O/L& E/F thermal magnetic releases - 05 Nos25 KVAR APFC Compartment80A, TPN, 25KA - 1 No, MCCB with fixed neutral and S/C & adj. O/L thermal magnetic release 01 Each8 Stage APFC Relay16A, TPN, 25KA, MCCB with fixed neutral and S/C & adj. O/L thermal magnetic releases (for 5 KVAR Capacitor) 01 Each32A, TP, 25KA, MCCB with fixed neutral and S/C & adj. O/L thermal magnetic releases (for 10 KVAR Capacitor) - 02 NosCapacitor MD - XL 25 Installation testing and commissioning diesel engine/driven generating set of capacity 30 KVA (24 KW) 415 volts 0.8 power tractor at NTP, mounted on base platform with flexible coupling, 1500 RPM alongwith sound proof enclosure (Acoustic Enclosure) designed for reducing the sound level to 7+5 to B(A) (average) IS8528 part - 10 as per approved CPCB norms and as per GSR 371 (E) dated 17.05.2002 with silencer pipe and silencer muffler covered with asbestos rope 25 mm thick independently supported from engine to outside of power house upto 1 mtr, cold start kit, battery start with suitable size of standard dabbles for connecting from DG Set to panel board DG set shall be capable with and including the following:(A) PRIME MOVER: Diesel engine of suitable capacity water cooled (Radiator mounted) closed circuit as per BS-649 or IS-1002 direct injection type with turbo charger. Make: Cummins India Ltd/Kirloskar. The diesel engine shall be capable of running 24 hour continuously with 10% over loading for one hour in every 12 house as per BS 5514/- BS 649/- Engine shall be equipped with all standard fittings as per manufactures recommendations mounted on common base plate/form through flexible coupling with following accessories :(Note- DG Setwith components as above shall be issued under Sch "B" free for fixing ) (a) RPM cum hour meter(b) Battery Charging Ammeter(c) Ignition key and starting with push buttons(d) Lubricating oil pressure gauge(e) Electronic governor controlling 26 (f) Toggles switch for idle running(g) Oil Tem gauge (h) Water temp gauge(j) Safety control (Trip)(i) High water temperature(ii) Low Lubricant oil pressure(iii) Over speed(k) 24 hours starting equipment comprising with the following:(i) 1 No. 12 volt 180 AH batteries, Make: Exide type 25xnN21 or equivalent as recommended by manufacturer.(ii) Battery charging alternator with built in regulator.(iii) Starter motor assy of suitable capacity.(iv) Battery leads (copper stranded cable) of suitable size with brass thimbles and erminal Make of engine : Kirloskar/Cummings(B) ALTERNATOR: Alternator of capacity 30 KVA/24 KW at NTP, 415 volts, 50 C/S, 1500 RPM, 0.8 power factor, self excited, self regulated, screen protected with self excited field brush rotating fixed designed to be coupled with above engine through flexible coupling. the alternator shall be conformed to 4722 of BS-2613 MAKE: Kirloskar C) CONTROL PANEL : Alternator control panel floor mounted, cubical type with internal wiring with copper conductor for 30 KVA, 415 volts, 3 Phase 4 wire, 50 cycle alternator fabricated out of MS Sheet painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer equipped with the following accessories: 27 (i) AC voltmeter with selector switch 0-500V 01 No.(ii) Ammeter with CT and selector switch of suitable range 01 No(iii) Frequency meter - 01 No.(iv) KW and KWH meter - 01 No.(v) Power factor meter - 01 No(vi) MCCB (for incoming) as recommended by manufacturer - 01 No(vii) Set of copper bus bar of suitable size 01 No.(viii) Set of indicating lamps for 3 phase (RYB) 01 No(ix) Oil Pressure gauge 01 No(D) OTHER FITTINGS: (i) Battery Charger : Battery charger having electric circuit consisting of rectifiers, capacitors and resistance etc. The battery charger should be able to charge 12 volts 180 AH battery 2 Nos at a time(ii) Fuel tank of suitable capacity as per manufacturer recommendation mounted on steel frame at suitable height with all connecting pipes and fittings upto fuel pump and over flow pipe from engine to tank including level indicating gauge duly marked and drain valve and air vent plug etc. (E) Maintenance Spares:(i) Fuel filter element - 02 Nos(ii) Oil filter elements - 03 Nos(iii) Fan Belt - 01 Set(iv) Hose pipe - 01 Set(v) Tappet over gasket - 01 No(F) DG set shall be supplied along with acoustic original enclosure of the manufacture’s suitable for 30 KVA DG Set per CPCB Norms 28 Installation testing and Commissioning of INDOOR TYPE ENCLOSURE with angle iron pedestal frame & including steel structure required for installation on cable trench housing cubicle type, free standing, panel CPRI Approved working on 440 V, 3 Phase50 Hz, AC supply with aluminium bus bars, fully compartmentalized, dust-proof and vermin proof, 2 mm thick CRCA sheet steel enclosure painted as per the 7-tank process & suitable for IP-56 protection, as per section and having the following details and as shown in single line diagrams Ge/1968/905 (Note- LT Panel with components as above shall be issued under Sch "B" free for fixing )INCOMERFP pole MCCB 250 Amps 35 KA – 02 NosOut Going feeders:TPN pole 16A MCCB, 25 KA – 02 NosTPN pole 20A MCCB, 25 KA – 02 NosTPN pole 63A MCCB, 25 KA – 02 NosTPN pole 100A MCCB, 25 KA – 02 NosTPN pole 125A MCCB, 30 KA – 02 Nos3 KVAR capacitor duty contractor – 02 Nos5 KVAR capacitor duty contractor -02 Nos20 KVAR capacitor duty contractor -02 Nos30 KVAR capacitor duty contractor -02 Nos40 KVAR capacitor duty contractor -02 Nos8 stage APFC relay – 02Nos 29 Installation testing and commissioning diesel engine/driven generating set of capacity 160 KVA (128 KW) 415 volts 0.8 power tractor at NTP, mounted on base platform with flexible coupling, 1500 RPM alongwith sound proof enclosure (Acoustic Enclosure) designed for reducing the sound level to 7+5 to B(A) (average) IS8528 part - 10 as per approved CPCB norms and as per GSR 371 (E) dated 17.05.2002 with silencer pipe and silencer muffler covered with asbestos rope 25 mm thick independently supported from engine to outside of power house upto 1 mtr, cold start kit, battery start with suitable size of standard dabbles for connecting from DG Set to panel board DG set shall be capable with and including the following:(A) PRIME MOVER: Diesel engine of suitable capacity water cooled (Radiator mounted) closed circuit as per BS-649 or IS-1002 direct injection type with turbo charger. Make: Cummins India Ltd/Kirloskar. The diesel engine shall be capable of running 24 hour continuously with 10% over loading for one hour in every 12 house as per BS 5514/- BS 649/- Engine shall be equipped with all standard fittings as per manufactures recommendations mounted on common base plate/form through flexible coupling with following accessories : (Note- DG Set with components as above shall be issued under Sch "B" free for fixing ) complete all as specified and directed.(a) RPM cum hour meter(b) Battery Charging Ammeter(c) Ignition key and starting with push buttons(d) Lubricating oil pressure gauge(e) Electronic governor controlling(f) Toggles switch for idle running 30 (g) Oil Tem gauge (h) Water temp gauge(j) Safety control (Trip)(i) High water temperature(ii) Low Lubricant oil pressure(iii) Over speed(k) 24 hours starting equipment comprising with the following:(i) 1 No. 12 volt 180 AH batteries, Make: Exide type 25xnN21 or equivalent as recommended by manufacturer.(ii) Battery charging alternator with built in regulator.(iii) Starter motor assy of suitable capacity.(iv) Battery leads (copper stranded cable) of suitable size with brass thimbles and erminal Make of engine : Kirloskar/Cummings(B) ALTERNATOR: Alternator of capacity 160 KVA/128 KW at NTP, 415 volts, 50 C/S, 1500 RPM, 0.8 power factor, self excited, self regulated, screen protected with self excited field brush rotating fixed designed to be coupled with above engine through flexible coupling. the alternator shall be conformed to 4722 of BS-2613 C) CONTROL PANEL : Alternator control panel floor mounted, cubical type with internal wiring with copper conductor for 160 KVA, 415 volts, 3 Phase 4 wire, 50 cycle alternator fabricated out of MS Sheet painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer equipped with the following accessories: 31 (i) AC voltmeter with selector switch 0-500V 01 No.(ii) Ammeter with CT and selector switch of suitable range 01 No(iii) Frequency meter - 01 No.(iv) KW and KWH meter - 01 No.(v) Power factor meter - 01 No(vi) MCCB (for incoming) as recommended by manufacturer - 01 No(vii) Set of copper bus bar of suitable size 01 No.(viii) Set of indicating lamps for 3 phase (RYB) 01 No(ix) Oil Pressure gauge 01 No(D) OTHER FITTINGS:(i) Battery Charger : Battery charger having electric circuit consisting of rectifiers, capacitors and resistance etc. The battery charger should be able to charge 12 volts 180 AH battery 2 Nos at a time(ii) Fuel tank of suitable capacity as per manufacturer recommendation mounted on steel frame at suitable height with all connecting pipes and fittings upto fuel pump and over flow pipe from engine to tank including level indicating gauge duly marked and drain valve and air vent plug etc.(E) Maintenance Spares:(i) Fuel filter element - 02 Nos(ii) Oil filter elements - 03 Nos(iii) Fan Belt - 01 Set(iv) Hose pipe - 01 Set(v) Tappet over gasket - 01 No(F) DG set shall be supplied along with acoustic original enclosure of the manufacture’s suitable for 160 KVA DG Set per CPCB Norms 32 Installationtesting & commissioning of indoor cubic type, free standing floor mounted including of steel structure required for installation on cable trench with base frame, AMF panel CPRI approved on 440 V 3 phase 50 HZ, AC supply. It shall be extendible at both ends, with aluminium bus bars 200 amps capacity fully compartmentalized dust-proof and vermin proof, 2 mm thick CRCA sheet steel enclosure painted as per the 7-tank procress & suitable for IP-52 protection, as per section and having the following details and as shown in single line diagrams GE/1968/094 , complete all as specified and directed.( Note - AMF panel with components shall be issued under Sch B free for fixing ).Incomer100A 4 pole, 25 KA motorized MCCB – 01 NoOutgoingTPN 63 A MCCB, 25 KA – 02 NoTPN 32 A MCCB, 25 KA, 32 A MCCB, 25 KA – 2 NoPanel Fabrication & Busbar for above feeder 33 Installationtesting & commissioningof cubic type, free standing floor mounted weather proof type, pedestal mounted feeder pillar working on 440 V 3 phase 50 Hz, AC supply., It shall be with alum.bus bar 300 amps capacity weather proof dust proof with canopy on top 3.15 mm thick CRCA sheet steel enclosure, painted as per the 7-tank process and painted for outdoor weather proof IP-55 protection installation, as per specification and having the following details and as shown in single line diagrams GE/1968/903 complete all as specified and directed.(Note- LT Panel with components as above shall be issued under Sch "B" free for fixing )IncomerFP 315 A MCCB,50 KA- 01 NoOutgoingTPN 63A MCCB, 25 KA – 08 NosPanel Fabrication & Busbar for above feeder 34 Installationtesting & commissioningof cubic type, free standing floor mounted weather proof type, pedestal mounted feeder pillar working on 440 V 3 phase 50 Hz, AC supply., It shall be with alum.bus bar 300 amps capacity weather proof dust proof with canopy on top 3.15 mm thick CRCA sheet steel enclosure, painted as per the 7-tank process and painted for outdoor weather proof IP-55 protection installation, as per specification and having the following details and as shown in single line diagrams GE/1968/903 complete all as specified and directed.(Note- LT Panel with components as above shall be issued under Sch "B" free for fixing )IncomerFP 250 A MCCB,35 KA- 01 NoOutgoingTPN 63A MCCB, 35 KA – 08 NosPanel Fabrication & Busbar for above feeder 35 Supply, Install, testing, and commissioning of outdoor type, enclosure double door with angle iron pedestal frame & including steel structure required for installation on cable trenches, housing cubical type free standing,panel working on 440 volts, 3 phase 50 hz, AC supply with aluminium bus bar,full compartmentalised dust proof and vermin proof 3.15 thcik CRCA sheets steel enclosure, painted as per the 7-tank process & suitable as per IP-56 protection as per specification and having the following details and as shown in single line diagrams GE/1968/901 (Panel for 3 Alexander Road) complete all as specified and directed.a)MCCB 160 amps 4 pole, 25 KAbreaking capacity with short circuit adjustable overload& earth fault thermal magnetic release-8 Nos, CTs, ammeter with selector switch, voltmeterwith selector switch(Incomer)-01 Nos Bus bars: 250 A TPN aluminium Busbars suitable for 25kA for 1 Sec Outgoing Feeders :a) MCB TP 40 Amps 25 KA breaking capacity with short circuit adj overload and B/F thermal magnetic releaseb) Suitable enclose IE panel fabrication and bus bars for above MCB feeders. c) Angle iron base frame as reqd size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legsand made out of ISA 5050, 50 x 50 x 6 mm thick angle iron duly painted - 01 No.d) M & L for necessary grouting as reqd PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete - 01 job 36 Supply, installation, testing and commissioning of readymade 08 way TPN DB metal doorwith 200A rated busbar with following (CAT Part NoDBTPN008DDS of L& T or equivalent in Siemens/Legrand/C&S)Incomer: (a) MCB 4 Pole 60 Amps, 415 Volts breaking capacity 10kA "02 Nos" (BB30630C of L &T)Outgoing feeders:(a) MCB TP 25 Amps, 415 Volts breaking capacity 10kA "04 Nos" (BB30250C of L &T)(b)MCB SP 10 Amps, 230 Volts breaking capacity 10KA "04 Nos" (BB10100C of L &T) 37 Supply, installation, testing and commissioning of outdoor line up of 11 KV RMU type compact panels, consisting of following :-11 KV 630 Amps 20KA for 3 sec. air/gas insulated RMU panel with 1 No incommingmanullay operated VCB" and 02 Nos outgoing load break switches,CT"s for protection as per detils given in specification complete in all respect inverse time over, current, short circuit & earth fault with instantaneous elements relay.Indication : ON, Off, Trip, R.Y.B. with facility for transformer buchholz relay trip with terminals for 230V AC supply aluminium Busbars 630 Amps, 11KV, TP busbars for 20 KA for 1 sec with PCC foundation all as per required & as per manufacturer instructions. complete all as specified and directed. 38 Supply, installation, testing and commissioning of 11KV 50/5 Amps ratio oil immersed vacume impragnated single phase current transformer with VA burden of 15 for class 0.5 class SP 10 with 25 KA short circuit rating for 1 second complete with all structure base and mounting arrangement as indicated and also as per specification and technical particulars. 39 Supply,Installation , testing and commissioning of outdoor line-up of 22 KV RMU type compact panels, consisting of : 22 KV 630A, 20KA for3 sec Air/Gas insulated RMU panel with 1 No Incomer & 2 Nos outgoing: 22 kV, 16 kA for 1 second, 630A HT VCB with 3 nos. resin cast 22000V/ sqrt. 3/ 110V/ sqrt. 3 withdraw-able PTs, HT and LT fuses ffor PTs, In comer 3 nos 50/1A & in outgoing 9 Nos. 20/1A CT"s-core-1: class 0.5 CTs for metering, Core 2 : class 5 P10 for protection, inverse time over current, short circuit & each fault with intantenous elements relay, master trip, R.Y.B spring charge, trip circuit healthy. ON-OFF Push buttons illumination lamp, hooter, industrial socket with switch, space heater with thermostat, control MCB & control terminals etc complete all as specified and directed. 40 Laying only in trenches or fixing on wall or pole LT XLPE UG cable insulated screened PVC beded GI steel strip or wire armoured electric power cable (Heavy duty) with standard aluminium conductor 1100 volt grade of the follwing size including provision of necessyar lugs and glands as under : (Note- LT under ground cablementioned below at sl No (a) to (i) shall be issued under Sch "B"for laying/fixing ) 41 a) 300 sqmm 3.5 core 42 b) 240 Sqmm 3.5 core 43 c) 185 sqmm 3.5 core 44 d) 150 Sqmm 3.5 core 45 e) 120 Sqmm 3.5 Core 46 f) 50 Sqmm 3.5 Core 47 g) 35 Sqmm 3.5 core 48 h) 25 Sqmm 4 core 49 i)16 Sqmm 4 core 50 Supply and fixing and installation of fire extinguisher CO2 Map cap of 4.5 Kg as per IS 2878 Complete all as specified andas directed. 51 MS fire bucket 13 Ltr Cap of fire approved quality painted red filled with sand Complete all as specified andas directed. 52 Supply only hand gloves for safety,suitable for 22 KV grade. Complete all as specified andas directed. 53 Supply only hand gloves for safety,suitable for 11 KV grade. Complete all as specified andas directed. 54 MS padestal stand duly painted for suspending fire buckets 55 M&Lfor shock treatment chart in different languages (english, Hindi, Marathi) 56 Supply and placing of first aid box as per specification 57 Cable route marker made of galvanised iron supporting with GI angle for HT/LT cable root marking 58 M&L for Road cuttingby core cutting machine not less than 0.6 mtr wide and .45 mtr depthfor laying RCC and GI Pipe for the the HT/LT cable and making good surface with PCC 1:4:8 type D-2 using 40 mm graded stone aggergatecomplete all as specified and directed. 59 Supply and erect steel tubular poles swaged welded poles complete for two pole structure with MS base plate, MS pole cap, bolts nuts, and screws as per IS 2723 ( part II ) 1980 made out MS tyubing duly painted with metal primer and two coats of aluminium paint over exposed surface and Making 4 Nos of strips of 30 cm wide in alternate black and yellow colourup to 1.5 mtr hight, Writing pole number and voltage level encompassed by circle of suitable diausing two coats of synthetic enamel paint over a coat of red oxide zinc chrome primerbottomand one coat of red oxide and two coats of bituminous paint for embedded portion as specified type 410 SP - 31 of 9 mtrs long complete all as specified and as directed. ( Note- Excavation / earth work , PCC will be measured and paid separately ) 60 S&F FRP box,MCB SP 6 Amp-01 No and clamps made out of FI 32x6mm and GI nut bolts. Complete all as specified andas directed. make-syntex Model GSJB-3020 with 4 connectors or eqvt 61 S&Ftimer switch box fabricatedout of 16 SWG CRCA sheet with mounting arrangement duly powder coated consisting of the following :-a) Timmer astronomical-1, b) Power contactor 63 Amps make- -01 Noc) connector 100 Amps 230 Volts - 03 Nosd) MCB TPN 63 Amps 415 V - 01 Noe) Control fuse 2 Amps -01 NoComplete all as specified andas directed. 62 S&F pin type polymer/porcelain, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut 150 mm height, 150 mm dia for suitable for 22 KV working pressure. Complete all as specified andas directed. 63 S&F Disc type porcelain, vitreous, white, brown or green i nsulator includingone galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut 145 mm height, 255 mm dia ball and socket type Two-in-assembly for tension with tension clamps for conductor suitable for 22 KV working pressure. Complete all as specified andas directed. 64 Supply and lay rubber mat 2 mtr x 1 mtr,10mm thick 11 KV grade AC elect supply. Complete all as specified andas directed. 65 Supply and lay rubber mat 2mtr x 1 mtr,30mm thick 22 KV grade AC elect supply. Complete all as specified andas directed. 66 Supply and lay rubber mat 2mtr x 1 mtr, 19mm thick 11 KV grade AC elect supply. Complete all as specified andas directed. 67 Supply, jointing and testing Outdoor type cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm. Complete all as specified andas directed. 68 Supply, jointing and testing Outdoor type cable jointing kit for 22 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm. Complete all as specified andas directed. 69 Supply, jointing and testing indoor typeCable jointing kit for 11 KV (Earthed)grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size ofsize 150 sqmm 70 M & L for discharge rod PVC coated suitable for 22KV. With PVC insulated copper conductor cable of size 7/20 of 10mtr long with crocodile clips at the end. Complete all as specified andas directed. 71 M & L for discharge rod PVC coated suitable for 11KV. With PVC insulated copper conductor cable of size 7/20 of 10mtr long with crocodile clips at the end. Complete all as specified andas directed. 72 Supply onlyEngine oil, multi grade premium Genuine oil 15W40 as per manufacturer recommendations in DG sets complete all as specified.Make : Indian oil/ Hindustan Petrolium/ Castrol/ BPCL. 73 Supply and applying for petrolium Jelly (01 Kg plastic sealed container) complete all as specified and as directed. Make : Indian oil/ Hindustan Petrolium/ Castrol/ BPCL. 74 Supply and fill for genuine coolant in 5 litres plastic sealed containerfor topping up in Radiator of DG set located at different locations complete all as specified and as directed. 75 Material and labour for battery leads of PVC insulated, multistranded, copper conductor of size 50 Sqmm of 1.25 metres long each duly fixed with brass clamps, copper lugs suitable for DG set batteries installed at different locations including removal of existing unserviceable one complete all as specified and as directed. 76 Material and labour for battery teriminal brass clamps including removal of existing unserviceable one compete all as specified and as directed. 77 Maintenance and servicing for Comprehensive "C" Check maintenance service for DG Set of capacity 160 KVAincluding dismantling, cleaning, filter & oil replacement, fuel system overhauling, radiator inspection, valve clearance adjustment, load testing, FIP Caliberation, checking and repair of radiator for leakage,and detailed service report submission as per OEM recommendation to DG setincluding replacement of defective and worn out minor filters gaskets, V- belts, Engine oil, rubber hoses, worm drive clamps, nuts, bolts and cleaning of alternator with vaccum cleaner and attending faults of AMF panels etc, tappet settings if required and greasing of bearings of engine and alternator, checking of batteries, applying petroleum jelly to battery terminals, adding distilled water checking the oil, coolent levels of capacity 100 KVA DG set installed at Southern Command Signal Centrecomplete all as directed by Engr- in- Charge.Note:- (i)Spares required for maintenance will be measured and paid seprately under relevant items. (ii) Servicing to be carried out as per manufacturer’s specifications/ instructions (iii)The work of maintenance shall be carried out through respective authorized dealer whose certificate shall be produced to Engineer - in - charge (iv) Proper record & test results of the same shall be maintained as directed (v)Work shall be carried out at site at different location Work to be carried out by OEM certified technician or approved equivalent. Service reports to be submitted post-maintenance 78 All as per item no. 11.066here-in-above but of capacity 100 KVA. 79 All as per item no. 11.066here-in-above but of capacity 30 KVA. 80 S & FLub oil filter set with O ring, (as perexisting sample) suitable for DG set of capacity 160 KVA. compete all as specified and as directed. 81 S & FLub oil filter set with O ring, (as perexisting sample) suitable for DG set of capacity 100 KVA. compete all as specified and as directed. 82 S & FLub oil filter set with O ring, (as perexisting sample) suitable for DG set of capacity 30 KVA compete all as specified and as directed. 83 S & F diesel filter element set with O ring,suitable forcapacities ofD. G . Set 160 KVA compete all as specified and as directed. 84 S & F diesel filter element set with O ring,suitable forcapacities ofD. G . Set 100 KVA compete all as specified and as directed. 85 S & F diesel filter element set with O ring,suitable forcapacities ofD. G . Set 30 KVA compete all as specified and as directed. 86 S & F air filter element suitable for capacities ofD. G . Set 160 KVAcompete all as specified and as directed. 87 S & F air filter element suitable for capacities ofD. G . Set 100 KVAcompete all as specified and as directed. 88 S & Fair filter element suitable for capacities ofD. G . Set 30 KVAcompete all as specified and as directed. 89 S & F by-pass filter element with "O" ring suitable for 160KVA DG set compete all as specified and as directed. 90 S & F by-pass filter element with "O" ring suitable for 100KVA DG set compete all as specified and as directed. 91 S & F by-pass filter element with "O" ring suitable for 30KVA DG set compete all as specified and as directed. 92 S & Ffan beltcomplete suitable for 100KVA DG set complete all as specified. Make : Fenner/ Dunlop. 93 S & F belt for battery charging alternator complete suitable for 100KVA DG set complete all as specified. Make : Fenner/ Dunlop. 94 S & F rubber hose pipe set for water circuit with clamps complete suitable for 100KVA DG set complete all as specified. 95 M & L for carrying out repairs to AMF panel of 100 KVA DG set at various installation inclduing study, tracing out circuit, testing, replacing all defective parts, rewinding existing power and control wiring with same cables including testing and commissioning complete all as specified and as directed. (Note: Spares like Volt meter, CT, power contactor required for repair will be measuredand paid seperately under relevant items. 96 S & Ffor digital type frequency meter 96 x 96 mm flush/ square pattern compete all as specified. Make: L&T/ AE or equivalent. 97 S & Ffor digital type Ammeter 0-200 /5 Amps 96 x 96 mm square flush pattern with selector switch compete all as specified. Make: L&T/ AE or equivalent 98 S & Ffor digital type Voltmeter 0-500 Volts 96 x 96 mm square flush pattern with selector switch compete all as specified. Make: L&T/ AE or equivalent. 99 S & F for LED indicator lamps R, Y, B with holder 15 mm screw type compete all as specified. Make: Rishab/ L&T/AE/ Legrand or equivalent 100 S & F for battery low maintenance lead acid of capacity 12 volts 135 AH with initial charging including removal of exsting unserviceable one and hand over to store yard compete all as specified and as directed. Make: Exide/ AMCO/ Amaron. 101 S & F for CT cast resin type of ratio 200/5 Amps of suitable VA burden compete all as specified. Make: AE/ L&T/ Nutech/ Amol 102 Supply and fix for lead acid battery 12 Volts 180 AH with initial charging and having indicators to know the status of level of electrolyte complete all as specified and as directedMake- Exide/Amaron. 103 Supply &filling up of transformer oil conforming to IS -335 of 1993 as in topping up / replacementup to desired level of transformer oil capacity and Oil circuit brekar complete all as specified and as directed. [Note: Dielectric strength of oil should not be less than 42 KV/cm complete all as specified and directed.] 104 Supply only breather assembly as per existing size, shape and specification complete for capacity 315 KVA , 11/0.433 Voltstransformers including fresh blue silica gel 105 Painting of transformer after cleaning the body surface of transformer by rubbing with emery Paper to remove oil stains, dust etc and applying one coat of snthetic enamel paintby spray paint incl writing SM No/MES No , capacity of transformer of 315KVA capacity all as directed by Engr-in-Charge 106 Supply and fix for switch air break gang operated HT 11 KV Volt grade out door type, triple poleof capacity 200 amps rating mounted on Polymer based 09 insulator with expulsion fuse set single pole drop out type including Expulsion fuse carriers and fuse element Upto 25 Amp and fitted on steel frame horizontally mechanicallyoperated mechanism from ground level consisting of operating rod of 25 mm bore Heavy grade GI pipe of suitable length worked from ground level and with locking arrangements incl pad locks with key flat iron clamp 50 mm x 6 mm including taking down old unseviceable one complete all as specified and directed. (Universal/Pactil) 107 Supplying, installing, fixing, connecting and testing of polymer based Drop-out fuse set (set of 3 nos), mounted on insulatorswith steel frame 200 Amps capacity, siutable for 11KV, HT system,out door type, including Expulsion fuse carriers and fuse element Upto 25 Amp, including taking down old unserviceable one complete all as specified and directed. Make : Universal/National or its equivalant.Note for Item No 11.094 & 11.095 : The work to be carried out in existing structure. Hence continues shut down will not be available. According to the availabity of shut down timing the contractor shall manage the work in quoated rate only. 108 M&L for Painting of HTpoles including cross arms complete with synthetic enamel paint including filling cavities with filler one coat after cleaning all dust/rust including writing the pole No. and all as directed by Engr-in-Charge 109 M & L for Servicing of Molded Case Circuit Breakers (MCCBs)/ACB in existing panelsincluding cleaning, tightening of connections, checking of mechanical operation, insulation resistance testing, functional testing, lubrication of moving parts, and recording of test results. All tools, materials, labor, and consumables to be included for following capacity:- 110 630 Amps ACB 4 pole,415 volt manual drawout type with micro processor release 111 3 Pole 350A MCCB, 36 kA 112 3 Pole 250A MCCB, 36 kA 113 3 Pole 160A MCCB, 36 kA 114 3 Pole 125A MCCB, 36 kA 115 3 Pole 100A MCCB, 36 kA 116 3 Pole 63A MCCB, 36 kA 117 3 Pole 32A MCCB, 16 kA 118 S & F in repairs ACB 4 Pole, current rating 630 Amp, adjustable over load and short circuit with Micro processor release setting , breaking capacity 36 kA at 415V, 50Hz, of(Make : L & T Cat No CM96111OOOOX1 or equivalent in Legrand / Schenedier) incl necessary spreaders / cable lugs / nut, bolt and washers if required all as directed. 119 S & F for 4 pole MCCB400 A, having breaking capacity 36 kA (Make : L & Tor equivalent in Legrand / Schenedier) complete all as specified and as directed. 120 S & F for4 pole MCCB 250 A, having breaking capacity 36 kA (Make : L & Tor equivalent in Legrand / Schenedier) complete all as specified and as directed. 121 S & F for4 pole MCCB 200 A, having breaking capacity 36 kA (Make : L & Tor equivalent in Legrand / Schenedier) complete all as specified and as directed. 122 S & F for 4 pole MCCB 160 A, having breaking capacity 36 kA (Make : L & Tor equivalent in Legrand/ Schenedier)complete all as specified and as directed. 123 S & F for 4 pole MCCB 100 /125 A, having breaking capacity 36 kA (Make :L & Tor equivalent in Legrand / Schenedier) complete all as specified and as directed. 124 S & F for 4 pole MCCB 63 A, having breaking capacity 10 kA, (Make : L & Tor equivalent in Legrand / Scheneider) complete all as specified and as directed. 125 M&Lfor switch air break gang operated triple pole mechanically operated mounted on HT insulators horizontal type and MS galvanized steel frame with operating mechnizing worked from ground level including operating rod of size 32 mm dia / 25 mm dia as reqd GI medium grade for current rating upto 200 Amps 22000 volts complete with locking arrangement ,ms clamps ,bolts ,nuts and washers etc.including two coat of aluminium paint over a coat of red oxide primer on ms work complete all as specified complete all as specified and as directed. 126 S&F for drop out fuse assy single pole 22KV , 25 Amps rating complete expulsion fuse element mounted on four /two pole structures complete all as specified and as directed.(Necessaty Nut, bolt and washers should be included in above quoted rate) 127 S&F fordrop out fuse assy single pole 11KV , 25 Amps rating complete expulsion fuse element mounted on four / two pole structuresincluding dismanteling old existing UNSV all as specified and as directed.(Necessaty Nut, bolt and washers should be included in above quoted rate) 128 S&F for pin type insulator, HT Polymer/porcelain vitreous white, brown or green of size 150 mm high and 150 mm dia, ISI marked including one galvanised steel spindle, two galvanised iron washers and one galvanised iron nut suitable for 22000 volts including dismantling insulator any type / any sizecomplete all as specified and as directed. 129 S&F for insulator disc type single disc assembly, ISI marked working pressure 22000 volts, porcelain vitreous white, brown, or green size 145 mm high and 255 mm dia ball and socket with tension clamp to suit the size of conductor (ACSR)including dismantling insulator any type / any size complete all as specified and directed. 130 M&L for aluminium strip 25 x 4 mm of required lengthwith color sleeves for jumpering purpose in 11 /22 KV DP/FPincluding taking down existing aluminium conductor etc complete all as per the direction of Engineer-in-charge. 131 S & Ffor gasket set of 22/11 KV 100 KVA to 400 KVA transformer complete all as specified and directed. 132 S& F for silicagel breather complete all as specified and directed. 133 M&L for Testing of exisiting earthing resistance with suitable digital Earth tester complete all as specified and directed 134 S&Fepoxy based insulator with screw, nuts and bolts fixed on OH reservior roof top and on shaft surfaces not more than 2.00 m apart from fixing aluminium or GI strip complete with fixing arragnment complete all as specified and directed. 135 Supply, laying,testing and commissioning or passing through pipe,XLPE insulated, screened, PVC bedded, galvanisedsteel striporwire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area of size 3 core 150 Sqmm 136 Laying in trenches and testing cable XLPE insulated screen PVC bedded galvanized steel strip or wire armoured, electric power cable heavy duty with stranded aluminium conductor, 22000 volts grade of size 3 core X 185 sq mm suitable for earthed system etc complete.(Note-HTcablewill be issued under Sch "B" free for fixing/laying). 137 Supply, installation and testing complete electronic digital type water level indicator devicesuitable for operating at 230V +/- 10%, 50 Hz sysytem having 150mm size digital display and alarm at low/high level of OHT / sump.The complete unit fitted in MS sheet base in two boxes, one box to be installes at sump/OHR and second at pump house bothunit to be connected with flrxible copper cable of .5 sqmm 8 pair and length from sensor to pump house building or OH reservoirs of 21 mtr and 15 mtr staging,All enclosed in sheet metal enclosures of 02mm thick with hinged door and locking arrangement and support GI wire/PVC pipe etc properly laid or fixed on wall / surface all as directed by Eingr-in-charge.Make- SECO type DDS-6 or equivalent model in Schneider/ Havels/ L&T. 138 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 40 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 139 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 50 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 140 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 75 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 141 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 90 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 142 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 110 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 143 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 120 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 144 Supply & Fixing/Laying Double Wall Corrugated (DWC) HDPE Pipes of outer dia 160 mm including 90 degree bends, with coupler and rubber ring,confirming to IS:16205 Part 24 Type 450N, for laying of LT cables protection in trenches etc complete with all accessories all as specified and directed. 145 MISC ITEMS OFEXTERNAL WATER SUPPLY 146 Laying and testing ductile iron pipe with internal cement mortor lining and external zink pipes confirming to IS:8329-2000 with class of pipe K-7 of size 150 mm including rubber tyton joints. Complete all as specified andas directed.Note - DI pipe 150mm bore will be issued under Sch "B" for fixing only. (Rates of DI fitting required for sch B items will be included in the quoted rates) 147 Laying and testingductile iron pipe with internal cement mortor lining and external zink pipes confirming to IS:8329-2000 with class of pipe K-7 of size 200 mm including rubber tyton joints. Complete all as specified andas directed.Note - DI pipe 200mm bore will be issued under Sch "B" for fixing only.(Rates of DI fitting required for sch B items will be included in the quoted rates) 148 Laying and testingductile iron pipe with internal cement mortor lining and external zink pipes confirming to IS:8329-2000 with class of pipe K-7 of size 100 mm including rubber tyton joints. Complete all as specified andas directed.Note - DI pipe 100mm bore will be issued under Sch "B" for fixing only.(Rates of DI fitting required for sch B items will be included in the quoted rates) 149 Supply, fix and testing dual type non return valve of 100 mm bore, cast iron body with both ends flanged,heavy duty (ISI marked) by pass arrangement ,including jointing material, bolts, nuts,rubber packing etc complete confirming to relevent IS. Complete all as specified andas directed. 150 Supply, fix andtesting gun metal dual type non return valve of25mm bore,iron body with both ends flanged,heavy duty (ISI marked) by pass arrangement ,including jointing material, bolts, nuts,rubber packing etc complete confirming to relevent ISComplete all as specified andas directed. 151 M& L for DI fittings & specials such as collar, bends (any type radius, any angle, double end socketted or double flanged or spigot & socket, tail pieces (all socketed or all flanged with an equal & other end taperingbellmouth or flanged plates, connecting pieces straight (both end flanged or socketed of socket & flanged & spigot ends or bellmouth tailpieces ( one end flanged & other end spigot or socket or tatering as bell mouth or flanged ) caps blank flanges heavy duty suitable for run lead joints ofsize from 80 to 200 mm bore. Complete all as specified andas directed. 152 Supply, fix and testing GM gate/globe valves heavy duty conforming to IS 778 with iron wheel head screwed both ends suitable forfollowing sizes ofbore:-Complete all as specified andas directed. 153 25 mm bore 154 40 mm bore 155 50mm bore 156 80 mm bore 157 Install,testingand commissioning of LT distribution outdoor typepanel board compartmentalized fabricated, factory made cubical type dust and vermin proof indoor type power coated 415 volts 3 phase 4 wire 50 HZ front openable with locking arrangement made out of CRCA sheet of 3.15 mm thick with MS angle iron of size 50x50x6 mmto be mounted on floor / wall suitable to accommodate common bus bar and the following accessories:(a) MCCB TPN 100 Amp 25 KA 415 Volt thermal adjustable- 1 No. (b) Copper bus bar 400 Amps. 4 runs duly coloured PVC sleeve (c) Fully automatic star delta starter suitable for 7.5 HP pump set 440 V Model MK-1 Make L and T with electric connection - 02 No. (d) MCCB TP 10 KA 63 Amp - 02 N os (e) MCB DP 32 Amps - 02 Amps(f) Ammete 0-200 amps with CT & selector switch - 01 No (g) Voltmeter 0-500 V with selector switch - 01 No(h) lndiating lamp - LED type RYB ) Complete all as specified andas directed.( Note- LT panel with all fitment accessories shall be issued under Sch "B" free for fixing ) 158 Install test and commissioning of LT distribution panel board compartmentalized fabricated, factory made cubical type dust and vermin proof indoor type power coated 415 volts 3 phase 4 Wire 50 HZ front openable with locking arrangement made out of CRCA sheet of 2 mm thick with MS angle iron of size 50x50x6 mm to be mounted on floor / wall suitable to accommodate common bus bar and the following accessories :- (a) MCCB TPN 63 Amp 25 KV 415 Volt - 1 No.(b) Copper bus bar 400 amp - 4 runs duly coloured PVC sleeve (c) DOL starter suitable for 3.0 HP pump set 440 V Model MK-1 make L&T with electric connection :- 2 No. (d) MCCB TP 40 Amp 10 KA 415 Volt-2 No (e) MCB DP32 Amp - 2 No.(f) Ammeter 0-100 Amp with CT and selector switches – 1 No(g) voltmeter 0-500 V with selector switch 01 No (h) Indicating lamp LED type RYB – 01 Set.Complete all as specified andas directed.( Note- LT panel with all fitment accessories shall be issued under Sch "B" free for fixing ) 159 Install, Test, Commissioning of open well submersible pump set 80x80mm for pumping clear water at ambient temperature from UG sump for delivering 25 m3/hours at a total head of 40 mtr complete with suitable electric motor 7.5 HP, 3 phase, 415 volts, 50 HZ with dry run protector and delivering with GI medium grade pipe of 80 mm dia with flanged bend brought outside the sump GL upto 1.0 mtr and including having GI chain/rubber insulated rope of suitable length to lift the pump set with necessary submersible cable connection.Complete all as specified andas directed. ( Note- submersible pump setshall be issued under Sch "B" free for fixing ) 160 Install, Test, commissioning of open well submersible pump set 25x25 mm for pumping clear water at ambient temperature from UG sump for delivering 165 LPM at a total head of 25 mtr complete with suitable electric motor 3.0 HP, 3 phase, 415 volts, 50 HZ with dry run protector and delivering with GI medium grade pipe of 50 mmdia with flanged bend brought outside the sump GL upto 1.0 mtr and including having GI chain/rubber insulated rope of suitable length to lift the pump set with necessary submersible cable connection .Complete all as specified andas directed.( Note- submersible pump set shall be issued under Sch "B" free for fixing ) 161 Installation, testing and commissioning of 750 LPM capacity head105 M end suction type centrifugal pump set for water supply assembled and tested for rated efficiency complete with energy efficient motor conforming to IS-12615 common base frame, coupling guard and mechanical seal suitable for operation on 415 ± 10% 50 Hz AC supply slow speed up to 1500 Rpm multistage pump with Bronz impeller includsive of suitable star delta starter inclding cable from starter to motor drawn through flexible metallic conduit pipe starter and suitable PCC foundation etc complete as per manufacturers recommendation. Complete all as specified andas directed. ( Note- Centrifugal pump set shall be issued under Sch "B" free for fixing ) 162 Installation, testingend suction type centrifugal pump set for water supply assembled and tested for rated efficiency complete with energy efficient motor conforming to IS-12615 common base frame, coupling guard and mechanical seal suitable for operation on 415 Volt + 10%, 50Hz AC supply slow speed up to 1500 Rpm multistage pump with Bronz impeller inclusive of suitable star delta starter inlcuding cable from starter to motor drawn through flexible metallic conduit pipe following capacity inclusive of starter and PCC suitable foundation as per manufacturers recommendations. Capacity 1460 LPM, Head-100M. Complete all as specified andas directed.( Note- Centrifugal pump set shall be issued under Sch "B" free for fixing ) 163 Supply,install,testing & commissioning of end suction type centrifugal pump set, multistage,bronze impellor,water supply, assembled and tested for rated efficiancy complete with energy efficient motor conforming to IS 12615 common base frame,coupling guard and mechanical seal suitable for operation on 415 volts+/- 10%, 50HZ AC supply of capacity 1500 RPM, 700 LPM, head 70mtr inclusive of PCC foundation ,suction & discharge of pipes as per manufactures instruction.Complete all as specified andas directed.Note:- Cost of suction and discharge pipes upto 7.50 RM long each shall be deemed to be included in the rate quoted. 164 Supply installation,commissioning and testing ofDOSING SYSTEM ( MODEL: ADS-I of ALTOCH) consisting of 40 liter - 100 liter PE/FRP LID & leval gauge along with agitator with shaft and blade in plastic. mounted on tank Complete all as specified andas directed.. (Make : ALTOCH or Equvivalent as approved by Accepting officer) 165 S&F Cast iron body foot valve of size 150 mm bore flanged as per IS 4038 , including nuts, bolts, washers and rubber gaskets, complete all as specified & as directed. 166 Supply installation,commissioning and testing ofdosing pump model 96NGQ51 of Decrain,high presser single head gear motored adjustable dosing pump of following specification:-.(a) Adjustable high presser -0 to 100 PSI (b) Power-230v, 50HZ (c) RPM-44(d) HP 1/10 fractional(e) Out put -2 U.S GPD to 40 USGPDComplete all as specified andas directed.(Make : Decrainor Equvivalent as approved by Accepting officer) 167 S & F Cast iron air release valves with two air outlets of 50mm bore and fixing of cast iron pipe including necessary fittings. Complete all as specified andas directed. 168 Supply,Laying and jointing & testing DI pipe with socket & spigot ends, class K 7 with cement morter lining in side the pipe and zinc coatedout side asper IS 18329/2000 in standard length suitable for push onwith rubber gasket joints(tyton joints) laidintrenchesof size 150 mm bore. Complete all as specified andas directed. 169 Supply, laying, jointing and testing Ductile iron pipes with spigot and socket ends centrifugally cast, Class "K-9" conforming to IS-8329of following sizes, in any length, laid in trenches/ pipe supports etc, pressure testing after laying complete a per IS-12288 including styrene butadiene rubber gasket joints, complete all as specified and as directed.NOTE: Tyton joints required are deemed to be included in the unit rate quoted. 170 100 mm bore pipe 171 200 mm bore pipe 172 M&L testing & Commissioning of LT pannel frame CPRI approved, outdoor type,factory made fabircated to CRCA sheet of with min 1.6mm mm thickness, double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, aluminium bus bar chember (enclosed) with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold,nuts and washer and making complete connection in all respects as diected by engr-in-charge comprising of foillowing parts.INCOMER :-(a)MCCB 200 Amp, FP, Thermal Magnetic release, 35 KA- 01 No as IncomerOUTGOING :-(a)MCCB 160 Amp, TPN,Thermal Magnetic release, 25 KA, 415 Volts - 02 Nos(b)MCB SPN 32 Amps - 01 Nos(c)Indicating lamps (Set of 03 Nos) - 01 Set.(d)Star Delta starter 02 Nos with overload relay ragne 60 Amp- 2 Nos (e) Aluminium bus bar chamber (4 Strips) 3 phase 415 volts 200 Amps fixed on insulatorsall as required - 01 Set 173 (f)Digital voltmeter 0-500 volts with selector switch - 01 Set(g)Digital ammeter with CT"s & selector switch 0-100 A cap- 03 Set(h) Panel Wiring with suitable size PVC insulated PVC sheathed 1100 volts grade with copper conductor multi-stranded cable with lugs on both ends of cable.(i) Front operated on load change over switch 100 amps.-01 No .Make : L&T/C&S/ABB/Havells(j) Star Delta starter fully automatic, 3 phase, 415 volts, 50 Hzheavy duty with overload relay ragne 60 Amp having protection against single phase, over load and phase reversal protection. - 02 NosMake of starter BCH/L&T/ Seimen/C&S/Havellscomplete all as specified and directed. 174 M&L testing & Commissioning of LT pannel frame CPRI approved, outdoor type,factory made fabircated to CRCA sheet of with min 1.6mm mm thickness, double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, aluminium bus bar chember (enclosed) with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold,nuts and washer and making complete connection in all respects as diected by engr-in-charge comprising of foillowing parts.INCOMER :-(a)MCCB 200 Amp, FP, Thermal Magnetic release, 35 KA- 01 No as IncomerOUTGOING :-(a)MCCB 160 Amp, TPN,Thermal Magnetic release, 25 KA, 415 Volts - 02 Nos(b)MCB SPN 32 Amps - 01 Nos(c)Indicating lamps (Set of 03 Nos) - 01 Set.(d)Star Delta starter 02 Nos with overload relay ragne39 Amp- 2 Nos (e) Aluminium bus bar chamber (4 Strips) 3 phase 415 volts 200 Amps fixed on insulatorsall as required - 01 Set(f)Digital voltmeter 0-500 volts with selector switch - 01 Set(g)Digital ammeter with CT"s & selector switch 0-100 A cap- 03 Set 175 (h) Panel Wiring with suitable size PVC insulated PVC sheathed 1100 volts grade with copper conductor multi-stranded cable with lugs on both ends of cable.(i) Front operated on load change over switch 100 amps.-01 No .Make : L&T/C&S/ABB/Havells(j) Star Delta starter fully automatic, 3 phase, 415 volts, 50 Hzheavy duty with overload relay ragne 60 Amp having protection against single phase, over load and phase reversal protection. - 02 NosMake of starter BCH/L&T/ Seimen/C&S/Havellscomplete all as specified and directed. 176 MISC ITEMS B/RWORKS 177 S&F factory made Steel fibre reinforced manhole frame and cover 100mm thick of size 1.20m x 0.60m complete all as specified and directed. 178 M & L for recharging of normal earth pits by excavating the earth at a radius of 600mm from the centre from the earth pit and at a depth of 900mm after removing the earth chambers and accessories carefully and keeping aside for reuse including adding and spreading chemicals as given below in 75mm layers each as ground level and watering, refixing the earth chambers and accessories after allowing the soil to settle down complete all as specified and directed by Engr-in charge.(a) Charcoal 10 kg. (b) Salt 10KgNote :- Excavation , refillingis included in quoated rate 179 Supply and fix for repairs earth chambers by demolishing unserviceable earth chambers and fixing new chambers ofPCC 1:3:6 type C1bed and chamber RCC 1:2:4 type B1of size (600X600X200)mm and thickness 120 mm andand CI cover 10mm thick hinged to CIframe duly groted with PCC, complete all as specified and directed. 180 Construction of valve chamber with PCC solid block masonry grade C-5, 200mm thick having 150mm thick hard core and PCC (1:4:8) type D-2 (using 40mm graded stone aggregate in foundation, including excavation & earth work in any type of soil, internal & external plaster to walls in cement morter 1:6, 15mm thick complete all asspecified and shownon drg No CEPZ/93/TD/20M Sht No 1/1 of following internal dimension:- 181 0.60mtr x 0.60mtr x 0.60mtr 182 1mtr x1mtr x1mtr 183 1.2mtr x1.2mtr x1.2mtr 184 Cutting the existing water line 300 mm dia for inserting Tee Reducer bend, coller etc complete ( Note : CI specials, lead joints excavation and earth work shall be measured and paid separately under relevant item of this schedule ) 185 Moblization of necessary equipment & manpower at site of work to carry out plate load test for determination of "K" Value (Modules of subgrade reaction) of Soil in the field in accordance to IS 9214-1979, complete in all respect, as specified & directed with & including following operations.(a) Digging out Pit of desired size & depth.(b) Placing & arranging Poclain, as per requirement & recording the settlement data with 03 Nos of dial Gauge in Horizontal Plain Placed at 120 degree, using Hydraulic Jack with proving ring & dial gauze of least count 0.002 mm & submission of report in sixtulicate determining modulus of subgrade reaction "K" Value.
|